• Title/Summary/Keyword: Hot plate test

Search Result 163, Processing Time 0.035 seconds

Thermal Design and Experimental Test of a High-Performance Hot Chuck for a Ultra Precision Flip-Chip Bonder (초정밀 플립칩 접합기용 고성능 가열기의 열적 설계 및 시험)

  • Lee Sang-Hyun;Park Sang-Hee;Ryu Do-Hyun;Han Chang-Soo;Kwak Ho-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.957-965
    • /
    • 2006
  • A high-performance hot chuck is designed as a heating device for an ultra-precision flip-chip bonder with infrared alignment system. Analysis of design requirements for thermal performance leads to a radiative heating mechanism employing two halogen lamps as heating source. The heating tool is made of silicon carbide characterized by high thermal diffusivity and small thermal expansion coefficient. Experimental tests are performed to assess heat-up performance and temperature uniformity of the heating tool. It is revealed that the initial design of hot chuck results in a good heat-up speed but there exist a couple of troubles associated with control and integrity of the device. As a means to resolve the raised issues, a revised version of heating tool is proposed, which consists of a working plate made of silicon carbide and a supporting structure made of stainless steel. The advantages of this two-body heating tool are discussed and the improved features are verified experimentally.

Infrared Temperature Monitoring System based CAN for USN (USN를 위한 CAN 기반 적외선 온도감시 시스템)

  • Kim, Young-Dong;Oh, Guem-Kon;Jeong, Won-Tae;Kang, Won-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.11-17
    • /
    • 2007
  • RWe have developed an infrared temperature monitoring system to measure the temperature of hot iron plate in very harsh environmental conditions as iron making equipment. We performed extensive field test for 3 months at the front side of iron plate rolling process of POSCO in Gwang-Yang. From the experimental test, we have confirmed the reliability of the developed system. We adjust the curve fit method to solve the non-linearity equations of A2TPMI sensor, and establish the under $1[^{\circ}C]$precision ratio and 25[msec] process speed each range. As experimental, we have confirmed the reliability of an infrared temperature monitoring system as POSCO test result and CAN network traffic monitoring of polling method.

Stress concentration factors test of reinforced concrete-filled tubular Y-joints under in-plane bending

  • Yang, Jun-fen;Yang, Chao;Su, Ming-zhou;Lian, Ming
    • Steel and Composite Structures
    • /
    • v.22 no.1
    • /
    • pp.203-216
    • /
    • 2016
  • To study the stress concentration factors (SCFs) of concrete-filled tubular Y-joints subject to in-plane bending, experiments were used to investigate the hot spot stress distribution along the intersection between chord and brace. Three concrete-filled tubular chords forming Y-joints were tested with different reinforcing components, including doubler-plate, sleeve, and haunch-plate reinforcement. In addition, an unreinforced joint was also tested for comparison. Test results indicate that the three different forms of reinforcement effectively reduce the peak SCFs compared with the unreinforced joint. The current research suggests that the linear extrapolation method can be used for chords, whereas the quadratic extrapolation method must be used for braces. The SCF is effectively reduced and more evenly distributed when the value of the axial compression ratio in the chord is increased. Furthermore, the SCFs obtained from the test results were compared to predictions from some well-established SCF equations. Generally, the predictions from those equations are very consistent for braces, but very conservative for concrete-filled chords.

Effects of sizes and mechanical properties of fuel coupon on the rolling simulation results of monolithic fuel plate blanks

  • Kong, Xiangzhe;Ding, Shurong;Yang, Hongyan;Peng, Xiaoming
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1330-1338
    • /
    • 2018
  • High-density UMo/Zr monolithic nuclear fuel plates have a promising application prospect in high flux research and test reactors. The solid state welding method called co-rolling is used for their fabrication. Hot co-rolling simulations for the composite blanks of UMo/Zr monolithic nuclear fuel plates are performed. The effects of coupon sizes and mechanical property parameters on the contact pressures between the to-be-bonded surfaces are investigated and analyzed. The numerical simulation results indicate that 1) the maximum contact pressures between the fuel coupon and the Zircaloy cover exist near the central line along the plate length direction; as a whole the contact pressures decrease toward the edges in the plate width direction; and lower contact pressures appear at a large zone near the coupon corner, where de-bonding is easy to take place in the in-pile irradiation environments; 2) the maximum contact pressures between the fuel coupon and the Zircaloy parts increase with the initial coupon thickness; after reaching a certain thickness value, the contact pressures hardly change, which was mainly induced by the complex deformation mechanism and special mechanical constitutive relation of fuel coupon; 3) softer fuel coupon will result in lower contact pressures and form interfaces being more out-of-flatness.

