• Title/Summary/Keyword: Human body size

Search Result 495, Processing Time 0.038 seconds

Lifetime test of batteries for BLE modules for site identification of vessel's crews and passengers (SIVCP) (SIVCP용 BLE 모듈의 배터리 수명시험)

  • Kwon, Hyuk-joo;Kim, Min-Gwon;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.754-759
    • /
    • 2015
  • Nowadays, short distance communication systems with low power energy (LPE) are developed for identification and monitoring of site identification of vessel crews and passengers (SIVCP). LPE communication modules, such as Bluetooth low energy (BLE) and Zigbee, are used for short distance communications with LPE. These modules enable 1:N communications and their popularity is growing since the modules can be mounted on movable objects, such as mobile devices and human body. When these modules are used, the important factor that affects their operation time and design are the capacity and size of battery. Therefore, they must be made as small as possible, and the battery should be selected to be slightly smaller than the module. In this study, we calculate the theoretical life of batteries used in SIVCP BLE modules using data sheet and discharge characteristic graph under the condition of a 1/250 transmission-ratio (TR). We thus calculate experimental life by measuring transmission current for the same TR, and low speed mode current for a 1/5000 TR and measure long-term experimental life using 1/25 TR for days. Through these experiments, we verify experimental methods for the prediction and extension of battery life that would enable us to select appropriate sizes of batteries based on vessel usage and passenger types. The selections of the module TR and battery size are important factors affecting the cost reduction of module design, the battery maintenance, and passenger convenience.

Comparison of Temperature Distribution in Agar Phantom and Gel Bolus Phantom by Radiofrequency Hyperthermia

  • Jung, Dong Kyung;Kim, Sung Kyu;Lee, Joon Ha;Youn, Sang Mo;Kim, Hyung Dong;Oh, Se An;Park, Jae Won;Yea, Ji Won
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.224-231
    • /
    • 2016
  • The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with that of the Gel Bolus phantom under conditions similar to those of an agar phantom that can continuously carry out temperature measurement. The temperatures of the agar phantom and the Gel Bolus phantom were raised to $36.5{\pm}3^{\circ}C$ and a temperature sensing was inserted at depths of 5, 10, and 15 cm from the phantom central axis. The temperature increase rate and the coefficient of determination were analyzed while applying output powers of 100 W and 150 W, respectively, at intervals of 1 min for 60 min under conditions where the indoor temperature was in the range $24.5{\sim}27.5^{\circ}C$, humidity was 35~40%, internal cooling temperature of the electrode was $20^{\circ}C$, size of the upper electrode was 250 mm, and the size of the lower electrode was 250 mm. The coefficients of determination of 150 W output power at the depth point of 5 cm from the central axis of the phantom were analyzed to be 0.9946 and 0.9926 in the agar and Gel Bolus phantoms, respectively; moreover, the temperature change equation of the agar and Gel Bolus phantoms with time can be expressed as follows in the state the phantom temperature is raised to $36^{\circ}C:Y(G)$ is equation of Gel Bolus phantoms (in 5 cm depth) applying output power of 150 W. Y(G)=0.157X+36. It can be seen that if the temperature is measured in this case, the Gel Bolus phantom value can be converted to the measured value of the agar phantom. As a result of comparing the temperature distribution characteristics of the agar phantom of a human-body-equivalent material with those of the Gel Bolus phantom that can be continuously used, the usefulness of Gel Bolus phantom was exhibited.

Auto-Segmentation Algorithm For Liver-Vessel From Abdominal MDCT Image (복부 MDCT 영상으로부터 간혈관 자동 추출 알고리즘)

  • Park, Seong-Me;Lee, You-Jin;Park, Jong-Won
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.430-437
    • /
    • 2010
  • It is essential for living donor liver transplantation that surgeon must understand the hepatic vessel structure to improve the success rate of operation. In this paper, we extract the liver boundary without other surrounding structures such as heart, stomach, and spleen using the contrast enhanced MDCT liver image sequence. After that, we extract the major hepatic veins (left, middle, right hepatic vein) with morphological filter after review the basic structure of hepatic vessel which reside in segmented liver image region. The purpose of this study is provide the overall status of transplantation operation with size estimation of resection part which is dissected along with the middle hepatic vein. The method of liver extraction is as follows: firstly, we get rid of background and muscle layer with gray level distribution ratio from sampling process. secondly, the coincident images match with unit mesh image are unified with resulted image using the corse coordinate of liver and body. thirdly, we extract the final liver image after expanding and region filling. Using the segmented liver images, we extract the hepatic vessels with morphological filter and reversed the major hepatic vessels only with a results of ascending order of vessel size. The 3D reconstructed views of hepatic vessel are generated after applying the interpolation to provide the smooth view. These 3D view are used to estimate the dissection line after identify the middle hepatic vein. Finally, the volume of resection region is calculated and we can identify the possibility of successful transplantation operation.

