• Title/Summary/Keyword: Human Body Detection

Search Result 208, Processing Time 0.023 seconds

Evaluation of Setup Usefulness of CBCT using Rando Phantom (인체 팬텀(Rando Phantom)을 이용한 CBCT의 Setup 유용성 평가)

  • Jang, Eun-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.7
    • /
    • pp.234-238
    • /
    • 2011
  • This paper will evaluate the usefulness of 3D target of CBCT by comparing human body's posture and position when simulated treatment is being carried out as well as human phantom posture and position using CBCT which is applying OBI. From the Rando Phantom which is located in the datum point moved in parallel and rotationary direction using CBCT. Then the mean and standard deviation difference on images location difference that are acquired were compared with real the Rando Phantom' moved distance. To make a plan of simulated treatment with the same procedure of real radiation therapy, we are going to setup the Rando Phantom. With an assumption that the position is set in accurate place, we measured the setup errors accroding to the change of the translation and rotation. Tests are repeated 10 times to get the standard deviation of the error values. The variability in couch shift after positioning equivalent to average residual error showed lateral $0.2{\pm}0.2$mm, longitudinal $0.4{\pm}0.3$mm, vertical $-0.4{\pm}0.1$mm. The average rotation erroes target localization after simulated $0.4{\pm}0.2$ mm, $0.3{\pm}0.3$ mm, and $0.3{\pm}0.4$ mm. The detection error by rotation is $0{\sim}0.6^{\circ}$ CBCT 3D/3D matching using the Rando Phantom minimized the errors by realizing accurate matching during simulated treatment and patient caring.

Bioequivalence of Two Nilvadipine Tablet (닐바디핀 정제에 대한 생물학적 동등성 평가)

  • 김종국;이사원;최한곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.3
    • /
    • pp.289-295
    • /
    • 1998
  • The bioequivalence of two nilvadipine products was evaluated in 16 normal male volunteers (age 22-32 yr, body weight 57-80 kg) following sidle oral dose. Test product was Overca $l_{R}$ tablet (Choong-Wae Pharm. Corp., Korea) and reference product was Nivadi $l_{R}$ tablet (Hyundai Pharm. Corp., Korea). Both products contain 4 mg of nilvadipine. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of nilvadipine was accomplished using a validated capillary column GC with electron-capture detection. As a result of the assay validation, the quantiflcation of nilvadipine in human plasma by this technique was possible down to 0.5 ng/ml using 1 ml of plasma. Absolute overall recovery from five replicate analyses of nilvadipine-spiked sample were 88.4$\pm$ 10.24% (mean$\pm$ 5.D.) for human plasma of 10 ng/ml. The coefficients of variation (C.V.) were less than 20% and the actual concentration of nilvadipine measured by GC ranged from 80 to 99% in all plasma. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05); the area under the curve from time zero to 8 hr (AUCo-$_{8 hr}$) (22.8$\pm$5.90 vs 22.2$\pm$6.10 ng . hr/ml), maximum plasma concentration ( $C_{max}$) (10.0$\pm$2.85 vs 9.3$\pm$3.28 ng/ml) and time to reach maximum plasma concentration ( $T_{max}$) (1.2$\pm$0.31 vs 1.3 $\pm$0.47 hr). The differences of mean AU $Co_{8hr}$ $C_{max}$, and $T_{max}$ between the two products (2.25, 7.65, and 10.30%, respectively) were less than 20%. The power (1-$\beta$) and treaeent difference (7) for AU $Co_{8hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectively. Although the power for Tmax was under 0.8, Tm\ulcorner of the two products was not significantly different from each other (p>0. 05). These results suggest that the bioavailability of Overeat tablet is not significantly different from that of Nivadil tablet. Therefore, two products are bioequivalent based on the current results.sults.lts.lts.lts.

  • PDF

Evaluation of the Genetic Toxicity of Synthetic Chemicals (XI) - a Synthetic Sulfonylurea Herbicide, Pyrazosulfuron-ethyl-

