• Title/Summary/Keyword: Hot uptake

Search Result 93, Processing Time 0.025 seconds

In order to standarization of Kye-Ji Tang of ${\ulcorner}$Treatise on Febrile Diseases${\lrcorner}$ (계지탕(桂枝湯)의 기미(氣味) 표준화 연구(I))

  • Kim, In-Rak
    • Journal of The Association for Neo Medicine
    • /
    • v.2 no.2
    • /
    • pp.297-314
    • /
    • 1997
  • This study was conducted to standardize the 'Ki-Mi' of Kye-Ji Tang in the basis of ${\ulcorner}$Treatise on Febrile Diseases${\lrcorner}$ and the results were as follows 1. The medicinal plants used are processed with hot water right after picking. 2. One seung(升) of water equals to 10cc. 3. One yang(兩) equals to 6 grams. 4. Medicinal plants are shattered to the size of beans by the process called Boo-Jeor. 5. Kye-Ji Tang, which is composed with 5 medicinal plant(Cortex Cinnamomi : 18g; Radix Paeoniae : 18g; Radix Glycyrrhizae : 12g; Rhizoma Zingiberis : 18g; Fructus Ziziphi Jujubae : 18g), is prepared by adding 490cc water to above 5 medicinal plants and boiled to 210cc. After boiling, the residue is discarded and the extract is taken orally 3 times a day as one dosage of 70cc. It is recommended that 20 minitues after taking of Kye-Ji Tang, the additional uptake of rice porridge might enhance the pharmacological effect of Kye-Ji Tang.

  • PDF

Assessment of Lymph Node Metastasis of the Stomach Cancer by Tc 99m Phytate Lymphoscintigraphy ($Tc^{99m}$ phytate를 이용한 위암의 임파절 영상)

  • Yoo, Hyung-Sik;Lee, Jong-Tae;Park, Chang-Yun;Min, Jin-Sik;Kim, Choong-Bai
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.2
    • /
    • pp.51-55
    • /
    • 1985
  • Prospective study of lymph node imaging of twenty stomach cancer cases with dissected lymph nodes being injected into the submucosa layer of stomach under surgical field was done. Total dose of 5 mci in 5 cc of volume was injected along the multiple sites of the lesser and greater curvature of stomach and collected lymph nodes within 2 hour of surgical time were placed under gamma camera and lymph node imagings were obtained. Pathological invasion of tumor and correlation of cold defect or hot uptake was compared each other. Tumor invasion of nodes revealed cold defect area which was correlated well with the pathological specimen. Correlation rate was 84.6%. We are planning to extend these procedures and trying endoscopic injection of positive imgaing agents such as Ga-73-3 Ig 2 alpha in future.

  • PDF

A Case of Multiple Pulmonary Plasmacytomas after Complete Remission of Multiple Myeloma (다발성 골수종의 관해 후 발생한 다발성 폐 형질 세포종 1예)

  • Sung, Pil-Soo;Song, Joon-Ho;Park, Chong-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.2
    • /
    • pp.129-133
    • /
    • 2010
  • Extramedullary plasmacytoma (EMP) is a rare disorder that typically occurs in the upper airway. Although the condition rarely arises in the lungs, a few cases have been reported. Here, we report a case of pulmonary plasmacytoma in 66-year-old man, who had been treated with VAD (vincrestine, adriamycin, dexamethasone) chemotherapy for multiple myeloma. The patient had been declared clear of multiple myeloma after 4 cycles of chemotherapy. Three months later, the patient had multiple masses visible on computed tomography (CT) and on positron emission tomography-computed tomography (PET-CT) with hot uptake. Subsequent studies using CT-guided needle biopsy and immunohistochemical stain showed pulmonary plasmacytoma. Bone marrow biopsy, serum, and urine M protein tests were repeated, showing no evidence of multiple myeloma. Pulmonary plasmacytomas, as extramedullary plasmacytomas, were considered an isolated manifestation of multiple myeloma recurrence. We treated the patient with concurrent chemoradiotherapy and the pulmonary plasmacytomas regressed dramatically.

Effect of extraction conditions on radical scavenging and cholesterol metabolism regulating capacity of silkworm larvae

  • Kim, Soo Hyun;Jo, You-Young;Kweon, HaeYong;Lee, Ji Hae
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.43 no.2
    • /
    • pp.45-51
    • /
    • 2021
  • High blood cholesterol levels and oxidized cholesterol are risk factors for cardiovascular disease, which displays high annual incidence. Although studies on sericulture products, including pupae, silk protein, and blood lymph, as hypocholesterolemic substances have been reported, insufficient research in this field has been focused on silkworm larvae. Six larval extracts (Low temperature distilled water, LW; hot temperature distilled water, HW; and 30-100% ethanol, E30-E100) were prepared, and their effects on cholesterol metabolism were examined. LW most potently reduced the risk of cholesterol-related disorders. Polyphenols were highly represented in LW, corresponding with its increased antioxidant potency. The cholesterol biosynthesis enzyme, 3-hydroxy-3-methyl-glutaryl-coenzyme A reductase (HMGCR) was strongly inhibited by LW. Hepatocytes over-expressed LDL receptor (LDLR) after LW stimulation, promoting cholesterol elimination from plasma. LW also increased ATP binding cassette transporter 1 (ABCA1) gene expression, upregulating HDL biogenesis. In conclusion, LW exhibited strong antioxidant activity, suppressed cholesterol biosynthesis, improved LDL uptake from plasma, and upregulated HDL biosynthesis. In aggregate, these activities could reduce blood cholesterol levels and prevent cardiovascular disease.