Development and Evaluation of Natural Hydroxyapatite Ceramics Produced by the Heat Treatment of Pig Bones

  • Lim, Ki-Taek;Kim, Jin-Woo;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.227-234
    • /
    • 2014
  • Purpose: The aim of this research was to develop and evaluate natural hydroxyapatite (HA) ceramics produced from the heat treatment of pig bones. Methods: The properties of natural HA ceramics produced from pig bones were assessed in two parts. Firstly, the raw materials were characterized. A temperature of $1,200^{\circ}C$ was chosen as the calcination temperature. Fine bone powders (BPs) were produced via calcinations and a milling process. Sintered BPs were then characterized using field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), energy dispersive X-ray spectroscopy (EDX), Fourier transform infrared (FTIR) spectroscopy, and a 2-year in vitro degradability test. Secondly, an indirect cytotoxicity test was conducted on human osteoblast-like cells, MG63, treated with the BPs. Results: The average particle size of the BPs was $20{\pm}5{\mu}m$. FE-SEM showed a non-uniform distribution of the particle size. The phase obtained from XRD analysis confirmed the structure of HA. Elemental analysis using XRF detected phosphorus (P) and calcium (Ca) with the Ca/P ratio of 1.6. Functional groups examined by FTIR detected phosphate ($PO{_4}^{3-}$), hydroxyl ($OH^-$), and carbonate ($CO{_3}^{2-}$). The EDX, XRF, and FTIR analysis of BPs indicated the absence of organic compounds, which were completely removed after annealing at $1,200^{\circ}C$. The BPs were mostly stable in a simulated body fluid (SBF) solution for 2 years. An indirect cytotoxicity test on natural HA ceramics showed no threat to the cells. Conclusions: In conclusion, the sintering temperature of $1,200^{\circ}C$ affected the microstructure, phase, and biological characteristics of natural HA ceramics consisting of calcium phosphate. The Ca-P-based natural ceramics are bioactive materials with good biocompatibility; our results indicate that the prepared HA ceramics have great potential for agricultural and biological applications.

A Study on a Quantified Structure Simulation Technique for Product Design Based on Augmented Reality (제품 디자인을 위한 증강현실 기반 정량구조 시뮬레이션 기법에 대한 연구)

  • Lee, Woo-Hun
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.85-94
    • /
    • 2005
  • Most of product designers use 3D CAD system as a inevitable design tool nowadays and many new products are developed through a concurrent engineering process. However, it is very difficult for novice designers to get the sense of reality from modeling objects shown in the computer screens. Such a intangibility problem comes from the lack of haptic interactions and contextual information about the real space because designers tend to do 3D modeling works only in a virtual space of 3D CAD system. To address this problem, this research investigate the possibility of a interactive quantified structure simulation for product design using AR(augmented reality) which can register a 3D CAD modeling object on the real space. We built a quantified structure simulation system based on AR and conducted a series of experiments to measure how accurately human perceive and adjust the size of virtual objects under varied experimental conditions in the AR environment. The experiment participants adjusted a virtual cube to a reference real cube within 1.3% relative error(5.3% relative StDev). The results gave the strong evidence that the participants can perceive the size of a virtual object very accurately. Furthermore, we found that it is easier to perceive the size of a virtual object in the condition of presenting plenty of real reference objects than few reference objects, and using LCD panel than HMD. We tried to apply the simulation system to identify preference characteristics for the appearance design of a home-service robot as a case study which explores the potential application of the system. There were significant variances in participants' preferred characteristics about robot appearance and that was supposed to come from the lack of typicality of robot image. Then, several characteristic groups were segmented by duster analysis. On the other hand, it was interesting finding that participants have significantly different preference characteristics between robot with arm and armless robot and there was a very strong correlation between the height of robot and arm length as a human body.