  • Ryu, Jae-Chun;Kim, Eun-Young;Kim, Young-Seok;Yun, Hye-Jung
    • Environmental Mutagens and Carcinogens
    • /
    • v.24 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • To validate and to estimate the chemical hazard playa very important role to environment and human health. The detection of many synthetic chemicals including agrochemicals that may pose a genetic hazard in our environment is of great concern at present. Since these substances are not limited to the original products, and enter the environment, they have become widespread environmental pollutants, thus leading to a variety of chemicals that possibly threaten the public health. Pyrazosulfuron-ethyl [Ethyl-5-(4,6-dimethoxypyrimidin-2-ylcarbamoylsulfamoyl)-1-methylpyrazole-4-carboxylate, $C_{14}H_{18}N{6}O_{7}S,$ M.W. =414.39, CAS No. 93697-74-6], is one of well known rice herbicide belong in the sulfonyl urea group. To clarify the genotoxicity of this agrochemical, Ames bacterial reversion assay, in vitro chromosomal aberration assay with Chinese hamster lung (CHL) fibroblast and bone marrow micronucleus assay in mice were subjected. In Ames assay, although pyrazosulfuron-ethyl revealed cytotoxic at 5,000-140 $\mug/plate$ in Salmonella typhimurium TA100, no dose-dependent mutagenic potential in 4.4~70 $\mug/plate$ of S. typhimurium TA 98, TA 100, TA1535 and TA 1537 both in the absence and presence of S-9 metabolic activation system was observed. Using CHL fibroblasts, the 50% cell growth inhibition concentration $(IC_{50})$ of pyrazosulfuron-ethyl was determined as 1,243 $\mug/mL,$ and no chromosomal aberration was observed both in the absence and presence of S-9 mixture in the concentration range of 311-1,243 $\mug/mL.$ And also, in vivo micronucleus assay using mouse bone marrow, pyrazosulfuron-ethyl revealed no remarkable induction of MNPCE (micronucleated polychromatic erythrocytes/1000 polychromatic erythrocytes) in the dose range of 625-2,500 mg/kg body weight when administered orally. Consequently, Ames bacterial gene mutation with Salmonella typhimurium, in vitro chromosome aberration with mammalian cells and in vivo bone marrow micronucleus assay revealed no clastogenic potential of pyrazosulfuron-ethyl in this study.

  • PDF

Detection of Heartbeat and Respiration Signal Using the Aircushion and the Frequency Domain Filter (에어쿠션 및 주파수 영역 필터를 이용한 호흡 및 심박 신호 검출)

  • Kim, Joo-Han;Cho, Sung-Pil;Shin, Jae-Yeon;Lee, Jeon;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.33-42
    • /
    • 2010
  • In this study, we have proposed a simple cardiorespiratory monitoring method based on displacements of human body which occurs due to periodic heartbeat and breathing. The proposed system consists of an aircushion, pressure sensing hardware and heartbeat and respiration signals extraction algorithm. The aircushion was used for unconstrained measurement of the respiration and heartbeats without a sensor attached on the subject's skin surface. The displacements of subject sitting on the aircushion cause small pressure variations. These variations are amplified and filtered with the pressure sensing hardware. Finally, heart rate and respiration rate are extracted by signal processing algorithm based on frequency domain filter. To evaluate the performance, extracted respiration and heart rate from proposed system were compared with conventional methods. The average sensitivity of respiration and heart rate are 98.67% and 99.24%, respectively. These results show the proposed method has advantages of installing and processing simplicity so as to be used easily in unconstrained respiration and heart rate monitoring in daily life.

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.

Analytical trends in mass spectrometry based metabolomics approaches of neurochemicals for diagnosis of neurodegenerative disorders (퇴행성신경질환의 진단을 위한 신경전달물질 대사체의 질량 분석법 동향)

  • Lee, Na-Kyeong;Jeon, Won-Jei;Jeong, Seung-Woo;Byun, Jae-Sung;Lee, Wonwoong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.355-378
    • /
    • 2017
  • Because neurochemicals are related to homeostasis and cognitive and behavioral functions in human body and because they enable the diagnosis of numerous neurodegenerative disorders, there has been increasing interest in the development of analytical platforms for neurochemical profiling in biological samples. In particular, mass spectrometry (MS)-based analytical methods combined with chromatographic separation have been widely used to profile neurochemicals in metabolic pathways. However, development of delicate sample preparation procedures and highly sensitive instrumental detection is necessary considering the trace levels and chemical instabilities of neurochemicals in biological samples. Therefore, in this review, analytical trends in MS-based metabolomics approaches to neurochemicals in multiple biological samples, such as urine, blood, CSF, and biological tissues, are discussed. This paper is expected to contribute to the development of an analytical platform to discover biomarkers that will aid diagnosis, prognosis, and treatment of neurodegenerative disorders.

