• Title/Summary/Keyword: Housing Performance

Search Result 875, Processing Time 0.032 seconds

A Pilot Project on the Integrated System Design for Developing the Sustainable Housing Model (친환경 공동주택 구현을 위한 저에너지 설비시스템 통합설계 방안 및 파일럿 프로젝트 계획)

  • Cho, Jin-Kyun;Sung, Jae-Ho;Shin, Seon-Joon;Hong, Min-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1049-1054
    • /
    • 2009
  • Sustainable housing design can contribute to dramatically reduced energy usage and can be applied to all new building projects. This paper explores the potential in Korea of applying available energy efficient building technologies. The objective was to determine the degree of energy reduction that can easily be achieved in new building design. The pilot project is providing some prototypes with display units which incorporate principles of sustainable design and performance utilizing the eco-design objectives. This building challenges ingrained preconceptions about system designs for four energy saving levels(40%, 60%, 80% and zero energy) and exposes barriers to low energy buildings posed by new standards and guidelines.

  • PDF

Construction and Characterization of the Stainless Steel Isolated Type Semiconductor Pressure Sensor (스테인레스 봉입형 반도체 압력센서의 제작 및 그 특성)

  • Kim, Woo-Jeong;Cho, Yong-Soo;Hwang, Jung-Hoon;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.138-144
    • /
    • 2002
  • The silicon piezoresistive pressure sensor is made by semiconductor process to obtain stainless steel isolated type pressure sensor. The sensor is loaded on a stainless steel housing with glass molding, $50\;{\mu}m$ stainless steel thin film is welded, and the stainless steel housing encapsulated by silicone oil. The performance of fabricated the pressure sensor has 10 bar pressure range. The XTR105 of exclusive transmitter chip is used the pressure transmitter that output current is 4 - 20 mA. The accuracy is ${\pm}5%$ FS, however, the accuracy is ${\pm}1%$ FS when the sensor is compensated temperature.

A Study on the Performance Experiments of Lightweight Wall of Long-life Housing by Ceiling Infill System (천장 인필시스템에 따른 장수명주택 경량벽체의 성능실험에 관한 연구)

  • Seo, Dong-Goo;Lee, Jong-Ho;Kim, Eun-Young;Hwang, Eun-Kyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.247-248
    • /
    • 2018
  • In order to secure the variability of long-life housing, dry walls are used. The composite gypsum board panel is the most frequently used infill system for the wall, and it is an excellent construction method in terms of constructability and economic feasibility. However, there are also problems such as the destruction of Ondol pipes at the bottom floor and being unable to fix the light weight steel frame (M-bar) when a variable composite gypsum board panel is used. To solve such problems, a wall with a method of fixing only the top part without fixing the bottom floor is developed, but it is difficult to identify the durability of ceiling frame according to the tensile force of stud and the safety according to the Stiffness and impact resistance (soft body) of ceiling frame. Therefore, this study verified the effectiveness of infill system for the wall by conducting experiment on the stiffness and impact resistance of composite gypsum board panel according to the reinforcement of ceiling frame (wooden frame, double saw-toothed bracket, Cross M-bar). As a result, it was possible to secure the safety of wooden frame while the impact resistance and the Stiffness of double saw-toothed bracket and cross M-bar were not secured.

  • PDF

A study on the elimination of static electricity by use of beta radiation source (Beta 방사선원을 이용한 정전기 제거법에 대한 고찰)

  • 임용규
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.28-33
    • /
    • 1965
  • This experiment is based on "the feasible improvement studies for an eliminating device of the static electricity which applies the ionizing effect of beta radiation." In order to accomplish this object, the following problems were necessarily considered to investigate and to determine. The efficiency of the elimination of static electricity was determined by means of measuring the ion current between electrically charged plates with micro-ammeter. The effects of various factors, i.e., the distance between charged plate and radiation source, the activity of radiation source, the electric otential and the area of the charged plate, the shape of the source housing, the lining of backscattering material (Pb) on the source housing surface and blowing of ionized air, on the static electricity eliminating efficiency were studied. The beta radiation sources used in this experiment were S$^{35}$ and Sr$^{90}$ -Y$^{90}$ . It was revealed that ion current increased with source activity, the electric potential and area of the plates, the lead (Pb) lining on the surface of the source housing and the velocity of the ionized air blowing. As one could expect the S$^{35}$ was more effective to increase the ion current since it is known to be a higher specific ionization source than Sr$^{90}$ -Y$^{90}$ . The detailed result and performance of the eliminating device of the static electricity are described here.ibed here.

  • PDF

An Experimental Study on the Load Resistance of Toilet Bowl in Long-Life Housing Infill System (장수명주택 벽배관 시스템의 양변기 하중저항성에 대한 실험적 연구)

  • Lee, Jongho;Seo, Dong-Gu;Kim, Eun-Young;Hwang, Eun-Kyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.211-212
    • /
    • 2019
  • It is possible to realize the concept of long-life housing by utilizing the wall piping infill system. However, when using the wall piping infill system, there is no detailed standard in Korea. Problems may occur in actual use. In this study, we use the results obtained from the performance test method as a basic data. Since the load resistance test of the toilet is not available in Korea, GB 6952 (Sanitary wares) of China is applied. According to the experiment of load resistance of the toilet in this study, the strain recovery ability was good. However, it is not possible to exclude the possibility of permanent deformation of the toilet seat due to long - term repeated loading. Therefore, it is necessary to consider the stiffness enhancement of the wall (steel frame) to the fixing part when installing the toilet in the wall pipe infill system.

