• Title/Summary/Keyword: Human plasma

Search Result 997, Processing Time 0.032 seconds

Comparison of Coagulase, Deoxyribonuclease (dnase), and Thermostable Nuclease Tests for Identification of Pathogenic Staphylococcus aureus (병원성(病原性) 포도구균(葡萄球菌)의 동정(同定)을 위한 Coagulase, Deoxyribonuclease (DNase) 및 내열성(耐熱性) Nuclease 생산능(生産能)의 비교(比較))

  • Kim, Jong-Myeon;Song, Hee-Jong;Jeong, Ok-Vong
    • Korean Journal of Veterinary Research
    • /
    • v.21 no.2
    • /
    • pp.99-104
    • /
    • 1981
  • A total of 251 clinical isolates (human origin, 43 strains and bovine udder origin 208 strains) of the Staphylococcus that fermented mannitol aerobically were tested for their ability to produce coagulase, DNase, and thermostable nuclease. Of these, 158 isolates coagulated human or bovine plasma, produced DNase, and thermostable, nuclease and were identified as St. aureous, 146 of which produced a 1+ to 3+ clot. The remaining 12 isolated produced a -clot in citrate treated plasma but produced 1+ to 3+ clot in ethylenedi-aminetetraacetic acid (EDTA) treated plasma. It was found that 7 coagulase positive isolates failed to produced thermostable nuclease. In these organisms, we found out of the clot formation is not by coagulase activity but utilization of citrate, because EDTA treated plasma is not coagulated. Among 93 isolates which did not coagulate citrate-or EDTA treated plasma and thermostable nuclease negative, 28 strains produced DNase were identified as St. epidermidis, and other strains were not identification further. It was found that thermostable nuclese production appears to be a consistent property of St. aureus and the test is easy to perform, is rapid became quite distinct within 2 to 4 hour, and is not influenced by as many factors and variations as the coagulase test.

  • PDF

A Study on the Human Growth Hormone Response Following Electro Convulsion Therapy (전기-경련 시술후의 혈장 HGH 반응)

  • Kim, Dong-Ju;Sung, Ho-Kyung;Rhee, Sang-Don
    • The Korean Journal of Physiology
    • /
    • v.10 no.1
    • /
    • pp.67-71
    • /
    • 1976
  • Effect of Electro Convulsion Therapy (ECT) on the Human Growth Hormone (HGH) response was observed in 32 cases of various mental illness. The patients were fasting overnight and ECT was induced in the morning by application of $90{\sim}120V$ for a period of $0.1{\sim}0.5\;sec$. In all patients, venous blood samples were taken prior to simultaneously with 1 and 4 hours after the ECT. Plasma was immediately seperated and stored in $-20^{\circ}C$ refrigerator. HGH concentrantion was determined by means of radioimmunoassay Results were as follows: 1. Application of electric current was not followed by a significant change in mean plasma HGH of 52 cases. 2 Increases of plasma HGH following ECT were observed in about half cases showing low initial level but in 20 other cases with high initial level of plasma HGH, reasonable decreases after therapy were not found. 3. Plasma concentration of HGH one hour after application of current were always higher than just after the current. 4. There were no differences between HGH responses to a 1st, 2nd or 5th ECT. 5. Discussions were made on the possible modification of HGH response following ECT by the autoregulatory control mechanism.

  • PDF

Construction of Membrane Sieves Using Stoichiometric and Stress-Reduced $Si_3N_4/SiO_2/Si_3N_4$ Multilayer Films and Their Applications in Blood Plasma Separation

  • Lee, Dae-Sik;Choi, Yo-Han;Han, Yong-Duk;Yoon, Hyun-C.;Shoji, Shuichi;Jung, Mun-Youn
    • ETRI Journal
    • /
    • v.34 no.2
    • /
    • pp.226-234
    • /
    • 2012
  • The novelty of this study resides in the fabrication of stoichiometric and stress-reduced $Si_3N_4/SiO_2/Si_3N_4$ triple-layer membrane sieves. The membrane sieves were designed to be very flat and thin, mechanically stress-reduced, and stable in their electrical and chemical properties. All insulating materials are deposited stoichiometrically by a low-pressure chemical vapor deposition system. The membranes with a thickness of 0.4 ${\mu}m$ have pores with a diameter of about 1 ${\mu}m$. The device is fabricated on a 6" silicon wafer with the semiconductor processes. We utilized the membrane sieves for plasma separations from human whole blood. To enhance the separation ability of blood plasma, an agarose gel matrix was attached to the membrane sieves. We could separate about 1 ${\mu}L$ of blood plasma from 5 ${\mu}L$ of human whole blood. Our device can be used in the cell-based biosensors or analysis systems in analytical chemistry.

THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE (기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰)

  • Whang, Yun-Hi;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.741-755
    • /
    • 1995
  • Currently titanium is the material of choice for implants because of its biological acceptance. This high degree of biocompatibility is thought to result, in part, from the protective and stable oxide layer that presumably aids in the bonding of the extracellular matrix at the implant-tissue interface. Endosseous dental implants are interfaced with bone, connective tissue, and epithelium when implanted into the jaw bone. The soft tissue interface including connective tissue and epithelium is one of the most critical factors in the determination of implant maintenance and prognosis. For maintenance of failing or failed implants, it is essential to treat the implant fixture surface to remove bacterial endotoxins and make a surface tolerated by surrounding soft and hard tissues. In this study, the effect of mechanical treatment on titanium plasma sprayed implant on adhesiveness and proliferation of human gingival fibroblasts and changed surface characteristics were studied. titanium plasma sprayed discs manufactured by Friedrichsfeld company were treated with loaw speed stone bur, a rubber point and a jetpolisher. Its surface components were analyzed with Energy dispersive X-ray spectroscopy to evaluate whether the surface characteristics were altered or not. To observe the spreading pattern of the human gingival fibroblasts which attached to the all specimens author used the scanning electron microscope. The results were as follows : Pure titanium and plasma sprayed titanium, stone polished titanium showed titanium peak and small amout of aluminum, so there was no alteration on surface characteristics. Under the scanning electron microscopic examination in the initial attachment of human gingival fibroblast, there was a slight enhancement in pure titanium, stone polished titanium than plasma sprayed titanium. After 6 hours, the pure titanium and stone polished titanium showed human gingival fibroblasts were elongated and connected with numerous processes. Human gingival fibroblasts were more intimately attached on the pure titanium discs than on the other discs. The human gingival fibroblasts attached on the plasma sprayed titanium by thin and elongated processes. After 24 hours, the human gingival fibroblasts connected with each other via numerous processes and compeletly covered the pure titanium and stone polshed titanium discs. Human gingival fibroblasts had multiple point contacts with more long and thin lamellopodia and showed a little bare surface on plasma sprayed titanium discs.

  • PDF

Association between Genetic Variation in the Human Factor Ⅶ Gene and Essential Hypertension in Korean Population

  • Shin, Jung-Hee;Kang, Byung-Yong;Lee, Kyung-Ho;Lee, Chung-Choo;Kim, Ki-Tae
    • Environmental Mutagens and Carcinogens
    • /
    • v.21 no.2
    • /
    • pp.106-112
    • /
    • 2001
  • In view of the effect of factor Ⅶ as a risk factor for essential hypertension, we investigated the length (I/D) polymorphism at position 323 promoter region and exon 8-Msp I RFLP of the human factor Ⅶ gene in the Korean patients with essential hypertension and normal controls. There were no significant differences in the allele, genotype and haplotype frequencies of these polymorphisms between normotensive and essential hypertensive subjects. The significant linkage disequilibrium was however, detected between two polymorphic sites. The Msp I RFLP and I/D polymorphism were also significantly associated with plasma triglyceride (TG) levels. Therefore, our results suggest that the significant association between two genetic variations in the human factor Ⅶ gene and plasma TG level may reflect the potential role of human factor Ⅶ gene as one of the genetic components for cardiovascular risk.

  • PDF

Development of Proteomics and Applications of Proteomics in Toxicology

  • Jung, Woon-Won;Huh, Yoon-Ee;Ryu, Jae-Chun;Lee, Eun-Il;Sul, Dong-Geun
    • Molecular & Cellular Toxicology
    • /
    • v.1 no.1
    • /
    • pp.7-12
    • /
    • 2005
  • Proteomics has recently received intense scientific interest after the completion of the Human Genome Project, because this genome-based high technology allows to search new drug targets or diagnostic markers. Many proteome projects including Human plasma proteome projects (HPPP), Human liver proteome projects (HLPP), Human brain proteome projects (HBPP), and Mouse and Rat Proteome Project (MRPP) have been carried out and proteomic analytical techniques have been developed in second dimensional electrophoresis (2-DE) and LC/MS system. This powerful method has been applied in toxicology producing a new term "Toxicoproteomics". In this review, recent proteome projects, proteomic technologies, and toxicoproteomics will be discussed.

