• Title/Summary/Keyword: Hip

Search Result 3,128, Processing Time 0.027 seconds

Comparison of trunk muscle activity according to hip abduction angle during plank exercise

  • Pi, Tae jin;Cho, Minkwon;Shim, Suyoung;Jung, Jongchan;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.3
    • /
    • pp.162-169
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the conditions for the application of various plank exercises to people who require trunk stabilization by comparing trunk muscle activity according to the degree of hip abduction in the plank exercise. Design: Cross-sectional study. Methods: Twenty healthy participants voluntarily participated in this study and the plank exercise was performed under 5 conditions (two-legged support plank [TSP] with hip abduction, TSP with hip abduction of 15 degrees, TSP with hip abduction of 30, one-legged support plank [OSP] with hip abduction of 15 degrees, OSP with hip abduction of 30 degrees). In order to measure the trunk muscle activity according to the 5 conditions, surface electromyography was used. The electrical activities of the rectus abdominis (RA), external oblique (EO), and internal oblique (IO) muscles were measured during the 5 plank exercises. Subjects practiced each of the 5 conditions three times in random order and the average values were obtained. Results: In the OSP condition with 15/30 degrees of hip abduction, activities of the RA, EO, and IO were significantly greater than during the TSP (p<0.05). In the OSP with 30 degrees of hip abduction condition, activities of the left EO, IO were significantly greater than other plank exercise conditions (p<0.05). Conclusions: The plank exercise with hip abduction of 30 degrees and the OSP exercise can be suggested as an effective method to enhance the activity of the trunk oblique muscles.

The Effects of Contract Relaxation and a Combination of Isotonics on the Hip and Lumbopelvic Motions in Patients with Chronic Low Back Pain (만성 요통 환자에게 수축 이완과 등장성 수축 결합이 엉덩관절과 허리골반 움직임에 미치는 영향)

  • Kim, Chi-Hwan;Lee, Ju-Hun;Han, Jin-Tae
    • PNF and Movement
    • /
    • v.19 no.1
    • /
    • pp.43-55
    • /
    • 2021
  • Purpose: The purpose of this study was to determine the effects of contract relaxation and a combination of isotonics in proprioceptive neuromucular facilitation (PNF) on hip and lumbopelvic motions of male patients with chronic low back pain. Methods: As the subjects of this study, a total of 45 male patients with chronic low back pain were divided into groups: 15 who underwent contract relaxation (CR) of the PNF of their hip joints, 15 who underwent a combination of isotonics (CI) of the PNF, and 15 who underwent both techniques. A device for analyzing three-dimensional motion was used to measure hip medial rotation angles, lumbopelvic rotation angles, and hip medial rotation angles at the start of lumbopelvic rotation during hip medial rotation. A two-way repeated measures ANOVA was used to compare the average values. Results: There were interactions in the hip medial rotation angles, lumbopelvic rotation angles and hip medial rotation angles at the start of lumbopelvic rotation based on the methods and periods of exercise (p < 0.05). The CR and the CR+CI groups displayed more increased hip medial angles when compared to the CI group. The CR+CI group had more decreased lumbopelvic rotation angles when compared to the CR and the CI groups. The CR+CI group had more increased hip medial rotation angles at the start of lumbopelvic rotation when compared to the CR and the CI groups. Conclusion: It can be concluded that the combination of stretching and stability exercises was effective in male patients with chronic low back pain who showed limited hip medial rotation.

The Effects of Performing Bridge Exercise and Hip Thrust Exercise using Various Knee Joint Angles on Trunk and Lower Body Muscle Activation in Healthy Subjects

