Abstract
This paper presents the engineering characteristics of the Samcheok organic soil which contains a large portion of organic matter and high natural water content. A series of lab tests shows that the measured liquid limit is quite different depending on preparing methods of specimens. The values tested with natural condition are higher up to 4 times than thole of the oven dry specimen. It is shown that the organic soils fail at large strain and do not show peak stress in the stress strain relationships. Also strength increase ratios, which are measured 0.43 to 0.65 in this tests, are significantly higher than those of the soft clay without organic matter. The consolidation tests indicate that the verti'cal and horizontal Permeabilities are almost the same. For the remolded samples is reduced from 112 to 116 of the vertical permeability An increase of organic matter or water content of the organic soils results in an increase of the coefficient of secondary consolidation. The increase rate is slow below 15 percents of the organic contents while the rate becomes higher above the value.
이 논문은 일련의 실내시험을 통해 얻어진 삼척 유기질토의 공학적 특성을 제시한 것이다. 액성한계는 시료의 조제방법에 따라 그 값이 현저히 달라진다는 사실을 알게 되었는데 자연상태로 시험한 값이 노건조시켜 얻어진 값보다 1.5내지 4배나 컸다. 유기질토의 응력변형특성은 변형의 증가에 따라 응력이 점진적으로 증가하는 경향을 보였다. 즉 변형율 20%의 강도가 한국산업규격에 규정된 변형을 15%의 강도보다 더 크다는 것을 알 수 있었다. 또한 유기질토의 강도증가율(0.43~0.65)은 점토에 비해 현저히 크다는 사실도 알 수 있었다. 압밀시험 결과 연직 및 수평방향의 투수계수는 거의 같으나 교란시에는 연직방향의 1/2~1/6로 감소된다는 사실도 알게 되었다. 또한 2차 압밀계수는 유기물함량과 함수비가 많을수록 커지며 유기물함량 15%를 기점으로 하여 그 이하에서는 변화폭이 완만하나 그 이상에서는 큰 변화폭을 보인다.