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

Evaluation of Fibrovascular Ingrowth into the Hydroxyapatite Ocular Implant by $^{99m}Tc$-MDP Bone Scintigraphy (골신티그라피에 의한 Hydroxyapatite 안구삽입물로의 섬유혈관증식 평가)

  • Bom, Hee-Seung;Song, Ho-Chun;Kim, Ji-Yeul;Jeong, Sang-Ki;Park, Young-Kul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.256-260
    • /
    • 1993
  • Thirteen patients received a coralline hydroxyapatite sphere as a buried integrated ocular implant after enucleation surgery. The implant was modified by multiple drillings, 1 mm in diameter, to the center of the sphere to allow more rapid host tissue ingrowth. $^{99m}Tc$-MDP planar and tomographic bone scintigraphies were performed at various intervals after implantation (from 100 to 742 days after operation) to assess vascularization of the implant. All patients showed hot uptakes in the implants. These patients underwent a secondary drilling for the final motility peg application. The confirmation of vascular ingrowth was done by inspection of bleeding at the time of bleeding at the time of drilling from the center of the implant. Bleeding from the drilled implant was noted in all patients. In cnclusion, hot uptake in the implanted ocular hydroxyapatite implant accurately reflect vascular ingrowth into the implant.

  • PDF

Current Status and Perspectives in Varietal Improvement of Rice Cultivars for High-Quality and Value-Added Products (쌀 품질 고급화 및 고부가가치화를 위한 육종현황과 전망)

  • 최해춘
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47
    • /
    • pp.15-32
    • /
    • 2002
  • The endeavors enhancing the grain quality of high-yielding japonica rice were steadily continued during 1980s-1990s along with the self-sufficiency of rice production and the increasing demands of high-quality rices. During this time, considerably great progress and success was obtained in development of high-quality japonica cultivars and quality evaluation techniques including the elucidation of interrelationship between the physicochemical properties of rice grain and the physical or palatability components of cooked rice. In 1990s, some high-quality japonica rice cultivars and special rices adaptable for food processing such as large kernel, chalky endosperm, aromatic and colored rices were developed and its objective preference and utility was also examined by a palatability meter, rapid-visco analyzer and texture analyzer, Recently, new special rices such as extremely low-amylose dull or opaque non-glutinous endosperm mutants were developed. Also, a high-lysine rice variety was developed for higher nutritional utility. The water uptake rate and the maximum water absorption ratio showed significantly negative correlations with the K/Mg ratio and alkali digestion value(ADV) of milled rice. The rice materials showing the higher amount of hot water absorption exhibited the larger volume expansion of cooked rice. The harder rices with lower moisture content revealed the higher rate of water uptake at twenty minutes after soaking and the higher ratio of maximum water uptake under the room temperature condition. These water uptake characteristics were not associated with the protein and amylose contents of milled rice and the palatability of cooked rice. The water/rice ratio (in w/w basis) for optimum cooking was averaged to 1.52 in dry milled rices (12% wet basis) with varietal range from 1.45 to 1.61 and the expansion ratio of milled rice after proper boiling was average to 2.63(in v/v basis). The major physicochemical components of rice grain associated with the palatability of cooked rice were examined using japonica rice materials showing narrow varietal variation in grain size and shape, alkali digestibility, gel consistency, amylose and protein contents, but considerable difference in appearance and texture of cooked rice. The glossiness or gross palatability score of cooked rice were closely associated with the peak, hot paste and consistency viscosities of viscosities with year difference. The high-quality rice variety "IIpumbyeo" showed less portion of amylose on the outer layer of milled rice grain and less and slower change in iodine blue value of extracted paste during twenty minutes of boiling. This highly palatable rice also exhibited very fine net structure in outer layer and fine-spongy and well-swollen shape of gelatinized starch granules in inner layer and core of cooked rice kernel compared with the poor palatable rice through image of scanning electronic microscope. Gross sensory score of cooked rice could be estimated by multiple linear regression formula, deduced from relationship between rice quality components mentioned above and eating quality of cooked rice, with high probability of determination. The $\alpha$-amylose-iodine method was adopted for checking the varietal difference in retrogradation of cooked rice. The rice cultivars revealing the relatively slow retrogradation in aged cooked rice were IIpumbyeo, Chucheongyeo, Sasanishiki, Jinbubyeo and Koshihikari. A Tonsil-type rice, Taebaegbyeo, and a japonica cultivar, Seomjinbyeo, showed the relatively fast deterioration of cooked rice. Generally, the better rice cultivars in eating quality of cooked rice showed less retrogradation and much sponginess in cooled cooked rice. Also, the rice varieties exhibiting less retrogradation in cooled cooked rice revealed higher hot viscosity and lower cool viscosity of rice flour in amylogram. The sponginess of cooled cooked rice was closely associated with magnesium content and volume expansion of cooked rice. The hardness-changed ratio of cooked rice by cooling was negatively correlated with solids amount extracted during boiling and volume expansion of cooked rice. The major physicochemical properties of rice grain closely related to the palatability of cooked rice may be directly or indirectly associated with the retrogradation characteristics of cooked rice. The softer gel consistency and lower amylose content in milled rice revealed the higher ratio of popped rice and larger bulk density of popping. The stronger hardness of rice grain showed relatively higher ratio of popping and the more chalky or less translucent rice exhibited the lower ratio of intact popped brown rice. The potassium and magnesium contents of milled rice were negatively associated with gross score of noodle making mixed with wheat flour in half and the better rice for noodle making revealed relatively less amount of solid extraction during boiling. The more volume expansion of batters for making brown rice bread resulted the better loaf formation and more springiness in rice breed. The higher protein rices produced relatively the more moist white rice bread. The springiness of rice bread was also significantly correlated with high amylose content and hard gel consistency. The completely chalky and large grain rices showed better suitability far fermentation and brewing. The glutinous rice were classified into nine different varietal groups based on various physicochemical and structural characteristics of endosperm. There was some close associations among these grain properties and large varietal difference in suitability to various traditional food processing. Our breeding efforts on improvement of rice quality for high palatability and processing utility or value-adding products in the future should focus on not only continuous enhancement of marketing and eating qualities but also the diversification in morphological, physicochemical and nutritional characteristics of rice grain suitable for processing various value-added rice foods.ice foods.

