• Title/Summary/Keyword: Horizontal coefficient of permeability

Search Result 34, Processing Time 0.025 seconds

Heat Transfer and Pressure Drop Characteristics of a Horizontal Channel Filled with Porous Media (다공성매질을 삽입한 수평채널의 열전달 및 압력강하 특성)

  • Son, Young-Seok;Shin, Jee-Young;Cho, Young-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.244-251
    • /
    • 2009
  • Porous media have especially large surface area per volume, which contain complex fluid passage. If porous media can be applied to cool a CPU or an electronic device with large heat dissipation, it could result in heat transfer enhancement due to the enlargement of the heat transfer area and the flow disturbance. This study is aimed to identify the heat transfer and pressure drop characteristics of high-porosity metal foams in a horizontal channel. Experiment is performed with the various heat flux, velocity and pore density conditions. Permeabilities, which is deduced from Non-Darcy flow model, become lower with increasing pore density. Nusselt number also decreases with higher pore density. High pore density with same porosity case shows higher pressure loss due to the increase of surface area per unit volume. The fiction factor decreases rapidly with increase of Reynolds number in Darcy flow region. However, it converges to a constant value of the Ergun coefficient in Non-Darcy flow region.

An Experimental Study on the Evaluation of Smear Effect Considering In-situ Conditions (현장여건을 고려한 스미어 영향 평가에 관한 실험적 연구)

  • Park, Yeong-Mog
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.85-94
    • /
    • 2012
  • Evaluation of the smear effect caused by mandrel penetration into soft ground for a vertical drain installation is very important to predict the consolidation time of soft ground improvement. 30 kinds of laboratory model tests considering in situ conditions were conducted to investigate the formation of a smear zone and the decrease of coefficient of permeability in the disturbed zone. Three types(C(clay):M(silt)=1:1, 0.5:0.5, and 0:1) of reconstituted samples were used for 3 dimensional smear zone test. An experimental study was performed focusing on length of mandrel penetration, mandrel shape and size, earth pressure, and ground condition(unit weight and grain size distributions). Laboratory test results show that the length of mandrel penetration is the most critical factor for the formation of smear zone. As a result, the ratio between diameter of the smear zone($d_s$) and that of mandrel($d_m$) at field using long mandrel becomes larger than conventional $d_s/d_m$. The ratio between $d_s$ and $d_m$ ranges from 1.89 and 2.48 with the sample at C:M=1:0. It was also found that the $d_s/d_m$ value with the round shape of the mandrel is smaller than that of diamond one. The value of $d_s/d_m$ decreased with larger mandrel size, lower unit weight, and higher earth pressure. However, higher silt content led to increase of $d_s/d_m$. The ratio between coefficient of horizontal permeability in the smear zone($k_{hs}$) and that of undisturbed zone($k_{ho}$) ranged from 0.70 to 0.85. The test results imply that factors and values affecting $k_{hs}/k_{ho}$ show similar tendency with $d_s/d_m$.

Seepage Characteristics under Concrete Dam (콘크리트댐 하부에서의 침투특성)

  • Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2773-2778
    • /
    • 2012
  • Formulation of finite difference method for analyzing seepage under concrete dam was carried out in order to find out characteristics of flow net. For the situation without curtain, slope of equipotential line of nonhomogeneous soil is greater in the region which has higher value of coefficient of permeability. By comparing analysis results between the situations with locating curtain at the center portion and left end, velocity of flow along with the face of the right hand side of the curtain for the situation with left end curtain is lower than that for the situation with center curtain. Considering flow in the region of the right of the curtain, streamline for the situation with left curtain gets horizontal relatively.

Investigation on the Field Compaction for Embankment of Fill Dam (휠댐성토의 현장다짐에 관한 연구)

  • 최진규;김문기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.25 no.4
    • /
    • pp.69-79
    • /
    • 1983
  • The objective of this study is to analyze the present situation of compaction equipment used in the earth fill dam construction, and the compaction effects of varions types of equipment on core and pervious zones of the fill dam. The results obtained are summarized as follows; 1. Banking materials mostly used for the core zone were soils classified as CL, SC and ML, while those classified as SM, ML and SC were predominant for the pervious zone. 2. Equipments used practically in the real fields were considerably different from those specified in the designs. 3. It was found that the relationship between optimum water content and maximum dry density for both core and pervious materials showed to be linear, ranging from 10% to 25% water content. That is, ${\gamma}$dmax (core) = 2.2555-0.0284 Wopt ${\gamma}$dmax(pervious) =2.239-0.028 Wopt 4. The generalized compaction guides for all kinds of equipment and soil types consi- dered in this study may be recommended as N=8-10 T=2Ocm, N=10-12 T=3Ocm for core zone(98%) and N=6-8 T=2Ocm, N=8-10 T=3Ocm for pervious zone (95%). 5. The coefficient of permeability in the field tests showed abont 10 times as high as the laboratory test value. This large deviation, however, was due to the horizontal permeation and considered not to be significant in the light of the satisfactory compaction ratio in the field compac- tion.

