• Title/Summary/Keyword: Hollow Fiber Membrane Module

Search Result 99, Processing Time 0.021 seconds

Processing Characteristics of the Condensed Wastewater Resulting from Food Waste Disposal using a Submerged Polyethylene Hollow Fiber Membrane (음식물 소멸기에서 발생하는 응축폐수의 Polyethylene 침지형 중공사막을 이용한 처리 특성)

  • Ryu, Jae-Sang;Jeon, Tae-Bong;Kim, Jin-Ho;Chung, Kun-Yong
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • This study is conducted about the system that reduces organism after fermenting food waste from a food waste disposal equipment, divides gas made when food waste is fermented into gas and water, and then sends gas to a reactor again, condenses water, and apply it to the MBR system with submerged MF hollow fiber membranes. A submerged MF hollow fiber membrane module was installed to a food waste disposal equipment and a water treatment system made by Bio Hitech Co,. Ltd. to process food waste generated from a staff cafeteria in a H institute for 90 days. For initial seeding of a food waste disposal equipment, 305 kg of rice bran, chaff, and sawdust as well as 1,648 kg of food were input during the operation, and 1,600 L of condensed wastewater occurred. Fermented by-product after finishing running a food waste disposal equipment was 386 kg and its reduction was shown to be 80%. The organism was processed by applying submerged MF hollow fiber membrane module to the MBR system of condensed wastewater, and the result shows reduction rates were BOD 99.9%, COD 97.5%, SS 98.6%, T-N 54.6% and T-P 34.7% and the total colon bacillus was perfectly eliminated.

Mathematical modeling of humidification process by means of hollow fiber membrane contactor

  • Marjani, Azam;Baghdadi, Ali;Ghadiri, Mehdi
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.297-311
    • /
    • 2016
  • Modeling and simulation of air humidification by hollow fiber membrane contactors are investigated in the current study. A computational fluid dynamic model was developed by solving the k-epsilon turbulence 2D Navier-Stokes equations as well as mass conservation equations for steady-state conditions in membrane contactors. Finite element method is used for the study of the air humidification under different operating conditions, with a focus on the humidity density, total mass transfer flux and velocity field. There has been good agreement between simulation results and experimental data obtained from literature. It is found that the enhancement of air stream decreases the outlet humidity from 0.392 to 0.340 (module 1) and from 0.467 to 0.337 (module 2). The results also indicated that there has been an increase in air velocity in the narrow space of shell side compared with air velocity wide space of shell side. Also, irregular arrangement has lower dead zones than regular arrangement which leads to higher water flux.

Study on the Removal of Water Vapor Using PEI/PEBAX Composite Hollow Fiber Membrane (PEI/PEBAX 복합 중공사 막을 이용한 수분 제거에 관한 연구)

  • Park, Chun-Dong;Hyung, Chan-Heui;Kim, Kee-Hong;Choi, Won-Kil;Park, Yeong-Seong;Lee, Hyung-Keun
    • Membrane Journal
    • /
    • v.23 no.2
    • /
    • pp.119-128
    • /
    • 2013
  • In this research, PEI/PEBAX composite hollow fiber membrane was used for the removal of water vapor from gases. PEI (Polyetherimide) substrate membrane was spinned by dry-wet phase inversion method and coated with PEBAX (Polyether block amides) 3533 and PEBAX1657. Fabricated fibers typically had an asymmetric structure of a dense top layer supported by a sponge-like substructure through scanning electron microscopy (SEM). $H_2O/N_2$ mixture gas was used to compare the performance of separation according to temperature, pressure and water activity. The results of PEBAX3533 and PEBAX1657 composite membranes respectively showed $H_2O/N_2$ selectivity of 61.7~118.5 and 85.3~175.4 according to operating conditions. PEBAX3533 composite hollow fiber membranes module showed the water vapor removal of 90%.