  • Kim, Dongsu;Jung, Jongchan;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.2
    • /
    • pp.205-211
    • /
    • 2021
  • Objective: This study aimed to identify the effects of assuming different knee angles and hip abduction during bridge exercise and hip thrust exercise on lower body muscle activity. Design: Cross-sectional study Methods: Thirty-three healthy adults (18 men and 15 women) were instructed to perform the bridge and hip thrust exercises while randomly assuming 120°, 90° and 60° of knee flexion and 0° and 30° of hip abduction. EMG data (%maximum voluntary isometric contraction) were recorded three times from the erector spinae (ES), gluteus maximus (GM) and biceps femoris (BF) muscles of participant's dominant side and the mean values were analyzed. Results: The results showed that, during the hip thrust compared to the bridge exercise, there was significantly greater gluteus maximus muscle activity in all hip conditions while the biceps femoris activity was significantly less, and the erector spinae muscle activity was significantly greater with 30° of hip abduction (p<0.05). With all exercises, the erector spinae and the biceps femoris exhibited significantly greater muscle activity with 60° of knee flexion compared to 90° and 120° of knee flexion (p<0.05), and significantly greater muscle activity with 90° compared to 120° of knee flexion (p<0.05). In the case of the gluteus maximus, greater muscle activity was exhibited with 120° compared to 60° of knee flexion with all hip abduction conditions (p<0.05). Conclusions: It was effective for muscle activation of main agonists such as the gluteus maximus and erector spinae during thrust exercise, and the change in knee flexion angle was effective for muscle activation of the gluteus maximus. Therefore, it is considered that this study can be used as a selective indicator of the target movement angle during hip strengthening exercise for specific muscles.

Comparison of Activity and Use of Hip Abductor Muscle Group According to Range of Motion during the Clam Exercise (클램 운동 시 운동범위에 따른 엉덩관절 벌림근의 활성도와 사용 비교)

  • Choi, Yong-Gil;Lee, Sang-Yeol;Choi, Su-Hong;Yoon, Sung-Young;Kim, In-Gyun
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.341-349
    • /
    • 2022
  • Purpose: The purpose of this study is to compare the muscle activity of the hip abductors and the ratio between the hip abductor muscle group according to the range of hip abduction during the clam exercise. Methods: This study was conducted on 18 healthy men in their aged 20 to 29 who had not been diagnosed with spine-related diseases. The subjects performed a clam exercise without rotation of the pelvis in a state of 60° hip flexion and 90° knee joint flexion in the side-lying position. Using Myomotion equipment and EMG, the muscle activity of the hip abductor muscles and the activity ratio between the hip abductor muscle group were measured during the clam exercise by dividing the range into initial, mid-range, and terminal sections. Repeated measures analysis of variants was employed to compare the activity and use of hip abductor muscles according to range of motion during the clam exercise. Results: Gluteus medius muscle activation was significantly increased in the comparison of muscle activity in the initial, mid-range, and terminal sections of hip abduction. Tensor fasciae latae muscle activation was significantly increased in the comparison of muscle activity in all range of motion sections as well. The gluteus medius-tensor fasciae latae muscle activation ratio was significantly increased in the terminal section compared to the initial section. Conclusion: The gluteus medius and tensor fasciae latae had higher muscle activities as they approached the terminal section during the clam exercise, and the hip abduction activity ratio of the gluteus medius and tensor fasciae latae was higher as the range of motion approached the terminal section.

The Effectiveness of the External Support on the Strength and Muscle Activity of Hip Abductor in Subject Without Core Stability (심부 안정성이 부족한 대상자에게 외부적 지지가 엉덩관절 벌림근의 근력과 근활성도에 미치는 영향)

  • Jeon, In-Cheol
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.64-69
    • /
    • 2022
  • Background: Gluteus medius muscle is important for the stability of hip joint. The sufficient core stability can be contributed to the performance of gluteus medius muscle in standing position. In addition, the external support may affect core stability in standing position. Objects: The purpose of this study was to investigated the effectiveness of the external support on the strength and muscle activity of hip abductor muscle during hip abduction in standing position in subjects without core stability. Methods: Fifteen subjects participated in this study. The subjects were evaluated by using the double-leg lowering with bent knees to measure the core stability. The strength and muscle activity of hip abductors was measured in standing position with the condition with and without external support using the tensiometer sensor and the surface electromyography. The paired t-test was used to investigate the difference between hip abductor strength and activity according to external support. The level of statistical significance was set at α = 0.05. Results: The hip abductor strength and muscle activity of gluteus medius muscle with external support were significantly greater than those without external support during hip abduction in standing position (p < 0.05). Conclusion: During hip abduction in standing position, the external support may be contributed to the improvement of the hip abductor strength and muscle activity of gluteus medius especially in the subjects without core stability.

Contact Stress Analysis of Artificial Hip Joints Using Finite Element Method (유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구)

  • Kim, Chung-Kyun;Yoon, Jong-Deok
    • Tribology and Lubricants
    • /
    • v.13 no.1
    • /
    • pp.82-87
    • /
    • 1997
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires a re-replacement of hip joints because it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focussed on the development of new materials. The research of new materials, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find new combinations of bio-materials in the total hip replacement which has the excellent contact characteristics. A non-linear FEM program MARC with 5-node axisymmetric element was used for analyzing the contact stresses between the hip joints. The computed results show that in case of acetabulum UHMWP has good characteristics, in femoral head, $Al_2O_3$, and in stem, Ti6Al4V.

