References
- Albrektsson, T., Branemark, P.I.. Hansson, H.A., Lindstrom, J .. Osseointegration titanium implants. Requirements for ensuring long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 52: 155-170,1981
-
Friberg, B.. .Jemt. T.. Lekholm, U.. Early failures in 4641 cosecutively placed Br
${\aa}$ nsmark dental implants. A study from stage I surgery to the connection of completed prostheses. Int. J Oral Maxillofac Implants 6:142-146,1991 -
Jaffin. R.A., Berman, C.L.. The excessive loss of Br
${\aa}$ nernark fixtures in type IV bone. A 5-year analysis. J. Periodonto1 62:24.1991 - Misch, C.E .. Contemporary implant dentistry. 1993 Mosby-Year Book Inc St Louis
- Hur,J.K., Chung, C.H., Jeong,S.M.. Finite element analysis of implant prosthesis according to diameter and length of implant fixture. J. Kor Acad.
- Clarizio. L.F.. Techniques for ideal implant placement in the mandibular first molar position. Compend Con tin Educ Dent 16(8) :806-813,1995
- Jarvis, W.C.. Biomechanical advantages of wide-diameter implants. Compend Contin Educ Dent 18(7) :687-696.1997
- Renouard, F., Arnoux, J.P., Sarment, D.P.. Five-mm-diameter implants without a smooth surface collar: Report on 98 consecutive placements. Int. J. Oral Maxillofac Implants 14: 101-107,1999
- Matsushita, Y., Kithoh, M., Mizuta, K., Ikeda, H., Suetsugu, T.. Two-dimentional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. J. Oral Implantol 16:6-11.1990
- Morimoto, K., Kihara, A.. Takeshita, F., Suetsugu, T.. An experimental study on the tissue compatibility of the titanium bladevent implant coated with HAP-alumina in the semi- functional state. J. Oral Implantol 13:387-401.1987
- Haraldson. T., Zarb, G.A .. A 10-year follow-up study of the masticatory system after treatment with osseointegrated implant bridges. Scand J Dent Rec 96: 243-252,1988
- Lum. L.B., Osier, J.F.. Load transfer from endosteal implants to supporting bone: An analysis using statics. Part one: Horizontal loading. J. Oral Implantol 18:343-348,1992
- Holmes, D.C., Grigsby, W.R, Goel, V.K., Keller, J.C.. Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: A finite element stress analysis. Int. J. Oral Maxillofac Implants 7:450458,1992
- Kinni, M.E., Hokama , S.N., Caputo, A.A. Force transfer by osseointegration implant devices. Int. J. Oral Maxillofac Implants 1:11-14,1987
- Rangert, B., .Jemt. T., Jorneus. L.. Forces and moments on Branemak implants. Int. J. Oral Maxillofac Implants 4:241-247, 1989
- Rangert, B., Krogh, P.H.J., Langer, B., van Roekel, N.B .. Bending overload and implant fracture: A retrospective clinical analysis. Int. J. Oral Maxillofac Implants 10:326-334,1995
- Lum. L.B .. A biomechanical rationale for the use of short implants. J. Oral Implantol 17: 126-131, 1991
- Lum. L.B., Osier, J.F.. Load transfer from endosteal implants to supporting bone: An analysis using statics. Part two: Axial loading. J. Oral Implantol 18:349-353,1992
- Borchers, L., Reichart, P .. Three-dimentional stress distribution around a dental implant at different stages of interface development. J. Dent Rec 62: 155-159,1983
- Clelland, N.L., Lee, J.K., Bimbenet, O.C., Gilat, A.. Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant. J. Prosthodont 2: 183-189, 1993
- Langer, B., Langer, L., Herrmann, I., .Jorneus. L.. The wide fixture: a solution for special bone situations and a rescue for the compromised implant. Part 1. Int. J. Oral Maxillofac Implants 8:400-408,1993
- Boggan, RS., Strong, J.T., Misch, C.E., Bidez, M.W.. Influence of hex gometry and prosthetic table width on static and fatigue strength of dental implants. J. Prosthet Dent 82:436-440,1999
- Lekholm, D., van, Steenberghe, D., Herrmann, I.. Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5-year multicenter study. Int. J. Oral Maxillofac Implants 9:627-635,1994
- Ivanoff, C.J., Grodahl, K., Sennerby, L., Bergstr m, C., Lekholrn. U.. Influence of variations in implant diameters: A 3- to 5-year retrospective clinical report. Int. J. Oral Maxillofac Implants 14: 173-180,1999
- Minsk, L., Polson, A.M., Weisgold, A, Rose, L.F., Baumgarrten, H.. Outcome failures of endosseous implants from a clinical training center. Compend Contin Educ Dent 17(9): 848-856,1996