A Feasibility Study for Application of Single-Chip Solution for Diagnostic Resting ECG (ECG 원칩 솔루션의 진단용 심전계 적용을 위한 타당성 연구)

  • Kang, Bum-Sun;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.86-94
    • /
    • 2015
  • In order for medical devices to be used outside hospital, they have to be not only of small size but also power consumption has to be kept at low level. This study investigates the feasibility of application of ADS1298 ECG single-chip solution developed by Texas Instruments Inc. for use in development of a new platform for diagnostic resting ECG. To prove the feasibility of commercial products based on the ADS1298 chip, the performance of the ADS1298 chip was measured in terms of input impedance, common mode rejection, frequency response, and input dynamic range using the testing method under the suitability criteria of the IEC 60601-2-25 standard. Result of the this study shows that commercialization of the ECG products based on the ADS1298 ECG single-chip solution that satisfies the international standards would be possible, if the manufactures take the filter characteristics into account in building a new platform for diagnostic resting ECG.

Musculoskeletal Ultrasound Findings of Shoulder Pain Patients: A Retrospective Observational Study (근골격계 초음파 진단기기를 활용한 견관절 통증 환자의 초음파 소견: 후향적 관찰 연구)

  • Hyun-Tae Kim;Hye-Jin Park;Yeon-Woo Lee;Sun-Young Park;In Heo;Eui-Hyoung Hwang;Byung-Cheul Shin;Man-Suk Hwang
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.2
    • /
    • pp.77-85
    • /
    • 2023
  • Objectives The aim of this study is to retrospectively evaluate the shoulder lesions in patients experiencing shoulder pain through the use of musculoskeletal ultrasound during Korean medicine intervention treatments. Methods A total of 20 cases were collected, including biceps tendinitis (n=4), calcification (n=3), SASD bursitis (n=4), partial tear (n=2), full-thickness tear (n=1), tendinopathy (n=5), and impingement syndrome (n=1). Musculoskeletal ultrasound was used by Korean medicine doctors to perform real-time scanning and to explain the patient's condition during treatment sessions. Results The use of musculoskeletal ultrasound allowed Korean medicine doctors to perform treatments such as pharmacoacupuncture, acupotomy, and acupuncture more safely and effectively. Patients were able to better understand their conditions through real-time imaging and explanations provided by the doctors. Conclusions Musculoskeletal ultrasound has the potential to enhance the safety and efficacy of Korean medicine intervention treatments for patients with shoulder pain. Institutional or governmental support is needed to further promote the use of medical devices by Korean medicine doctors, ultimately leading to an increase in cases and clinical evidence.

Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems (집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰)

  • Kim, Jun-tae;Kim, Ju-hee;Joo, Kyu-tai;Kim, Kyung-ah;Ryu, Ok-su;Jo, Jae-hyun;Jeong, Jin-Hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.164-177
    • /
    • 2022
  • Medical device usability evaluation refers to the evaluation of medical devices through actual users before the final prototype production is completed. IEC 62366, one of the international safety standards for electronic medical devices, is a standard that must be applied to obtain medical device licenses in major advanced countries such as Europe and the United States. In Korea, through the Ministry of Food and Drug Safety's notice, from January 2021, sequential application by grade has been implemented. In this study, 15 participant specialists were recruited through the Incheon G University Hospital Medical Device Convergence Center for formative evaluation during user suitability evaluation of the focused ultrasound stimulation system being developed by Icleo Co., Ltd., and the test was conducted through joint scenario development. . In the result of task performance, the performance rate was 90.67%, and after the completion of the performance, 86.67% of 'Easy user interface' and 94% of 'Identification/Readability/Understanding of information' questions in the participant survey results analysis by question. The response rate was above average.

