• Title/Summary/Keyword: Hoffmann method

Search Result 13, Processing Time 0.023 seconds

Consideration for Setting Reference Range for Adrenocorticotropic Hormone Test according to Blood Collection Time (채혈 시간에 따른 부신피질 자극 호르몬 검사의 참고치 설정에 관한 고찰)

  • Ji-Hye Park;Jin-Ju Choi;Soo-Yeon Lim;Seon-Hee Yoo;Sun-Ho Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.42-46
    • /
    • 2023
  • Purpose The reference range described in Adrenocorticotropic Hormone reagent used in our laboratory is 10-60 pg/mL at 8 a.m. to 10 a.m., and 6-30 pg/mL at 8 p.m. to 10 p.m. However, in the case of outpatients, blood is mainly collected between 10 a.m. and 6 p.m., accounting for 57.8% of the total. Therefore, This study is intended to help make a more accurate diagnosis by reevaluating the reference range provided by the manufacturer of the Adrenocorticotropic Hormone reagent and setting split-timed reference range. Materials and Methods The patients collected blood before 10 a.m. were group A (68 people), and the patients collected blood after 10 a.m. were set to group B (80 people). A T-test was performed between groups to test their significance. And it was confirmed whether it was necessary to set the gender classification as a subgroup. The method of setting the reference range was calculated by the Bayesian's method and the Hoffmann's method. Results The reference range of Group A was 8.6 to 60.6 pg/mL by the Bayesian's method, and the Hoffmann's method was 3.6 to 61.3 pg/mL. The reference range of Group B was 6.9 to 50.5 pg/mL when applying the Bayesian's method, and the Hoffmann method's was 2.3 to 48.9 pg/mL. Conclusion This study was concluded that it was necessary to set the split-timed reference range. Through this study, the later the blood collection time, the lower the level of Adrenocorticotropic Hormone, indicating that blood collection time is important for patients with clinical significance. If a large number of subjects are selected and supplemented in the future, it is believed that systematic and accurate reference range can be set.

  • PDF

Some Considerations on Cyclopentadiene by the Extended Huckel Method (Cyclopentadiene의 電子狀態와 反應性 (Extended Huckel Method에 依한))

  • Pack, Byung-Kak
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.85-88
    • /
    • 1968
  • The resonance parameter value between the saturated carbon and unsaturated carbon atom in cyclopentadiene has been evaluated. And then cyclopentadiene has been investigated on the correlations between it's electronic structures and reactivities by means of the extended Huckel method proposed by R. Hoffmann.

  • PDF

Application of Experimental Design to Optimize Vitamin C-90 Tabletting Performance

  • Chang, Kuei-Tu
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.67-77
    • /
    • 1994
  • The RMS statistical approach has demonstrated its potential in developing pharmaceutical dosage forms and in improving tabletting performance. Using an optimized formula, the tabletting performances of vitamin C-90 such as compressibility, disintegration time, lubrication and friability are significantly enhanced when compared with the performance of a traditional test formula. More important, this method also enables us to serve our customers better. Any customized modification of a suggested formula or any technical problem related performance etc. can be readily resolved by simple examination of the models.

  • PDF

Fitts' Law for Angular Foot Movement in the Foot Tapping Task

  • Park, Jae-Eun;Myung, Ro-Hae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.647-655
    • /
    • 2012
  • Objective: The purpose of this study was to confirm difference between angular foot movement time and existing foot Fitts' law predicting times, and to develop the angular foot Fitts' law in the foot tapping task. Background: Existing studies of foot Fitts' law focused on horizontal movement to predict the movement time. However, when driving a car, humans move their foot from the accelerator to the brake with a fixed heel. Therefore, we examined the experiment to measure angular foot movement time in reciprocal foot tapping task and compared to conventional foot Fitts' law predicting time. And, we developed the angular foot Fitts' law. Method: In this study, we compared the angular foot movement time in foot tapping task and the predicted time of four conventional linear foot Fitts' law models - Drury's foot Fitts' law, Drury's ballistic, Hoffmann's ballistic, Hoffmann's visually-controlled. 11 subjects participated in this experiment to get a movement time and three target degrees of 20, 40, and 60 were used. And, conventional models were calculated for the prediction time. To analyze the movement time, linear and arc distance between targets were used for variables of model. Finally, the angular foot Fitts' law was developed from experimental data. Results: The average movement times for each experiment were 412.2ms, 474.9ms, and 526.6ms for the 89mm, 172mm, and 253mm linear distance conditions. The results also showed significant differences in performance time between different angle level. However, all of conventional linear foot Fitts' laws ranged 135.6ms to 401.2ms. On the other hand, the angular foot Fitts' law predicted the angular movement time well. Conclusion: Conventional linear foot Fitts' laws were underestimated and have a limitation to predict the foot movement time in the real task related angular foot movement. Application: This study is useful when considering the human behavior of angular foot movement such as driving or foot input device.