Design and Diafiltration Performance of Modified Cellulose and Regenerated Cellulose Hollow Fiber Membrane Hemodiafilter (개질 셀룰로오즈 및 재생 셀룰로오즈 중공사막 혈액투석여과기의 설계 및 투석여과성능)

  • 김재진;박진용
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.221-226
    • /
    • 1993
  • Modules of hemodiafilter were manufactured by using MC-Hp200 and RC-HP4DOA hoi low fiber membranes of Enka Co. in a unique design. The performances of she hemodiafillers were evaluated by measuring the molecular weight cut-off, ultrafiltration rate, clearance, and pressure drop across the hemodiafiter. As a whole, the performances of the RC-HP400A module were superior to those of the MC-Hp200 module. The modules prepared in thls study showed the satisfactory performances for hemodiafiltration.

  • PDF

Preparation and Properties of Hollow Fiber Membrane for CO2/H2 Separation (이산화탄소/수소 분리용 중공사형 기체분리막의 제조 및 특성)

  • Hyung Chul Koh;Mi-jin Jeon;Sang-Chul Jung;Yong-Woo Jeon
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.222-232
    • /
    • 2023
  • In this study, a hollow fiber support membrane was prepared by a non-solvent induced phase separation (NIPS) method using a polysulfone (PSf). The prepared hollow fiber support membrane was coated with PDMS and Pebax to prepare a hollow fiber composite membrane. The prepared composite membrane was measured for permeance and selectivity for pure CO2, H2, O2 and N2. Gas separation performance of the module having the highest selectivity (CO2/H2) among the prepared composite membrane modules was measured according to the change in stage cut using simulated gas. The composition of the simulated gas used at this time was 70% CO2 and 30% H2. In the 1 stage experiment, it was possible to obtain values of about 60% of H2 concentration and 12% of H2 recovery. In order to overcome the low H2 concentration and recovery, 2 stage serial test was performed, and through this, it was possible to achieve 70% H2 concentration and 70% recovery. Through this, it was possible to derive a separation process configuration for CO2/H2 separation.

A Numerical Analysis of Direct Contact Membrane Distillation for Hollow Fiber Membrane (중공사형 분리막에 대한 직접접촉식 막분리 공정의 수치해석)

  • Shin, Ho-Chul;Chung, Kun-Yong
    • Membrane Journal
    • /
    • v.20 no.4
    • /
    • pp.342-350
    • /
    • 2010
  • Membrane distillation (MD) is a separation process which higher vapor pressure components are evaporated in mixed liquid solution through hydrophobic membrane with 0.1 or $0.5{\mu}m$ pore size. In this study, direct contact membrane distillation process for hollow fiber module were interpreted numerically using the "COMSOL Multiphysics" software. The variables for the system were temperatures and flow rates of lumen and shell side solutions. The permeate flux increased from 1.0 to $3.8L/m^2{\cdot}hr$ as temperature of the feed solution for lumen increased from 30 to $50^{\circ}C$. However the effect of shell solution temperature on permeate flux was relatively low. Also, the optimum velocity of lumen feed was obtained at 0.15 m/s ($Re_L=135$) by considering MD permeate flux as well as operating pressure loss.

A Submerged Membrane Bioreactor with Anoxic-oxic Recycle for the Treatment of High-strength Nitrogen Wastewater

  • Shim, Jin-Kie;Yoo, Ik-Keun;Lee, Young-Moo
    • Korean Membrane Journal
    • /
    • v.3 no.1
    • /
    • pp.32-38
    • /
    • 2001
  • Using the hollow fiber membrane module in a lab-scale membrane bioreactor, the anoxic- oxic (AO) process for nitrogen removal was operated for about one year. For the influent wastewater containing 1,200-1,400 mg $1^{-1}$ of CODcr and 200-310 mg $1^{-1}$ of nitrogen, this process achieved a high quality effluent of less than 30 mgCOD $liter^{-1}$ and 50 mgN $liter^{-1}$. The removal rate of organics was above 98% at a loading rate larger than 2.5 kgCOD $m^{-3}$$d^{-1}$. When the internal recycle from the oxic to the anoxic reactor changed room 2n to 600% rout the influent flow rate, the nitrogen removal rate increased from about 70 to 90% at a loading rate of 0.4 kgT-N m-s d-1. The initial increase of transmembrane pressure (TMP) was observed after a 4-month operation while maintaining the flux and MLSS concentration at 7-9 1 $m^2$ $h^{-1}$ and 6,000-14,000 mg $1^{-1}$, respectively. The TMP could be maintained below 15 cmHg for an 8-month operation. The chemical cleaning with an acid followed by an immersion in an alkali solution gave better cleaning result with the membrane operated for 10 month rather than that only by an alkali immersion.

