• Title/Summary/Keyword: Hounsfield

Search Result 164, Processing Time 0.028 seconds

The Objective Image Analysis for HCC and HH with a Axial Image of Liver CT Scan (Liver CT 단면영상에서 간세포암과 간혈관종의 객관적 영상분석)

  • Hwang, In-Gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.411-417
    • /
    • 2015
  • To distinguish between HCC and HH is one of the important test methods in determining the treatment method by determining the treatment method by distinguishing malignant growth and benign tumors in liver CT scan. Currently, the specialist is reading CT images by their subjective judgment. So, the purpose of this study is to treat reading the CT images even more objective way. The test times after injection contrast medium in this study are the before injection phase(Pre.), artery phase(35sec), portal phase(70sec) and delay phase(180sec). The general pattern change of HCC in change of contrast enhancement pattern shows 26.6% matching. And the case of HH shows 16.6% matching. In order to observe the change of HU value between HCC and HH, each average values and standard deviation was confirm and as a result, it shows the lagre difference between artery and portal phase in lesion.(HCC$19.76{\pm}23.52$, HH$60.23{\pm}29.43$). And it shows the 76.6% matching in HCC and 80.0% matching in HH. Thorough this study, to suggest a HU value as objective analysis method and if the anlaysis method was used in clinical will assist in the diagnosis.

Delayed Burr Hole Surgery in Patients with Acute Subdural Hematoma : Clinical Analysis

  • Choi, Yoon Heuck;Han, Seong Rok;Lee, Chang Hyun;Choi, Chan Young;Sohn, Moon Jun;Lee, Chae Heuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.717-722
    • /
    • 2017
  • Objective : To evaluate the effectiveness and efficacy of delayed burr hole surgery in relation to the reduction of postoperative subdural hematoma (SDH) volume in patients with acute SDH. Methods : We retrospectively analyzed patients with acute SDH who received delayed burr hole surgery at our institute. Age, sex, Glasgow coma scale, maximal SDH thickness, volume of SDH, midline shifts, hounsfield unit (HU), and medical history of anticoagulant agent usage were recorded. Outcome measures were delayed operation day, reduction of SDH volume after operation, and the Glasgow outcome scale (GOS) score at discharge. The patients were divided two groups according to the postoperative reduction of volume of SDH (${\geq}50%$, group A; <50%, group B). We also analyzed variables and differences between two groups. Results : Eighteen patients were available for this analysis. The mean delayed of surgery was $13.9{\pm}7.5$ days. Maximal thickness of SDH was changed from $10.0{\pm}3.5mm$ to $12.2{\pm}3.7mm$. Volume of SDH was changed from $38.7{\pm}28.0mL$ to $42.6{\pm}29.6mL$. Midline shifts were changed from $5.8{\pm}3.3mm$ to $6.6{\pm}3.3mm$. HU were changed from $66.4{\pm}11.2$ to $53.2{\pm}20.6$. Post-operative reduction of SDH volume was $52.1{\pm}21.1%$. Eleven patients (61%) had a discharge GOS score of 1 (good recovery). Ten patients (56%) were enrolled in group A. Midline shifting was greater in group A than in group B ($7.4{\pm}3.3$ vs. $3.0{\pm}2.4mm$; p<0.02). The delay of surgery was shorter for group A than group B ($9.2{\pm}2.3$ vs. $19.8{\pm}7.7$ days; p<0.0008). Conclusion : Among well selected patients, delayed burr hole surgery in patients with acute SDH may be effective for reduction of SDH volume. Further studies will be necessary to establish the effectiveness and safety of delayed burr hole surgery in patients with acute SDH.

Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image (CT 영상을 이용한 불균질 조직의 선량보정 평가)

  • Kim, Gha-Jung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: In radiation therapy, precise calculation of dose toward malignant tumors or normal tissue would be a critical factor in determining whether the treatment would be successful. The Radiation Treatment Planning (RTP) system is one of most effective methods to make it effective to the correction of dose due to CT number through converting linear attenuation coefficient to density of the inhomogeneous tissue by means of CT based reconstruction. Materials and Methods: In this study, we carried out the measurement of CT number and calculation of mass density by using RTP system and the homemade inhomogeneous tissue Phantom and the values were obtained with reference to water. Moreover, we intended to investigate the effectiveness and accuracy for the correction of inhomogeneous tissue by the CT number through comparing the measured dose (nC) and calculated dose (Percentage Depth Dose, PDD) used CT image during radiation exposure with RTP. Results: The difference in mass density between the calculated tissue equivalent material and the true value was ranged from $0.005g/cm^3\;to\;0.069g/cm^3$. A relative error between PDD of RTP and calculated dose obtained by radiation therapy of machine ranged from -2.8 to +1.06%(effective range within 3%). Conclusion: In conclusion, we confirmed the effectiveness of correction for the inhomogeneous tissues through CT images. These results would be one of good information on the basic outline of Quality Assurance (QA) in RTP system.

