• 제목/요약/키워드: Hot Wind

검색결과 239건 처리시간 0.019초

파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험- (Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment-)

  • 하만영;이대래
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3695-3705
    • /
    • 1996
  • We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.

유동고온공기에 의해 유인되는 수평평판 액막류의 열전달에 관한 실험적 연구 (An Experimental study on Heat Transfer Characteristics of Horizontal Liquid Film Driven by Hot Wind)

  • 박재현;박상균;윤석훈;오철;김명환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.83-88
    • /
    • 2002
  • This study is to provide the experimental information and basic data on heat transfer characteristics of horizontal liquid film driven by hot wind. Heat transfer characteristics of the liquid film in the rectangular duct was observed and the change of film temperature was measured. The experiments were carried out for a variety of parameter, such as feed water rate and velocity and temperature of feed air. From the observation and the measurement the general understanding of heat transfer characteristics for liquid film driven by hot wind was provided.

  • PDF

실험을 통한 풍력발전기의 후류구조 분석 (Wake Analysis of the HAWT by Windtunnel Test)

  • 박지웅;김호건;신형기;이수갑
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.273-276
    • /
    • 2006
  • To generate electricity from wind energy, wind turbine generally has a rotor blade. Since this rotor blade is a kind of the rotating machinery, the wake from the rotor is very Important role in the side of the aerodynamic performances. Thus the study about wake is essential to analyze wind turbine aerodynamics. In this study wake characteristics are analyzed by hot-wire probe in the K.A.F.A(Korea Air Force Academy) wind tunnel. It is possible to analyze the wake characteristics by hot-wire probe from acquiring the velocity fluctuations at given positions in the flow. This velocity data are arranged by trigger signal at same azimuth of the blade in periodic manner of the rotor blade. From this various wake characteristics are found : radial and axial position of the tip vortex, vortex core characteristics in the flow etc.

  • PDF

무선 체감온도 측정 시스템 개발 (Development of wireless wind chill temperature measurement system)

  • 김형표;김진규;손경락
    • 센서학회지
    • /
    • 제18권3호
    • /
    • pp.245-250
    • /
    • 2009
  • The paper presents the wireless wind chill temperature measurement system that is composed of IEEE 802.15.4 standard wireless communication devices, hot film anemometer and serial communication temperature sensor. It's sometimes very difficult for a person, who lives in a high-rise apartment, to see the outside wind chill temperature due to harsh outside weather. The wind chill temperature is calibrated from an air velocity and air temperature. IEEE 802.15.4 standard wireless communication is ZigBee compatible, and consumes low power in communication. Under the air temperature of 5 $^{\circ}C$ and air velocity ranging from 0 to 50 km/h, the experimental result of wind chill temperature shows good accuracy within 5%.

주변 온도보상이 필요 없는 열선식 풍속 센서 시스템 (Hot Wire Wind Speed Sensor System Without Ambient Temperature Compensation)

  • 성준규;이근우;정회경
    • 한국정보통신학회논문지
    • /
    • 제23권10호
    • /
    • pp.1188-1194
    • /
    • 2019
  • 유체의 흐름을 측정하는 여러 방법 중 열선 풍속 센서는 유체의 열전달에 의해 속도나 온도를 측정하는 장치로 비정상 속도 및 난류 속도 성분을 측정하는데 유용하다. 하지만 열선 풍속 센서는 외부의 환경 요인에 민감하며, 주변 온도, 습도, 신호 잡음 등에 의해 정확도가 떨어지는 단점이 있다. 이런 단점을 보완하는 방법으로 온도 보상 회로를 추가하는 기술이 나오고 있지만 가격 경쟁력을 갖출 수 없는 상황이다. 이를 해결하기 위해 본 논문에서는 온도 보상이 필요 없는 풍속 감지 센서에 대해 연구를 진행하였다. 열선식 풍속 센서는 외부 환경 요인 중에서도 주변 온도에 매우 취약하다. 주변 온도로는 전자 회로에 의한 발열의 영향이 가장 크게 미치고 있으며, 이를 개선하는 방법으로 발열체에 보조 발열체를 추가로 장착하여 보조발열체와 발열체의 일정한 온도차를 제어하는 것이다. 이와 같이 기존 기술에 비해 복잡하지 않은 방법으로 동등한 성능을 확보할 수 있다는 것을 확인할 수 있었다.

계기착륙장치 타워가 풍속관측에 미치는 영향에 관한 풍동실험연구 (A Wind Tunnel Study on Influences of ILS Tower on Wind Speed Measurement)

  • 최철민;김계환;김영철;권기범
    • 대기
    • /
    • 제23권4호
    • /
    • pp.513-517
    • /
    • 2013
  • In this study, it is first intended to simulate the vertical profile of atmospheric flow in a short wind tunnel. In order to accomplish it, proper devices are designed properly to reduce freestream flow momentum and it is confirmed from the measured velocity profile using hot-wire anemometer that momentum flux of the tunnel free stream can be reduced and desired atmospheric boundary can be created. Second, experiments are performed to identify influences of a surrounding structure measuring correct wind velocity by an anemometer, which are located nearby due to area limitation in actual airport and correction factors are proposed from experimental results. One of findings is that in order to limit the velocity attenuation due to a nearby structure under 10%, wind velocity measuring equipment should be installed at least 6 times of the structure height away from the structure of concern.

