A Non-invasive Real-time Respiratory Organ Motion Tracking System for Image Guided Radio-Therapy (IGRT를 위한 비침습적인 호흡에 의한 장기 움직임 실시간 추적시스템)

  • Kim, Yoon-Jong;Yoon, Uei-Joong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.676-683
    • /
    • 2007
  • A non-invasive respiratory gated radiotherapy system like those based on external anatomic motion gives better comfortableness to patients than invasive system on treatment. However, higher correlation between the external and internal anatomic motion is required to increase the effectiveness of non-invasive respiratory gated radiotherapy. Both of invasive and non-invasive methods need to track the internal anatomy with the higher precision and rapid response. Especially, the non-invasive method has more difficulty to track the target position successively because of using only image processing. So we developed the system to track the motion for a non-invasive respiratory gated system to accurately find the dynamic position of internal structures such as the diaphragm and tumor. The respiratory organ motion tracking apparatus consists of an image capture board, a fluoroscopy system and a processing computer. After the image board grabs the motion of internal anatomy through the fluoroscopy system, the computer acquires the organ motion tracking data by image processing without any additional physical markers. The patients breathe freely without any forced breath control and coaching, when this experiment was performed. The developed pattern-recognition software could extract the target motion signal in real-time from the acquired fluoroscopic images. The range of mean deviations between the real and acquired target positions was measured for some sample structures in an anatomical model phantom. The mean and max deviation between the real and acquired positions were less than 1mm and 2mm respectively with the standardized movement using a moving stage and an anatomical model phantom. Under the real human body, the mean and maximum distance of the peak to trough was measured 23.5mm and 55.1mm respectively for 13 patients' diaphragm motion. The acquired respiration profile showed that human expiration period was longer than the inspiration period. The above results could be applied to respiratory-gated radiotherapy.

Evaluation of the Dose According to the Movement of Breath During Field-in-Field Technique Treatment of Breast Cancer Patients (유방암 환자의 Field-in-Field Technique 치료 시 호흡의 움직임에 따른 선량 평가)

  • Kwon, Kyung-Tae
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.561-566
    • /
    • 2018
  • Field-in-Field Technique is applied to the radiation therapy of breast cancer patients, and it is possible to compensate the difference in breast thickness and deliver uniform dose in the breast. However, there are several fields in the treatment field that result in a more complex dose delivery than a single field dose delivery. If the patient's respiration is irregular during the delivery of the dose by several fields and the change of respiration occurs, the dose distribution in the breast changes. Therefore, based on the computed tomography images of breast cancer patients, a human model was created by using a 3D printer (Builder Extreme 1000) to describe the volume in the same manner. A computerized tomography (CT) of the human body model was performed and a treatment plan of 260 cGy / fx was established using a 6-MV field-in-field technique using a computerized treatment planning system (Eclipse 13.6, Varian, USA). The distribution of the dose in the breast according to the change of the respiration was measured using a moving phantom at 0.1 cm, 0.3 cm, 0.5 cm amplitude, using a MOSOXIDE Silicon Field Effect Transistor (MOSFET, Best Medical, Canada) Were measured and compared. The distribution of dose in the breast according to the change of respiration showed similar value within ${\pm}2%$ in the movement up to 0.3 cm compared to the treatment plan. In this experiment, we found that the dose distribution in the breast due to the change of respiration when the change of respiration was increased was not much different from the treatment plan.

Comparative Studies on Absorbed Dose by Geant4-based Simulation Using DICOM File and Gafchromic EBT2 Film (DICOM 파일을 사용한 Geant4 시뮬레이션과 Gafchromic EBT2 필름에 의한 인체 내 흡수선량 비교 연구)

