Development and Efficiency Evaluation of Auxiliary Shielding using Elbow Support (팔꿈치 지지대를 사용한 보조 차폐 기구의 개발 및 효용성 평가)

  • Hyun-Woo Im;Jae-Suk Kim;Dong-Gu Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.11-20
    • /
    • 2024
  • As the importance of intervention has recently increased, interest in the health of medical staff performing the procedure is increasing. Existing radiation shielding devices have limited the operator's movement and have not been properly used due to the risk of infection, and adequate radiation shielding of the operator's gonads and furthermore, the entire area of the procedure room has not been achieved. An auxiliary shielding device was manufactured by attaching a Bismuth to the elbow support used in the procedure, and the radiation shielding effect was measured. As a result of the measurement, the average spatial dose rate decreased by about 64.8%, and the independent sample t-test analysis showed statistically significant below the significance probability (p<0.05). The use of an auxiliary shielding device is considered to be an effective shielding method that can shield the operator's gonads and reduce the radiation spatial dose rate of the entire area of the procedure room.

Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy (Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리)

  • Shim, Su-Jung;Shim, Jang-Bo;Lee, Sang-Hoon;Min, Chul-Kee;Cho, Kwang-Hwan;Shin, Dong-Oh;Choi, Jin-Ho;Park, Sung-Ill;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • For applying the quality assurance (QA) of volumetric modulated arc therapy (VMAT) introduced in Eulji Hospital, we classify it into three different QA steps, treatment planning QA, pretreatment delivering QA, and treatment verifying QA. These steps are based on the existing intensity modulated radiation therapy (IMRT) QA that is currently used in our hospital. In each QA step, the evaluated items that are from QA program are configured and documented. In this study, QA program is not only applied to actual patient treatment, but also evaluated to establish a reference of clinical acceptance in pretreatment delivering QA. As a result, the confidence limits (CLs) in the measurements for the high-dose and low-dose regions are similar to the conventional IMRT level, and the clinical acceptance references in our hospital are determined to be 3 to 5% for the high-dose and the low-dose regions, respectively. Due to the characteristics of VMAT, evaluation of the intensity map was carried out using an ArcCheck device that was able to measure the intensity map in all directions, $360^{\circ}$. With a couple of dosimetric devices, the gamma index was evaluated and analyzed. The results were similar to the result of individual intensity maps in IMRT. Mapcheck, which is a 2-dimensional (2D) array device, was used to display the isodose distributions and gave very excellent local CL results. Thus, in our hospital, the acceptance references used in practical clinical application for the intensity maps of $360^{\circ}$ directions and the coronal isodose distributions were determined to be 93% and 95%, respectively. To reduce arbitrary uncertainties and system errors, we had to evaluate the local CLs by using a phantom and to cooperate with multiple organizations to participate in this evaluation. In addition, we had to evaluate the local CLs by dividing them into different sections about the patient treatment points in practical clinics.

Postoperative Radiotherapy in the Rectal Cancers Patterns of Care Study for the Years of $1998\~1999$ (직장암의 방사선치료에 대한 Patterns of Care Study: $1998{\sim}1999$년도 수술 후 방사선치료 환자들의 특성 및 치료내용에 대한 분석결과)