Perception of Patient Safety Risk Factors and Performance Level of Safety Care Activities among Hospital Nurses (환자안전 위험요인에 대한 병원간호사의 인식수준과 안전간호활동 수행정도)

  • Son, Young Shin;Lee, Young Whee;Kim, Young Shin;Song, Eun Jeong;Lee, Hye Ryun;Lee, Ju Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.24 no.2
    • /
    • pp.190-200
    • /
    • 2018
  • Purpose: The purpose of this study was to identify the level of perception of safety risk factors and the degree of performance of safety nursing activities in order to develop an education program to improve the safety of patients. Methods: The subjects were 217 nurses from 3 university hospitals in Incheon. Data were collected with structured questionnaires and analyzed using descriptive analysis, t-test, and ANOVA using SPSS 22.0. Results: The level of perception of patient's safety risk factors and safety care activities was 2.93 and 4.68, respectively. Perception of patient safety risk factors which belonging to the risk type of therapeutic devices, equipment, service and infrastructure all scored below average; also in addition, behavior, performance, and violence risk type and work system, information and communication risk type showed relatively low perception levels. Safety nursing activities showed a low level of performance in accurate communication among medical teams, management of fire and disaster, security management, use of restraints, identification of patients, and correct performance of operations and procedures. Conclusion: Based on these results, it is necessary to improve the safety of patients by taking proper management measures along with education.

Design of data integration model between hospitals for healthcare information collection (헬스케어 정보 수집을 위한 병원간 데이터 통합 모델 설계)

  • Jeong, Yoon-Su;Han, Kun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • As IT technology develops recently, medical equipment used in hospitals is demanding high performance. However, since the user visits different hospitals depending on the user's situation, the medical information treated at the hospital is distributed among the hospitals. In this paper, we propose a model to efficiently integrate the health care information of the users stored in the hospital in order to collect the healthcare information of the users who visited the different hospitals. The proposed model synchronizes users' healthcare information collected from personal wearable devices to collect user - centered healthcare information. In addition, the proposed model performs integrity and validity check related to user's healthcare information in a database existing in a cloud environment in order to smoothly share data with the healthcare service center. In particular, the proposed model enables tree - based data processing to smoothly manage healthcare information collected from mobile platforms.

A novel Method for Blood Typing using Acoustic Streaming (음향적 흐름을 이용한 혈액형 분석을 위한 새로운 방법)

  • Choi, Hyunjoo;Jang, Woong Sik;Nam, Jeonghun;Lim, Chae Seung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.250-255
    • /
    • 2018
  • Accurate blood typing is the crucial factor for safe and successful blood transfusion and plays a very important role in organ transplantation and genetic information of forensic medicine. Microfluidic devices have been developed to overcome the limitations of the conventional blood typing methods. In this study, we demonstrate a Lamb wave-based device for simple blood typing in a sample droplet and we propose new indices for quantitative and accurate blood typing. Using Lamb wave-induced acoustic streaming in the droplet, the blood sample and the reagent can be mixed rapidly and red blood cells start to form clumps, which is agglutination. Based on the recorded image and video, the intensity of transmitted light through the sample droplet is evaluated to determine the blood type. Effect of the concentration of suspended red blood cells was evaluated and we found that 10% concentration of suspended red blood cells was suitable to observe the difference between aggregated and non-aggregated samples. Finally, sample with blood type A could be determined using anti-A reagent in our Lamb wave-based device. Our device enables simple and accurate blood typing, which can be applied to resource-limited environments.

Clinical Characteristics of Disability in Patients with Indoor Aire-Related Environmental Intolerance

  • Vuokko, Aki;Karvala, Kirsi;Suojalehto, Hille;Lindholm, Harri;Selinheimo, Sanna;Heinonen-Guzejev, Marja;Leppamaki, Sami;Cederstrom, Sebastian;Hublin, Christer;Tuisku, Katinka;Sainio, Markku
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.362-369
    • /
    • 2019
  • Background: Chronic nonspecific symptoms attributed to indoor nonindustrial work environments are common and may cause disability, but the medical nature of this disability is unclear. The aim was to medically characterize the disability manifested by chronic, recurrent symptoms and restrictions to work participation attributed to low-level indoor pollutants at workplace and whether the condition shares features with idiopathic environmental intolerance. Methods: We investigated 12 patients with indoor aire-related work disability. The examinations included somatic, psychological, and psychiatric evaluations as well as investigations of the autonomic nervous system, cortisol measurements, lung function, and allergy tests. We evaluated well-being, health, disability, insomnia, pain, anxiety, depression, and burnout via questionnaires. Results: The mean symptom history was 10.5 years; for disabling symptoms, 2.7 years. Eleven patients reported reactions triggered mainly by indoor molds, one by fragrances only. Ten reported sensitivity to odorous chemicals, and three, electric devices. Nearly all had co-occurrent somatic and psychiatric diagnoses and signs of pain, insomnia, burnout, and/or elevated sympathetic responses. Avoiding certain environments had led to restrictions in several life areas. On self-assessment scales, disability showed higher severity and anxiety showed lower severity than in physician assessments. Conclusion: No medical cause was found to explain the disability. Findings support that the condition is a form of idiopathic environmental intolerance and belongs to functional somatic syndromes. Instead of endless avoidance, rehabilitation approaches of functional somatic syndromes are applicable.