Evaluation of Corrosion Resistance and Weldability for the Butt Welding Zone of Hot Rolled Clad Steel Plates (열간압연 클래드강의 맞대기용접부 내식성 및 용접성 평가)

  • Park, Jae-Won;Lee, Chul-Ku
    • Journal of Welding and Joining
    • /
    • v.31 no.5
    • /
    • pp.47-53
    • /
    • 2013
  • We have investigated the traits of clad metals in hot-rolled clad steel plates, including the sensitization and mechanical properties of STS 316 steel plate and carbon steel (A516), under various specific circumstances regarding post heat treatment, multilayered welds, and thick or repeated welds for repair. For evaluations, sectioned weldments and external surfaces were investigated to reveal the degree of sensitization by micro vickers hardness, tensile, and etching tests the results were compared with those of EPR tests. The clad steel plates were butt-welded using FCAW and SAW with the time of heat treatment as the variable, a that was conducted at $625^{\circ}C$, for 80, 160, 320, 640, and 1280 min. Then, the change in corrosion resistance was evaluated in these specimens. With carbon steel (A516), as the heat treatment time increased, the annealing effect caused the tensile strength to decrease. The micro-hardness gradually increased and decreased after 640 min. The elongation and contraction of the area also increased gradually. The oxalic acid etch test and EPR test on STS316 and the clad metal showed STEP structure and no sensitization. From the test results on multi-layered and repair welds, it could be concluded that there is no effect on the corrosion resistance of clad metals. The purpose of this study was to suggest some considerations for developing on-site techniques to evaluate the sensitization of stainless steels.

Evaluation of the Laser Weldability of Inconel 713C alloy (인코넬 713C 합금의 레이저 용접성 평가)

  • Kang, Minjung;Kim, Cheolhee;Kim, Young-Min
    • Journal of Welding and Joining
    • /
    • v.35 no.1
    • /
    • pp.68-73
    • /
    • 2017
  • During welding of Ni based superalloy, hot cracking was usually happen in the fusion zone of a weld. In this study, the laser weldability of Inconel 713C alloy for the turbocharger wastegate valve (WGV) was evaluated with various welding conditions, such as laser power, welding speed, shielding gas. Welding conditions were optimized by bead-on-plate (BOP) and butt joint welding. For the evaluation of laser weldability, bead shapes and weld microstructures were investigated and tensile test was conducted. The fracture surfaces were investigated for the understanding the cause of the fracture.

Anti-nociceptive Activity of Methanol Extracts from Ligularia stenocephala (곤달비 메탄올 추출물의 진통 효과)

  • Cha, Dong Seok;Jeon, Hoon
    • Korean Journal of Pharmacognosy
    • /
    • v.44 no.1
    • /
    • pp.70-74
    • /
    • 2013
  • Ligularia stenocephala has been widely used as a traditional medicine for the treatment of lots of diseases such as asthma, arthritis, and jaundice. In this study, we evaluated the anti-nocicepitve activities of methanolic extract of L. stenocephala (MLS) using various pain models including thermal nociception as well as chemical nociception methods. MLS showed significant increase in latency time in the tail immersion test and hot-plate test. In addition, the number of acetic acid-induced abdominal constrictions was decreased by MLS. MLS also attenuated paw licking time in the formalin test. The combination test using naloxone revealed that the anti-nociceptive properties of MLS was not associated with opioid receptor activation. The present results demonstrate that MLS may possibly used as valuable analgesic agent for the treatment of nociceptive pain.

The Analgesic Effect and Its Neuropathologic Changes of Pulsed Radiofrequency Lesions in the Sciatic Nerve of the Rat (백서 좌골신경에 시행한 박동성 고주파술 (Pulsed Radiofrequency)이 급성 통증과 신경조직에 미치는 영향)

