• Title/Summary/Keyword: Housing Performance

Search Result 875, Processing Time 0.028 seconds

Seismic Performance Evaluation of Reinforced Concrete Shear Wall Systems Designed with Special and Semi-Special Seismic Details (특수 및 준특수 상세에 따른 철근콘크리트 전단벽의 내진성능평가)

  • Oh, Hae Cheol;Lee, Kihak;Chun, Young Soo;Kim, Tae Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.181-191
    • /
    • 2014
  • This research presents the nonlinear analysis model for reinforced concrete shear wall systems with special boundary elements as proposed by the Korean Building Code (KBC, 2009). In order to verify the analysis model, analytical results were compared with the experimental results obtained from previous studies. Established analytical model was used to perform nonlinear static and dynamic analyses. Analytical results showed that the semi-special shear wall improved significantly the performance in terms of ductility and energy dissipation as expected based on previous test results. Furthermore, nonlinear incremental dynamic analysis was performed using 20 ground motions. Based on computer analytical results, the ordinary shear wall, special shear wall and newly proposed semi-special shear wall systems were evaluated based on the methods in FEMA P965. The results based on the probabilistic approaches accounting for inherent uncertainties showed that the semi-special shear wall systems provide a high capacity/demand (ACMR) ratio owing to their details, which provide enough capacity to sustain large inelastic deformations.

Seismic Performance of Special Reinforced Concrete Coupling Beams with Different Reinforcement Details (보강상세에 따른 특수전단벽 연결보의 내진성능)

  • Chun, Young-Soo;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.6 no.1
    • /
    • pp.21-29
    • /
    • 2015
  • Coupling beams posses proper strength, stiffness and ductility capacities to resist efficiently under seismic loads. The strength, stiffness and ductility capacities for special diagonally reinforced concrete coupling beam with a span-to-depth ratio 2.0 or less is higher than those of coupling beam with conventionally reinforced concrete coupling beam. However, diagonally reinforced detailing creates major construction problem. In this study, design alternatives for diagonally reinforced concrete coupling beams were experimentally investigated. The results show that angle reinforced coupling beam(specimen SA) exhibited a better stable behavior in comparison with non-diagonally coupling beams(specimens SB-series) and sustained corresponding drift ratio, peak-to-peak stiffness and cumulative dissipated energy in comparison to diagonally coupling beam(specimen CA).

A Study on the Establishment of an Evaluation System for Integrative Comfort Performance of Hanok Residence (한옥의 통합 쾌적성능 평가체계 구축에 관한 연구)

  • Han, Seung-Hoon;Cheon, Deuk-Youm;Lee, Mi-Hyang;Im, Ok-Kyun
    • Journal of the Korean housing association
    • /
    • v.24 no.3
    • /
    • pp.27-35
    • /
    • 2013
  • The purpose of this study is to develop an evaluation system for integrative comfort values of Hanok residence. For this study, a mock-up located in Yongin, Gyeonggi province built by an ongoing governmental research project has been chosen. Then, SSN (Smart Sensor Network) has been utilized for monitoring quantitative factors in the environment and detailed face-to-face surveys have been performed for analyzing qualitative comfort indexes from residents in the experimental settings. Then, this study employs a combined evaluation system using AHP (Analytic Hierarchy Process) established for estimating overall DIC (Degree of Integrative Comfort) of the Hanok residence. As a result, the evaluation system could verify the total comfort indexes of Hanok residence and suggest converged methodologies for establishing value assessment system for traditional residential facilities. The method of DIC suggested in this paper would be examined with current residents in a built mock-up to see its applicability as a comprehensive evaluation model, and it is expected that collected year-round comfort data from the facility would provide more practical information towards future strategies for the Hanok residence.

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

Seismic Retrofit Method for Piloti Buildings According to Type of Core (코어의 유형에 따른 필로티형 건축물의 내진보강방안)

  • Kim, Minjun
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.83-102
    • /
    • 2022
  • After the earthquake in South Korea (Gyeongju and Pohang), interest in securing the seismic performance of piloti buildings was increasing. In this paper, a study was conducted to propose a seismic retrofit method for piloti building of LH. The proposed seismic retrofit method considers the priority of seismic retrofit and the type of core. To verify the effectiveness of the proposed seismic retrofit method, computational analysis was performed according to the type of core. As a result, it was confirmed that the seismic performance was improved when the proposed seismic retrofit method was used.

Estimation of Dynamic Parameters and Concrete Strength of a Structural Member by Impact Hammer Testing (임팩트해머 실험에 의한 부재의 동적파라미터 및 콘크리트 강도 추정)

  • Sehee Kim;Junghyun Kyung;Heechang Eun
    • Land and Housing Review
    • /
    • v.15 no.3
    • /
    • pp.153-164
    • /
    • 2024
  • Structural health monitoring involves performance evaluation based on measurements for maintenance purposes. By back-calculating measured Frequency Response Function (FRF) data, the concept of effective mass was introduced and applied to the performance evaluation of structural members. An identification method was proposed that uses participation factors to estimate the dynamic parameters and the strength of concrete of structural members. The appropriateness of these methods for identifying dynamic parameters and concrete strength of structural members was validated through experimental results, proving their utility in non-destructive testing for concrete strength.