Basic Properties of Stones used for Cooking Utensils and Their Leaching Characteristics for Heavy Metal Elements (조리용구용 석재의 기초 특성과 중금속 원소의 용출 특성)

  • 진호일;김신자;김복란;민경원
    • Economic and Environmental Geology
    • /
    • v.35 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • Dominant rock types of stones used presently for cooking utensils in Korea are pyroxenite, breccia and biotite diorite. Pyroxenite and biotite diorite relatively abundant in mafic minerals have higher specific gravities of 3.0 than breccia of 2.5. Breccia shows the highest absorption (2.9%) among three stones used as cooking utensils and pH value of three stone types shows the alkaline range of 9.7 to 9.9. Among the studied stones used for cooking utensils, biotite diorite is the most durable against abrasion and has the highest strength and therefore, it is expected to be used effectively for the longest time except for other specific causes. Heavy metals such as Cu, Pb, Co, Cr and Ni were leached lower than their detection limit (0.1 ppm) regardless of reaction time and initial pH value of solution. But the leached contents of Fe are various with rock types and leaching conditions and those by acidic solution are generally 1.8 to 31 times higher than those by neutral solution. Breccia and biotite diorite show the highest leached content of Fe in cases of neutral and acidic solutions, respectively. Standard criteria of leached heavy metals and macrominerals should be studied thoroughly to utilize stones for cooking utensils of high quality which are harmless to the human body. Also it is required to examine mon detailed abiochemical properties of various stone types used for cooking utensils.

Monitoring of Methanol Levels in Commercial Detergents and Rinse Aids (시판 세척제 및 헹굼보조제 중 메탄올 함량 모니터링)

  • Park, Na-youn;Yang, Heedeuk;Lee, Jeoungsun;Kim, Junghoan;Park, Se-Jong;Choi, Jae Chun;Kim, MeeKyung;Kho, Younglim
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.263-268
    • /
    • 2019
  • Methanol is a toxic alcohol used in various products such as antifreeze, detergent, disinfectant and industrial solvent. In the human body, methanol is oxidized to formaldehyde and formic acid, which can lead to metabolic acidosis, optic nerve impairment, and death. In this study, the methanol levels in detergents (n=191) and rinse aids (n=13) were analyzed by gas chromatography-headspace-mass spectrometry (GC-HS-MS). Limit of detection was 1.09 mg/kg, accuracy and precision were 91.1-97.9% and <10%, and it was suitable for quantitative analysis. This analysis method was simple and fast with a higher recovery rate than the conventional MFDS (Ministry of Food and Drug Safety) method of diluting the sample in water and putting it in a headspace vial.

Analysis of Minimum Detectable Activity Concentration of Water Samples and Evaluation of Effective Dose (물 시료의 최소검출가능 농도 분석과 유효선량 평가)

  • Jang, Eun-sung;Kim, Yang-su;Lee, Sun-young;Kim, Jung-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.857-862
    • /
    • 2020
  • In March 2011, a tsunami off Japan caused radioactive material that had seeped into the sea from the Fukushima nuclear accident to flow to the Pacific Ocean, causing pollution to sea life. For a comparative evaluation with the area surrounding the site of a nuclear power plant by the release of radioactive materials, an area 20 to 30 km away from the emergency protection plan area was selected as a comparative point considering weather conditions, population distribution, etc. In addition, the government intends to analyze the minimum detection radiation received by residents around the nuclear power plant and evaluate the effective dose. Analysis of tritium radiation from water samples showed that most of the samples were not detected and that 0.0014 % to 0.777 % of the annual legal standard of 1 mSv for the general public had little effect on the human body. Therefore, the measurement and analysis of water samples around the nuclear power plant site is expected to help relieve anxiety, such as exposure to the general public and neighboring residents due to radiation release.

Analysis Method of Surfactants for Identification of Residue Dishwashing Detergent (세척제 잔류량 확인을 위한 계면활성제 분석법 확립)

  • Park, Na-Youn;Lee, Sojeong;Kim, Jung Hoan;Kho, Younglim
    • Journal of the Korean Chemical Society
    • /
    • v.65 no.6
    • /
    • pp.433-440
    • /
    • 2021
  • Surfactants are organic compounds that have both hydrophilic and non-polar parts in one molecule, classified as non-ion, anion, cation, and amphoteric surfactants according to the charge of hydrophilic parts in aqueous state. A trace amounts may remain when vegetables and fruits are washed using type1 detergent (Vegetable and fruit detergent), and there is a possibility of exposure to the human body through ingestion. This study developed the simultaneous analysis method for 5 surfactants with LC-MS/MS for analysis of detergent residues after washing vegetables and fruits with detergent. The mobile phase used distilled water and acetonitrile containing 50 mM ammonium formate and 0.1% formic acid and was analyzed using a gradient method using XBridge BEH C8 column. The accuracy of the established method was 83.9-112.1%, and the precision was less than 20%. The detection limit was 7.0 (SLS) to 29.0 (SLES-N3) ㎍/L, and the correlation coefficient (r2) of calibration line regression was greater than 0.99, it is considered suitable for the analysis of trace amounts of surfactant components remaining in vegetables and fruits.