Transactions of the Korean Society of Mechanical Engineers B (대한기계학회논문집B)
- Volume 20 Issue 11
- /
- Pages.3695-3705
- /
- 1996
- /
- 1226-4881(pISSN)
- /
- 2288-5324(eISSN)
DOI QR Code
Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment-
파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험-
- Ha, Man-Yeong (School of Mechanical Engineering, Pusan National Uinversity) ;
- Lee, Dae-Rae
- Published : 1996.11.01
Abstract
We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.