Changes in Demographic and Housing Characteristics of New Towns in Korea: Focused on Five New Towns in Seoul Metropolitan Area (우리나라 신도시의 인구 및 주거특성 변화: 분당, 일산 등 1기 신도시를 중심으로)

  • Yoon, Jeong-Joong;Kim, Eun-Mi
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.235-246
    • /
    • 2014
  • In the late 1980s, 5 new towns such as Bundang, Ilsan, Pyeongchon, Sanborn, Jungdong were constructed to solve housing problems and to disperse functions concentrated within Seoul. As the city got matured, it began to appear the initial signs of urban problems such as aging of high rise-density apartment sites, traffic congestion, lack of parking spaces and aging of infrastructure. Therefore, in order to cope with urban problems, it is very important to apprehend the process of urban growth, its change and the feature of physical/human elements. So, the purpose of this thesis is to analyze the changes in housing and population characteristics for past 20 years by use of Census data from 1995 to 2010. First, the new town's goal of population and housing plan at the time of construction was analyzed how it was achieved, and it is close to the performance of the goal. And the trend of changes in the population and household characteristics was analyzed by every five year's data. As the result of analysis, it shows socio-demographic changes such as aged and elderly population growth, rapid increase in one generation's household and single person household, highly educated city, monthly rent household's increase and charter household's reduction. Results of this analysis can be utilized to aforethought management of new towns. But it is required more sustained and systematic urban monitoring and data analysis because the one-off analysis of the city's characteristics alone is difficult enough to grasp them.

Three-dimensional Equivalent Transient Ground Heat Exchanger Thermal Analysis Model by Considering Heating and Cooling Operations in Buildings (건물의 냉난방 운전을 고려한 3차원 동적 지중 열교환기 열해석 모델)

  • Baek, Seung Hyo
    • Land and Housing Review
    • /
    • v.9 no.4
    • /
    • pp.25-32
    • /
    • 2018
  • Application of geothermal energy in buildings has been gaining popularity as it provides the benefits of both heating and cooling a building. Among the various types of geothermal energy systems, ground-coupled heat pump system is the most commonly applied one in South Korea. A ground heat exchanger plays an important role as a heat source in winter and a heat sink in summer. For the stable operation of a ground-coupled heat pump system, a ground heat exchanger should be sized so that it provides sufficient heating and cooling energy. Heating and cooling energies generated in ground heat exchangers mainly depend on the temperature difference between the heating medium in ground heat exchangers and the surrounding ground. In addition, the performance of ground heat exchangers influences the change in ground temperature. Therefore, it is necessary to consider this interrelation between the change in the ground temperature and the performance of ground heat exchanger for an accurate estimation of its performance. However, previous thermal analysis models for ground heat exchangers are not competent enough to allow a complete understanding of this interrelation. Therefore, this study proposes a three-dimensional equivalent, transient ground heat exchanger analysis model. First, a previous thermal analysis model for ground heat exchangers, including an analytical model, a g-function, and a numerical model are analyzed. Next, to overcome the limitations of the previous models, a three-dimensional equivalent, transient ground heat exchanger model is proposed. Finally, this study validated the proposed model with the measurement data of the thermal response test, sandbox test, and TRNSYS DST model. All validation results showed a good agreement. These findings helped us to investigate the thermal performance of ground heat exchangers more accurately than the analytical models, and faster than the numerical models. Furthermore, the proposed model contributes to the design of ground heat exchangers by considering the different operation conditions of buildings.

Establishing a Energy Utilization Database for Energy Performance Evaluation of Multi-Family Housing using District Heating (지역난방 공동주택의 에너지 성능 평가를 위한 공동주택 단지별 에너지사용량 Database 구축)

  • Jeong, Jaewook;Hong, Taehoon;Ji, Changyoon;Leigh, Seung-Bok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.5
    • /
    • pp.105-113
    • /
    • 2015
  • In order to evaluate the energy performance of buildings, it is important to determine reliable information of energy utilization during operating phase. It is also required to establish the database which have the amounts of population deducted by objective filtering and analysis. In this study, all energy sources were applied to evaluate synthetically the energy performance of Multi-Family Housings(MFH) using district heating and the amounts of population were obtained sufficiently through data searching in Seoul and neighbor cities. Finally the database of source energy utilization and $CO_2$ emission in 325 MFH complexes were established through cross validation between data sources and statistical analysis. Additionally, further ideas have been proposed to improve existing MFH Management Information System.

The Strengthening Effect of the Heating and Cooling Load on the Thermal Performance in the Housing Unit (주택에서의 단열성능 강화가 냉난방부하에 미치는 영향)

  • Lee, Jun-Gi;Kim, Sung-Hoon;Lee, Gab-Taek;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.483-488
    • /
    • 2016
  • In this study, we chose the rural house as a standard model. In order to review the energy difference of cooling and heating loads, we changed the thermal transmittance standards. By using the thermal transmittance standard in 2011 as the Basic CASE, the thermal transmittance standard in 2013 as well as 2016, and the thermal transmittance standard of passive houses, we compared the results with regard to the cooling and heating energy load. Because of the heat loss, it can be confirmed that with an improved thermal performance of the building structure, the maximum increase of the cooling energy load was 36 kWh from June to September. Because of the heat loss, it was also confirmed that with the improved thermal performance of a building structure, the maximum decrease of the heating energy load is 1,498 kWh from November to April. Even though the heat loss of the building structure could decrease the cooling energy load by improving thermal transmittance standards in Korea, the energy saving performance is worse than the situation of heating energy load in heating period. Compared with CASE 1 and CASE 2, as well as CASE 1 and CASE 3, we CASE 3 was found to have the best energy saving rate when compared to the other cases : CASE 3 increased by 1,452 kWh and CASE 2 by 588 kWh, because the window thermal transmittance standard of 2016 was added.