Establishment of Reference Value of Insulin Using the Statistical Analysis (통계적 분석을 통한 Insulin의 정상 참고치 설정)

  • Kim, Whe-Jung;Yoon, Pil-Young;Shin, Young-Goon;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.143-146
    • /
    • 2010
  • Purpose: Insulin is involved in carbohydrate metabolism and also it's very important because it increases storage of glycogen, synthesis of fatty acids, absorption of amino acid, synthesis of protein. Insulin is clinically useful when we evaluate fasting patients in hypoglycemia, classify and predict diabetes, assess the activity of ${\beta}$-cell, research insulin resistance. We are going to increase usability of insulin assay by establishing normal reference value according to statistical analysis. Material & Method: We selected 6,648 patients who visited asan health medical center from May to August in 2008. We set exclusion criteria as family of diabetes, diabetes medication, the past history of blood glucose rise, more than 100 mg/dL in normal fasting blood glucose, outside the scope of BMI 18.5~22.9 $kg/m^2$, and more than HbA1c 6.5%. We determine whether the subgroup is portioned as sex and age or not and establish normal reference value by conducting statistical analysis as Bayesian's method and Hoffman's method. Result: Portioning of subgroup as sex and age is not needed. By statistical analysis of Bayesian method, results 1.5-11.0 uIU/mL. By statistical analysis of Hoffman method, results 1.8~12.8 uIU/mL. Conclusion: We established 1.8~12.8 uIU/mL as Insulin normal reference value by Hoffman method. This is a similar value with reporting reference value 1.7~11.8 uIU/mL in kit. This will enhance the usability of insulin assay by establishing normal reference value.

  • PDF

Establishment of Reference Intervals of Osteocalcin according to Age in Women for Health Promotion Center (건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정)

  • Kang, Ji-Soon;Yoo, Byoung-Joo;Oh, Jung-Eun;Kim, Geon-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.104-111
    • /
    • 2009
  • Purpose: Osteocalcin is also known as the bone gamma-carboxyglutamic acid (Gla) protein (BGP), is noncollagenous bone protein synthesized by osteoblasts. Serum concentrations of Osteocalcin have been used as a biochemical marker of bone turnover. The reference intervals of Osteocalcin is categorized by kit corporation according to the age. However, each laboratory should establish its own reference intervals. In this study, the variation in the serum Osteocalcin level were used to find actual standard age-specific Osteocalcin reference intervals. Materials and Methods: We have selected 864 healthy females aged 20~80 years who visited a health promotion center between Aug. 2007 and Sep. 2008. The Osteocalcin IRMA Kit (OSTEO-RIACT, CIS Bio international, Gif-sur-Yvette, France) was used for the quantification. Each results were analyzed with the SPSS 12.0 statistical software. Results: The analyzed reference intervals of Osteocalcin by using Hoffmann method are from 8.8~39.4 ng/mL to 6.3~28.8 ng/mL for the case of the age from 20 to 30, from 7.7~31.9 ng/mL to 5.9~17.4 ng/mL for the case of the age from 31 to 40, and from 8.0~36.0 ng/mL to 5.5~20.1 ng/mL for the case of the age from 41 to 50, and from 8.0~50.5 ng/mL to 6.7~27.0 ng/mL for the case of the age from 51 to 60, and from 12.9~55.9 ng/mL to 7.5~27.5 ng/mL for the case of the age from 61 to 80. Reference intervals of Osteocalcin were not in agreement with those recommended by the manufacturers. Conclusions: Osteocalcin is used as an indication of metabolic bone diseases. So in our study we wanted to provide reference intervals of Osteocalcin that can be useful to a clinical decisions. Also, previous reference intervals should not be re-used and new intervals should be set by continuous analyzing.

  • PDF

Evaluation of reference value of anti-Glutamic acid decarboxylase antibody for cerebrospinal fluid (뇌척수액에서 항 Glutamic acid decarboxylase 항체검사의 참고치 설정)

  • Park, Min-Ho;Shin, Sun-Young;Youn, Tae-Seok;Shin, Hi-Jung;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.28-30
    • /
    • 2017
  • Purpose Anti-Glutamic acid decarboxylase antibody test (GAD Ab) has been used as a predictor of type 1 diabetes. GAD Ab has also been shown to be highly potent in cerebrospinal fluid (CSF) of patients with suspected diabetic peripheral neuropathy. Recently, it has been known that clinical significance of GAD Ab using CSF is useful for the neurological disorders. However, the reference value of anti-GAD Ab has been provided only for serum. In this experiment, we estimated the reference value of anti-GAD antibody for CSF in neurological patients. Materials and Methods A total of 211 neurological patients were enrolled. Serum and CSF were analyzed by radioimmunoassay (RIA) using commercial RIA anti-GAD Ab kit (RSR, London, United Kingdom). Normal saline was used as the normal CSF control because CSF is most similar to 0.9% normal saline. Results The mean value of normal CSF control was 1.97 U/mL, and two standard deviations (2SD) was 1.44 U/mL. Based on this data, the expected reference range of CSF could be estimated from 0.54 U/mL to 3.40 U/mL Conclusion The reference range of normal CSF control using normal saline obtained with Hoffmann's method. However, there will be a need to validate the CSF reference values using human normal CSF.

