• Title/Summary/Keyword: Hospital medicine

Search Result 33,728, Processing Time 0.063 seconds

A STUDY ON THE PERSONALITY TRAIT OF BULLYING & VICTIMIZED SCHOOL CHILDRENS (학령기 집단따돌림 피해 및 가해아동의 인격성향에 관한 연구 - 한국아동인성검사를 이용하여 -)

  • Jhin, Hea-Kyung;Kim, Jong-Won;Choi, Yun-Jung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.12 no.1
    • /
    • pp.94-102
    • /
    • 2001
  • Bullying has recently become a serious social problem in Korean society. Bullying, which is defined as a phenomenon that one particular student is intensively and continuously harassed or ostracized by a group of students, is apt to produce harmful effects on bullies as well as victims. Bullying has many causes including those originated from the personality of victims and bullies. This study is designed to investigate the difference in personality trait between victims, bullies, victims/bullies, and neither. The subjects of this study were 215(115 male and 100 female) 6th-grade students in the primary school in Seoul. Questionnares were distributed to the students and their carers. The student carers were also asked to answer the questions for a survey called the Korean Personality Invertory for Children(KPI-C). SPSS was used for the statistical analysis of the collected test information;ANOVA, post hoc scheffe test, and T-test were used to analyze the differences between the tested groups. The result of the study is as follows. 1) The victims, bullies, victims/bullies and neither totaled respectively 11(5.1%), 56(26.0%), 11(5.1%) and 137(63.7%). 115 were male and 100 were female. 2) The frequency of victimized is as follows:1 time is 15(7.0%), 2 times is 4(1.9%) and more than 3 times is 3(1.4%). The frequency of bullying is as follows;1 time is 40(18.6%), 2 times is 17 (7.9%) and more than 3 times is 10(4.7%). 3) The differences between froups in KPI-C test is as follows. (1) The ESR(p=.00) scale was significantly lower in the victims group than in the neither group and the HPR(p=.00) scale and PSY(p<.01) scale were significantly higher in the former than in the latter. (2) The ESR(p=.00) scale was significantly lower in the victims/bullies group than in the neither group and the SOM(p=.00) scale and HPR(p=.00) scale were significantly higher in the formaer than in the latter. (3) The SOC(p=.00) scale, PSY(p<.01) scale and AUT(p=.00) scale were significantly higher in the victims group than in the bullies group. (4) There is statistically no difference between the bullies group and the neither group. To conclusion, Victims need to learn how to cope with harsh situations, or they will have to face difficulties in relationships. Even after they experience bullying, they may not realize why they have been bullied, or speak out for themselves.

  • PDF

Results of Radiation Therapy for Carcinoma of the Uterine Cervix (자궁경부암의 방사선치료 성적)

  • Lee Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.359-368
    • /
    • 1995
  • Purpose : This is a retrospective analysis for pattern of failure, survival rate and prognostic factors of 114 patients with histologically proven invasive cancer of the uterine cervix treated with definitive irradiation. Materials and Methods : One hundred fourteen patients with invasive carcinoma of the cervix were treated with a combination of intracavitary irradiation using Fletcher-Suit applicator and external beam irradiation by 6MV X-ray at the Ewha Womans University Hospital between March 1982 and Mar 1990. The median age was 53 years(range:30-77 years). FIGO stage distribution was 19 for IB, 23 for IIA, 42 for IIB, 12 for IIIA and 18 for IIIB. Summation dose of external beam and intracavitary irradiation to point A was 80-90 Gy(median:8580 cGy) in early stage(IB-IIA) and 85-100 Gy(median:8850 cGy) in advanced stage(IIB-IIIB). Kaplan-Meier method was used to estimate the survival rate and multivariate analysis for progrostic factors was performed using the Log likelihood for Weibull Results : The pelvic failure rates by stage were $10.5{\%}$ for IB. $8.7{\%}$ for IIA, $23.8{\%}$ for IIB, $50.0{\%}$ for IIIA and $38.9{\%}$ for IIIB. The rate of distant metastasis by stage were $0{\%}$ for IB, $8.7{\%}$ for IIA, $4.8{\%}$ for IIB. $0{\%}$ for IIIA and $11.1{\%}$ for IIIB. The time of failure was from 3 to 50 months and with median of 15 months after completion of radiation therapy. There was no significant coorelation between dose to point A($\leq$90 Gy vs >90 Gy) and pelvic tumor control(P>0.05). Incidence rates of grade 2 rectal and bladder complications were $3.5{\%}$(4/114) and $7{\%}$(8/114), respectively and 1 patient had sigmoid colon obstruction and 1 patient had severe cystitis. Overall 5-year survival rate was $70.5{\%}$ and disease-free survival rate was $53.6{\%}$. Overall 5-year survival rate by stage was $100{\%}$ for IB, $76.9{\%}$ for IIA, $77.6{\%}$ for IIB $87.5{\%}$ for IIIA and $69.1{\%}$ for IIIB. Five-rear disease-free survival rate by stage was $81.3{\%}$ for IB, $67.9{\%}$ for IIA, $46.8{\%}$ for IIB, $45.4{\%}$ for IIIA and $34.4{\%}$ for IIIB. The prognostic factors for disease-free survival rate by multivariate analysis was performance status(p= 0.0063) and response rate after completion of radiation therapy(p= 0.0026) but stage, age and radiation dose to point A were not siginificant. Conclusion : The result of radiation therapy for early stage of the uterine cervix cancer was relatively good but local control rate and survival rate in advanced stage were poor inspite of high dose irradiation to point A above 90 Gy. Prospective randomized studies are recommended to establish optimal tumor doses for various stages and volume of carcinoma of uterine cervix, And ajuvant chemotherapy or radiation-sensitizing agents must be considered to increase the pelvic control and survival rate in advanced cancer of uterine cervix.

