• Title/Summary/Keyword: Human Thigh Model

Search Result 15, Processing Time 0.023 seconds

A study on procedure for classifying male muscular lower body somatotype from general anthropometric database

  • Lee, Minji;Chun, Jongsuk
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.4
    • /
    • pp.585-595
    • /
    • 2013
  • The most researches developing pattern of compression style sportswear were targeted at the live model that has muscular body build. The purpose of this study was developing a method for classifying men's lower body types in terms of muscular body build. The 3D human body scan data and body measurements of 30s of Size Korea were analyzed. The subjects (n=203) were men between the ages of 30 and 39 years. Men's muscular body build was classified with two key dimensions, thigh girth and calf girth. The subjects were divided into four groups. From each group, average subjects (n=42) whose height and weight were close to the mean value ($mean{\pm}1/2$ S.D.) were selected. 42 subjects were divided up as four groups. Group I (n=7) was thigh and calf developed body type. Group II (n=9) was thigh developed body type. Group III (n=11) was calf developed body type. Group IV (n=15) was thigh and calf undeveloped body type. Four groups had distinct different at widths (n=4), depths (n=4), and girths (n=9) dimensions. The results showed that the muscular men in their 30s could be defined by thigh and calf girths. The thigh developed muscular men had thigh girth over 60cm and the calf developed muscular men had calf girth over 38cm. From each group one representative was selected by 3D body scan figure.

A Statistical Model for Marker Position in Biomechanics

  • Kim, Jinuk
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.1
    • /
    • pp.67-74
    • /
    • 2017
  • Objective: The purpose of this study was to apply a general linear model in statistics to marker position vectors used to study human joint rotational motion in biomechanics. Method: For this purpose, a linear model that represents the effect of the center of hip joint rotation and the rotation of the marker position on the response was formulated. Five male subjects performed hip joint functional motions, and the positions of nine markers attached on the thigh with respect to the pelvic coordinate system were acquired at the same time. With the nine marker positions, the center of hip joint rotation and marker positions on the thigh were estimated as parameters in the general linear model. Results: After examining the fitted model, this model did not fit the data appropriately. Conclusion: A refined model is required to take into account specific characteristics of longitudinal data and other covariates such as soft tissue artefacts.

Development of Three-Dimensional Contact Model of Human Knee Joint During Locomotion (보행 중 인체 슬관절의 3차원 접촉 모델 개발)

  • Kim, Hyo-Shin;Park, Seong-Jin;Mun, Joung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.182-189
    • /
    • 2005
  • The human knee joint is the intermediate joint of the lower limb that is the largest and most complex joint in the body. Understanding of joint-articulating surface motion is essential for the joint wear, stability, mobility, degeneration, determination of proper diagnosis and so on. However, many studies analyzed the passive motion of the lower limb because of the skin marker artefact and some studies described medial and lateral condyle of a femur as a simple sphere due to the complexity of geometry. Thus, in this paper, we constructed a three-dimensional geometric model of the human knee from the geometry of its anatomical structures using non-uniform B-spline surface fitting as a study for the kinematic analysis of more realistic human knee model. In addition, we developed and verified 6-DOF contact model of the human knee joint using $C^2$ continuous surface of the inferior region of a femur, considering the relative motion of shank to thigh during locomotion.

Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model (대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석)

  • Choi, Ho-Seon
    • The Journal of Information Technology
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

Assessment of Wear Comfort of Water-vapor-permeable (WVP) garments (투습방수의류의 착용쾌적성 평가)

  • Kang, In-Hyeng;Park, Hyo-Suk;Lee, Han-Sup
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.9
    • /
    • pp.928-939
    • /
    • 2012
  • This study evaluates wear comforts of water-vapor-permeable (WVP) garments through a measurement of various parameters such as skin and rectal temperatures, microclimate between skin and clothing, sweat rate, and subjective sensations (thermal, wet and comfort sensations) to correlate the physiological responses of the human body with its comfort feeling. Wear comfort during a specific exercise on a treadmill in a climatic chamber (temperature T = $20{\pm}0.5^{\circ}C$ and relative humidity H = $50{\pm}10%$) were studied using eight men wearing seven sportswear outfits (a long sleeve shirts and a long pants) made with seven different WVP fabrics. A comfort sensation was found to be highly correlated with skin T (p<.001), microclimate (T and H) between skin and clothing (p<.001) and sweat rate (p<.05). A regression model correlating comfort sensations and physiological responses obtained from wearer trials could be established: Y = 14.167 - 0.362 ${\times}$ X1 + 0.424 ${\times}$ X2 - 0.238 ${\times}$ X3 - 0.561 ${\times}$ X4 + 0.253 ${\times}$ X5 + 0.214 ${\times}$ X6 - 0.393 ${\times}$ X7 + 0.023 ${\times}$ X8 - 0.043 ${\times}$ X9. (Y = comfort sensation, X1 = forehead skin T, X2 = forearm skin T, X3 = hand skin T, X4 = thigh skin T, X5 = T of chest microclimate, X6 = T of thigh microclimate, X7 = chest sweat rate, X8 = H of back microclimate, X9 = H of thigh microclimate. The regression model obtained in this work can be used by manufacturers to objectively estimate the comfort sensation of sportswear before it is introduced to the consumer market. This study provides salient information to sportswear manufacturers and sportswear consumers.

