• Title/Summary/Keyword: Hospital medical devices

Search Result 303, Processing Time 0.027 seconds

Validation of Electronic Foot Function Index in Patients with Foot and Ankle Disease: A Randomized, Prospective Multicenter Study (족부 족관절 질환 환자에서 전자식 족부 기능 지수의 인증: 임의 배정, 전향적, 다기관 연구)

  • Lee, Dong Yeon;Kim, Yu Mi;Lee, Jun Hyung;Kim, Jin;Kim, Ji-Beom;Kim, Bom Soo;Choi, Gi Won;Seo, Sang Gyo;Kim, Jun Beom;Park, Se-Jin;Kim, Yoon-Chung;Choi, Young Rak;Lee, Dong-Oh;Cho, Jae-Ho;Chun, Dong-Il;Kim, Hyong Nyun;Park, Jae-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.1
    • /
    • pp.24-30
    • /
    • 2019
  • Purpose: To evaluate the efficiency of the electronic foot function index (eFFI) through a prospective, random based, multi-institutional study. Materials and Methods: The study included 227 patients ranging in age from 20 to 79 years, visited for surgery in different 15 institutes, and agreed to volunteer. The patients were assigned randomly into a paper-based evaluated group (n=113) and tablet-based evaluated group (n=114). The evaluation was done on the day of hospital admission and the method was changed on the second day of surgery and re-evaluated. PADAS 2.0 (https://www.proscore.kr) was used as an electronic evaluation program. Results: There were no differences in age and sex in both groups. The intraclass correlation coefficient (ICC) evaluation revealed an eFFI ICC of 0.924, showing that both results were similar. The evaluation time was shorter in the tablet-based group than the paper-based group (paper vs tablet, $3.7{\pm}3.8$ vs $2.3{\pm}1.3minutes$). Thirty-nine patients (17.2%) preferred to use paper and 131 patients (57.7%) preferred the tablet. Fifty-seven patients (25.1%) found both ways to be acceptable. Conclusion: eFFI through tablet devices appears to be more constant than the paper-based program. In addition, it required a shorter amount of time and the patients tended to prefer the tablet-based program. Overall, tablet and cloud system can be beneficial to a clinical study.

The Effect of the Medical Service by Service Instruction of Dental Health Care Worker (치과 의료 종사자의 의료 서비스 교육이 의료 서비스에 미치는 영향)

  • Kim, Chang-Hee;Lee, Ji-Youn;Lee, Hyun-Ook
    • Journal of dental hygiene science
    • /
    • v.1 no.1
    • /
    • pp.53-59
    • /
    • 2001
  • This study was aimed to survey the level of service education in the people engaging in medical services and identify the influence of the education on their job performance. This study was conducted from February 10th, 2000 to March 10th, 2000, centering on Seoul and Kyonggi area. A total of 341 questionnaires were distributed for the survey. The result ware as followings: (1) In a question about the satisfaction over general medical services such as the location of medical institutions, medical equipments and devices, and the attitudes of medical personnel, the group with service education marked 4.07 while the group with no education earned 3.97, showing statistically significant difference(p<.05). (2) In the area of medical institutions image, level of medical services and promotion, the group with service education showed 4.01 while the group with no education gained 3.83, also showing statistically significant difference(p<.05). (3) No statistically meaningful difference was revealed in the area of satisfaction for over all medical services such as the contentment about the medical services being provided, rooms for improvement and the adequacy of the number of medical personnel. The group with education acquired 3.32, with the group with no education 3.34. (4) Satisfaction about the education and awareness about medical services were high in the group of dental hygienists and showed a statistically meaningful difference. (5) The average number of education recorded 1.83 and satisfaction over service education inside the hospital was low, registering 3.24. (6) Teamwork among the personnel in the hospital was 3.70, which is relatively high. The fulfillment over given tasks posted 3.56 and the recommendation for medical institutions was low, recording 3.24. (7) The necessity of medical service education for medical personnel gained 4.40, indicating heightened awareness over the need for service education.

  • PDF

Relationship between shellfish consumption and urinary phthalate metabolites: Korean National Environmental Health Survey (KoNEHS) cycle 3 (2015-2017)