HPLC Determination of Loratadine in Human Plasma with UV Detection and Pharmacokinetics of Loratadine Following Oral Administration of Tablet Formulation in Human

  • Cho, Eun-Sook;Chun, In-Koo
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.420.2-421
    • /
    • 2002
  • A validated UV determination of loratadine in human plasma was developed and the pharmacokinetic profiles of single dose of loratadine were determined in 8 healthy volunteers. Human serum samples (1.0 mL) spiked with known concentration of loratadine and 50 ng diazepam as an internal standard were alkalinized with 500 ${\mu}\ell$ ${\mu}\ell$ of 10% $Na_{2}CO_{3}$ and extracted with 7 mL of mixture of isopentane and hexane (2 : 1. v/v) for 5 min. Extracts were centrifuged and 6 mL of organic layer was back-extracted with 150 ${\mu}\ell$ of 12.5% $Na_{2}PO_{4}$ for 1 min. (omitted)

  • PDF

Effects of a Pre-Exercise Meal on Plasma Growth Hormone Response and Fat Oxidation during Walking

  • Shin, Young-Ho;Jung, Hyun-Lyung;Ryu, Jong-Woo;Kim, Pan-Soo;Ha, Tae-Yeol;An, Ji-Yoon;Kang, Ho-Youl
    • Preventive Nutrition and Food Science
    • /
    • v.18 no.3
    • /
    • pp.175-180
    • /
    • 2013
  • The purpose of this study was to determine the effects of a pre-exercise meal on the plasma human growth hormone (hGH) response and fat oxidation during walking. Subjects (n=8) were randomly provided with either 1 g/kg body weight of glucose in 200 mL water (CHO) or 200 mL water alone (CON) 30 min prior to exercise and subsequently walked on a treadmill at 50% of VO2max for 60 min. Plasma hGH concentrations were significantly higher in subjects who received CHO compared to those who received CON at 15 and 30 min. The fat oxidation rate in the CHO was significantly lower than the CON while walking for 5~15, 25~35 and 45~55 min. Plasma FFA levels were also significantly lower in the CHO compared to the CON at 30, 45 and 60 min. Plasma glucose levels in the CHO were significantly lower while plasma insulin levels were significantly higher than in the CON at 15 and 30 min. Therefore, the results of this study suggest that the elevation of plasma hGH levels due to the intake of a pre-exercise meal may not be strongly related to fat oxidation and plasma free fatty acid (FFA) levels during low-intensity exercise.

Validation of LC-MS/MS method for determination of ginsenoside Rg1 in human plasma (인체 혈장 중 Ginsenoside Rg1의 정량을 위한 LC-MS/MS 분석법 검증)

  • Kim, Yunjeong;Han, Song-Hee;Jeon, Ji-Young;Hwang, Min-Ho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.221-227
    • /
    • 2013
  • A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the investigation of the ginsenoside Rg1 in human plasma. After addition of internal standard (digoxin), plasma was diluted with acetone and methanol (80:20), the supernatant was concentrated and analyzed by LC-MS/MS. The optimal chromatographic separation was achieved on an Agilent Eclipse XDB-C18 column ($4.6{\times}150mm$, $5{\mu}m$) with a mobile phase of 0.1% formic acid in water and 0.1% formic acid in methanol at a flow rate of 0.9 mL/min gradient mode. The standard calibration curve for ginsenoside Rg1 was linear ($r^2=0.9995$) over the concentration range 1~500 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of ginsenoside Rg1 was lower than 7.53% (correlation of variance, CV), and accuracy exceeded 98.28%. This LC-MS/MS assay of ginsenoside Rg1 in human plasma is applicable for quantifying in the pharmacokinetic study.

Determination of lercanidipine in human plasma by LC-MS/MS (LC-MS/MS를 이용한 혈장 중 레르카니디핀의 분석)

  • Jang, Moon-Sun;La, Sookie;Chang, Kyu Young;Kang, Seung Woo;Han, Sang Beom;Lee, Kyung Ryul;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of lercanidipine in human plasma. After addition of internal standard (amlodipine), plasma was precipitated with acetonitrile and the supernatant was evaporated. The residues were dissolved in 50 % acetonitrile and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring(MRM) mode, lercanindipine were selectively detected without severe interference from human plasma. The standard calibration curve for lercanidipine was linear (r = 0.9994) over the concentration range 0.05-20.0 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of lercanidipine was lower than 11.7 % (correlation of variance, CV), and accuracy was between 94.4-114.8 %. This method has been successfully applied to the pharmacokinetic study of lercanidipine in human plasma.