  • PDF

Embryonic and Larval Development of Slender Catfish, Silurus microdorsalis Mori, 1936, Endemic to Korea (한국 고유종 미유기(Silurus microdorsalis Mori, 1936)의 난 발생 및 자치어 형태발달)

  • Kang-Rae Kim;Yeong-Ho Kwak;Mu-Sung Sung;Heon Yang;Seong-Jang Cho;Bong Han Yun;In-Chul Bang
    • Korean Journal of Ichthyology
    • /
    • v.35 no.2
    • /
    • pp.91-100
    • /
    • 2023
  • The early life history of Silurus microdorsalis living in Jahocheon Stream was studied by observing egg and morphological development. Live fish were captured in June 2018, then reared in a circulating filtration system under a 14L : 10D photoperiod with a water temperature of 18℃. To artificially induce spawning, females were injected with 0.5 mL of Ovaprim (Syndel, Nanaimo, BC, Canada) per kg of body weight, and males were injected with 10,000 IU/kg body weight of human chorionic gonadotropin. Approximately 15 h later, eggs were artificially inseminated by the dry method. Mature eggs were light pale yellow, which separated them from immature eggs. Fertilized eggs were 2.16±0.06 mm (n=8) in diameter and fully hatched at 181 h after fertilization. The fertilization rate was 63.1±2.2%, and 10.0±3.7% of the embryos were malformed at 18℃. The rates of development were 181 h at 18℃, 109 h at 21℃, and 76 h at 24℃. The larval size immediately after hatching was 4.64±0.22 mm (n=8), and the larvae displayed negative phototaxis at 1 day after hatching. The total larval length on 7 days after hatching was 12.47±0.53 mm, with 25~30 basal anal fin rays and 14~16 basal caudal fin rays observed. The total larval length was 14.13±0.51 mm on 9 days after hatching, and approximately 90% of the black endoplasmic reticulum was deposited on the head and body. The dorsal fin had formed, and a single basal body was observed. On 15 days after hatching, the total larval length was 16.69±0.31 mm; the number of basal caudal fin rays (18 poles) was an integer because 2 dorsal fin basal rays and 60~63 anal fin basal rays were observed. The total larval length was 28.96±1.10 mm on 50 days after hatching; the numbers of caudal fins (n=18), dorsal fins (n=3), pectoral fins (n=11), and anal fin basal rays (n=67~73) were integers.

The Effect of LhGH on Hair Regeneration in C57BL/6CrN Mouse (LhGH가 마우스(C57BL/6CrN)의 모발 재성장에 미치는 영향)

  • Kim, Yong-Ju;Kim, Tae-Keun;Min, Byoung-Hoon;Kim, Soo-Jin
    • Applied Microscopy
    • /
    • v.41 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • Hair is an appendage of skin which protects the body from outer physical and chemical stimuli. Hair is generated from the hair follicle lying on a sunken basal layer of epidermis. Hair cycling, which regenerates hair follicles throughout the life time of the organism. Numerous kinds of factors which exist at the hair follicle have been reported to regulate hair cycling, Human growth hormone secreted from pituitary gland, initially demonstrated to accelerate organ's growth, has been reported to play a role in the biology of organ size determination. We investigated the effect of 6-histidines residues tagged at amino-terminus of human growth hormone using light and electronmicroscopic methods. Human growth hormone encapsulated in nano-liposome (LhGH) was used to find how LhGH affects hair follicle cycling of mouse (C57BL6/CrN). Distilled water as a negative control, 3% Minoxidil as a positive control, and LhGH were applied to mouse for weeks. LhGH increased the number of exposed hairs per given areas ($1mm^2$). This result was also confirmed using a different breed of mice which show natural hair loss in an old age (about 17 months after birth). When LhGH was applied for 3 weeks after natural hair loss, natural hair loss on these mice was prevented, However, the control group mice on which LhGH was not applied showed further hair loss. This result indicates that LhGH may stimulate hair cycling of mouse. In clusion, it is cleat that the LhGH increased the number of hair on mice and help the depilated skin to grow new hair follicles again.

In Vitro Stability of Liposomes Containing Newly Synthesized Glycolipid (신규 합성 당지질 함유 리포솜의 In Vitro 안정성)