  • Lee, Kee-Heon;Shin, Keun-Man;Kweon, Kyoung-Seok;Jung, Bae-Hee;Lim, So-Young;Hong, Soon-Yong;Choi, Young-Hee;Park, Young-Euy
    • The Korean Journal of Pain
    • /
    • v.13 no.2
    • /
    • pp.149-155
    • /
    • 2000
  • Background: Pulsed radiofrequency (RF) lesioning is a painless procedure and causes no neurodestruction and neuritis-like reaction are common following conventional RF lesioning. There is little data about the effect of pulsed RF especially with regard to its suitability for the treatment of acute pain. The possibility of a placebo effect cannot be ruled out because a double-blind study was not performed in previous studies. There is also no neuropathologic study about pulsed RF. Methods: The rats were anesthetized with sodium pentobarbital (40 mg/kg, i.p.; supplemented as necessary). The common sciatic nerve was exposed by blunt dissection through biceps femoris. Pulsed RF was administered to the common sciatic nerve using a 30 ms/s pulse with for 120 seconds. The temperature reached was no more than $42^{\circ}C$. Analgesia was determined using hot-plate assay shortly and, 3 days and 1 week before, and 2 weeks after operation. Lesions were examined with LM (light microscope) and EM (electron microscope) 2 weeks later. Results: There were no differences in response latencies between the control and experimental group. There were many vacuoles with hyaline bodies in the Schwann cell cytoplasm rather than axon in LM and larger electron dense bodies. No changes were found in the axon or unmyelinated fibers. Only small changes were found in the sheaths of myelinated fibers and Schwann cells. Conclusions: We therefore do think that any analgesic effect of pulsed RF is not a result of block of neural conduction. But rather than it can be attributed to others factors. It was also ineffective as a treatment for acute pain such as that caused by the hot-plate test.

  • PDF

The Experimental Study of Electroacupuncture and Cervi Pantortichum Cornu Pharmacopuncture on Pain Decrease and Nerve Regeneration after Crush Injury of Sciatic Nerve (좌골신경 압좌 손상 후 전침 및 녹용 약침의 통증 감소와 신경 재생에 관한 실험적 연구)

  • Ahn, Hye-Lim;Yang, Mi-Sung;Shin, Mi-Sook;Choi, Jin-Bong;Kim, Sun-Jong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.1
    • /
    • pp.39-55
    • /
    • 2009
  • Objectives : This study was designed to evaluate effects of electroacupuncture and Cervi Pantortichum Cornu pharmacopuncture on pain and nerve regeneration after crush injury of sciatic nerve in rats. Methods : We divided the subjects into 5 groups : control group, acupuncture treated group, electroacupuncture treated group, Cervi Pantortichum Cornu pharmacopuncture treated group, electroacupuncture and Cervi Pantortichum Cornu pharmacopuncture group. Hot plate test and degree of Substance P antibody in each group were observed at the 1st, 2nd, 3rd and 5th day. Sciatic function index and change of BDNF immunoreactivity had been estimated at the 7th, 14th, 21st day respectively. Atrophy of the gastrocnemius at the 21st day was observed. Results : All the experimental groups showed significant changes in hot plate test, degree of Substance P antibody, sciatic function index and change of BDNF immunoreactivity compared with control group. Especially, when electroacupuncture and Cervi Pantortichum Cornu pharmacopuncture used together, results were more effective than other groups. Recovery of the gastrocnemius was also the same. Conclusions : It is suggested that electroacupuncture and Cervi Pantortichum Cornu pharmacopuncture may play a significant role on pain decrease and nerve regeneration after crush injury of sciatic nerve in rats and these two treatments could be more effective when used together.

Anti-inflammatory and Antinociceptive Properties of the Ethanolic Extract of Gleditsia sinensis and its Sub-fractions (조각자 에탄올 추출물 및 그 분획의 항염증 및 진통효능)

  • Yoon, Byung-Hoon;Park, Se-Jin;Shin, Bum-Young;Jung, Jae-Bark;Shin, Ji-Sun;Jang, Young-Pyo;Lee, Kyung-Tae;Ryu, Jong-Hoon
    • Korean Journal of Pharmacognosy
    • /
    • v.42 no.4
    • /
    • pp.317-322
    • /
    • 2011
  • Traditionally, the thorns of Gleditsia sinensis LAM. (GS) have been used for the treatment of various types of cancer and heart, skin, vascular and inflammatory diseases. However, there have been no reports on the antinociceptive or antiinflammatory properties of the thorn of GS. The present study was carried out to evaluate the anti-inflammatory and antinociceptive effects of the ethanolic extract of GS (EEGS) and its sub-fractions. The administration of EEGS (500 mg/kg) or its butanolic fraction (50 and 100 mg/kg) reduced the frequency of the acetic acid-induced writhing reflex in mice. In addition, the administration of the butanolic fraction of EEGS (50 and 100 mg/kg) prolonged the latency of reaction at the hot plate in mice. The butanolic fraction of EEGS also inhibited lipopolysaccharide-induced nitric oxide, prostaglandin $E_2$, and tumor necrosis factor-$\acute{a}$ production in the RAW 264.7 cell line. These results suggest that EEGS has anti-inflammatory and analgesic properties and is a potential therapeutic for inflammation and nociception.