  • PDF

CLINICAL STUDY OF THE ABUSE IN PSYCHIATRICALLY HOSPITALIZED CHILDREN AND ADOLESCENTS (소아청소년 정신과병동 입원아동의 학대에 대한 임상 연구)

  • Lee, Soo-Kyung;Hong, Kang-E
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.10 no.2
    • /
    • pp.145-157
    • /
    • 1999
  • This study was performed by the children and adolescents who were abused or neglected physically, emotionally that were selected in child & adolescents psychiatric ward. We investigated the number of these case in admitted children & adolescents, and also observed characteristics of symptoms, developmental history, characteristics of abuse style, characteristics of abusers, family dynamics and psychopathology. We hypothesized that all kinds of abuse will influnced to emotional, behavioral problems, developmental courses on victims, interactive effects on family dynamics and psychopathology. That subjects were 22 persons of victims who be determined by clinical observation and clinical note. The results of the study were as follows:1) Demographic characteristics of victims:ratio of sex was 1:6.3(male:female), mean age was $11.1{\pm}2.5$. According to birth order, lst was 12(54.5%), 2nd was 5(23%), 3rd was 2(9%) and only child was 3(13.5%). 2) Characteristics of family:According to socioeconomic status, middle to high class was 3(13.5%), middle one was 9(41.% ), middle to low one was 9(41%), low one was 1(0.5%). according to number of family, under the 3 person was 3(13.5%), 4-5 was 17(77.5%), 6-7 was 2(9%). according to marital status of parents, divorce or seperation were 5(23%), remarriage 2(9%), severe marital discord was 19(86.5%). In father, antisocial behavior was 7(32%), alcohol dependence was 10(45.5%). In mother, alcohol abuse was 5(23%), depression was 17(77.3%), history of psychiatric management was 6(27%). 3) Characteristics of abuse:Physical abuse was 18(81.8%), physical and emotional abuse and neglect were 4(18.2%). according to onset of abuse, before 3 years was 15(54.5%), 3-6 years was 5(27.5%), schooler was 1(15%). Only father offender was 2(19%), only mother offender was 8(35.4%), both offender was 8(35.4%), accompaning with spouse abuse was 7(27%), and accompaning with other sibling abuse was 4(18.2%). 4) General characteristics and developmental history of victims:Unwanted baby was 12(54.5%), developmental delay before abuse was9(41%), comorbid developmental disorder was 15(68%). there were 6(27.5%) who didn‘t show definite sign of developmental delay before abuse. 5) Main diagnosis and comorbid diagnosis:According to main diagnosis, conduct disorder 6(27.3%), borderline child 5(23%), depression4(18%), attention deficit hyperactivity disorder(ADHD) 4(18%), pervasive developmental disorder not otherwise specified 2(9%), selective mutism 1(5%). According to comorbid diagnosis, ADHD, borderline intelligence, mental retardation, learning disorder, developmental language disorder, oppositional defiant disorder, chronic tic disorder, functional enuresis and encoporesis, anxiety disorder, dissociative disorder, personality disorder due to medical condition. 5) Course of treatment:A mean duration of admission was $2.4{\pm}1.5$ months. 11(15%) showed improvement of symtoms, however 11(50%) was not changed of symtoms.

