DOI QR코드

DOI QR Code

Bacterial Contamination of Digital Panoramic Dental X-Ray Equipment

  • Lee-Rang Im (Department of Dental Hygiene, Kyungpook National University) ;
  • Ji-Hyun Min (Department of Dental Hygiene, College of Health and Medical Health Sciences, Cheongju University) ;
  • Ki-Rim Kim (Department of Dental Hygiene, Kyungpook National University)
  • 투고 : 2023.11.24
  • 심사 : 2023.12.12
  • 발행 : 2023.12.31

초록

Background: Digital panoramic dental X-ray equipment (PDX) is frequently used by patients and dental workers for diagnosis and examination in dental institutions; however, infection control has not been properly implemented. Therefore, in this study, we aimed to systematically review the potential risk of cross-infection in the dental environment by investigating the contamination level of general aerobic bacteria and Staphylococcus aureus, which are important in hospital infections, in PDX areas that people mainly contact. Methods: This survey was conducted from March to May 2023 and covered one general hospital, three dental hospitals, and nine dental clinics equipped with PDX. Bacteria samples were collected from the left-handle, right-handle, forehead support, and head side support as the patient's contact areas, as well as the X-ray exposure switch and left-click mouse button as the dental hygienist's contact areas of the PDX. The collected bacteria were spread on Petrifilm, and colonies formed after 48 hours of culture were counted. Results: General aerobic bacteria and S. aureus were detected in all areas investigated. Significant differences in bacterial counts between different regions of the PDX were observed in both groups (p<0.001). The detection rates of general aerobic bacteria (p<0.001) and S. aureus (p<0.001) were significantly higher in the contact areas of patients than those of dental hygienists. A positive correlation was observed between the forehead and the temple region in terms of general aerobic bacteria and S. aureus detection (r=1) (p<0.01). Conclusion: Taken together, the presence of many bacteria, including S. aureus, detected in PDX indicates that PDX has a potential cross-infection risk. Our results therefore highlight the need for the development of appropriate disinfection protocols for reusable medical devices such as PDX and periodic infection prevention training for hospital-related workers, including dental hygienists.