  • PDF

Numerical analysis of vertical drains accelerated consolidation considering combined soil disturbance and visco-plastic behaviour

  • Azari, Babak;Fatahi, Behzad;Khabbaz, Hadi
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.187-220
    • /
    • 2015
  • Soil disturbance induced by installation of mandrel driven vertical drains decreases the in situ horizontal hydraulic conductivity of the soil in the vicinity of the drains, decelerating the consolidation rate. According to available literature, several different profiles for the hydraulic conductivity variation with the radial distance from the vertical drain, influencing the excess pore water pressure dissipation rate, have been identified. In addition, it is well known that the visco-plastic properties of the soil also influence the excess pore water pressure dissipation rate and consequently the settlement rate. In this study, a numerical solution adopting an elastic visco-plastic model with nonlinear creep function incorporated in the consolidation equations has been developed to investigate the effects of disturbed zone properties on the time dependent behaviour of soft soil deposits improved with vertical drains and preloading. The employed elastic visco-plastic model is based on the framework of the modified Cam-Clay model capturing soil creep during excess pore water pressure dissipation. Besides, nonlinear variations of creep coefficient with stress and time and permeability variations during the consolidation process are considered. The predicted results have been compared with V$\ddot{a}$sby test fill measurements. According to the results, different variations of the hydraulic conductivity profile in the disturbed zone result in varying excess pore water pressure dissipation rate and consequently varying the effective vertical stresses in the soil profile. Thus, the creep coefficient and the creep strain limit are notably influenced resulting in significant changes in the predicted settlement rate.

Engineering Characteristics of Sam Cheok Organic Soil (삼척 유기질토의 공학적 특성)

  • Kim, Sang-Gyu;Choe, In-Geol;Park, Yeong-Mok
    • Geotechnical Engineering
    • /
    • v.12 no.1
    • /
    • pp.21-34
    • /
    • 1996
  • This paper presents the engineering characteristics of the Samcheok organic soil which contains a large portion of organic matter and high natural water content. A series of lab tests shows that the measured liquid limit is quite different depending on preparing methods of specimens. The values tested with natural condition are higher up to 4 times than thole of the oven dry specimen. It is shown that the organic soils fail at large strain and do not show peak stress in the stress strain relationships. Also strength increase ratios, which are measured 0.43 to 0.65 in this tests, are significantly higher than those of the soft clay without organic matter. The consolidation tests indicate that the verti'cal and horizontal Permeabilities are almost the same. For the remolded samples is reduced from 112 to 116 of the vertical permeability An increase of organic matter or water content of the organic soils results in an increase of the coefficient of secondary consolidation. The increase rate is slow below 15 percents of the organic contents while the rate becomes higher above the value.

  • PDF

A Study on the Effect of Improving Permeability by Injecting a Soil Remediation Agent in the In-situ Remediation Method Using Plasma Blasting, Pneumatic Fracturing, and Vacuum Suction Method (플라즈마 블라스팅, 공압파쇄, 진공추출이 활용된 지중 토양정화공법의 정화제 주입에 따른 투수성 개선 연구)

  • Geun-Chun Lee;Jae-Yong Song;Cha-Won Kang;Hyun-Shic Jang;Bo-An Jang;Yu-Chul Park
    • The Journal of Engineering Geology
    • /
    • v.33 no.3
    • /
    • pp.371-388
    • /
    • 2023
  • A stratum with a complex composition and a distributed low-permeability soil layer is difficult to remediate quickly because the soil remediation does not proceed easily. For efficient purification, the permeability should be improved and the soil remediation agent (H2O2) should be injected into the contaminated section to make sufficient contact with the TPH (Total petroleum hydrocarbons). This study analyzed a method for crack formation and effective delivery of the soil remediation agent based on pneumatic fracturing, plasma blasting, and vacuum suction (the PPV method) and compared its improvement effect relative to chemical oxidation. A demonstration test confirmed the effective delivery of the soil remediation agent to a site contaminated with TPH. The injection amount and injection time were monitored to calculate the delivery characteristics and the range of influence, and electrical resistivity surveying qualitatively confirmed changes in the underground environment. Permeability tests also evaluated and compared the permeability changes for each method. The amount of soil remediation agent injected was increased by about 4.74 to 7.48 times in the experimental group (PPV method) compared with the control group (chemical oxidation); the PPV method allowed injection rates per unit time (L/min) about 5.00 to 7.54 times quicker than the control method. Electrical resistivity measurements assessed that in the PPV method, the diffusion of H2O22 and other fluids to the surface soil layer reduced the low resistivity change ratio: the horizontal change ratio between the injection well and the extraction well decreased the resistivity by about 1.12 to 2.38 times. Quantitative evaluation of hydraulic conductivity at the end of the test found that the control group had 21.1% of the original hydraulic conductivity and the experimental group retained 81.3% of the initial value, close to the initial permeability coefficient. Calculated radii of influence based on the survey results showed that the results of the PPV method were improved by 220% on average compared with those of the control group.