  • Kim, Jong-Hoon;Oh, Do-Hoon;Kang, Ki-Moon;Kim, Woo-Cheol;Kim, Won-Dong;Kim, Jung, Soo;Kim, June-Sang;Kim, Jin-Hee;Kil, Hak-Jae;Suh, Chang-Ok;Sohn, Seung-Chang;Ahn, Yong-Chan;Yang, Dae-Sik
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.22-31
    • /
    • 2005
  • Purpose : To conduct a nationwide survey on the principals in radiotherapy for rectal cancer, and produce a database of Korean Patterns of Care Study. Materials and Methods : We developed web-based Patterns of Care Study system and a national survey was conducted using random sampling based on power allocation methods. Eligible patients were who had postoperative radiotherapy for rectal cancer without gross residual tumor after surgical resection and without previous history of other cancer and radiotherapy to pelvis. Data of patients were Inputted to the web based PCS system by each investigators in 19 institutions. Results : Informations on 309 patients with rectal cancer who received radiotherapy between 1998 and 1999 were collected. Male to female ratio was 59 : 41, and the most common location of tumor was lower rectum ($46\%$). Preoperative CEA was checked in $79\%$ of cases and its value was higher than 6 ng/ml in $32\%$. Pathologic stage were I in $1.5\%$, II in $32\%$, III in $53\%$, and IV in $1.6\%$. Low anterior resection was the most common type of surgery and complete resection was peformed in $95\%$ of cases. Distal resection margin was less than 2 cm in $30\%$, and number of lymph node dissected was less than 12 in $31\%$. Chemotherapy was peformed in $91\%$ and most common regimen was 5-FU and leucovorine ($59\%$). The most common type of field arrangement used for the initial pelvic field was the four field box (Posterior-Right-Left) technique ($65.0\%$), and there was no AP-PA parallel opposing field used. Patient position was prone in $81.2\%$, and the boost field was used in $61.8\%$. To displace bowel outward, pressure modulating devices or bladder filling was used in $40.1\%$. Radiation dose was prescribed to isocenter in $45.3\%$ and to isodose line in 123 cases ($39.8\%$). Percent delivered dose over $90\%$ was achieved in $92.9\%$. Conclusion : We could find the Patterns of Care for the radiotherapy in Korean rectal cancer patients was similar to that of US national survey. The type of surgery and the regimen of chemotherapy were variable according to institutions and the variations of radiation dose and field arrangement were within acceptable range.

Gas Typed Digital X-ray Image Sensor Using PDP Fabrication Process (PDP공정을 이용한 가스 방식의 디지털 X-ray 영상 센서)

  • Kim, Chang Man;Kim, Si Hyung;Nam, Ki Chang;Kim, Sang Hee;Song, Kwang Soup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.322-327
    • /
    • 2012
  • Parallel-plate-type scanning sensors have been commercially used for X-ray imaging sensors. In this study, we manufactured the scan typed 1D X-ray image sensor that can be used to obtain scanning images, by using the plasma display panel (PDP) fabrication process. We fabricated drift and pixel electrodes in the glass chamber and injected Xe gas at atmospheric pressure. We evaluated the intensity of a pixel signal depending on the bias voltage on the drift electrode and investigated the characteristics of shielding effect on the single pixel using lead (Pb). The adsorption rate of X-ray photon is low (4%) on the soda lime glass (1.1mm) and the electrical signal detected on the X-ray sensor was increased in the high bias voltage. We acquired digital X-ray scanning image with our DAS (data acquisition system) and sensor scanning system.

A Study of The Secure Mobile Healthcare System for Medical Grid Devices (메디컬 그리드 장치를 위한 안전한 모바일 헬스케어 시스템에 관한 연구)

  • Choi, Gyoo-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.89-95
    • /
    • 2008
  • The introduction of wireless information technology gives rise to new mobile services in all kinds of areas of out daily life. Mobile healthcare system is a production of composite ICT (Information and Communication Technology) which focused on signal sensing, processing, and communication in wireless environment. The mobile and wireless revolution promises not only expanded access to patient health information, but also improved patient care. In this paper, we describe a surrogate host based mobile healthcare information system which utilized Grid computing for real-time ECG signal processing. The surrogate host provides seamless interface between mobile device and Medical Grid portal. The security extension of GSI (Grid Security Infrastructure) allows mobile users to access Grid portal in a secure and convenient manner. The presented system architecture can be used as a secure enterprise mobile healthcare system for hospital physicians.