  • PDF

Study on the Separation of CO2 from Flue Gas Using Polysulfone Hollow Fiber Membrane (폴리설폰 중공사막을 이용한 연소 배기가스 중 이산화탄소 분리에 관한 연구)

  • Kim, Seongcheon;Chun, Jeonghyeon;Chun, Youngnam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.147-152
    • /
    • 2014
  • In this research, polysulfone hollow fiber membrane was used to recover $CO_2$ which is one of greenhouse gases from flue gas stream being emitted after the combustion of fossil fuels. The prerequisite requirement is to design the membrane process producing high-purity $CO_2$ from flue gas. For separation of $CO_2$, a membrane module and flue gas containing 10% carbon dioxide was used. The effects of operating conditions such as pressure, temperature, feed gas composition and multi-stage membrane on separation performance were examined at various stage cuts. Higher operating pressure and temperature increased carbon dioxide concentration and recovery ratio in permeate. Recovery ratio and separation efficiency increased if a higher content of $CO_2$ injection gas composition. Three-stage membrane system was producing a 95% $CO_2$ with 90% recovery from flue gas. The separation efficiency of three-stage membrane system was higher than one-stage system.

Field Application of the Membrane System for the Recovery of VOCs from the Automobile Painting Process (도장공정 휘발성 유기화합물 회수를 위한 분리막 시스템의 현장 적용성 평가)

  • Choi, Whee Moon;Cho, Soon Haing;Kim, Soon Tae;Lee, Chung Seop;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.23 no.2
    • /
    • pp.129-135
    • /
    • 2013
  • To recover of volatile organic compounds (VOCs) induced by painting process, we prepared separation system using hollow fiber membrane modules and evaluated the recovery performance of VOCs with different feed pressure and operating time. Concentration of volatile organic compound in permeate through the membrane increased with increasing operating time and pressure. Performance of the membrane for removing the VOCs when we applied 2-stage process showed better performance than that of single stage process.

Development of High-Durability Ceramic Hollow Fiber and Performance Evaluation of Contact Membrane Process according to Pressure Conditions (고내구성 세라믹 중공사 개발과 압력 조건에 따른 접촉막 공정의 특성 평가)

  • Lee, Seung Hwan;Jeong, Byeong Jun;Shin, Min Chang;Zhuang, Xuelong;Jung, Jiwon;Lee, Yeon Jun;Won, Dongyeon;Park, Jung Hoon
    • Membrane Journal
    • /
    • v.30 no.6
    • /
    • pp.443-449
    • /
    • 2020
  • In this study, CO2 separation experiment was performed on a CH4/CO2 mixed gas using a ceramic hollow fiber membrane contactor module (HFMC). In order to fabricate high-durability HFMC, a high-durability hollow fiber membrane was prepared and evaluated. HFMC was fabricated using the prepared hollow fiber membrane, and the experiment used a mixture of CH4/CO2 (30% CO2, CH4 balance) and monoethanolamine (MEA). During HFMC operation, the effect of gas and absorbent pressure on the CO2 removal efficiency was evaluated. The CO2 removal efficiency increased as the gas pressure increased, and the CO2 absorption flux also showed a tendency to increase with the liquid flow rate. In addition, when the CO2 absorption rate was less than 40%, LTS-1, a counter-current form where the absorbent enters from the bottom, has higher CO2 removal performance than LTS-2, a countercurrent form in which the absorbent enters from the top. and when the absorption rate was 40% or higher, LTS-2 had higher performance than LTS-1.