  • PDF

Effect of Silver Diamine Fluoride and Sodium Fluoride Varnish on Remineralization in Artificially Induced Enamel Caries: An in vitro Study (Silver diamine fluoride와 sodium fluoride (NaF) 바니쉬의 법랑질 인공우식병소 재광화 효과)

  • Kim, Soyoung;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.266-276
    • /
    • 2020
  • The purpose of this study was to compare the remineralization effect of 38% silver diamine fluoride (SDF) and 5% sodium fluoride (NaF) varnish on artificially induced enamel caries. The present study standardized the physiochemical characteristics of the tooth structure using bovine teeth, realized the wash-off action of agents using a saliva, reproduced an environment similar to mouth through pH-cycling, and comparatively assessed the remineralization effect of 38% SDF and 5% NaF varnish in a non-destructive method using micro-CT. And the remineralized enamel surface structure was analyzed by scanning electron microscopy (SEM) and energy dispersive X-Ray spectroscopy (EDS). In both SDF and NaF varnish, mineral density (△Hounsfield unit value) and the volume of enamel restored to normal mineral density through remineralization gradually increased with time. And the SDF showed a much higher level of increase in mineral density at all depths and remineralized volume than NaF varnish. According to SEM analysis, the surface roughness decreased in the order of artificial saliva, NaF varnish and SDF. In addition, EDS analysis showed that silver ion was precipitated on the enamel surface in SDF group. In conclusion, SDF had a greater remineralization effect than NaF varnish on demineralized enamel.

Anatomical and Functional Recovery of Neurotized Remnant Rectus Abdominis Muscle in Muscle-Sparing Pedicled Transverse Rectus Abdominis Musculocutaneous Flap

  • Jeong, Woonhyeok;Son, Daegu;Yeo, Hyeonjung;Jeong, Hoijoon;Kim, Junhyung;Han, Kihwan;Lee, Soyoung
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.359-366
    • /
    • 2013
  • Background Pedicled transverse rectus abdominis musculocutaneous flaps typically sacrifice the entire muscle. In our experience, the lateral strip of the rectus abdominis muscle can be spared in an attempt to maintain function and reduce morbidity. When the intercostal nerves are injured, muscle atrophy appears with time. The severed intercostal nerve was reinserted into the remnant lateral strip of the rectus abdominis muscle to reduce muscle atrophy. Methods The authors retrospectively reviewed 9 neurotized cases and 10 non-neurotized cases. Abdominal computed tomography was performed to determine the area of the rectus muscles. Electromyography (EMG) was performed to check contractile function of the remnant muscle. A single investigator measured the mean areas of randomly selected locations (second lumbar spine) using ImageJ software in a series of 10 cross-sectional slices. We compared the Hounsfield unit (HU) pre- and postoperatively to evaluate regeneration quality. Results In the neurotization group, 7 of 9 cases maintained the mass of remnant muscle. However, in the non-neurotization group, 8 of 10 lost their mass. The number of totally atrophied muscles in each of the two groups was significantly different (P=0.027). All of the remnant muscles showed contractile function on EMG. The 9 remaining remnant rectus abdominis muscles showed declined the HU value after surgery but also within a normal range of muscle. Conclusions Neurotization was found to be effective in maintaining the mass of remnant muscle. Neurotized remnant muscle had contractile function on EMG and no fatty degeneration by HU value.