  • PDF

Investigation of Poultry Farm for Productivity and Health in Korea (한국에 있어서 양계장의 실태와 닭의 생산성에 관한 조사(위생과 질병중심으로))

  • 박근식;김순재;오세정
    • Korean Journal of Poultry Science
    • /
    • v.7 no.2
    • /
    • pp.54-76
    • /
    • 1980
  • A survey was conducted to determine the status of health and productivity of poultry farms in Korea. Area included Was Kyunggido where exist nearly 50% of national poultry population. From this area, 41 layer and 34 broiler farms covering 21 Countries were selected randomly for the survey. When farms were divided in the operation size, 95.1% of layer and 82.3% of broiler farms were classified as business or industrial level while the rest were managed in a small scale as part time job. Generally layer farms had been established much earlier than broiler farms. Geographically 10.7% of layer farms were sited near the housing area such as field foreast and rice field. No farms were located near the seashore. The distance from one farm from the other was very close, being 80% of the farms within the distance of 1km and as many as 28% of the farms within loom. This concentrated poultry farming in a certain area created serious problems for the sanitation and preventive measures, especially in case of outbreak of infectious diseases. Average farm size was 5,016${\times}$3.3㎡ for layers and 1,037${\times}$3.3㎡ for broilers. 89.5% of layer ana 70.6% of broiler farms owned the land for farming while the rest were on lease. In 60% of layer farms welters were employed for farming while in the rest their own labour was used. Majority of farms were equipped poorly for taking necessary practice of hygiene and sanitation. The amount of disinfectant used by farms was considerably low. As many as 97.6% of lave. farms were practised with Newcastle(ND) and fowl pox(F$.$pox) vaccine, whereas only 43.6% and 5.1% of broiler farms were practised with ND and F$.$pox vaccine, respectively. In 17-32.7% of farms ND vaccine was used less than twice until 60 days of age and in only 14.6% of farms adult birds were vaccinated every 4months. Monthly expense for preventive measures was over 200,000W in 32% of farms. Only 4.9-2.7% of vaccine users were soaking advice from veterinarians before practising vaccination, 85% of the users trusted the efficacy of the vaccines. Selection of medicine was generally determined by the farm owner rather than by veterinarans on whom 33.3% of farms were dependant. When diseases outbroke, 49.3% of farms called for veterinary hospital and the rest were handled by their own veterinarians, salesmen or professionals. Approximately 70% of farms were satisfied with the diagnosis made by the veterinarians. Frequency of disease outbreaks varied according to the age and type of birds. The livabilities of layers during the period of brooding, rearing ana adultwere 90.5, 98.9 and 75.2%, respectively while the livalibility of broilers until marketing was 92.2%. In layers, average culling age, was 533.3 day and hen housed eggs were 232.7. Average feed conversion rates of layers and broilers were 3.30 and 2.48, respectively. Those figures were considerably higher than anticipated but still far lower than those in developed countries.

  • PDF

Postoperstive Chemoradiotherapy in Locally Advanced Rectal Cancer (국소 진행된 직장암에서 수술 후 화학방사선요법)

  • Chai, Gyu-Young;Kang, Ki-Mun;Choi, Sang-Gyeong
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Purpose : To evaluate the role of postoperative chemoradiotherapy in locally advanced rectal cancer, we retrospectively analyzed the treatment results of patients treated by curative surgical resection and postoperative chemoradiotherapy. Materials and Methods : From April 1989 through December 1998, 119 patients were treated with curative surgery and postoperative chemoradiotherapy for rectal carcinoma in Gyeongsang National University Hospital. Patient age ranged from 32 to 73 years, with a median age of 56 years. Low anterior resection was peformed in 59 patients, and abdominoperineal resection in 60. Forty-three patients were AJCC stage II and 76 were stage III. Radiation was delivered with 6 MV X rays using either AP-PA two fields, AP-PA both lateral four fields, or PA both lateral three fields. Total radiation dose ranged from 40 Gy to 56 Gy. In 73 patients, bolus infusions of 5-FU $(400\;mg/m^2)$ were given during the first and fourth weeks of radiotherapy. After completion of radiotherapy, an additional four to six cycles of 5-FU were given. Oral 5-FU (Furtulone) was given for nine months in 46 patients. Results : Forty $(33.7\%)$ of the 119 patients showed treatment failure. Local failure occurred in 16 $(13.5\%)$ patients, 1 $(2.3\%)$ of 43 stage II patients and 15 $(19.7\%)$ of 76 stage III patients. Distant failure occurred in 31 $(26.1\%)$ patients, among whom 5 $(11.6\%)$ were stage II and 26 $(34.2\%)$ were stage III. Five-year actuarial survival was $56.2\%$ overall, $71.1\%$ in stage II patients and $49.1\%$ in stage III patients (p=0.0008). Five-year disease free survival was $53.3\%$ overall, $68.1\%$ in stage II and $45.8\%$ in stage III (p=0.0006). Multivariate analysis showed that T stage and N stage were significant prognostic factors for five year survival, and that T stage, N stage, and preoperative CEA value were significant prognostic factors for five year disease free survival. Bowel complication occurred in 22 patients, and was treated surgically in 15 $(12.6\%)$, and conservatively in 7 $(5.9\%)$. Conclusion : Postoperative chemoradiotherapy was confirmed to be an effective modality for local control of rectal cancer, but the distant failure rate remained high. More effective modalities should be investigated to lower the distant failure rate.

