Stack Effect in High-Rise Buildings: A Review

  • Mijorski, Sergey;Cammelli, Stefano
    • 국제초고층학회논문집
    • /
    • 제5권4호
    • /
    • pp.327-338
    • /
    • 2016
  • This technical paper presents a detailed review of the stack effect phenomenon and of the associated implications pertaining to the design and construction of high-rise buildings in regions of extreme climatic conditions. The present review is focused on both the classical 'chimney' effect as well as on the reverse stack effect, which are respectively related to cold and hot climates. For the purposed of the work here presented, the ASHRAE (2013) design conditions of Astana (Kazakhstan) and Riyadh (Kingdom of Saudi Arabia) were selected. A 230 m tall residential building of rectangular floor plan was numerically modelled in the context of the climatic conditions of the two abovementioned cities and a number of sensitivity analyses were performed, covering parametric changes of: temperature, façade air tightness, site wind speeds and wind directions.

표준축사 모델에서 PEB시스템의 적용 및 구조설계 개선방안 (Solution for the Improvement in Structural Design & Application of PEB System for the Standard Livestock Housing(2008))

  • 박만우;도병호;송준익
    • 한국축산시설환경학회지
    • /
    • 제15권1호
    • /
    • pp.17-28
    • /
    • 2009
  • PEB system is more economical when compared with structures commonly used Hot rolled and welded light H-beam was introduced in the Standard Livestock Housing. This study suggested more economical technology for structural design by the reduction of live load, relief of deflection limit and reduction of importance factor. And, when applying wind Load as a result of examination with Low Rise Building Systems Manual considering open model, we can know that when the wind load is big, enclosed model is more stable than open model. In short, Suggesting more economical model and providing the method to reduce natural disaster, by the application of PEB system and the development of technology for structural design, are considered to strengthen the competitive power of farmhouse.

  • PDF

Design and testing of a low subsonic wind tunnel gust generator

  • Lancelot, Paul M.G.J.;Sodja, Jurij;Werter, Noud P.M.;Breuker, Roeland De
    • Advances in aircraft and spacecraft science
    • /
    • 제4권2호
    • /
    • pp.125-144
    • /
    • 2017
  • This paper summarises the design of a gust generator and the comparison between high fidelity numerical results and experimental results. The gust generator has been designed for a low subsonic wind tunnel in order to perform gust response experiments on wings and assess load alleviation. Special attention has been given to the different design parameters that influence the shape of the gust velocity profile by means of CFD simulations. Design parameters include frequency of actuation, flow speed, maximum deflection, chord length and gust vane spacing. The numerical results are compared to experimental results obtained using a hot-wire anemometer and flow visualisation by means of a tuft and smoke. The first assessment of the performance of the gust generator showed proper operation of the gust generator across the entire range of interest.

천음속 유동하의 압축기 익형에 대한 실험적 연구 (An Experimental Study of Compressor Section Profile in Transonic Flow)

  • 류영진
    • 한국추진공학회지
    • /
    • 제5권2호
    • /
    • pp.8-15
    • /
    • 2001
  • 터보기계의 효율 향상을 위한 끊임없는 노력에서 익형 형상 설계는 대단히 중요한 부분을 차지하고 있다. 이와 관련하여 천음속 풍동에서 층류 및 난류 경계층 거동(충격파-경계층 상호작용)에 대한 실험적 연구가 CTA 열전대 측정을 통해 이루어졌다. 압축기 익형에 부착된 열전대 실험 결과는 유동의 복잡성에 기인하는 신호의 불명확성 때문에 해석이 대단히 어려운 점이 있으므로 설계자에게 열전대 신호 특성에 대한 정확한 정보를 주기 위해서 다른 측정장치 결과와 비교 분석을 통한 해석기법 이 개발되었다.

  • PDF

친환경 농촌마을계획을 위한 주거 에너지 이용실태 조사 분석 (An Investigation and Analysis on Actual Condition of Energy Utilizations in Farmhouse for Environmental-friendly Planning of Rural Villages)

  • 남상운;김대식
    • 한국농공학회논문집
    • /
    • 제49권6호
    • /
    • pp.55-62
    • /
    • 2007
  • Actual states of energy utilizations were investigated and analyzed on three representative rural villages in Chungcheongnam-Do. Rural residents were almost using the ondol boiler as a heating facility and oil(diesel, kerosene) and electricity(night thermal-storage power service) as a heating energy. There were a few households using briquette or firewood in a fuel hole with Korean hypocaust. Most of their cooking facilities were gas ranges using LPG. The most popular hot-water supply system was an oil boiler and the next was an electricity boiler. The amount of energy use in a rural household generally showed 20,000 to 40,000 won/month of the electric power rate, 400 to 800 liter/year of the oil and 60 to 120 kg/year of the LPG. Prompt measures should be taken to promote the spread of new and renewable energy such as solar heat, biomass and wind power, etc.

혹서기(酷暑期) 환경요인(環境要因)에 의한 전통주거건축(傳統住居建築)의 공간구성(空間構成)에 관한 연구 - 전북지방 농촌주택(農村住宅)을 중심으로 - (A Study on the Chracter of Spatial Organization in traditional House by hot Weather environmental Factors - Focused on the rural house in Chonbuk province -)

  • 김용집
    • 건축역사연구
    • /
    • 제7권2호
    • /
    • pp.49-62
    • /
    • 1998
  • The character of spatial organization in rtaditional house is found through the analysis of field survey and measure of its micro climate in hot weather period of summer. The mean temperature of interior space is higher than outside space of the house. In the point of structural conditions, inside of Choga in caustal and mountain area is cooler than any other houses. In inland area, slate roof house is cooler than Choga. In mountain area, the thermal difference of inside and outside in Kyubjib is higher than Hotjib. In the point of spatial conditions, kitchen is the coolest space and very suitable for spatial organization. Anbang is the hottest space because of its centeral position in the house. In wind condition, mountain area is windy and caustal area is calm. Around the house the rear side of the house is windy and left side is calm.

  • PDF

고속(KTX) 및 기존 철도차량의 열차풍 현상 비교 분석 (The Comparative Analysis of Slipstream Phenomena by High-Speed and Traditional Train)

  • 김동현;장용준
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.173-180
    • /
    • 2007
  • A series of field tests were performed to develop aerodynamic characteristic evaluation method and countermeasure technology in conventional and high-speed railway. The strength of rolling stock-induced wind which affect the people and substructure in platform and nearby track were investigated. The slipstream of passing trains was measured by hot-wire array system. The speed of trains was 110 - 125km/h for conventional ones and 300km/h for high-speed ones. The streamlined shape trains cause about 50% smaller-scale slipstream compared to the non-streamlined ones.

A Study on a High Efficiency Dryer for Food Waste

  • Kim, Bum-Suk;Kang, Chang-Nam;Jeong, Ji-Hyun
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.153-158
    • /
    • 2014
  • The food waste that occurs in one year is very high in our country and disposal is expensive. However, disposers for food waste are not used wisely at real life. This is because most of them some kind of problem, for example big volume, complicated construction, high cost, lots of troubles, low energy efficiency and so on. In this study, we propose the new dryer system to decrease drying times by injecting hot air in down the side of the drying bucket. The designed drying bucket has inclined inlet holes down both sides. The inlet holes have variable gradients, we adjust the inlet velocity of the hot air to find a suitable vortex in the drying bucket. We verify the properties of the proposed system though simulation. The results show the proposed dryer system can improve the drying time and save energy for food waste disposal.

Processes of Outflow of the Boiling Steam-Water Mixture in the Widening Part of Hydro-Steam Turbine Nozzles

  • Leonid, Serejkin;Boris, Shifrin;Victor, Perov;Alexandr, Goldin
    • International Journal of Computer Science & Network Security
    • /
    • 제22권12호
    • /
    • pp.178-184
    • /
    • 2022
  • Renewable energy sources based on solar radiation, wind energy, geothermal energy, and biomass energy have now reached the level of industrial application. A new way to generate electricity using low-potential heat is to install a hydro-steam turbine. In hydro-steam turbines, hot water is supplied directly to turbine rotor nozzles without prior separation into steam and water in separators, which significantly increases the efficiency of hot water energy use. Such turbines are suggested to be used as autonomous energy sources in geothermal heating systems, heating water boilers and cooling systems of chemical reactors, metallurgical furnaces, etc. The authors conclude that the installation of hydro-steam turbines in heating plants and process boiler plants can also be effective if the used exhaust steam-water mixture at the turbine outlet is used to heat the network water or as return water.

해상풍력발전용 타워플랜지 소재의 잉고트 파쇄공정설계 (Ingot-Breakdown Design of Tower Flange Material for Offshore Wind Turbine)

  • 유가영;강남현;김정한;홍재근;이종수;이진모;김남용;염종택
    • 소성∙가공
    • /
    • 제21권7호
    • /
    • pp.412-419
    • /
    • 2012
  • The ingot-breakdown scheme of a tower flange material (low-alloy steel) for offshore wind turbine was investigated using finite element (FE) simulations and experimental analyses. Based on compression test results of the low-alloy steel, a deformation processing map was generated using the superposition approach between the dynamic materials model (DMM) and Ziegler's instability criterion. The deformation processing map allowed determination of the optimum process conditions for the tower flange material. Within the FE simulations of the ingot breakdown process, the Cockcroft-Latham criterion, which considers ductile fracture, was used to predict the possibility of forming defects during the hot working process. In general, the critical value for the ductile fracture of steel is 0.74. During the ingot-breakdown under optimum process conditions, the actual tower flange forgings exhibited a relatively uniform shape without any forming defects.