  • PDF

Marketing strategy of urinary incontinence equipment in Europe (웰빙용 여성 요실금 치료기의 유럽 마케팅 전략)

  • Lee, Woo-Chun;Park, Roh-Gook
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.1
    • /
    • pp.67-72
    • /
    • 2012
  • This study describes the environment change of an internal and external medical device market to be entered to European market of an urinary incontinence treatment device, is aimed at suggesting a participation plan analyzing urinary incontinence and treatments, and characteristic of new products & European urinary incontinence market. In conclusion, to sell the urinary incontinence treatment device developed as the world's first in European market, the following strategies are needed. First, the strategies domestic firms make family doctors and urologists heighten awareness of the urinary incontinence treatment device developed in Korea through participation of associations and exhibition being held in Europe to increase a market penetration level are needed. Second, it may be necessary to emphasize the fact that this devices are a characterful products and treatments, and cost-effectiveness treatments reducing infection ratio. Third, the domestic production firms of the urinary incontinence treatment device should suggest quality, delivery, and price consistency through looking for ways to lower the price while maintaining the quality in an increasingly competitive market conditions.

  • PDF

Kinematics Analysis of Lumbar Spine during Breathing in Lying Position (누운 자세에서 호흡에 따른 요추분절의 운동학적 분석)

  • Yuk, Goon-Chang;Park, So-Hyun;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.5
    • /
    • pp.15-21
    • /
    • 2011
  • Purpose: The purpose of this study was to describe the influence of respiration on the segmental motion of the lumbar spine in the lying position. Methods: Twelve healthy females without a history of low back pain participated. Lumbosacral lordosis, intervertebral body angles, intervertebral body displacements, and anterior heights of the intervertebral disc of the lumbar spine were measured at inspiration, expiration and forced expiration in the supine and prone positions via fluoroscopy. Results: The results of lumbar kinematic analysis in the supine position according to respiration pattern were as follows. The L4/5 intervertebral body angle was significantly higher at forced expiration than at expiration (p<0.05). The L3/4 anterior height of the intervertebral disc was significantly higher at expiration than at forced inspiration and the L5/S1 anterior height of the intervertebral disc was significantly higher at inspiration than at forced expiration (p<0.05). There were no significant differences in the intervertebral body displacements and lumbosacral lordosis in the supine position (p>0.05). The results of lumbar kinematic analysis in the prone position according to respiration pattern were as follows. The L5/S1 anterior height of the intervertebral disc was significantly higher at inspiration than at forced expiration (p<0.05). However, there was no significant difference in the intervertebral body angle, the intervertebral body displacements, and the lumbosacral lordosis (p>0.05). Conclusion: These findings suggested that respiration can affect the intervertebral body angle and anterior height of the intervertebral disc in some segments. The results from this study serve as a step in the development of guidelines for lumbar kinematic analysis for lumbar breathing training.

Temporal Expression of Interleukin-1${\beta}$ in the Dorsal Root Ganglion in a Rat Model of Lumbar Disc Herniation

  • Kim, Su-Jeong;Gu, Hee-Jin;Cho, Yun-Woo;Park, Hea-Woon;Lee, Joon-Ha;Hwang, Se-Jin;Ahn, Sang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.3
    • /
    • pp.93-98
    • /
    • 2010
  • Purpose: To investigate temporal changes in IL-1${\beta}$ mRNA expression in spinal dorsal horn (DH) and dorsal root ganglion (DRG) in a rat lumbar disc herniation (LDH) model. Methods: Autologous nucleus pulposus, harvested from the tail disc between the second and third coccygeal vertebrae (Co2-3), was implanted next to the left L5 nerve root just proximal to the DRG after partial laminectomy. IL-1${\beta}$ mRNA expression was investigated in DRG and DH in our LDH model. Real-time PCR assays were done using a 7500 Real Time PCR system (Applied Biosystems, USA). Results: Expression of IL-1${\beta}$ in DRG and DH was observed for 30 days postoperatively. Expression of IL-1${\beta}$ mRNA in the ipsilateral DRG of the LDH group gradually increased from 5 to 30 days after surgery. The amount of IL-1${\beta}$ in the contralateral DRG peaked 10 days after surgery and then gradually decreased. However, there was no difference in IL-1${\beta}$ mRNA expression in spinal DH between the LDH group and the sham-operated group. Conclusion: Long-term expression of IL-1${\beta}$ in the LDH model may worsen the chronic pain state. Future studies on inhibition of IL-1${\beta}$ expression in the LDH model will be needed to develop selective treatment strategies for patients with LDH.