Comparison of SUV for PET/MRI and PET/CT (인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화)

  • Kim, Jae Il;Jeon, Jae Hwan;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.10-14
    • /
    • 2013
  • Purpose: Due to developed simultaneous PET/MRI, it has become possible to obtain more anatomical image information better than conventional PET/CT. By the way, in the PET/CT, the linear absorption coefficient is measured by X-ray directly. However in case of PET/MRI, the value is not measured from MRI images directly, but is calculated by dividing as 4 segmentation ${\mu}-map$. Therefore, in this paper, we will evaluate the SUV's difference of attenuation correction PET images from PET/MRI and PET/CT. Materials and Methods: Biograph mCT40 (Siemens, Germany), Biograph mMR were used as a PET/CT, PET/MRI scanner. For a phantom study, we used a solid type $^{68}Ge$ source, and a liquid type $^{18}F$ uniformity phantom. By using VIBE-DIXON sequence of PET/MRI, human anatomical structure was divided into air-lung-fat-soft tissue for attenuation correction coefficient. In case of PET/CT, the hounsfield unit of CT was used. By setting the ROI at five places of each PET phantom images that is corrected attenuation, the maximum SUV was measured, evaluated %diff about PET/CT vs. PET/MRI. In clinical study, the 18 patients who underwent simultaneous PET/CT and PET/MRI was selected and set the ROI at background, lung, liver, brain, muscle, fat, bone from the each attenuation correction PET images, and then evaluated, compared by measuring the maximum SUV. Results: For solid $^{68}Ge$ source, SUV from PET/MRI is measured lower 88.55% compared to PET/CT. In case of liquid $^{18}F$ uniform phantom, SUV of PET/MRI as compared to PET/CT is measured low 70.17%. If the clinical study, the background SUV of PET/MRI is same with PET/CT's and the one of lung was higher 2.51%. However, it is measured lower about 32.50, 40.35, 23.92, 13.92, 5.00% at liver, brain, muscle, fat, femoral head. Conclusion: In the case of a CT image, because there is a linear relationship between 511 keV ${\gamma}-ray$ and linear absorption coefficient of X-ray, it is possible to correct directly the attenuation of 511 keV ${\gamma}-ray$ by creating a ${\mu}$map from the CT image. However, in the case of the MRI, because the MRI signal has no relationship at all with linear absorption coefficient of ${\gamma}-ray$, the anatomical structure of the human body is divided into four segmentations to correct the attenuation of ${\gamma}-rays$. Even a number of protons in a bone is too low to make MRI signal and to localize segmentation of ${\mu}-map$. Therefore, to develope a proper sequence for measuring more accurate attenuation coefficient is indeed necessary in the future PET/MRI.

  • PDF

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT에서의 간암-간 대조 곡선의 Simulation)

  • S.J. Kim;K.H. Lee;J.H. Kim;J.K. Han;B.G. Min
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.173-182
    • /
    • 1999
  • Contrast-enhanced CT has an important role in assessing liver lesions, the optimal protocol to get most effective result is not clear. The mein goal when deciding injention protocol is to optimize lesion detectability with rapid scanning when lesion to liver contrast is maximum. For this purpose, we developed a physiological model of the contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver is achieved in two paths. This dual supply characteristic distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and to second, by portal vein. However, it is assumed that only gepatic artery can supply blood to hepatocellular carcinoma(HCC) compartment, thus, the difference of contrast enhancement is resulted between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using the computer program Matlab, CT contrast-enhancement curves were simulated. The simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with the mean enhancement curves from 24 patients exposed to the same protocols as the simulation. These enhancement curves showed a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and the effects were analyzed. The variables to be considered in the injection protocol were injection rate, dose, and concentration of contrast material. These data may help to optimize scanning protocols for better diagnosis.

  • PDF

Quantitative Analysis of Tooth Mineral Content by High Resolution Micro-computed Tomography

  • Song, Dae-Sung;Kim, Jung-Woo;Hwang, Hee-Su;Oh, Sin-Hye;Song, Ju Han;Kim, Il-Shin;Hwang, Yun-Chan;Koh, Jeong-Tae
    • International Journal of Oral Biology
    • /
    • v.42 no.4
    • /
    • pp.155-161
    • /
    • 2017
  • Teeth and bones are highly mineralized tissues containing inorganic minerals such as calcium phosphate, and a growing number of evidences show that their mineral content is associated with many diseases. Although the quantification of mineral contents by micro-computed tomography(micro- CT) has been used in diagnosis and evaluation for treating bone diseases, its application for teeth diseases has not been well established. In this study, we attempted to estimate a usefulness of a high-resolution micro-CT in analysis of human teeth. The teeth were scanned by using the Skyscan 1172 micro-CT. In order to measure tooth mineral content, beam hardening effect of the machine was corrected with a radiopaque iodine-containing substance, iodoacetamide. Under the maximum resolution of $6.6{\mu}m$, X-ray densities in teeth and hydroxyapatite standards were obtained with Hounsfield unit (HU), and they were then converted to an absolute mineral concentration by a CT Analyzer software. In enamel layer of cusp area, the mean mineral concentration was about $2.14mg/mm^3$ and there was a constant mineral concentration gradient from the enamel surface to the dentinoenamel junction. In the dentin of middle 1/3 of tooth, the mean mineral concentration was approximately $1.27mg/mm^3$ and there was a constant mineral concentration gradient from the outer of root to the pulp side, ranging from 1.3 to $1.06mg/mm^3$. In decay region of dentin, the mineral content was gradually decreased from the intact inner side to the decayed surface. These results suggest that high-resolution micro-CT can be as a useful tool for non-invasive measurement of mineral concentration in teeth.

