20db 정착길이를 가지는 SD700 갈고리철근과 확대머리철근의 정착성능 실험 (Anchorage performance tests of SD700 hooked bar and headed bar with a anchorage length of 20db)

  • 김호영;심혜정
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.21-27
    • /
    • 2018
  • With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.

외측 보-기둥 접합부의 정착 상태에 관한 훅크철근의 영향 (Effects of the Number of Hooked Bars on Anchorage Conditions at Exterior Joints)

  • 최기봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제1권2호
    • /
    • pp.151-156
    • /
    • 1997
  • An experimental study was performed on the pull-out behavior of 90-deg standard hooks from exterior beam-column connections. The effects of the number of hooked bars of joint area were investigated. Under the pull-out action of hooked bars, the damage and cracking of joint area tends to be more extensive as the number of hooks pulling out from a joint increases. The pull-out strength and post-peak ductility of hooked bar are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at exterior joints.

  • PDF

콘크리트 강도별 매입 철근의 유형별 부착력 측정실험 (An Experimental Study on Bonding Capacity by Concrete Strength and Type of Re-bar Anchor)

  • 조성열;손기상
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.40-46
    • /
    • 2015
  • Many construction equipment or supporting structure should be installed in a field without appropriate anchorage to cause a collapse of those. Anchor length, anchor diameter, hooked or non hooked will be made and tested in the study. This one will be analyzed and compared with the previous study in order to find out some difference, strength by strength, based on this study. Embedded re-bar and the resistant capacity against pulled out force of re bar have been tested and analyzed by concrete design strength and rebar diameter in the study. 21Mpa and 24MPa compressive strength which are used in construction practice have been applied as variables. Those rebars are composed of D13, D16. D22 which are mostly used at construction sites. The followings are summarized as conclusions.1) ductility is not increased as rebar diameter becomes larger under the condition of non-hooked anchorage.2) those are two times of displacement difference between small diameter of rebar and large one with hooked anchorage of rebar while being 1/10 times difference with non-hooked condition but, only 10% difference of maximum load are shown, not conspicuously between hooked and non-hooked condition.3) displacement related to ductility can be three(3) times decreased if only concrete compressive strength and rebar diameter become larger with heavy support weight.

Effects of Steel Fiber Reinforcement and the Number of Hooked Bars at R/C Exterior Joints

  • Choi, Ki-Bong
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.181-189
    • /
    • 1999
  • An experimental study was performed on the Pull-out behavior of 90-deg standard hooks from the exterior beam-column connections. the effects of the number of hooked bars and fiber reinforcement of the joint area were investigated with the following conclusions : (1) Under the pull-out action of hooked bars. the damage and cracking of joint area the number of hooks pulling out from a joint increases; (2) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by the pull-out of hooked bars; (3) The pull-out strength and post-peak ductility of hooked bars are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at the exterior joints; and (4) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers . The application of steel fibers to the exterior joints is an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in the beam-column connections.

  • PDF

Gr.80 확대머리철근의 원전구조물 적용을 위한 ACI 349 코드개정에 관한 연구 (ACI 349 Code Change to Use the Gr.80 Headed Deformed Bars in Nuclear Power Plant Structures)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.200-201
    • /
    • 2017
  • Generally, a lot of reinforcements are used in nuclear power plant concrete structures, and it may cause several potential problems when concrete is poured. Because of the congestion caused by hooked bars, embedded materials, and other reinforcements, it is too difficult to pour concrete into structural member joint area. The purpose of this study is to change ACI 349 Code for using the large-size(57mm) and high-strength(Gr.80) headed deformed bars instead of standard hooked bars in nuclear power plant concrete structures in order to solve the congestion problems.

  • PDF

Behaviour of fiber reinforced concrete beams with spliced tension steel reinforcement

  • Safan, Mohamed A.
    • Structural Engineering and Mechanics
    • /
    • 제43권5호
    • /
    • pp.623-636
    • /
    • 2012
  • The aim of the current work is to describe the flexural behaviour of simply supported concrete beams with tension reinforcement spliced at mid-span. The parameters included in the study were the type of the concrete, the splice length and the configuration of the hooked splice. Fifteen beams were cast using an ordinary concrete mix and two fiber reinforced concrete mixes incorporating steel and polypropylene fibers. Each concrete mix was used to cast five beams with continuous, spliced and hooked spliced tension steel bars. A test beam was reinforced on the tension side with two 12 mm bars and the splice length was 20 and 40 times the bar diameter. The hooked bars were spliced along 20 times the bar diameter and provided with 45-degree and 90-degree hooks. The test results in terms of cracking and ultimate loads, cracking patterns, ductility, and failure modes are reported. The results demonstrated the consequences due to short splices and the improvement in the structural behaviour due to the use of hooks and the confinement provided by the steel and polypropylene fibers.