A Behavior Ana1ysis of Clayey Foundation Improved with Pack Drain (Pack-Drain으로 개량된 점토지반의 거동해석)

  • 오재화;남기현;이문수;허재은;김영남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.1
    • /
    • pp.116-127
    • /
    • 1996
  • This paper dealt with FEM analysis of foundation improved with pack drain. The theory on pack drain was scrutinized and observed values in the field were compared with numerical results. Work site of Kwangyang container pier was selected as a ease study in which measurement of settlement and pore water pressure was accurately carried out. Biot's consolidation equation was selected as governing One, coupled with modified Camclay model as constitutive one. Christian and Boehmer's numerical technique was adopted. Behavior of foundation with pack drain is not simple but very complicated. Discontinuity resulted from rigidity difference between adjacent materials, smear effect and complicated boundary conditions should be considered in the behavior analysis of foundation behavior. The results of numerical analysis were influenced by smear zone. In relevant to this effect, finite element analysis was carried out using the reduced horizontal coefficient of permeability in the smear zone; The numerical results were compared with observed values in surface settlement. including pore water pressure. However only lateral di5plaoement by numerical ana1Ysis was shown since its measurement was not performed in the field. The predication of settlement to be developed later can be effectively employed for the obtimization of construction. The predication of residual settlement using the data measured in the field was made by Hoshino, Asaoka and hyperbolic method. Among them, the hyperbolic method proved best one. Settlements accorded well between numsrical and observed values while pore pressure showed a slight difference. Lateral displacement showed largest values at constant distance from ground surface. The validation of foundation analysis improved with pack drain by computer program employed in this study selecting modified Cam-clay model was satisfactorily secured.

  • PDF

Assessment on Consolidation Material Function and Initial Stress for Soft Ground by Hydraulic Fill the at Southern Coast of Korea (남해안 준설매립 연약지반에 대한 압밀 물질함수 및 초기응력 산정)

  • Jeon, Je Sung;Koo, Ja Kap
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.136-145
    • /
    • 2011
  • For a massive project related to building national industrial complexes on a soft ground applied to PVD after dredging and hydraulic fill, laboratory tests were carried out using undisturbed sample taken from various depth. Piezocone penetration and dissipation tests were carried out to assess horizontal coefficient of consolidation and initial stress in field. The ground consists of upper dredged fill and lower original clay layer having both similar marine clays. It should be, however, considered as multi-layered soft ground having different initial void ratio, initial water content, initial effective stress, and permeability and compressibility with directions. To assess initial stress of those soft layers in which have different stress history related to consolidation, CPTu test results, especially excess pore water pressure, were analyzed. It allows to find out distribution of excess pore water pressure and initial stress inner original clay layer.

A Study on the Variation of Groundwater Level in the Han River Estuary (The Effect of the Removing of a Weir) (한강 하구역에서의 지하수위 변화에 관한 연구(수중보 철거로 인한 영향))

  • Kim, Sang-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.6
    • /
    • pp.589-601
    • /
    • 2008
  • The variation of groundwater level near the Shingok weir has been analyzed. To consider the soil inhomogeneity, coefficient of effective permeability was computed to be 0.313 m/day in the horizontal direction, and 0.0423 m/day in vertical direction. Anisotropic ratio is 7.19. The river water level drawdown (caused by the removing of the weir) causes the groundwater level drawdown, and 3 months are required for the new steady condition. and groundwater flows from Han river toward Gulpo stream before the removing of the weir, but when the weir removed, the flow direction changes. The groundwater level falls maximum 30 cm in the areas under the influence of Han river, but, in the areas near Kulpo stream, groundwater level falls about 10 cm. The amount of groundwater use in the study area was investigated to be $52m^3/day$ and in this condition, groundwater level falls maximum 1m (before or after the removing of Shingok weir). therefore, the variation of groundwater level caused by the removing of Shingok weir is less than that caused by the usual use of groundwater.