FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE

임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석

  • Chung Kyung-Min (Dept. of Prosthodontics, College of Dentistry, Chosun University) ;
  • Chung Chae-Heon (Dept. of Prosthodontics, College of Dentistry, Chosun University) ;
  • Jeong Seung-Mi (Dept. of Dentistry, College of Medicine, Ewha Womans University)
  • 정경민 (조선대학교 치과대학 보철학교실) ;
  • 정재헌 (조선대학교 치과대학 보철학교실) ;
  • 정승미 (이화여자대학교 의과대학 치과학교실 보철과)
  • Published : 2003.10.01

Abstract

Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

Keywords

References

  1. Albrektsson, T., Branemark, P.I.. Hansson, H.A., Lindstrom, J .. Osseointegration titanium implants. Requirements for ensuring long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 52: 155-170,1981
  2. Friberg, B.. .Jemt. T.. Lekholm, U.. Early failures in 4641 cosecutively placed Br${\aa}$nsmark dental implants. A study from stage I surgery to the connection of completed prostheses. Int. J Oral Maxillofac Implants 6:142-146,1991
  3. Jaffin. R.A., Berman, C.L.. The excessive loss of Br${\aa}$nernark fixtures in type IV bone. A 5-year analysis. J. Periodonto1 62:24.1991
  4. Misch, C.E .. Contemporary implant dentistry. 1993 Mosby-Year Book Inc St Louis
  5. Hur,J.K., Chung, C.H., Jeong,S.M.. Finite element analysis of implant prosthesis according to diameter and length of implant fixture. J. Kor Acad.
  6. Clarizio. L.F.. Techniques for ideal implant placement in the mandibular first molar position. Compend Con tin Educ Dent 16(8) :806-813,1995
  7. Jarvis, W.C.. Biomechanical advantages of wide-diameter implants. Compend Contin Educ Dent 18(7) :687-696.1997
  8. Renouard, F., Arnoux, J.P., Sarment, D.P.. Five-mm-diameter implants without a smooth surface collar: Report on 98 consecutive placements. Int. J. Oral Maxillofac Implants 14: 101-107,1999
  9. Matsushita, Y., Kithoh, M., Mizuta, K., Ikeda, H., Suetsugu, T.. Two-dimentional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. J. Oral Implantol 16:6-11.1990
  10. Morimoto, K., Kihara, A.. Takeshita, F., Suetsugu, T.. An experimental study on the tissue compatibility of the titanium bladevent implant coated with HAP-alumina in the semi- functional state. J. Oral Implantol 13:387-401.1987
  11. Haraldson. T., Zarb, G.A .. A 10-year follow-up study of the masticatory system after treatment with osseointegrated implant bridges. Scand J Dent Rec 96: 243-252,1988
  12. Lum. L.B., Osier, J.F.. Load transfer from endosteal implants to supporting bone: An analysis using statics. Part one: Horizontal loading. J. Oral Implantol 18:343-348,1992
  13. Holmes, D.C., Grigsby, W.R, Goel, V.K., Keller, J.C.. Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: A finite element stress analysis. Int. J. Oral Maxillofac Implants 7:450458,1992
  14. Kinni, M.E., Hokama , S.N., Caputo, A.A. Force transfer by osseointegration implant devices. Int. J. Oral Maxillofac Implants 1:11-14,1987
  15. Rangert, B., .Jemt. T., Jorneus. L.. Forces and moments on Branemak implants. Int. J. Oral Maxillofac Implants 4:241-247, 1989
  16. Rangert, B., Krogh, P.H.J., Langer, B., van Roekel, N.B .. Bending overload and implant fracture: A retrospective clinical analysis. Int. J. Oral Maxillofac Implants 10:326-334,1995
  17. Lum. L.B .. A biomechanical rationale for the use of short implants. J. Oral Implantol 17: 126-131, 1991
  18. Lum. L.B., Osier, J.F.. Load transfer from endosteal implants to supporting bone: An analysis using statics. Part two: Axial loading. J. Oral Implantol 18:349-353,1992
  19. Borchers, L., Reichart, P .. Three-dimentional stress distribution around a dental implant at different stages of interface development. J. Dent Rec 62: 155-159,1983
  20. Clelland, N.L., Lee, J.K., Bimbenet, O.C., Gilat, A.. Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant. J. Prosthodont 2: 183-189, 1993
  21. Langer, B., Langer, L., Herrmann, I., .Jorneus. L.. The wide fixture: a solution for special bone situations and a rescue for the compromised implant. Part 1. Int. J. Oral Maxillofac Implants 8:400-408,1993
  22. Boggan, RS., Strong, J.T., Misch, C.E., Bidez, M.W.. Influence of hex gometry and prosthetic table width on static and fatigue strength of dental implants. J. Prosthet Dent 82:436-440,1999
  23. Lekholm, D., van, Steenberghe, D., Herrmann, I.. Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5-year multicenter study. Int. J. Oral Maxillofac Implants 9:627-635,1994
  24. Ivanoff, C.J., Grodahl, K., Sennerby, L., Bergstr m, C., Lekholrn. U.. Influence of variations in implant diameters: A 3- to 5-year retrospective clinical report. Int. J. Oral Maxillofac Implants 14: 173-180,1999
  25. Minsk, L., Polson, A.M., Weisgold, A, Rose, L.F., Baumgarrten, H.. Outcome failures of endosseous implants from a clinical training center. Compend Contin Educ Dent 17(9): 848-856,1996