키워드

참고문헌

  1. Feingold DS: Hospital-acquired infections. N Engl J Med 283: 1384-1391, 1970. https://doi.org/10.1056/NEJM197012172832507
  2. Haque M, Sartelli M, McKimm J, Abu Bakar M: Health care-associated infections - an overview. Infect Drug Resist 11: 2321-2333, 2018. https://doi.org/10.2147/IDR.S177247
  3. Kim B: Basic bacteriology for infection control. Korean J Healthc Assoc Infect Control Prev 25: 79-85, 2020. https://doi.org/10.14192/kjicp.2020.25.2.79
  4. Tong SY, Davis JS, Eichenberger E, Holland TL, Fowler VG Jr: Staphylococcus aureus infections: epidemiology, pathophysiology, clinical manifestations, and management. Clin Microbiol Rev 28: 603-661, 2015. https://doi.org/10.1128/CMR.00134-14
  5. Giulieri SG, Tong SYC, Williamson DA: Using genomics to understand meticillin- and vancomycin-resistant Staphylococcus aureus infections. Microb Genom 6: e000324, 2020. https://doi.org/10.1099/mgen.0.000324
  6. Antimicrobial Resistance Collaborators: Global burden of bacterial antimicrobial resistance in 2019: a systematic analysis. Lancet 399: 629-655, 2022. Erratum in: Lancet 400: 1102, 2022. https://doi.org/10.1016/S0140-6736(21)02653-2
  7. World Health Organization (WHO): WHO Director-General's opening remarks at the media briefing on COVID-19 - 11 March 2020. Retrieved November 11, 2023, from https://www.who.int/director-general/speeches/detail/who-directorgeneral-s-opening-remarks-at-the-media-briefing-on-covid19---11-march-2020
  8. Sharma A, Ahmad Farouk I, Lal SK: COVID-19: a review on the novel coronavirus disease evolution, transmission, detection, control and prevention. Viruses 13: 202, 2021. https://doi.org/10.3390/v13020202
  9. Kang S, Kim Y, Kim J: An analysis of the policy participation of field response nurses in South Korea: COVID-19 response guidelines and the infectious disease act revision. J Nurs Scholarsh 55: 202-214, 2023. https://doi.org/10.1111/jnu.12850
  10. Kalin unuvar G, Doganay M, Alp E: Current infection prevention and control strategies of COVID-19 in hospitals. Turk J Med Sci 51: 3215-3220, 2021. https://doi.org/10.3906/sag-2106-156
  11. Lynch JB, Davitkov P, Anderson DJ, et al.: Infectious Diseases Society of America guidelines on infection prevention for health care personnel caring for patients with suspected or known COVID-19. Clin Infect Dis 2020. [Epub ahead of print] https://doi.org/10.1093/cid/ciaa1063
  12. Sommerstein R, Fux CA, Vuichard-Gysin D, et al.: Risk of SARS-CoV-2 transmission by aerosols, the rational use of masks, and protection of healthcare workers from COVID-19. Antimicrob Resist Infect Control 9: 100, 2020. https://doi.org/10.1186/s13756-020-00763-0
  13. Choi SE, Simon L, Basu S, Barrow JR: Changes in dental care use patterns due to COVID-19 among insured patients in the United States. J Am Dent Assoc 152: 1033-1043.e3, 2021. https://doi.org/10.1016/j.adaj.2021.07.002
  14. Rushton VE, Horner K: The use of panoramic radiology in dental practice. J Dent 24: 185-201, 1996. https://doi.org/10.1016/0300-5712(95)00055-0
  15. Yoon HY, Lee SY: The microbial contamination and effective control method of dental unit water system. J Dent Hyg Sci 15: 383-392, 2015. https://doi.org/10.17135/jdhs.2015.15.4.383
  16. Zemouri C, Volgenant CMC, Buijs MJ, et al.: Dental aerosols: microbial composition and spatial distribution. J Oral Microbiol 12: 1762040, 2020. https://doi.org/10.1080/20002297.2020.1762040
  17. Lee YA, Jo MJ, Bae JY, Park HS: A study on practice of infection control among dental staffs in dental office. J Dent Hyg Sci 7: 263-269,
  18. Mieth L, Mayer MM, Hoffmann A, Buchner A, Bell R: Do they really wash their hands? Prevalence estimates for personal hygiene behaviour during the COVID-19 pandemic based on indirect questions. BMC Public Health 21: 12, 2021. https://doi.org/10.1186/s12889-020-10109-5
  19. Poppe B, Looe HK, Pfaffenberger A, et al.: Dose-area product measurements in panoramic dental radiology. Radiat Prot Dosimetry 123: 131-134, 2007. https://doi.org/10.1093/rpd/ncl090
  20. Gumru B, Tarcin B, Idman E: Cross-contamination and infection control in intraoral digital imaging: a comprehensive review. Oral Radiol 37: 180-188, 2021. https://doi.org/10.1007/s11282-020-00452-z
  21. Malta CP, Damasceno NN, Ribeiro RA, Silva CS, Devito KL: Microbiological contamination in digital radiography: evaluation at the radiology clinic of an educational institution. Acta Odontol Latinoam 29: 239-247, 2016.
  22. Huijsmans-Evers AG: Results of routine tests for the detection of dispersers of Staphylococcus aureus. Arch Chir Neerl 30: 141-150, 1978.
  23. Lee MS, Han HS, Jung JS: Identification of bacterial strains adhered to human scalp hair and antimicrobial susceptibility. Korean J Microbiol 41: 47-52, 2005.
  24. Kim JG, Park JY, Kim JS: Changes of microbial load on the hands of food preparers. J Food Hyg Saf 26: 154-159, 2011.
  25. Cheung GYC, Bae JS, Otto M: Pathogenicity and virulence of Staphylococcus aureus. Virulence 12: 547-569, 2021. https://doi.org/10.1080/21505594.2021.1878688