Perceptions of Family Care-givers toward Use of Physical Restraints: An Application of Q-methodology (중환자 가족의 신체억제대 사용에 대한 인식: Q방법론적 접근)

  • Yeun, Eun Ja;An, Jeong Hwa;Kim, Jung A;Jeon, Mi Soon
    • Korean Journal of Adult Nursing
    • /
    • v.25 no.3
    • /
    • pp.344-355
    • /
    • 2013
  • Purpose: The purpose of this study was to identify on the perceptions of family care-givers toward use of physical restraints according to their values, beliefs, and perceptions using Q methodology. Methods: Thirty-three family care-givers classified 41 selected Q-statements into 9 points standard. The obtained data were analyzed by using a pc QUANL program. Results: Principal component analysis identified 4types of the perceptions of family care-givers toward the use of physical restraints. Type I is 'Rational accepted', which means that they perceived the restraints are essential therapeutic devices and had cooperative attitude to use of medical staffs' restraints. Type II is 'Sardonic sensibility', which means that they have a negative and a cynical attitude to use of physical restraints. Type III is 'Ambivalent', which means that they have conflicts between rationality and emotion, and type IV is 'Practical claim of a right', which means they insist that patients and their family members must be provided with a detailed explanation regarding the application of physical restraints. Conclusion: The findings of this study suggest that perceptions toward the use of physical restraints among family care-givers should be understood for patients' safety and dignity in medical circumstance. Based on the results, this study will be useful in developing the customized nursing intervention for supporting family care-givers' subjectivity considering the Korean context.

Assessment of Noise Exposure and Hearing Loss Among Workers in Textile Mill (Thamine), Myanmar: A Cross-Sectional Study

  • Zaw, Aung K.;Myat, Aung M.;Thandar, Mya;Htun, Ye M.;Aung, Than H.;Tun, Kyaw M.;Han, Zaw M.
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.199-206
    • /
    • 2020
  • Background: In a wide range of industries, noise-induced hearing loss remains one of the most prevalent occupational problems. This study aimed to assess the noise exposure level and associated factors of hearing loss among textile workers in Yangon Region, Myanmar. Methods: A cross-sectional study was conducted at a Textile mill (Thamine), Yangon Region, from April to December 2018. In total, 226 workers who were randomly selected from 3 weaving sections participated in face-to-face interviews using a structured questionnaire. A digital sound level meter and pure-tone audiometer were used for the assessment of noise exposure level and hearing loss, respectively. Logistic regression analysis was performed to assess the associated factors of hearing loss. Results: In total workers, 66.4% were exposed to ≥85 dB(A) of noise exposure, and the prevalence of hearing loss was 25.7%. Age ≥35 years, below high school education, hearing difficulty, tinnitus, hypertension, > 9 years of service duration in a textile mill were positively associated with hearing loss. After adjusting confounding factors, age ≥35 years (adjusted odds ratio = 6.90, 95% confidence interval = 3.45-13.82) and tinnitus (adjusted odds ratio = 2.88, 95% confidence interval = 1.13-7.37) were persistently associated with hearing loss. Conclusion: Providing occupational hazard education and enforcement of occupational safety regulations should be taken to decrease the noise exposure level. The regular audiometry test should be conducted for assessment of hearing threshold shift. The employer needs to implement a hearing conservation program in workplace when noise exposure reaches or exceeds 85 dB(A) for 8 hours.