The synovial chondromatosis of the temporomandibular joints: review of the 4 cases (측두하악관절의 활액성 연골종증 4예)

  • Lee, Dong-Hyun;Shin, Jung-Sub;Kwak, Ju-Hee;Kim, Jin-Woo;Kim, Sun-Jong;Kim, Myung-Rae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.134-140
    • /
    • 2010
  • Synovial condromatosis of the temporomandibular joint (TMJ) is characterized by the presence of loose bodies (joint mices). It can be confused with temporomandibular disorder clinically, and be with chondrosarcoma histologically. The purpose of this clinical report was to review the clinical, radiological, arthroscopic findings, histological feature and the results of surgical treatment of TMJ synovial chondromatosis. Four patients presented with pain of TMJ and limited mouth opening. The dynamic magnetic resonance imaging (MRI) disclosed a characteristic morphologic changes and displacement of the meniscus with limited translation of the condyle head. Bone scans showed progressive resorptive changes with hot-uptake of the radioisotope. The synovial loose bodies in the joint spaces were removed and sent to pathology for diagnosis as the synovial chondromatosis. The follow-up examination with computed tomography (CT) and MRI revealed no evidence of recurrence and good in function until postoperative 18 months. Diagnostically, the distension of the lateral capsule and fluid findings in the joint on the MRI are very suggestive tool for this synovial chondromatosis, but they are not always detected on the preoperative MRI. Arthroscopic approaches are very useful to inspect the joint spaces and to remove the loose bodies without interruption of the whole synovial membranes.

Experience of Reconstruction of an Extensive Chest Wall Defect with Extended External Oblique Musculocutaneous Flap (거대 흉벽 결손에 대한 확장 외복사근 근피판을 이용한 흉벽재건 치험례)

  • Kim, Dae-Hee;Kim, Chung-Hun;Song, Seung-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.277-280
    • /
    • 2010
  • Purpose: The resection of locally advanced or recurred breast cancers frequently result in large chest wall defects and it leads to a great challenges to cover. Generally simple skin grafts are not a practical option for patients because of their poor cosmetic appearance and prognosis. The latissimus dorsi and rectus abdominis musculocutaneous flap have traditionally been recommended for closure of these large defects. Though the cosmetic result of reconstruction using these flaps is often excellent, but has significant drawbacks. Therefore, we thought that chest wall reconstruction using the external oblique musculocutaneous flap can be an alternative method for extensive chest wall defect related to large, locally advanced breast carcinoma. Methods & Results: We present a case of a 50-year-old Korean female, refered to our department with a left breast tumor for 10 months. CT demonstrate a large tumor on the left anterior chest wall and multiple nodules of varying size in the cervical areas and liver. FDG-PET showed areas of hot uptake throughout the left chest wall, mediastinum and liver. Biopsy was consistent with invasive ductal carcinoma (Grade III). The initial tumor was considered inoperable, so a series of chemotherapy was initiated. Though the size of the breast mass was slightly decreased, the patient continued to suffer from purulent discharge, unpleasant odor and contact bleeding of the mass, the salvage mastectomy was performed. Conclusion: We could reconstruct $23{\times}16\;cm$ sized large chest wall defect, resulting from the resection of a locally advanced breast carcinoma, using an external oblique musculocutaneous flap successfully. Immediate postoperatively checked flap was healthy. Overall result was good without any significant complications and discharged 3 weeks after operation.