  • Mo, Eun-Hui;Lee, Sang-Ho;Ahn, Sung-Hwan;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.48-53
    • /
    • 2013
  • Monte Carlo method has been known as the most accurate method for calculating absorbed dose in the human body, and an anthropomorphic phantom has been mainly used as a method of simulating internal organs for using such a calculation method. However, various efforts are made to extract data on several internal organs in the human body directly from CT DICOM files in recent Monte Carlo calculation using Geant4 code and to use by converting them into the geometry necessary for simulation. Such a function makes it possible to calculate the internal absorbed dose accurately while duplicating the actual human anatomical structure. Thus, this study calculated the absorbed dose in the human body by using Geant4 associating with DICOM files, and aimed to confirm the usefulness by compare the result with the measured dose using a Gafchromic EBT2 film. This study compared the dose calculated using simulation and the measured dose in beam central axis using the EBT2 film. The results showed that the range of difference was an average of 3.75% except for a build-up region, in which the dose rapidly changed from skin surface to the depth of maximum dose. In addition, this study made it easy to confirm the target absorbed dose by internal organ and organ through the output of the calculated value of dose by CT slice and the dose value of each voxel in each slice. Thus, the method that outputs dose value by slice and voxel through the use of CT DICOM, which is actual image data of human body, instead of the anthropomorphic phantom enables accurate dose calculations of various regions. Therefore, it is considered that it will be useful for dose calculation of radiotherapy planning system in the future. Moreover, it is applicable for currently-used several energy ranges in current use, so it is considered that it will be effectively used in order to check the radiation absorbed dose in the human body.

Evaluation of Lung Dose Using Linac Photon Beam in Geant 4 Simulation (Geant4 Simulation에서 Linac 광자선을 이용한 폐 선량평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.443-450
    • /
    • 2018
  • The Geant 4 simulated the linear accelerator (VARIAN CLINAC) based on the previously implemented BEAMnrC data, using the head structure of the linear accelerator. In the 10 MV photon flux, Geant4 was compared with the measured value of the percentage of the deep dose and the lateral dose of the water phantom. In order to apply the dose calculation to the body part, the actual patient's lung area was scanned at 5 mm intervals. Geant4 dose distributions were obtained by irradiating 10 MV photons at the irradiation field ($5{\times}5cm^2$) and SAD 100 cm of the water phantom. This result is difficult to measure the dose absorbed in the actual lung of the patient so the doses by the treatment planning system were compared. The deep dose curve measured by water phantom and the deep dose curve calculated by Geant4 were well within ${\pm}3%$ of most depths except the build-up area. However, at the 5 cm and 20 cm sites, 2.95% and 2.87% were somewhat higher in the calculation of the dose using Geant4. These two points were confirmed by the geometry file of Genat4, and it was found that the dose was increased because thoracic spine and sternum were located. In cone beam CT, the dose distribution error of the lungs was similar within 3%. Therefore, if the contour map of the dose can be directly expressed in the DICOM file when calculating the dose using Geant4, the clinical application of Geant4 will be used variously.

Analysis of Scattering Rays and Shielding Efficiency through Lead Shielding for 0.511 MeV Gamma Rays Based on Skin Dose (피부선량을 기준으로 0.511 MeV 감마선에 대한 납 차폐체의 산란선 및 차폐 효율 분석)

  • Jang, Dong-Gun;Park, Eun-Tae
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.259-264
    • /
    • 2020
  • Radiation causes radiation hazards in the human body. In Korea, a case of radiation necrosis occurred in 2014. In this study, the scatter and shielding efficiency according to lead shielding were classified into epidermis and dermis for 0.511 MeV used in nuclear medicine. In this study, experiments were conducted using the slab phantom that represents calibration and the dose of human trunk. Experimental results showed that the shielding rate of 0.25 mmPb was 180% in the epidermis and 96% in the dermis. Shielding at 0.5mmPb showed shielding rates of 158%in the epidermis and 82% in the dermis. As a result of measuring the absorbed dose by subdividing the thickness of the dermis into 0.5 mm intervals, when the shielding was carried out at 0.25 mmPb, the dose appeared to be about 120% at 0.5 mm of the dermis surface, and the dose was decreased at the subsequent depth. Shielding at 0.5 mmPb, the dose appeared to be about 101% at the surface 0.5 mm, and the dose was measured to decrease at the subsequent depth. This result suggests that when lead aprons are actually used, the scattering rays would be sufficiently removed due to the spaces generated by the clothes and air, Therefore, the scattered ray generated from lead will not reach the human body. The ICRU defines the epidermis (0.07), in which the radiation-induced damage of the skin occurs, as the dose equivalent. If the radiation dose of the dermis is considered in addition, it will be helpful for the evaluation of the prognosis for radiation hazard of the skin.