  • PDF

Study on the Application of Modular Technologies to Han-ok (한옥의 모듈러 공법 적용에 관한 연구)

  • Lee, Chang-Jae;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.23 no.4
    • /
    • pp.49-57
    • /
    • 2012
  • This study was conducted to apply the modular construction method to Han-ok. The modular method, which is differentiated from the existing one, means a construction method that equipments, windows and interior materials are prefabricated as a six-sided object at a plant and then they are assembled at the least process on the spot. As for the theoretical observation, the theoretical basis to apply the modular method to the modular housing and Hanok was divided into environmental and economic aspect. In order to apply the modular method to Hanok, the unit scale and size were selected and the plane of unit module Hanok was developed. And a standard with regard to the unit combination and material lifting transportation method was set and planned. In addition, through the comparison the unit modular Hanok to the existing Hanok, the difference was analyzed and the strength was identified in terms fo design method, structure, construction method, period and cost. In final, the conclusion, with regard to the economic, technical application in future, was drawn through arranging the study contents. The unit modular Hanok to carry out the high-quality dwelling through construction period reduction, standardized construction materials and improved insulation performance can meet the demands for a paradigm of new construction technology.

Analyzing the air tightness of public housing through a blower door test (Blower door test를 통한 공공행복주택의 침기율 분석)

  • Kim, Jae-Hee;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.167-168
    • /
    • 2023
  • The government has established a zero-energy roadmap in accordance with its 2050 carbon neutrality strategy, and from 2023 onwards, residential buildings with 30 generations or more must be constructed as zero-energy structures. In response to this, measures for energy conservation through enhanced building tightness are being developed. The LH (Land and Housing Corporation) aims to achieve the first-stage building tightness performance targets by 2022 in preparation for this. Currently, South Korea has the "KS L ISO9972 - Building Tightness - Measuring the airtightness of buildings by the fan pressurization method" as the method for measuring building tightness, which was established in 2006 and revised in 2016. In practice, the airtightness is measured using the Blower Door Test method, and it is expressed as ACH50 (the number of air changes per hour at a pressure difference of 50 Pa between the indoor and outdoor environments). This study aims to measure and analyze the airtightness of Happy Homes constructed from 2020 to 2022, categorized by building type.

  • PDF

Energy Performance Evaluation of a New Commercial Building using Calibrated As-built Simulation with Monitoring Data (건물에너지 모니터링 및 시뮬레이션을 활용한 신축건물의 에너지성능평가)

  • Song, Su-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.155-166
    • /
    • 2008
  • The performance evaluation of a new building is becoming more important because efficient design alone is often not sufficient to deliver an efficient building. However, there is a lack of standard evaluation methods to measure the energy performance of a new construction that has Energy Conservation Design Measures(ECDMs). This study presents an enhanced method based on calibrated whole-building simulation for evaluating the energy performance of new commercial buildings and demonstrates its use using a case-study building, including: an Energy Use Index(EUI) comparison with sub-metered data and an evaluation of the performance of specific ECDMs. The use of this method has determined that the case-study building was shown to use approximately 47% less energy than the base-case building that has the same shape and function as the case-study building(i.e., calibrated as-built simulation mode]), but doesn't include the simulated ECDMs.

A Study on the Insulation Performance of Impact Sound Level by Striking Location of Floor Slab (바닥 슬라브의 가진 위치에 따른 차음성능에 관한 연구)

  • Song, Pil-Dong;Park, Myung-Kil;Ham, Jin-Sik
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.73-76
    • /
    • 2003
  • This paper is contents about method to measure interception performance of shock noise of floor slab of apartment house to be simple. In the case of interception performance of light floor impact sound level, according to measurement method, grade of sound insulation performance showed greatly differently. But, in the case of interception performance of heavy floor impact sound level, it was similar result in all measurement method. Therefore, use of simple method of measurement was examined by possible fact in case of interception performance of heavy floor impact sound level.

  • PDF

Comparison of the forecasting models with real estate price index (주택가격지수 모형의 비교연구)

  • Lim, Seong Sik
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.6
    • /
    • pp.1573-1583
    • /
    • 2016
  • It is necessary to check mutual correlations between related variables because housing prices are influenced by a lot of variables of the economy both internally and externally. In this paper, employing the Granger causality test, we have validated interrelated relationship between the variables. In addition, there is cointegration associations in the results of the cointegration test between the variables. Therefore, an analysis using a vector error correction model including an error correction term has been attempted. As a result of the empirical comparative analysis of the forecasting performance with ARIMA and VAR models, it is confirmed that the forecasting performance by vector error correction model is superior to those of the former two models.