1 |
Sariali, E., Stewart, T., Jin, Z. and Fisher, J., 2009, In vitro Investigation of Friction under Edge Loading Conditions for Ceramic-on-ceramic total Hip Prosthesis, Journal of Orthopaedic Research, Vol. 28, No. 8, pp. 979-985.
|
2 |
Currier, J., Anderson, D. and Van Citters, D., 2010, A Proposed Mechanism for Squeaking of Ceramic-on-ceramic Hips, Wear, Vol. 28, No. 8, pp. 979-985.
|
3 |
Meziane, A., Baillet, L. and Laulagnet, B., 2010, Experimental and Numerical Investigation of Friction-induced Vibration of a Beam-on-beam in Contact with Friction, Applied Acoustics, Vol. 71, No. 9, pp. 843-853.
DOI
ScienceOn
|
4 |
Ghazaly, N., Mohammed, S. and Abd-El-Tawwab, A., 2012, Understanding Mode-coupling Mechanism of Brake Squeal Using Finite Element Analysis, International Journal of Engineering Research and Application, Vol. 2, No. 1, pp. 241-250.
|
5 |
Pyburn, E. and Goswami, T., 2003, Finite Element Analysis of Femoral Components Paper III Hip Joints, Materials & Design, Vol. 25, No. 8, pp. 705-713.
|
6 |
Kang, J., 2012, Finite Element Modeling for the Investigation of In-plane Modes and Damping Shims in Disc Squeal, Journal of Sound and Vibration, Vol. 331, No. 9, pp. 2190-2202.
DOI
ScienceOn
|
7 |
Kang, J., 2009, Squeal Analysis of Gyroscopic Disc Brake System based on Finite Element Method, International Journal of Mechanical Science, Vol. 51, No. 4, pp. 284-294.
DOI
ScienceOn
|
8 |
Nam, J. and Kang, J., 2012, Unstable Brake Pad Mode due to Friction-velocity Slope, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 22, No. 12, pp. 1206-1212.
과학기술학회마을
DOI
ScienceOn
|
9 |
Higuchi, F., Shiba, N., Inoue, A. and Wakebe, I., 1995, Fracture of an Alumina Ceramic Head in Total Hip Arthroplasty, Journal of Arthoplasty, Vol. 10, No. 6, pp. 854-854.
|
10 |
Han, S., Chu, J., Song, K., Park, S., Choi, J., Kim, J., Suh, J., Choi, K. and Youn, I., 2012, Prediction of Stress Distribution in the Ceramic Femoral Head After Total Hip Replacement, Journal of the Korean Society for Precision Engineering, Vol. 29, No. 29, pp. 680-685.
과학기술학회마을
DOI
ScienceOn
|
11 |
Kim, D., Ki, S., Park, K., Kim, Y. and Chung, Y., 2008, Total Hip Arthroplasty Using a Ceramic on Ceramic Bearing Surfaces, Journal of Korean Orthopaedic Association, Vol. 43, No. 4, pp. 495-500.
과학기술학회마을
DOI
ScienceOn
|
12 |
Fan, N. and Chen, G., 2012, Numerical Study of Squeaking Suppresses for Ceramic-on-ceramic Hip Endoprosthesis, Tribology International, Vol. 48, pp. 172-181.
DOI
ScienceOn
|
13 |
Weiss, C., Gdaniec, P., Hoffman, N., Hothan, A., Huber, G. and Morlock, M., 2010, Squeak in Hip Endoprosthesis Systems: An Experimentalstudy and a Numerical Technique to Analyze Design Variants, Medical Engineering & Physics, Vol. 32, No. 6, pp. 604-609.
DOI
ScienceOn
|