A Study on the Visions of Zechariah in the Old Testament from a Perspective of Analytical Psychology (구약성서 '스가랴'서의 환상에 대한 분석심리학적 연구)

  • Sang Ick Han
    • Sim-seong Yeon-gu
    • /
    • v.29 no.1
    • /
    • pp.1-45
    • /
    • 2014
  • Mystic experience such as seeing an vision could be explained as experiencing elusive and mysterious unique existence in religious way. In depth psychology, which is based on unconsciousness like analytical psychology, this could be explained as a something that gives a meaning of life and purpose through discovering health and healing. The importance of primodial experience in depth psychology is that it can possibly discover the base of present acts. In Christian theology, symbolic mystery and truth of religious experience that appear in Christian tradition have interest on human situation. These two fields' approach methods are different, but both show common interest on unique experience which can be said properly as raw experience. Various visions appear in many parts of the Bible. Among many visions, the book of Zechariah, one of the 12 Prophets, describes rich and diverse 8 visions through chapter 1 to chapter 8. However, due to the Genre of revelation, it lacks historicity, and because of vagueness and symbolic meanings, its visions are hard to understand and interpret. Theologically, visions of Zechariah show communality of Israelites by reconstructing kingdom of Judah and church in a way of historical circumstances. Though, these visions could deliver the meaning of an ethnical aspect as reporting continuous conversation between the God and humans. Furthermore, it could mean a personal aspect of the Prophet Zechariah as reaching for a opportunity of new change. Moreover, those who read these visions could try to interpret the meanings of various images which represent meeting mysterious existences. Therefore, the Author would concentrate on the fact that 8 visions in the book of Zechariah, which has not been received much attention to neither Christians nor non-believers, develop in chiastic structure (stylistic contrast), so that tries to interpret the first, second, seventh, and the eighth visions in analytic psychology way. In visions of Zechariah, excepting the 4th vision which probably was inserted later, rest of 7 visions each shows the stage of the hours of darkness. 1st to 3rd visions represent evening, 5th vision represents deep in the night, and 6th to 8th visions represent dawn to morning. Moreover, since structure of visions arranged in chiastic way, horse appears in 1st and 8th vision, measuring rope and measure tools are used as main motif in 2nd and 7th vision. However, same motifs could have different symbolic meanings and roles as visions are formed in different situations and conditions. In the first vision, angels who ride horses look around the world and report it is calm and peaceful. Concerning the political situation back in the day, the world being calm and peaceful in the beginning of evening means that it is not ready to change to a whole new world. Psychologically, if there is no readiness to adopt new world, it means being hopeless. It is sending you a message to get out of those kinds of situation. Moreover, appearance of four angels who rode red, brown, and white horses to a myrtus tree in the valley means that it is time for individuation and it is right and good timing for changing. In second vision, you will be able to see that Israelites had long years being caught in the shadows by foreign country, and long years succumbed by the strength of four horns, which shows the progress of renewing strength and being oneness with oneself from overwhelmed situation by paternity. In seventh vision, meaning of two women bringing the godness of the sky, who were locked up in a rice basket, back to the temple in Babylon is going towards in a level of Self-actualization by separating one's ego captured excessively by matherhood and putting back to a place where it was before. In eighth vision, chariots pulled by horses are scattered far and wide, and horses which went to north had rest in the land of North. After horses and chariots are seen between two mountains of bronze with the image of Self and anima/animus. These images can be explained as the changing progress are almost completed and the God and human, in other words Self and ego are being united and is now time for rest. All of 8 visions contains the conversation between angel and Zechariah who willing to know the meaning of visions. Zechariah asks the angel actively about the meaning of visions because of his wish for Israelites to return home and rebuild church. Conversation among the God, Zechariah, who asks questions until he knows everything, an Angel, who gives answer to given questions, is conversation between ego and anima/animus. Eventually, it is a conversation between Self and ego.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF