• Title/Summary/Keyword: Hole-filling

Search Result 178, Processing Time 0.053 seconds

Conversion Method of 3D Point Cloud to Depth Image and Its Hardware Implementation (3차원 점군데이터의 깊이 영상 변환 방법 및 하드웨어 구현)

  • Jang, Kyounghoon;Jo, Gippeum;Kim, Geun-Jun;Kang, Bongsoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2443-2450
    • /
    • 2014
  • In the motion recognition system using depth image, the depth image is converted to the real world formed 3D point cloud data for efficient algorithm apply. And then, output depth image is converted by the projective world after algorithm apply. However, when coordinate conversion, rounding error and data loss by applied algorithm are occurred. In this paper, when convert 3D point cloud data to depth image, we proposed efficient conversion method and its hardware implementation without rounding error and data loss according image size change. The proposed system make progress using the OpenCV and the window program, and we test a system using the Kinect in real time. In addition, designed using Verilog-HDL and verified through the Zynq-7000 FPGA Board of Xilinx.

Transposition of Flexor Carpi Radialis and Superficial Digital Flexor Muscles for Reconstruction of Carpal Injury in a Dog (개에서 요골쪽앞발목굽힘근과 얕은앞발가락굽힘근을 이용한 앞발목 부위의 연부조직 결손 재건 증례)

  • So, Kyoung-Min;Kim, Joo-Ho;Lee, Hae-Beom;Heo, Su-Young;Ko, Jae-Jin;Lee, Cheol-Ho;Chon, Seung-Ki;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.276-279
    • /
    • 2007
  • A 2-year-old male, 3 kg body weight Japanese Chin was injured in the automobile accident three months ago. The dog became antebrachiocarpal joint instability, and performed pancarpal arthrodesis using 3 K-wires in localanimal hospital. But, the result was failure. Therefore the dog was referred to Chonbuk Animal Medical Center, Chonbuk National University. In physical examination, right carpal joint instability, knuckling sign and pain were evident. In radiography, sclerosis was observed on the 4th carpal bone. Complete blood count (CBC), serum chemistry and urinalysis finding were within reference ranges. Pancarpal arthrodesis was re-performed using 7-hole plate. However, mild skin and muscle defects was appeared by skin tension of extremity. We expected that granulation would fill the defect, but inflammation was continued on the lesions for 3 days. So, operation which is filling it was done by using the muscle flap and tubed skin flap. The donor muscles were flexor carpi radialis and superficial digital flexor muscles. After 7 days, the muscle flap was survived, but tubed skin flap was necrosed. After 20 days, the skin defect was substituted with granulation tissues. The flexor carpi radialis muscle and superficial digital flexor muscle transposition can be a useful procedure for reconstructing soft tissue defects in the carpal and metacarpal areas.

An Extraction Method of Glomerulus Region from Renal Tissue Image (신장조직 영상에서 사구체 영역의 추출법)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.2
    • /
    • pp.70-76
    • /
    • 2012
  • In this paper, an automatic extraction method of glomerulus region from human renal tissue image is presented. The important information reflecting the state of kidneys richly included in the glomeruli, so it should be the first step to extract the glomerulus region from the renal tissue image for the further quantitative analysis of the renal condition. Especially, there is no clear difference between the glomerulus and other tissues, so the glomerulus region can not be easily extracted from its background by the existing segmentation methods. The outer edge of a glomerulus region is regarded as a common property for the regions of this kind ; a two- dimensional Gaussian distribution is used to convolve with an original image first and then the image is thresholded at this blurred image ; a closed curve corresponding to the outer edge can be obtained by usual pattern processing skills like thinning, branch-cutting, hole-filling etc., Finally, the glomerulus region can be obtained by extracting the area in the original image surrounded by the closed curve. The glomerulus regions are correctly extracted by 85 percentages and experimental results show the proposed method is effective.

Automatic Lung Segmentation using Hybrid Approach (하이브리드 접근 기법을 사용한 자동 폐 분할)

  • Yim, Yeny;Hong, Helen;Shin, Yeong-Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.7
    • /
    • pp.625-635
    • /
    • 2005
  • In this paper, we propose a hybrid approach for segmenting the lungs efficiently and automatically in chest CT images. The proposed method consists of the following three steps. first, lungs and airways are extracted by two- and three-dimensional automatic seeded region growing and connected component labeling in low-resolution. Second, trachea and large airways are delineated from the lungs by two-dimensional morphological operations, and the left and right lungs are identified by connected component labeling in low-resolution. Third, smooth and accurate lung region borders are obtained by refinement based on image subtraction. In experiments, we evaluate our method in aspects of accuracy and efficiency using 10 chest CT images obtained from 5 patients. To evaluate the accuracy, we Present results comparing our automatic method to manually traced borders from radiologists. Experimental results show that proposed method which use connected component labeling in low-resolution reduce processing time by 31.4 seconds and maximum memory usage by 196.75 MB on average. Our method extracts lung surfaces efficiently and automatically without additional processing like hole-filling.

Binarization and Stroke Reconstruction of Low Quality Character Image for Effective Character Recognition (효과적인 문자 인식을 위한 저 품질 문자 영상의 이진화 및 획 재구성 방법)

  • Kim, Do-Hyeon;Cha, Eui-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.608-618
    • /
    • 2007
  • Image binarization is an important preprocessing to identify the object of interest by dividing pixels into the background and object. We proposes efficient binarization method and a stroke reconstruction method of the low quality character image for an effective character recognition. First, the character image is binarized by using the both advantages of local and global thresholding method and then the noise elimination around the character stroke and the hole filling on the stoke by the analysis of the binarized stroke image are performed to enhance the quality of the character stroke. Proposed binarization algorithm for character image achieved an efficiency of both processing speed and performance by the adaptive threshold selection. Moreover, We could get a high qualify binary image by a stroke reconstruction of the step-by-step denoising process.

Case study of riser design using casting simulation in gravity cast method (중력주조 공법에서 주조해석 시뮬레이션을 이용한 압탕설계 사례 연구)

  • Ko, Sang-Bae;Han, Ki-Won;Kim, Hyung-Jun;Han, Tae-Soo;Han, Seong-Ryeol;Kim, kyung-A;Choi, Kye-Kwang;Yun, Jae-Woong;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.15 no.2
    • /
    • pp.30-35
    • /
    • 2021
  • The casting method uses a mold to solidify a liquid metal to make a solid metal. Since it uses a liquid metal with the least deformation resistance, it has the characteristic that it can easily manufacture even a complex shape. However, the process of solidifying a liquid metal into a solid metal inevitably involves a volume change and contains internal defects such as shrinkage holes. Therefore, in the design of the casting plan, an excess volume called a pressurization compensates for the volume shrinkage. in the product, and it induces the shrinkage hole defects to occur in parts other than the product1). In this study, casting analysis was performed using casting analysis software (anycasting) in order to optimize the design of the tilting gravity casting method for automobile brackets. In particular, the filling and solidification analysis according to the shape and volume of the pressurized metal was conducted, and applied to the actual product to study the effect of the pressurized metal on the shrinkage defect. Through this study, it is possible to understand the effect of the pressure metal on shrinkage defects in the actual product and propose a design of the pressure metal that improves reliability and productivity.

Effect of cavity shape, bond quality and volume on dentin bond strength (와동의 형태, 접착층의 성숙도, 및 와동의 부피가 상아질 접착력에 미치는 영향)

  • Lee, Hyo-Jin;Kim, Jong-Soon;Lee, Shin-Jae;Lim, Bum-Soon;Baek, Seung-Ho;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.450-460
    • /
    • 2005
  • The aim of this study was to evaluate the effect of cavity shape, bond quality of bonding agent and volume of resin composite on shrinkage stress developed at the cavity floor. This was done by measuring the shear bond strength with respect to iris materials (cavity shape , adhesive-coated dentin as a high C-factor and Teflon-coated metal as a low C-factor), bonding agents (bond quality: $Scotchbond^{TM}$ Multi-purpose and Xeno III) and iris hole diameters (volume; 1mm or 3mm in $diameter{\times}1.5mm$ in thickness). Ninety-six molars were randomly divided into 8 groups ($2{\times}2{\times}2$ experimental setup). In order to simulate a Class I cavity, shear bond strength was measured on the flat occlusal dentin surface with irises. The iris hole was filled with Z250 restorative resin composite in a bulk-filling manner. The data was analyzed using three-way ANOVA and the Tukey test. Fracture mode analysis was also done When the cavity had high C-factor, good bond quality and large volume, the bond strength decreased significantly The volume of resin composite restricted within the well-bonded cavity walls is also be suggested to be included in the concept of C-factor, as well as the cavity shape and bond quality. Since the bond quality and volume can exaggerate the effect of cavity shape on the shrinkage stress developed at the resin-dentin bond, resin composites must be filled in a method, which minimizes the volume that can increase the C-factor.

FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE (임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석)

  • Chung Kyung-Min;Chung Chae-Heon;Jeong Seung-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY (IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구)

  • Kim, Byung-Ock;Hong, Kug-Sun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

Fabrication of $TiO_2$ Electrode Containing Scattering Particles in Dye-Sensitized Solar Cells (산란 입자를 포함하는 염료감응 태양전지용 $TiO_2$ 전극 제조)

  • Lee, Jin-Hyoung;Lee, Tae-Kun;Kim, Cheol-Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.57-62
    • /
    • 2011
  • The energy conversion efficiency of DSSCs (Dye-Sensitized Solar Cells) is dependent on the powder size, the structure, and the morphology of $TiO_2$ electrode. The higher efficiency is obtained with high surface area of the nanoanatase-$TiO_2$ powder adsorbed onto a lot more of the dye. Also, the enhancement of light scattering increases the efficiency with high adsorption of the dye. Powder size, crystalline phase, and shape of $TiO_2$ obtained by hydrothermal method have 15-20 nm, anatase and round. $TiO_2$ electrode has fabricated with the mixture of scattering $TiO_2$ particle with 0.4 ${\mu}m$ in nano-sized powder. Conversion efficiency of series of DSSCs was measured with volume fraction of scattering particle. Photovoltaic characteristics of DSSCs with 10% scattering particles are 3.51 mA for Jsc (short circuit current), 0.79 V for Voc(open circuit potential), filling factor 0.619 and 6.86% for efficiency. Jsc was improved by 11% and enhancement of efficiency by 0.77% compared with that of no scattering particles. The confinement of inserted light by light scattering particles has more increase of the injection of exiton(electron-hole pair) and decrease of moving path in electron. Efficiencies of DSSCs with more than 10% for scattering particles have reduced with increasing the pore in the $TiO_2$ electrode.