Effects of RF Exposure on Human Physiology by CDMA Cellular Phones (CDMA 휴대전화 전자파에 의한 생리학적 변화)

  • Nam Ki-Chang;Kim Sung-Woo;Kim Soo-Chan;Kim Deok-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.5 s.96
    • /
    • pp.511-517
    • /
    • 2005
  • Many cellular phone volunteer studies have been conducted since such a social issue is raised that the long time usage of cellular phone by teenagers may increase health risk. While there were various adult volunteer studies using GSM cellular phone on heart rate and blood pressure, very few teenager studies using CDMA phone were conducted. In this study, two volunteer groups of 21 teenagers and 21 adults were exposed to 300 mW CDMA wave for half an hour, and the physiological parameters such as blood pressure, heart rate, respiration rate, and skin impedance were investigated. All the parameters fur both groups were unaffected during exposure except the skin impedance of teenager group.

Investigation on Hydration Process and Biocompatibility of Calcium Silicate-Based Experimental Portland Cements

  • Lim, Jiwon;Guk, Jae-Geun;Singh, Bhupendra;Hwang, Yun-Chan;Song, Sun-Ju;Kim, Ho-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.4
    • /
    • pp.403-411
    • /
    • 2019
  • In this work, the hydration process and cytotoxicity of lab-synthesized experimental Portland cements (EPCs) were investigated for dental applications. For this purpose, EPCs were prepared using laboratory-synthesized clinker constituents, tricalcium silicate (C3S), dicalcium silicate (C2S), and tricalcium aluminate (C3A). C-A was prepared by the Pechini method, whereas C3S and C2S were synthesized by solid-state reactions. The phase compositions were characterized by X-ray diffraction (XRD) analysis, and the hydration process of the individual constituents and their combinations, with and without the addition of gypsum, was investigated by electrochemical impedance spectroscopy (EIS). Furthermore, four EPC compositions were prepared using the lab-synthesized C-A, C3S, and C2S, and their hydration processes were examined by EIS, and their cytotoxicity to HPC and HIPC cells were tested by performing an XTT assay. None of the EPCs exhibited any significant cytotoxicity for 7 days, and no significant difference was observed in the cell viabilities of ProRoot MTA and EPCs. The results indicated that all the EPCs are sufficiently biocompatible with human dental pulp cells and can be potential substitutes for commercial dental cements.

Obstacle avoidance of Mobile Robot with Virtual Impedance (가상임피던스를 이용한 원격 이동로봇의 장애물회피)

  • Jin, Tae-Seok
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.4
    • /
    • pp.451-456
    • /
    • 2009
  • In this paper, a virtual force is generated and fed back to the operator to make the teleoperation more reliable, which reflects the relationship between a slave robot and an uncertain remote environment as a form of an impedance. In general, for the teleoperation, the teleoperated mobile robot takes pictures of the remote environment and sends the visual information back to the operator over the Internet. Because of the limitations of communication bandwidth and narrow view-angles of camera, it is not possible to watch certain regions, for examples, the shadow and curved areas. To overcome this problem, a virtual force is generated according to both the distance between the obstacle and the robot and the approaching velocity of the obstacle w.r.t the collision vector based on the ultrasonic sensor data. This virtual force is transferred back to the master (two degrees of freedom joystick) over the Internet to enable a human operator to estimate the position of obstacle at the remote site. By holding this master, in spite of limited visual information, the operator can feel the spatial sense against the remote environment. It is demonstrated by experiments that this collision vector based haptic reflection improves the performance of teleoperated mobile robot significantly.

Relationship Between Skin Impedance Signal, Reaction time, and Eye Blink Depending on Arousal Level (각성상태에 따른 피부임피던스 신호와 반응시간 및 눈 잡학임의 상관관계(E))

  • 고한우;김연호
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.485-491
    • /
    • 1997
  • This paper describes the relationship between skin impedance signal, behavioral signal, and subjective evaluation depending on arousal level. Nz and reaction time had similar trend with mKSS level, but eyeblink rate was different from these two parameters. eye-blink rate increased slowly from mKSS level 1 to 5, and had high increasing rate at mKSS 7. But it showed steep descent at mKSS level 9. Each subject showed different eye-blink rates, but changing rates of EBR was similar at eachm KSS level. Therefore it suggests that rising rate of EBR can be used arousal level criterion. From the result of reaction time test. human performance was decreased rapidly above the mKSS level 5, and false positive and false negative data was observed above the mKSS level 3. It is desirable to give a subject some stimuli such as sound or aroma to rise arousal level between mKSS level 3 and mKSS level 5.

  • PDF

Analysis of Meridian Response by Sound Stimulus in Body (음향 자극에 의한 인체 경락의 반응분석)

  • Kim, Yong-Chin;Jeong, Dong-Myong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.3
    • /
    • pp.47-54
    • /
    • 2001
  • This study is to analyze the impedance response in human body by acoustic stimulation on acupoints and contrast parte; for objectification of the meridian substance. It is to verify meridian pathway and channel theory or bio-energy in body. This paper proposes to make an hypothesis about the underground water theory. The meridian has not tube or pipe line type channel but bio-energy flow along the channel similar to flowing pattern of underground water in body. It was analyzed the current characteristic or impedance response after acoustic stimulation by sound wave of 5 specific tones. The response characteristics of current stimulation are measured by the average current magnitude and variation ratio or meridian. The current variation ratio or Live Meridian(gung) 33.2%, Heart Meridian(sang) 30.7% Kidney Meridian (gak) 33.1%, Spleen Meridian(chi) 33.9%, Lung Meridian (wo) 30.7% are to be compared to contrast parts (non-acupoint and meridian). In experimental results, meridian is discrimination to non-meridian, and 5 vital meridians have a reciprocal relationship with sound wave of 5 specific tones.