An active grid for the simulation of atmospheric boundary layers in a wind tunnel

  • Talamelli, A.;Riparbelli, L.;Westin, J.
    • Wind and Structures
    • /
    • 제7권2호
    • /
    • pp.131-144
    • /
    • 2004
  • A technique for the simulation of atmospheric boundary layers in wind tunnels is developed and tested experimentally. The device consists of a grid made of seven horizontal and vertical evenly distributed bars in which air injection holes are drilled in order to influence the flow in the wind tunnel. The air flow in each bar can be controlled independently. Firstly, the device is used together with a rough carpet, which covers the test section floor, in order to simulate the boundary-layer characteristics over an open rural area. Hot-wire measurements, performed at different positions in the test-section, show the capability of the grid in generating the required boundary layer. An acceptable agreement with statistical values of mean velocity and turbulence profiles has been achieved, together with a good span-wise homogeneity. The results are also compared with those of a passive simulation technique based on the use of spires.

풍동실험을 이용한 다공성 방풍팬스의 방풍성능실험 (Experiment of the Shelter Effect of Porous Wind Fences base on the Wind Tunnel Test)

  • 유장열;전종길;김영문
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2006년도 춘계 학술발표회 논문집 제3권1호(통권3호)
    • /
    • pp.91-101
    • /
    • 2006
  • We have conducted the study about the shelter effect against the wind by using the wind fence with various porosities and the measured distance from the wind fence, in three different types of it ; (Circle wind fence, Vertical wind fence, Horizontal wind fence) The shelter effect and turbulence characteristics of the selected wind barrier is throughly investigated by wind tunnel test. flow characteristics of velocities and turbulences behind wind fence were measured using hot-wire anemometer. we characterize the turbulence behind the wind fence by varying the porosity of 0 %, 20 %, 40%, and 60%, and the distances from the wind fence from 1 H to 9 H with maintaining the uniform flow velocity of 6 m/s. In addition, we investigated the overall characterization of the wind fence by measuring total of twenty eight points on the wind fence, which forms the lattice structure on it with seven points in lateral direction and four points in vertical direction. The results of analysis from the circle wind fence indicate that the degree of the turbulence is lowered and the velocity of the wind is decreased when the porosity of 40 % are used at the distance from 3 H to 9 H. On the other hand, the vertical, horizontal wind fence with the porosity of 20% is more advantageous at the distance of 2 H to 9 H. For the effectiveness of the wind fence depending on the position, the center part is the greatest and it decreases at the edges with 10 % to 30 % less than that of at the center.

  • PDF

한양대학교 중형 아음속 풍동의 공력특성에 관한 연구 (Study on the Aerodynamic Characteristics of Hanyang Low Speed Wind Tunnel)

  • 고광철;정현성;김동화;조진수
    • 한국항공우주학회지
    • /
    • 제31권4호
    • /
    • pp.92-98
    • /
    • 2003
  • 한양대학교 중형 아음속 풍동의 설계요구사항에 따라 균일도 증가 및 난류도 감소를 위한 최적설계를 수행하였다. 신뢰성 있는 풍동실험을 위해 먼저 풍동 시험부의 균일도와 난류강도 특성이 먼저 파악되어야 한다. 한양대학교 중형 아음속 풍동의 비균일도와 난류강도는 세 부분의 속도영역에서 피토관과 X형 열선프로브로 각각 측정되었다. 풍동 시험부의 유속이 증가함에 따라 비균일도가 작아졌으나 시험부의 측정단면이 확산부에 가까워질수록 비균일도가 크게 나타났다. 난류강도는 시험부 중앙에서 설계 요구조건에 비해 약간 높게 측정되었다.

원형방풍팬스 후면에 있는 저층건물의 풍압특성 (The Characteristic of Wind Pressure of Low-rise Building Located Behind a Circle Wind Fence)

  • 전종길;유장열;유기표;김영문
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2006년도 춘계 학술발표회 논문집 제3권1호(통권3호)
    • /
    • pp.102-109
    • /
    • 2006
  • The effects of wind fence on the pressure characteristics around low-rise building model were investigated experimentally. Flow characteristics of turbulences behind wind fence were measured using hot-wire anemometer. The wind fence characterize by varying the porosity of 0 %, 40 % and the distances from the wind fence from 1 H to 6 H with maintaining the uniform flow velocity of 6 m/s. We investigated the overall characterization of the low-rise building by measuring pressure seventy four on model. The effects of porosity fences varied with the porosity of the fence and measurement locations(1H-6H). The 0% porosity proved to be effective for the protection area of 4H to 6H, but the 40% porosity proved to be effective for the protection area of 1H to 6H. The low-rise building of front face was found to be best wind fence for decreasing the mean, maximum and minimum pressure fluctuation.

  • PDF