Squeak Noise of Ceramic-on-ceramic Hip Joint using FEM (FEM을 이용한 세라믹-세라믹 고관절 마찰소음의 불안정성 해석에 관한 연구)

  • Nam, Jaehyun;Kang, Jaeyoung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.12
    • /
    • pp.1090-1095
    • /
    • 2013
  • This paper describes the FEM analysis for squeak problem of the ceramic-on-ceramic hip joint system. The onset of hip squeak is estimated by the positive real parts of the eigenvalues in the hip joint system. From the complex eigenvalue analysis, the unstable frequencies and the corresponding mode shapes are determined at the certain severe friction coefficients. It is found that some bending and torsion modes of the femoral stem can be unstable due to the mode-coupling mechanism. It also shows that the magnitude of the friction coefficient plays a key role on the occurrence of hip squeak.

Properties of Y-Ba-Cu-O High Tc superconductor prepared by sintering, sintering+HIP encapsulation (열간 정수압 소결(HIP)에 의한 Y-Ba-Cu-O계rhdhs 초전도체의 제작 및 특성)

  • 김종문;백수현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.10a
    • /
    • pp.36-40
    • /
    • 1988
  • High TC Y-Ba-Cu-O Superconductors were fabricated by sintering, sinter+HIP encapsulation. Specimens were sintered at 920$^{\circ}C$∼960$^{\circ}C$. A part of sintered specimens were treated by HIP, and HIP conditions were 150 MPa, 880$^{\circ}C$, 30min under the Ar atmosphere. The relative density of HIP specimens was increased 5∼8% in comparison with sintered one(90∼93% relative density). X-ray analysis represented the orthorhobic-tetragonal phase transition with annealing condition. Tc measurements showed a sharp drp within 3$^{\circ}C$, 91K onset and 89K offset. Transport current density(Jc) of sintered specimens showed typically∼159A/㎤ but that of sinter+HIP encapsulation was decreased to∼89A/㎤ because of insufficient oxygen diffusion, Hardness(H) and Toughness(Kc) were increased to 38GPa; and 2.9 MPam$\^$$\frac{1}{2}$/, respectively.

  • PDF

Development of Hip Joint Simulator to Evaluate The Wear of Biomaterials Used in Total Hip Joint Replacement (인공고관절 생체재료 마멸평가를 위한 시뮬레이터 개발)

  • 이권용;윤재웅;전승범;박성길
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.265-270
    • /
    • 2001
  • Hip joint simulator which Is an essential device for evaluating the wear of biomaterials (ultrahigh molecular weight polyethylene, Co-Cr alloy, alumina, etc.) used in total hip joint replacement was developed. This hip joint simulator mimics the joint motion and joint loading of human gait by adapting the 4 degree of freedom in kinematic motion (flexing/extension, adduction/abduction, Internal rotation/external rotation) and axial loading, Four stations are operated by 8 servo-motors and harmony drives. Joint leading was imposed by displacement control from a ball screw, LM guide, and spring system. Each kinematic link system operates separately or coupled modes. A heater and a thermocouple were installed for keeping the body temperature in each station.

  • PDF

Reduction of the Femoral Head First, and Assembly of the MUTARS® Device in Case of Impossible Reduction during Total Hip Arthroplasty

  • Jee Young Lee;Ye Jun Lee;Gyu Min Kong
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.277-280
    • /
    • 2023
  • Dislocation after a total hip arthroplasty occurs in approximately 1% of patients; however, the frequency is much higher after revision surgery. To prevent dislocation, use of a larger femoral head is recommended, and a dual mobility femoral head has been introduced. However, reducing the dual mobility femoral head to the acetabular component is difficult in cases involving contracture in the soft tissue around the joint. A 72-year-old male patient who developed a periprosthetic joint infection underwent two-stage revision surgery using MUTARS®. Two months after the revision, the hip joint became dislocated and manual reduction was attempted; however, dislocation occurred again. During another revision using a dual mobility bearing, the soft tissue around the hip joint was too tight to reduce. The problem was overcome by first repositioning the dual mobility head into the acetabular socket, followed by assembly of the diaphyseal portion of the implant.