  • PDF

Design and SAR Analysis of Wearable Antenna on Various Parts of Human Body, Using Conventional and Artificial Ground Planes

  • Ali, Usman;Ullah, Sadiq;Khan, Jalal;Shafi, Muhammad;Kamal, Babar;Basir, Abdul;Flint, James A;Seager, Rob D.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.317-328
    • /
    • 2017
  • This paper presents design and specific absorption rate analysis of a 2.4 GHz wearable patch antenna on a conventional and electromagnetic bandgap (EBG) ground planes, under normal and bent conditions. Wearable materials are used in the design of the antenna and EBG surfaces. A woven fabric (Zelt) is used as a conductive material and a 3 mm thicker Wash Cotton is used as a substrate. The dielectric constant and tangent loss of the substrate are 1.51 and 0.02 respectively. The volume of the proposed antenna is $113{\times}96.4{\times}3mm^3$. The metamaterial surface is used as a high impedance surface which shields the body from the hazards of electromagnetic radiations to reduce the Specific Absorption Rate (SAR). For on-body analysis a three layer model (containing skin, fats and muscles) of human arm is used. Antenna employing the EBG ground plane gives safe value of SAR (i.e. 1.77W/kg<2W/kg), when worn on human arm. This value is obtained using the safe limit of 2 W/kg, averaged over 10g of tissue, specified by the International Commission of Non Ionization Radiation Protection (ICNIRP). The SAR is reduced by 83.82 % as compare to the conventional antenna (8.16 W/kg>2W/kg). The efficiency of the EBG based antenna is improved from 52 to 74 %, relative to the conventional counterpart. The proposed antenna can be used in wearable electronics and smart clothing.

The Hazardous Components and Prevailing Rate of Sarcopenic Obesity in Younger Women : Based on 2008-2011 Korean National Health and Nutrition Examination Surveys

  • Jongseok Hwang;Chang-Ryeol Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.1-10
    • /
    • 2024
  • Purpose : Sarcopenic obesity is associated with adverse health consequences in females. Nevertheless, there has been limited research on the hazardous components and prevailing rates of sarcopenic obesity among younger women. This study aimed to identify the hazardous components and prevailing rates of sarcopenic obesity in younger females. Methods : This study utilized data based on 2008~2011 from the Korea National Health and Nutrition Examination Surveys by the centers for disease control and prevention. The analysis was concentrated on a subset of 1,520 women aged between 30 and 39 years of age. The participants answered a questionnaire to gather demographic information. They then underwent a physical examination to measure the human detention variables, which was conducted utilizing bioelectrical impedance analysis. The blood pressure and blood laboratory tests were determined using established laboratory protocols for evaluating blood parameters. Results : This study included 1,520 patients aged 30~39 years old. The mean age of the participants was 34.97 (years)±2.74 and the overall prevailing rate was 1.84 %. The hazard components in human dimensions were the height, weight, body mass index (BMI), waist circumference (WC) and skeletal muscle mass index (SMI). The hazard components in biochemical and blood pressure were high fasting glucose, increased triglyceride, elevated total cholesterol, high systolic blood pressure, and increased diastolic blood pressure with p-values <.05. Conclusion : This study examined the hazardous components and prevailing rates of sarcopenic obesity in younger women living in the community. The results contribute to the current body of knowledge on sarcopenic obesity and shed light on possible hazardous components in a younger female population. Based on these findings, there should be increased health and medical attention towards the prevention, management, and health promotion related to reducing risk factors for sarcopenic obesity in younger women.

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

ATPDraw Simulation for Transient Phenomena Analysis of Electrical Shock Underwater (수중 전격 과도현상 해석을 위한 ATPDraw 시뮬레이션)

  • Jung, Jong-Wook;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.48-54
    • /
    • 2007
  • This paper describes the analysis of transient phenomena on the point that a human body suffers an electrical shock. A couple of case studies were discussed by using an ATPDraw simulation tool. Two models for the case studies were constructed on the assumption that the electrical shock event takes place under water to simulate the severest condition ; the first model that the human body contacts with an energized part exposed to water ; the second model that both hands and feet simultaneously contact with the ground under water. After modeling, the transient phenomena for the models were analyzed by comparing the voltages and currents calculated at each part of the human body. As a result steep front kicks in voltage and current were observed as transient phenomena on the point that the human body contacts with the energized part exposed to water in the first model and the magnitudes of the kicks considerably increased. It was considered however, the effect of the kicks due to the commercial power source on the human body could be neglected because the product of the current through the body and the short duration is less than the safety limit. When both hands and feet simultaneously contact with the ground in the second model, the voltage generally decreased all over the body parts, while the current flowing through the chest abruptly increased. The duration of this current was very shot, as well, thus its effect on the electrical shock is considered insignificant. After all, it was confirmed through the simulation results that the electrical shock depends on the magnitude in voltage and the body impedance.

Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model (대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석)

  • Choi, Ho-Seon
    • The Journal of Information Technology
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF