• Title/Summary/Keyword: Human body impedance

Search Result 76, Processing Time 0.03 seconds

Wireless RF Sensor Structure for Non-Contact Vital Sign Monitoring

  • Kim, Sang-Gyu;Yun, Gi-Ho;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.37-44
    • /
    • 2012
  • This paper describes a compact and novel wireless vital sign sensor at 2.4 GHz that can detect heartbeat and respiration signals. The oscillator circuit incorporates a planar resonator, which functions as a series feedback element as well as a near-field radiator. The periodic movement of a human body during aerobic exercise could cause an input impedance variation of the radiator within near-field range. This variation results in a corresponding change in the oscillation frequency and this change has been utilized for the sensing of human vital signs. In addition, a surface acoustic wave (SAW) filter and power detector have been used to increase the system sensitivity and to transform the frequency variation into a voltage waveform. The experimental results show that the proposed sensor placed 20 mm away from a human body can detect the vital signs very accurately.

Case Studies for Potential Distribution due to Power Source by Environmental Condition (전원설비에 의한 공간조건별 전위분포 사례 연구)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.50-58
    • /
    • 2011
  • In this paper, potential distribution analysis through the six kinds of case studies examined in the environmental conditions change within a limited space, by the power supply system installed. To interpret the potential distribution using electromagnetic field analysis program and the parameters were state of the ground, the outer wall of the configuration state and the presence of human potential distribution was simulated. Potential distribution analysis, the size of nominal voltage, depending on the impedance of human body to be determined on the impact of surprise decision, but if equipped with appropriate protective equipment can be protected from lightning have been confirmed.

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

  • Yoo, Sun-K.
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.5
    • /
    • pp.601-605
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

Design of a Dual-Band On-Body Antenna for a Wireless Medical Repeater System (의료용 무선 중계 시스템용 이중 대역 인체 부착형 안테나 설계)

  • Kwon, Kyeol;Tak, Jinpil;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.239-246
    • /
    • 2013
  • In this paper, a dual-band on-body antenna operating at MICS and ISM band for a wireless medical repeater system is proposed and the antenna performance including the human body effect is investigated. The designed dual-band antenna is comprised of a top patch for ISM band and bottom patch for MICS band. Simulation and measurement was carried out in order to analyze the effects of human body on antenna performance considering real use. The proposed antenna has required impedance bandwidth enough to cover both MICS and ISM bands. The measured peak gains were -12.47 dBi and 1.71 dBi at the each center frequency of MICS and ISM bands, respectively. Furthermore, the antenna has the maximum radiation directed toward the inside of the human body in the MICS band and directed toward the outside in the ISM band. In addition, the return loss property of the antenna is insensitive to human body effects so that the proposed antenna is well suited for the on-body wireless medical repeater system.

Experimental investigation on the apparent mass during exposure to whole-body vertical vibration for Korean-seated postures (한국인 앉은 자세에 대한 수직방향의 전신진동 피폭에 대한 겉보기 질량의 실험적 연구)

  • 김영태;정완섭;윤용산
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.241-245
    • /
    • 2003
  • When considering the effects of whole-body vertical vibration, it is valuable to have an understanding of the mechanical characteristics (mechanical impedance and apparent mass) of the body. This paper addresses experimental results carried out to investigate the characteristics of apparent masses fer 41 Korean. The apparent masses of the seated human body in vertical direction were measured during different experimental conditions, such as vibration excitation level (0.5-2 ms$\^$-2/ r.m.s). frequency range (1-50Hz), and upper body posture (relaxed, normal and backrest-upright). We showed the average of all subjects and all conditions and compared the results with ISO5982/DIS (2000).

  • PDF

ELF 3D Magnetic Field and Eddy Current Calculation of Human Body Around Transmission Lines (송전선로 주변의 3차원 자기장 및 인체 유도 와전류 계산)

  • Myeong, Seong-Ho;Lee, Dong-Il;Sin, Gu-Yong;Han, In-Su;Park, Jong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.485-491
    • /
    • 2002
  • Since Wertheimer and Leeper reported possible adverse health effects of magnetic field in 1979, worldwide researches on this issue have been conducted. More recently, the U.S. Congress instructed the NIEHS (National Institute of Environmental Health Sciences), NIH (National Institute of Health) and DOE (Department of Energy) to direct and manage EMF RAPID (Electric and Magnetic Fields Research and Public Information Dissemination) program aimed at providing scientific evidence to clarify the potential for health risks from exposure to extremely low frequency electric and magnetic fields(ELF-EMF). Although they concluded that the scientific evidence suggesting adverse health risks of ELF-EMF is weak, the exposure to ELF-EMF cannot be recognized as entirely safe. Therefore, the purpose of this article is to describe magnetic field 3-D calculation and to evluate eddy current of human body compare to international guide line recognized one of the basic problems. In open boundary problem, Magnetic field using FEM is not advantageous in the point of the division of area and the proposition of the fictitious boundary. Therefore, we induced the analytic equation of magnetic field calculations so but the finite line segment based on Biot-Savarts law Also, Eddy currents induced due to ELF-EMF magnetic field are computed. To calculate induced currents, impedance method is used in this paper, An example model of human head with resolution of 1.27cm is used. In this paper, We evaluate the magnetic field and eddy current of human head around 765 kV transmission lines compare to international guide line.