  • Song, Chung-Kil;Jung, Soon-Hwa;Seong, Ha-Soo;Cho, Sun-Hang;Shin, Byung-Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • Liposomes having particle size from several tens to hundreds nanometers are efficient carriers for injectable drug delivery. Enhancement of liposome stability in bloodstream has been studied because of its relatively short circulation time and fast clearance from human body by reticuloendothelial system (RES) in blood vessel. In this study, new disaccharide-1,2-distearoyl-sn-glycero-3-phosphoethanolamine (DSPE) derivatives in which lactose or sucrose as the disaccharide molecule was conjugated covalently to DSPE were synthesized. Liposomes of which surface had disaccharide molecules were prepared by incorporating the disaccharide-DSPE into liposomes as one of their lipid components. Particle size of the prepared liposomes was approximately 100 nm. The liposomes of which surface were modified with the disaccharide-DSPE showed -25 mV of zeta potential value due to the presence of hydroxyl groups on their surface, while the unmodified control liposomes showed -10 mV of zeta potential value. Loading efficiency of model drug, doxorubicin, into liposomes was about 90%. Stability of the disaccharide-modified liposomes in vitro was evaluated by monitoring the amount of protein adsorption and particle size of the liposomes in serum. Disaccharide-modified liposomes were more stable in serum than unmodified control liposomes or polyethyleneglycol (PEG)-modified liposomes due to less adsorption of serum protein and hence less increase of their particle size. The liposomes of which surface was modified with disaccharide-DSPE conjugate can be used as long-circulating carriers for drugs having high toxicity or short half-life time due to their enhanced stability in blood circulatory system.

The effect of silk fibroin and rhBMP-2 on bone regeneration in rat calvarial defect model (백서 두개골결손모델에서 실크단백과 골형성단백 이식체가 골재생에 미치는 영향)

  • Nam, Jeong-Hun;Noh, Kyung-Lok;Pang, Eun-O;Yu, Woo-Geun;Kang, Eung-Sun;Kweon, Hae-Yong;Kim, Seong-Gon;Park, Young-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.366-374
    • /
    • 2010
  • Introduction: This study evaluated the capability of silk fibroin (SF) and recombinant human bone morphogenetic protein-2 loaded SF (SF-BMP) as a bone defect replacement matrix when grafted in a calvarial bone defect of rats in vivo. Materials and Methods: A total 70 calvarial critical size defects (5.0 mm in diameter) made on 35 adult female Sprague-Dawley rats were used in this study. The defects were transplanted with (1) rhBMP-2 loaded silk fibroin graft (SF-BMP: 0.8+$10\;{\mu}g$), (2) Silk fibroin (SF: $10\;{\mu}g$), and (3) no graft material (Raw). The samples were evaluated with soft x-rays, alkaline phosphatase activity, calcium/phosphate quantification, histological and histomorphometric analysis at postoperative 4 and 8 weeks. Results: The SF-BMP group ($48.86{\pm}14.92%$) had a significantly higher mean percentage bone area than the SF group ($24.96{\pm}11.01%$) at postoperative 4 weeks.(P<0.05) In addition, the SF-BMP group ($40.01{\pm}12.43%$) had a higher % bone area at postoperative 8 weeks than the SF group ($33.26{\pm}5.15%$). The mean ratio of gray scale levels to the host bone showed that the SF-BMP group ($0.67{\pm}0.08$) had a higher mean ratio level than the SF group ($0.61{\pm}0.09$) at postoperative 8 weeks. These differences were not statistically significant.(P=0.168 and P=0.243, respectively) The ratio of the calcium and phosphate contents of the SF-BMP ($0.93{\pm}0.22$) group was lower than that of the SF ($1.90{\pm}1.42$) group at postoperative 4 weeks. However, the SF-BMP group ($0.75{\pm}0.31$) had a higher Ca/$PO_4$ ratio than the SF ($0.68{\pm}0.04$) at postoperative 8 weeks. These differences were not statistically significant.(P=0.126 and P=0.627, respectively) For the bone-specific alkaline phosphatase (ALP) activity, which is recognized as a reliable indicator of the osteoblast function, the SF-BMP ($23.71{\pm}8.60\;U/L$) groups had a significantly higher value than the SF group ($12.65{\pm}6.47\;U/L$) at postoperative 4 weeks.(P<0.05) At postoperative 8 weeks, the SF-BMP ($21.65{\pm}10.02\;U/L$) group had a lower bone-specific ALP activity than the SF group ($16.72{\pm}7.35\;U/L$). This difference was not statistically significant.(P=0.263) For the histological evaluation, the SF-BMP group revealed less inflammation, lower foreign body reactions and higher bone healing than the SF group at postoperative 4 and 8 weeks. The SF group revealed more foreign body reactions at postoperative 4 weeks. However, this immunogenic reaction decreased and the remnant of grafted material was observed at postoperative 8 weeks. For histomorphometric analysis, the SF-BMP group had a significantly longer bone length to total length ratio than those of the SF group at postoperative 4 and 8 weeks.(P<0.05) Conclusion: The rhBMP-2 loaded silk fibroin graft revealed fewer immunoreactions and inflammation as well as more new bone formation than the pure silk fibroin graft. Therefore, silk fibroin may be a candidate scaffold for tissue engineered bone regeneration.

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.