  • PDF

Characteristics of Optimized Analytical Method of Hydrogen Cyanide in Cigarette Mainstream Smoke by Using Continuous Flow Analyzer(CFA) (Continuous Flow Analyzer(CFA)를 이용한 담배 주류연 중 Hydrogen Cyanide(HCN)의 최적 분석방법 구명)

  • Na, Seung-Ju;Eo, Sung-Je;Kim, Do-Yeon;Bock, Jin-Young;Hwang, Keon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.31 no.1
    • /
    • pp.39-44
    • /
    • 2009
  • Hydrogen cyanide (HCN) is present in both the particulate and vapor phase of cigarette mainstream smoke. It is one of the 44 harmful substances on Hoffmann's list and is known to be a major ciliatoxic agent in cigarette mainstream smoke. Typically the determination of HCN in cigarette mainstream smoke has been done through colorimetric and electrochemical techniques, such as UV-spectrophotometry (UV), continuous flow analyzer (CFA), ion chromatography (IC) and capillary GC-ECD. In particular, CFA commonly has been using analysis hydrogen cyanide in cigarette smoke and the basic principle is pyridine-pyrazolone reaction. In this study, the more optimized analytical method is suggested isonicotinic acid-pyrazolone reaction method than previous pyridine-pyrazolone reaction method, a commonly used method for the determination of cyanide in water and air, by CFA. Sample collection was optimized by trapping particulate and vapor phase of smoke separately. The optimum NaOH concentration of the trapping solution was shown to be 0.2 M. HCN was stable up to 6 hours in this concentration but only 3 hours in 0.1 M solution. The sensitivity of this method was fairly good and it might be used in analysis of HCN in cigarette mainstream smoke.

CCD PHOTOMETRY OF CONTACT BINARY WZ Cephei (접촉쌍성 WZ Cephei의 CCD 측광관측)

  • Lee, Woo-Baik;Kang, Young-Woon;Oh, Kyu-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • We present the full BVR light curves and five times of minima of WZ Cep to provides a complete photometric solution and to confirm the long term variation of the light curves. Our light curves show symmetry while previous light curves of Hoffmann (1984) show a high degree of asymmetry (the O'Connell effect). The BVR light curves were analyzed by the method of Wilson-Devinney Differential Correction. Our photometric results show a good agreement with those of Djurasevic et al. (1998).

A Study on Establishment of Reference Value of CA 72-4 (CA 72-4 참고치 설정에 관한 연구)

  • An, Jae-Seok;Kim, Ji-Na;Joe, Ye-Ji;Yoon, Sang-Hyuk;Kim, Yoon-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.25-28
    • /
    • 2021
  • Purpose CA 72-4 is a tumor marker that uses two monoclonal antibodies, CC49 and B72.3, to measure tumor-related glycoprotein(TAG72) in the serum. CA 72-4 is used to diagnose stomach, ovarian, and pancreatic cancers, and is known to perform high specificity for stomach cancer. The purpose of this study is to re-evaluate the reference value provided by the manufacturer through revalidation of the reference value in CA 72-4. Furthermore this study was conducted to provide useful help when making a clinical diagnosis at gastric cancer center. Materials and Methods We selected 271 patients who had been to health care center in national cancer center for the month of November 2020. The gender of the subjects was 140 males and 131 females, and the age group was from 30s to 60s. The reagent used in the study was a CA 72-4 IRMA KIT (ISOTOPES, Hungary) and the results were measured using a Dream Gamma-10 gamma counter (Shinjin medics, Korea). Results Statistical analysis of the results of this study used Hoffmann's method and Bayesian's method, which are primarily used in setting reference value. As a result of measuring CA 72-4 of 271 patients, the mean value was 4.54 U/mL and the median value was 3.30 U/mL. 24 people who deviated from 3SD were excluded from the measured value, the mean calculated after that was 3.53 U/mL, median was 3.00 U/mL and SD was 1.89. The reference value calculated based on this results was set to 7.31 U/mL. Conclusion The reference value provided by the manufacturer is less than 4 U/mL. It is slightly different from the value calculated in this study, 7.31 U/mL, so it seems necessary to reset the reference value according to the laboratory environment. Currently, we are receiving inquiries about the reference value from the center for gastric cancer at National Cancer Center. If additional research is carried out along with this study, it will be possible to set more accurate reference value.