콘크리트 구조체 매입 철근의 직경 및 유형별 앵커력 측정실험 연구 (An Experimental Study on the Anchorage Capacity by Diameter and Anchor Type of Re-bar)

  • 조성열;손기상
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.67-73
    • /
    • 2014
  • Construction equipment such as tower crane should be installed in a field without appropriate anchorage to cause a collapse of crane. The anchorage capacity can be varied with Anchor length, concrete strength, anchor diameter, hooked or non hooked these variables will be made and tested in the study. It is shown what anchorage capacity will be more effective case by case. Hooked and non-hooked rebar anchor concrete weight with dia 22mm rebar are shown with initial displacement at 170~220KN of hooked case and 200~210KN of non-hooked one which are linearly increased, without any ductility behavior with almost brittleness. Three(3) same test pieces are almost similarly behaviored without relation to hooked or non-hooked cases. It is found out that the bigger diameter of rebar becomes, the more resistant capacity could be made, but conversely ductility against sudden collapse similar to brittleness becomes the more insufficient. It is also found out that dia 16mm rebar could be more effectively applied to heavy support weight at construction sites.

지지대 및 제결볼트를 이용한 프리캐스트 콘크리트 골조구조의 보 하단 철근 정착공법 개발 (Mechanical Bar Anchorage of the PC Beam in Beam-Column Joint Using Plates and Bolts)

  • 유영찬;최근도;김긍환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.539-544
    • /
    • 2000
  • The purpose of this study is to develop the mechanical anchorage, namely MAB-BOP (Mechanical Anchorage of 90$^{\circ}$ Hooked Bars with BOlt nad Plate) of the beam-column joint in precast concrete framed structures. Six specimens simulating typical interior beam-column joints were tested to investigate the mechanical characteristics of MAB-BOP. Of primary interest was the measurement of the slip of the anchored bar. Th load-slip curve obtained from this test were used to compare the mechanical performances of the different anchoring methods. Based on the test results, it was found that MAB-BOP showed sufficient anchoring strength capacity compared to 90$^{\circ}$ hooked bar method. So, MAB-BOP can be used as the anchoring methods of the reinforcing bars in PC beam-column joint.

  • PDF

고강도철근(550MPa)의 원전구조물 적용을 위한 표준갈고리 정착설계 (Development Length of High-Strength Standard Hooked Bars (550MPa) in Nuclear Power Plant Structures)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.99-100
    • /
    • 2018
  • Because of the congestion problems, the high-strength reinforcements are expected to be used in nuclear power plant structures in the near future. According to ACI 349-13, it is permitted to use the high-strength(550MPa) hooked bars in design of development length, but there is no special equation for high-strength bars. In order to reflect the anchorage capacity and behavior properties of high-strength bars with large-diameter(43 & 57mm), it is necessary to develope the new development length equation for large-size and high-strength bars.

  • PDF

보-기둥 접합부에 정착된 550 MPa 43 mm 갈고리철근의 거동 (Behavior of 550MPa 43mm Hooked Bars Embedded in Beam-Column Joints)

  • 배민서;천성철;김문길
    • 콘크리트학회논문집
    • /
    • 제28권5호
    • /
    • pp.611-620
    • /
    • 2016
  • 철근항복강도가 420 MPa만 사용되는 원자력발전소는 대구경 철근이 과밀 배근되어 정밀시공이 어렵고 콘크리트구조물의 품질저하가 우려된다. 과밀배근 해소를 위해 항복강도 550 MPa 철근의 사용이 필요하다. 이 연구에서는 550 MPa 고강도철근의 실용화를 위해 요구되는 여러 검토 항목 중, 철근과 콘크리트 일체 거동을 위해 필요한 43 mm 갈고리철근의 정착거동을 실험적으로 평가하였다. 실험체 모두 목표했던 측면파열파괴가 발생하여, 최대하중에서 측면 피복두께가 급격히 탈락하였다. 가력 초기에는 대부분의 하중을 직선구간의 부착에 의해 지지하였으나, 최대 하중의 1/3 지점부터 부착에 의한 기여도가 저감되기 시작하여 최대 하중에서는 대부분 갈고리 지압에 의해 하중을 지지하였다. 횡보강철근이 있는 실험체에서 [실험값]/[콘크리트구조기준 예측값] 비율의 평균이 1.45였다. 35 mm 초과 철근에 적용이 금지된 횡보강철근에 대한 보정계수 0.8을 적용하여도 안전한 갈고리 정착이 가능하다. 고강도콘크리트를 사용한 경우에는 [실험값]/[콘크리트구조기준 예측값]의 비율이 1.0로 다른 경우에 비해 안전율이 부족하였다. 콘크리트강도의 제곱근에 비례하는 콘크리트구조기준은 고강도 콘크리트에서 안전측이 아니므로 콘크리트 압축강도에 대한 영향을 저감시킬 필요가 있다. 실험결과를 회귀분석하여, 콘크리트 압축강도, 묻힘길이, 측면피복두께, 횡보강철근의 영향을 고려한 갈고리철근 정착강도 평가식을 개발하였다. 13개 실험데이터와 비교한 결과, [실험값]/[예측값] 비 평균이 1.0, 변동계수가 10%로 매우 정확히 강도를 예측하였다.