Subcutaneous Temperature Estimation By Microwave Radiometry (Microwave Radiometry 원리를 이용한 생체 내부 온도 추정)

  • Kim, Kyeong-Seop;Lee, Jeong-Whan
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.357-364
    • /
    • 2006
  • Microwave Radiometry is the spectral measurement of eleclromagnetic radiation at frequency bands in the microwave region. One particular application of Microwave Radiometry is for analyzing temperature difffrentials of inside of human body to detect and diagnose pathologic conditions in which the temperature differentials are related with the symptoms of certain diseases. To accomplish this aim, we propose a new calibration method for estimating subcutaneous temperature by Microwave Radiometer and we also suggest a tumor-imitator phantom structure for simulating heat diffusion propagated by tissues around tumors to evaluate the discernment of brighuless temperature difffrentials.

Novel Flow Suppression Technique in MRI (핵자기 공명 영상에서 새로운 유속 흐름제거 방법)

  • Ro, Y.M.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.92-97
    • /
    • 1992
  • The pulsatile nature of blood flow makes artefacts in 2D Fourier transform image. Spatial presaturation is known to be effective in eliminating flow artefacts when the spin echo acquisition is employed. However. this method requires additional RF pulse and spoiling gradient for presaturation. In this paper a new flow saturation technique which does not require additional saturation-RF and gradient is proposed. The proposed technique is equivalent to the existing saturation technique but the elimination of the flow component is achieved by a pair of tailored $90^{\circ}-180^{\circ}$ RF pulses in tile spin echo sequence. By use of two tailored RF pulses with opposite phase polarity, a linear phase gradient is generated for those moving materials and consequently all the spins of moving materials become dephased thereby no signal is observable. Computer simulations and experimental results obtained using both a phantom and a human volunteer with a 2.0 T whole body system are also presented.

  • PDF

Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode (자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향)

  • Jeong, Woon-Chan;Joo, Young-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

Change of Proton Bragg Peak by Variation of Material Thickness in Head Phantom using Geant4 (Geant4 전산모사를 이용한 두개골 팬텀의 물질 두께 변동에 따른 양성자 브래그 피크의 위치 변화)

  • Kim, You Me;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.401-408
    • /
    • 2021
  • Proton therapy using the Bragg peak is one of the radiation therapies and can deliver its maximum energy to the tumor with giving least energy for normal tissue. A cross-sectional image of the human body taken with the computed tomography (CT) has been used for radiation therapy planning. The HU values change according to the tube voltage, which lead to the change in the boundary and thickness of the anatomical structure on the CT image. This study examined the changes in the Bragg peak of the brain region according to the thickness variation in the head phantom composed of several materials using the Geant4. In the phantom composed of a single material, the Bragg peak according to the type of media and the incident energy of the proton beams were calculated, and the reliability of Geant4 code was verified by the Bragg peak. The variation of the peak in the brain region was examined when each thickness of the head phantom was changed. When the thickness of the soft tissue was changed, there was no change in the peak position, and for the skin the change in the peak was small. The change of the peak position was mainly changed when the bone thickness. In particular, when the bone was changed only or the bone was changed together with other tissues, the amount of change in the peak position was the same. It is considered that measurement of the accurate bone thickness in CT images is one of the key factors in depth-dose distribution of the radiation therapy planning.

Effects of Breast Dose on Plain Abdominal Position (복부 방사선검사 자세가 유방선량에 미치는 영향)

  • Joo, Young-Cheol;Kim, Sheung-Hyuk
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.