  • Jisoo Kang;Seong-yong Cho;Jinseok Kim;Seongyong Yoon;Jong-min An;Gayoung Kim;Si young Kim
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.2.1-2.15
    • /
    • 2023
  • Background: Phthalates are endocrine disrupting chemicals that are widely used in the production of items of daily life such as in polyvinylchloride plastics, insecticides, and medical devices. This study aimed to determine the association between phthalate exposure and shellfish consumption using data from the Korean National Environmental Health Survey (KoNEHS) cycle 3 (2015-2017), which is a nationally representative survey. Methods: In this study, we analyzed the KoNEHS cycle 3 data of 3,333 (1,526 men and 1,807 women) adults aged more than 19 years. Data related to the variables of sociodemographic factors, health-related behaviors, dietary factors, seafood consumption frequency, and urinary phthalate metabolites concentrations were collected. The concentrations of urinary phthalate metabolites of all the participants were divided into quartiles to define high and low concentration groups based on the 75th percentile concentration. A χ2 test was conducted to analyze the distribution of independent variables. To analyze the relationship between shellfish consumption and phthalate exposure, the odds ratios (ORs) were calculated using logistic regression analysis. Results: Total adults with shellfish consumption frequency of over once a week showed the following adjusted ORs for high concentrations of the following metabolites compared with the group that consumed shellfish once a week or less: 1.43 (95% confidence interval [CI]: 1.01-2.06) for mono-(2-ethyl-5-oxohexyl) phthalate (MEOHP), 1.43 (95% CI: 1.01-2.03) for mono-(2-ethyl-5-carboxypentyl) phthalate (MECPP), 1.57 (95% CI: 1.10-2.24) for ∑di-2-ethylhexyl phthalate (∑DEHP), 2.01 (95% CI: 1.46-2.77) for mono-carboxyoctyl phthalate (MCOP), 1.56 (95% CI: 1.11-2.18) for mono-carboxy-isononly phthalate (MCNP), and 2.57 (95% CI: 1.85-3.56) for mono (3-carboxypropyl) phthalate (MCPP). Conclusions: The concentrations of urinary phthalate metabolites (MEOHP, MECPP, ∑DEHP, MCOP, MCNP, and MCPP) were higher in adults with a higher frequency of shellfish consumption.

Animal Experiment of the Pneumatic Ventrivular Assist Device (공압식 심실 보조기의 동물실험)

  • Park, Seong-Sik;Kim, Sam-hyun;Seo, Pil-won;Choi, Chang-hyu;Lee, Sang-hoon;Lee, Hyuk-soo;Hwang, Seung-ok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

Comparison of pediatric injury patterns before and during the COVID-19 pandemic in Korea: a retrospective study

  • Geom Pil Nam;Woo Sung Choi;Jin-Seong Cho;Yong Su Lim;Jae-Hyug Woo;Jae Ho Jang;Jea Yeon Choi
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.343-353
    • /
    • 2023
  • Purpose: The COVID-19 pandemic led to significant changes in the lifestyle patterns of children and affected the patterns of pediatric injuries. This study analyzed the changing patterns of pediatric injury overall and by age groups, based on the datasets before and during the COVID-19 pandemic. Methods: This study is based on the data of patients who presented with injuries at 23 hospital emergency departments participating in the Emergency Department-based Injury In-depth Surveillance (EDIIS) conducted by the Korea Disease Control and Prevention Agency. The surveillance data was categorized by injury mechanism, location, activity, and severity. We analyzed the injury patterns of pediatric patients aged 0 to 15 years. Subgroup analysis was conducted by age group in children aged 7 to 15 years, 1 to 6 years, and <1 year. Results: When comparing the COVID-19 pandemic period to the pre-COVID-19 period, the total number of pediatric patients with injuries decreased by 38.7%, while the proportions of in-home injuries (57.9% vs. 67.9%), and minor injuries (38.9% vs. 39.7%) increased. In the 7 to 15 years group, bicycle riding injuries (50.9% vs. 65.6%) and personal mobility device injuries (2.4% vs. 4.6%) increased. The 1 to 6 years group also showed an increase in bicycle accident injuries (15.8% vs. 22.4%). In the <1 year group, injuries from falls increased (44.5% vs. 49.9%). Self-harm injuries in the 7 to 15 years group also increased (1.6% vs. 2.8%). Conclusions: During the COVID-19 pandemic period, the overall number of pediatric injuries decreased, while injuries occurring at home and during indoor activities increased. Traffic accidents involving bicycles and personal mobility devices and self-harm injuries increased in the 7 to 15 years group. In the <1 year group, the incidence of falls increased. Medical and societal preparedness is needed so that we might anticipate these changes in the patterns of pediatric injuries during future infectious disease pandemics.

Detecting of Periodic Fasciculations of Avian Muscles Using Magnetic and Other Multimedia Devices

  • Nakajima, Isao;Tanaka, Sachie;Mitsuhashi, Kokuryo;Hata, Jun-ichi;Nakajima, Tomo
    • Journal of Multimedia Information System
    • /
    • v.6 no.4
    • /
    • pp.293-302
    • /
    • 2019
  • In the past, there was a theory that influenza wasn't transmitted directly from birds but was infected to humans via swains. Recently, molecular level research has progressed, and it was confirmed that the avian influenza virus can directly infected to human lung and intestinal epithelial cells. Three pandemicsin the past 100 years were also infected to humans directly from birds. In view of such scientific background, we are developing a method for screening sick birds by monitoring the physiological characteristics of birds in a contactless manner with sensors. Here, the movement of respiratory muscles and abdominal muscles under autonomic innervation was monitored using a magnet and Hall sensor sewn on the thoracic wall, and other multimedia devices. This paper presents and discusses the results of experiments involving continuous periodic noise discovered during flight experiments with a data logger mounted on a Japanese pheasant from 2012 to 2015. A brief summary is given as the below: 1. Magnet and Hall sensor sewn to the left and right chest walls, bipolar electrocardiograms between the thoracic walls, posterior thoracic air sac pressure, angular velocity sensors sewn on the back and hips, and optical reflection of LEDs (blue and green) from the skin of the hips allow observation of periodic vibrations(fasciculations) in the waves. No such analysis has been reported before. 2. These fasciculations are presumed to be derived from muscle to maintain and control air sac pressure. 3. Since each muscle fiber is spatially Gaussian distributed from the sympathetic nerve, the envelope is assumed to plot a Gaussian curve. 4. Since avian trunk muscles contract periodically at all time, we assume that the sympathetic nerve dominates in their control. 5. The technique of sewing a magnet to the thoracic wall and measuring the strength of the magnetic field with a Hall sensor can be applied to screen for early stage of avian influenza, with a sensor attached to the chicken enclosure.

Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology (3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발)

  • Jeong-Wan Kim;Youl-Hun Seoung
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.

Suggestion for Comprehensive Quality Assurance of Medical Linear Accelerator in Korea (국내 선형가속기의 포괄적인 품질관리체계에 대한 제언)

  • Choi, Sang Hyoun;Park, Dong-wook;Kim, Kum Bae;Kim, Dong Wook;Lee, Jaiki;Shin, Dong Oh
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.294-303
    • /
    • 2015
  • American Association of Physicists in Medicine (AAPM) Published Task Group 40 report which includes recommendations for comprehensive quality assurance (QA) for medical linear accelerator in 1994 and TG-142 report for recommendation for QA which includes procedures such as intensity-modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) in 2010. Recently, Nuclear Safety and Security Commission (NSSC) published NSSC notification no. 2015-005 which is "Technological standards for radiation safety of medical field". This notification regulate to establish guidelines for quality assurance which includes organization and job, devices, methods/frequency/tolerances and action levels for QA, and to implement quality assurance in each medical institution. For this reason, all of these facilities using medical machine for patient treatment should establish items, frequencies and tolerances for proper QA for medical treatment machine that use the techniques such as non-IMRT, IMRT and SRS/SBRT, and perform quality assurance. For domestic, however, there are lack of guidelines and reports of Korean Society of Medical Physicists (KSMP) for reference to establish systematic QA report in medical institutes. This report, therefore, suggested comprehensive quality assurance system such as the scheme of quality assurance system, which is considered for domestic conditions, based the notification of NSSC and AAPM TG-142 reports. We think that the quality assurance system suggested for medical linear accelerator also help establishing QA system for another high-precision radiation treatment machines.

Clinical Characteristics of Oncologic Patients with DNR Decision at a Tertiary Hospital (심폐소생술금지 결정 시점에서의 임상적 특성: 일개 종합병원 종양내과 사망한 암환자를 대상으로)

  • Kang, Na Young;Park, Jeong Yun
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.1
    • /
    • pp.26-33
    • /
    • 2016
  • Purpose: This study was conducted to identify clinical characteristics of oncologic patients at a point when they signed their do-not-resuscitate (DNR) orders. Methods: From January through December 2014, we retrospectively analyzed the records of 197 patients who passed away after agreeing to a DNR order in the hemato-oncology department of a tertiary hospital. Results: Of all, 121 patients (61.4%) were male and 76 (38.6%) were female, and their average age was 58.7 years. Ninety-four patients (47.7%) had gastrointestinal cancer. The ECOG performance status at admission was grade 3 in 76 patients (36.5%) and grade 4 in 11 (5.6%). The patients' mean hospital stay was 20 days. The mean duration from the admission to DNR decision was 13 days, and the mean duration from DNR decision to death was seven days. Conclusion: Study results indicate that a decision on signing or refusing a DNR order was made by medical staff mostly based on the opinions of patients' guardians rather than the patients themselves. This suggests that patients' own wishes are not well respected. Thus, it is urgent to establish institutional devices to enhance cancer patients' autonomy regarding DNR and to define an adequate timing for withdrawal of treatments.

Characteristics of Photon Beam through a Handmade Build-Up Modifier as a Substitute of a Bolus (Bolus를 대체하기 위해 자체 제작된 선량상승영역 변환기를 투과한 광자선의 특성)

  • Kim, Sung Joon;Lee, Seoung Jun;Moon, Su Ho;Seol, Ki Ho;Lee, Jeong Eun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.225-232
    • /
    • 2014
  • We evaluated the effect of scatter on a build-up region based on the measured percent depth dose (PDD) of high-energy photon beams that penetrated a handmade build-up modifier (BM) as a substitute of bolus. BM scatter factors ($S_{BM}$) were calculated based on the PDDs of photon beams that penetrated through the BM. The calculated $S_{BM}$ values were normalized to 1 at the square field side (SFS) of 30 mm without a BM. For the largest SFS (200 mm), the SBM values for a 6-MV beam were 1.331, 1.519, 1.598, 1.641, and 1.657 for the corresponding BM thickness values. For a 10-MV beam, the $S_{BM}$ values were 1.384, 1.662, 1.825, 1.913, and 2.001 for the corresponding BM thickness values. The BM yielded 76% of the bolus efficiency. We expect BM to become useful devices for deep-set patient body parts to which it is difficult to apply a bolus.