Does epithelioid angiomyolipoma have poorer prognosis, compared with classic angiomyolipoma?

  • Lee, Wonchul;Choi, Se Young;Lee, Chanwoo;Yoo, Sangjun;You, Dalsan;Jeong, In Gab;Song, Cheryn;Kim, Kun Suk;Hong, Bumsik;Hong, Jun Hyuk;Ahn, Hanjong;Kim, Choung-Soo
    • Investigative and Clinical Urology
    • /
    • v.59 no.6
    • /
    • pp.357-362
    • /
    • 2018
  • Purpose: Classic angiomyolipoma (AML) is common benign kidney tumor. However, some studies have claimed that epithelioid angiomyolipoma (EAML) has malignant potential. We compared the patient characteristics and prognosis of EAML and classic AML to demonstrate predicting factors and poorer prognosis of EAML. Materials and Methods: The medical records of 231 patients who were diagnosed with EAML (n=27, 11.7%) or classic AML (n=204, 88.3%), were reviewed. All patients underwent computed tomography (CT) scans before operation or needle biopsy. We assessed the age, sex, tumor size, body mass index, comorbidities, and Hounsfield unit (HU) according to each CT phase. We defined the unfavorable group as patients with recurrence, metastasis and death due to tumor progression. Logistic regression analysis was used to predict EAML. Results: EAML patients were younger (41.2 years vs. 49.1 years, p=0.001), predominantly male (55.6% vs. 28.4%, p=0.005), and had a larger tumor (7.5 cm vs. 4.2 cm, p<0.001). The median pre-contrast HU was not significantly different between EAML and classic AML ($29.9{\pm}23.7$ vs. $14.7{\pm}41.0$, p=0.071). In multivariable analysis, younger age (odds ratio [OR], 0.96; p=0.032), male sex (OR, 3.33; p=0.013), and tumor larger than 4 cm (OR, 3.8; p=0.009) were significant predictive factors. Five patients (18.5%) had unfavorable outcomes, two patients had lymph node metastasis, and three patients had lung metastasis. Conclusions: Patient and tumor characteristics can be helpful in determining the type of AML preoperatively. Younger age, male sex, and larger tumor mass may increase the possibility of diagnosing EAML. EAML has malignant potential and requires careful follow-up.

Development of an Algorithm for Predicting the Thermal Distribution by using CT Image and the Specific Absorption Rate

  • Hwang, Jinho;Kim, Aeran;Kim, Jina;Seol, Yunji;Oh, Taegeon;Shin, Jin-sol;Jang, Hong Seok;Kim, Yeon Sil;Choi, Byung Ock;Kang, Young-nam
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1584-1588
    • /
    • 2018
  • During hyperthermia therapy, cancer cells are heated to a temperature in the range of $40{\sim}45^{\circ}C$ for a defined time period to damage these cells while keeping healthy tissues at safe temperatures. Prior to hyperthermia therapy, the amount of heat energy transferred to the cancer cells must be predicted. Among various non-invasive methods, the thermal prediction method using the specific absorption rate (SAR) is the most widely used method. The existing methods predict the thermal distribution by using a single constant for the mass density in one organ through assignment. However, because the SAR and the bio heat equation (BHE) vary with the mass density, the mass density of each organ must be accurately considered. In this study, the mass density distribution was calculated using the relationship between the Hounsfield unit and the mass density of tissues in preceding research. The SAR distribution was found using a quasi-static approximation to Maxwell's equation and was used to calculate the potential distribution and the energy distributions for capacitive RF heating. The thermal distribution during exposure to RF waves was determined by solving the BHE with consideration given to the considering contributions of heat conduction and external heating. Compared with reference data for the mass density, our results was within 1%. When the reconstructed temperature distribution was compared to the measured temperature distribution, the difference was within 3%. In this study, the density distribution and the thermal distribution were reconstructed for the agar phantom. Based on these data, we developed an algorithm that could be applied to patients.