Bacterial Contamination of Digital Panoramic Dental X-Ray Equipment

  • Lee-Rang Im;Ji-Hyun Min;Ki-Rim Kim
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.343-350
    • /
    • 2023
  • Background: Digital panoramic dental X-ray equipment (PDX) is frequently used by patients and dental workers for diagnosis and examination in dental institutions; however, infection control has not been properly implemented. Therefore, in this study, we aimed to systematically review the potential risk of cross-infection in the dental environment by investigating the contamination level of general aerobic bacteria and Staphylococcus aureus, which are important in hospital infections, in PDX areas that people mainly contact. Methods: This survey was conducted from March to May 2023 and covered one general hospital, three dental hospitals, and nine dental clinics equipped with PDX. Bacteria samples were collected from the left-handle, right-handle, forehead support, and head side support as the patient's contact areas, as well as the X-ray exposure switch and left-click mouse button as the dental hygienist's contact areas of the PDX. The collected bacteria were spread on Petrifilm, and colonies formed after 48 hours of culture were counted. Results: General aerobic bacteria and S. aureus were detected in all areas investigated. Significant differences in bacterial counts between different regions of the PDX were observed in both groups (p<0.001). The detection rates of general aerobic bacteria (p<0.001) and S. aureus (p<0.001) were significantly higher in the contact areas of patients than those of dental hygienists. A positive correlation was observed between the forehead and the temple region in terms of general aerobic bacteria and S. aureus detection (r=1) (p<0.01). Conclusion: Taken together, the presence of many bacteria, including S. aureus, detected in PDX indicates that PDX has a potential cross-infection risk. Our results therefore highlight the need for the development of appropriate disinfection protocols for reusable medical devices such as PDX and periodic infection prevention training for hospital-related workers, including dental hygienists.

Efficacy and Usability of Patient Isolation Transport Module for CBRN Disaster : A Manikin Simulation Study (특수재난 대응 환자 격리 이송 장비의 효율성 및 편의성 평가: 마네킹시뮬레이션 연구)

  • Kim, Ki-Hong;Hong, Ki-Jeong;Haam, Seung-Hee;Choi, Jin-Woo
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • In Chemical, Biological, Radiological and Nuclear (CBRN) disaster, integrated and optimized equipment package including stretcher, isolation unit, patient monitoring and treatment equipment is essential to achieve proper treatment and prevent secondary contamination. The purpose of this study was to evaluate the efficiency and ease of use of integrated CBRN disaster equipment package for disaster medical response. This study was a randomized crossover study using a manikin simulation for emergency medical technitian (EMT). All participants used the existing devices and prototype of integrated CBRN disaster equipment package alternately. Efficiency was measured by time from vital sign change to detection or treatment application. Ease was use was measured by questionnaires for each patient monitor, stretcher care and isolation unit. 12 EMTs were enrolled. hypoxia-detection time of integrated equipment group was significantly shorter than existing equipment group (4.9 s (3.8-3.9) vs 3.5 s (2.5-3.9), p < 0.05). There was decreasing tendency of ECG change detection and facial mask oxygen supply but no statistical significance was observed. Overall satisfaction of patient monitoring device in integrated equipment group was significantly higher than existing devices (4(3.5-5) vs 3(3-3), p < 0.05). The use of integrated CBRN disaster equipment package shortened the hypoxia detection time and improved usability of vital sign monitor compared to existing devices.

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.