Analysis of human gait using inverse kinematics (역기구학을 이용한 보행 분석)

  • 최경암;정민근;염영일
    • Journal of the Ergonomics Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.3-14
    • /
    • 1994
  • In this study, the human gait trajectories during normal walking were synthesized using the inverse kinematics and optimization techniques. The synthesis is based on a gait model consisting of a torso and two legs. Each let has three segments: thigh, shank, foot, and has six degrees-of-freedom. In order to synthesize trajectories of this redundant system, the sum of angular displacements of articulating joints was selected as an objective function to be minimized. The proposed algorithm in this study is very useful for the analysis of human gait. For the gait analysis, the trajectories of four points in each leg should be measured. Hpwever, by using the algorithm, measuring the trajectories of two points is sufficient, and thus the experimental set-up can be simplified.

  • PDF

역기구학을 이용한 보행분석

  • 최경임;정민근;염영일
    • Proceedings of the ESK Conference
    • /
    • 1994.04a
    • /
    • pp.136-144
    • /
    • 1994
  • In this study, the human gait trajectories during normal walking were synthesized using the inverse kinematics and optimization techniques. The synthesis based on a lower extremity model consisting of a torso and two legs. Each leg has three segments: thigh, shank, foot, and is assumed to move with six degrees-of-freedom. In order to synthesize trajectiories of this redundant system, the sum of angular displacements of articulating joints was selected as an objective function to be minimized. The proposed algorithm in this study is very useful for the analysis of human gait. For the gait analysis, the trajectories of four points in each leg should be measured. However, by using the algorithm, measuring the trajectories of two points is sufficient, and thus the experimental set-up can be simplified. The predicted joint trajectories showed a good agreement with those obtained from the experiment. The statistical analysis and graphic simula- tions are also presented.

  • PDF

The Comparison on the Compression Measurement Value of Medical Compression Stockings (수입 의료용 압박스타킹의 압력 측정치 비교)

  • Do, Wol-Hee;Kim, Nam-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.8
    • /
    • pp.1060-1074
    • /
    • 2013
  • This study measured and analyzed pressure at each measurement part of imported compression stockings sold in Korea to provide basic information to establish a pressure standard and grade ranking. This study used 40 medical compression stockings imported from 6 countries. Pressure measurements were taken at 11 points: front side and back side of ankle, end-point of the gastrocnemius muscle, front, inner side, back, and outer side of calf, back side of below knew girth, inner side, and outer side of mid-thigh girth, and inner side of thigh girth. AMI 3037-10 and AMI 3037-2 were used for measurements taken inside an environmental chamber at a temperature of $21^{\circ}C$ and a relative humidity (RH) of 65%. For the measurements, 11 air pack sensors were attached to a wooden model leg (Hohenstein) and three measurements were taken at each measurement point in three minutes. The average of these measurements was used for analysis. The findings of this study were as follows. As for the front side of the ankle, of the 40 products, 14 products (6 USA, 2 Swiss, 3 Italian, and 2 Taiwanese) were within the pressure range indicated on the product label; however, no German products fell within the pressure range. A total of 8 products (5 USA, 1 Swiss, 1 Italian, and 1 German) were gradient compression type; however, no Japanese or Taiwanese product were of this type. The majority of products had the highest pressure at the end-point of the gastrocnemius muscle. Only 3 products, 1 USA (Jobst Opaque 30-40mmHg), 1 Swiss (Sigvaris Cotton 34-46mmHg) and 1 Italian (Jobstocking 25-32mmHg), had measurements that met the indicated standard pressure, were a gradient compression type, and met the overall standard for compression stockings.

Generation of Motor Velocity Profile for Walking-Assistance System Using Humanoid Robot Model (휴머노이드 로봇 모델을 이용한 보행재활 훈련장치의 견인모터 속도 파형 생성)

  • Choi, Young-Lim;Choi, Nak-Yoon;Park, Sang-Il;Kim, Jong-Wook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.5
    • /
    • pp.631-638
    • /
    • 2012
  • This work proposes a new method to generate velocity profile of a traction motor equipped in a rehabilitation system for knee joint patients through humanoid robot simulation. To this end, a three-dimensional full-body humanoid robot model is newly constructed, and natural human gait is simulated by applying to it reference joint angle trajectories already published. Linear velocity is derived from distance data calculated between the positions of a thigh band and its traction motor at every sampling instance, which is a novel idea of this paper. The projection rule is employed to kinematically describe the humanoid robot because of its high efficiency and accuracy, and measured joint trajectories are used in simulating human natural gait referring to Winter's book. The attained motor velocity profile for a certain position in human body will be applied to our walking-assistance system which is implemented with a treadmill system.

Study on input data for developing virtual fitting model at internet apparel shopping sites and comparison of the results (인터넷 의류 판매 사이트의 가상피팅모델 구축을 위한 입력정보 종류와 결과 비교)

  • 천종숙;최현영
    • Science of Emotion and Sensibility
    • /
    • v.5 no.4
    • /
    • pp.1-10
    • /
    • 2002
  • A web based virtual try-on provides customers a more enjoyable shopping experience that visualize clothes on personal mannequin. The researchers compared virtual fitting models which were developed in 2000 at Korea and in 2000 and 2002 at U.S. The results of this study as follows: The information about user's body size was required to input for selection of a virtual fitting model. 7 to 19 different body size, shape, and face features including weight and height were needed for visualizing virtual fitting model. The body type of the U.S virtual fitting model(My virtual model) was selected by front view silhouette for women, and by shoulder width and midriff silhouette for men. The more detailed information was required for developing Korean virtual fitting model. The additional body size information required in the site were leg and arm lengths, waist length, and thigh and ankle circumferences. The body proportion of Korean cyber personal mannequin was longer and narrower than the U.S cyber personal mannequin. It was recommended that standardized body length, width, and depth proportions calculated from national anthropometric data must be applied for developing Korean virtual fitting model. With application of more detailed information on face feature and advanced graphic image technology the 'My virtual model in 2002 resembled the human body shape of various race.

  • PDF