Mathematical Model Development of Whole-body Vertical Vibration, Using a Simulated Annealing Method (Simulated Annealing 기법을 이용한 인체 수직 전신 진동 모델의 파라미터 선정)

  • Choi, Jun-Hee;Kim, Young-Eun;Baek, Kwang-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.381-386
    • /
    • 2000
  • Simple spring-damper-mass models have been widely used to understand whole-body vertical biodynamic response characteristics of the seated vehicle driver. However, most previous models have not considered about the non-rigid masses(wobbling masses). A simple mechanical model of seated human body developed in this study included the torso represented by a rigid and a wobbling mass. Within the 0.5-20Hz frequency range and for excitation amplitudes maintained below $5ms^{-2}$, this 4-degree-of-freedom driver model is proposed to satisfy the measured vertical vibration response characteristics defined from a synthesis of published data for subjects seated erect without backrest support. The parameters are identified by using the combinatorial optimization technique, simulated annealing method. The model response was found to be provided a closer agreement with the response characteristics than previously published models.

  • PDF

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Parameters: Pilot Study

  • Kim, Jae-Hyung;Shin, Beum-Joo;Baik, Seung-Wan;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.15-23
    • /
    • 2017
  • In this study, bioelectrical impedance analysis, which has been used to assess an alteration in intracellular fluid (ICF) of the body, was applied to detect intravenous infiltration. The experimental results are described as follows. Firstly, when infiltration occurred, the resistance gradually decreased with time and frequency i.e., the resistance decreased with increasing time, proportional to the amount of infiltrated intravenous (IV) solution. At each frequency, the resistance gradually decreased with time, indicating the IV solution (also blood) accumulated in the extracellular fluid (ECF) (including interstitial fluid). Secondly, the resistance ratio started to increase at infiltration, showing the highest value after 1.4 min of infiltration, and gradually decreased thereafter. Thirdly, the impedance ($Z_C$) of cell membrane decreased significantly (especially at 50 kHz) during infiltration and gradually decreased thereafter. Fourthly, Cole-Cole plot indicated that the positions of (R, $X_C$) shifted toward left owing to infiltration, reflecting the IV solution accumulated in the ECF. The resistance ($R_0$) at zero frequency decreased continuously over time, indicating that it is a vital impedance parameter capable of detecting early infiltration during IV infusion. Finally, the mechanism of the current flowing through the ECF, cell membrane, and ICF in the subcutaneous tissues was analyzed as a function of time before and after infiltration, using an equivalent circuit model of the human cell. In conclusion, it was confirmed that the infiltration could be detected early using these impedance parameters during the infusion of IV solution.

A measurement of signal transmission parameters in human muscle (인체 근육에 있어서 신호 전송계수의 계측)

  • Lee, Hyun-Chul;Lee, Seung-Ju;Kim, Ki-Young;Yoon, Chae-Hyun;Yoon, Yang-Woung;Park, Hyung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2699-2701
    • /
    • 2002
  • In this study, a system for measurement of impedance (transmission parameter) on the human muscle was constructed. The system composed of the stimulating part for input with milli-voltage and the measuring part for measurement of transmission voltage in human muscle. As a result of this experiment, the frequency characteristic of each subject represent that the transmission voltage goes up in spite of a constant input voltage according to frequency (1Hz -50kHz) increment. Namely, the amplitude of input signal was not reflected but frequency was reflected on the measured results. This result be estimated that the proposed system is able to measure passive electrical characteristic of human body.

  • PDF

A Measurement System for Color Environment-based Human Body Reaction (색채 환경 기반의 인체 반응 정보 측정 시스템)

  • Kim, Ji-Eon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.2
    • /
    • pp.59-65
    • /
    • 2016
  • The result of analyzing the cognitive reaction due to the color environment has been applied to various filed especially in medical field. Moreover, the study about the identification of patient's condition and examination the brain activity by collecting the bio-signal based on the color environment is being actively conducted. Even though, there were a variety of experiments by convention the color environment using a light or LED color, it still has a problem that affects the psychological information. Therefore, our proposed system using a HMD (Head Mounting display) to provide a completed color environment condition. This system uses the BMS(Biomedical System) to collect the biometric information which responds to the specific color condition and the human body response information can be measured by the development the Memory and Attention test on Mobile phone. The collection of Biometric information includes electro cardiogram(ECG), respiration, oxygen saturation (Sp02), Bio-impedance, blood pressure will store in the database. In addition, we can verify the result of the human body reaction in the color environment by Memory and Attention application. By utilizing the reaction of the human body information that is collected thought the proposed system, we can analyze the correlation between the physiological information and the color environment. And we also expect that this system can apply to the medical diagnosis and treatment. For future work, we will expand the system for prediction and treatment of Alzheimer disease by analyzing the visualization data through the proposed system. We will also do evaluation on the effectiveness of the system for using in the rehabilitation program.