• Title/Summary/Keyword: Higher Heating Value

Search Result 342, Processing Time 0.025 seconds

Characterization of a Korean Domestic Cyanobacterium Limnothrix sp. KNUA012 for Biofuel Feedstock (토착 남세균 림노트릭스 속 KNUA012 균주의 바이오연료 원료로서의 특성 연구)

  • Hong, Ji Won;Jo, Seung-Woo;Kim, Oh Hong;Jeong, Mi Rang;Kim, Hyeon;Park, Kyung Mok;Lee, Kyoung In;Yoon, Ho-Sung
    • Journal of Life Science
    • /
    • v.26 no.4
    • /
    • pp.460-467
    • /
    • 2016
  • A filamentous cyanobacterium, Limnothrix sp. KNUA012, was axenically isolated from a freshwater bloom sample in Lake Hapcheon, Hapcheon-gun, Gyeongsangnam-do, Korea. Its morphological and molecular characteristics led to identification of the isolate as a member of the genus Limnothrix. Maximal growth was attained when the culture was incubated at 25℃. Analysis of its lipid composition revealed that strain KNUA012 could autotrophically synthesize alkanes, such as pentadecane (C15H32) and heptadecane (C17H36), which can be directly used as fuel without requiring a transesterification step. Two genes involved in alkane biosynthesis-an acyl-acyl carrier protein reductase and an aldehyde decarbonylase-were present in this cyanobacterium. Some common algal biodiesel constituents-myristoleic acid (C14:1), palmitic acid (C16:0), and palmitoleic acid (C16:1)-were produced by strain KNUA012 as its major fatty acids. A proximate analysis showed that the volatile matter content was 86.0% and an ultimate analysis indicated that the higher heating value was 19.8 MJ kg−1. The isolate also autotrophically produced 21.4 mg g−1 phycocyanin-a high-value antioxidant compound. Therefore, Limnothrix sp. KNUA012 appears to show promise for application in cost-effective production of microalga-based biofuels and biomass feedstock over crop plants.

Preparation and Characterization of Jochung, a Grain Syrup, with Apple (사과 첨가 조청의 제조 및 특성)

  • Yang, Hye-Jin;Ryu, Gi-Hyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.1
    • /
    • pp.132-137
    • /
    • 2010
  • This study was performed to investigate the effect of apple and maltitol as ingredients on the quality of Jochung, a grain syrup. Four kinds of Jochung products were prepared from steamed-rice, apple juice, heated-apple sarcocarp (at $70^{\circ}C$, 60 min), and a mixture (sarcocarp : maltitol=5:1, w/w) by saccharifying (at $55^{\circ}C$, 8 hrs) with a malt (100 g/500 g rice), mixing the ingredients (steamed-rice : ingredient=5:5, w/w), filtering, and heating the filtrate (at $95^{\circ}C$, 2 hrs): product (A) with apple juice added before saccharified, product (B) with apple juice added after saccharified, product (C) with heated-apple sarcocarp added after saccharified, and product (D) with the mixture added after saccharified. The product (D) had the lowest pH value ($4.60\pm0.01$) of any other products. The contents of reducing sugar and total phenolic compound were the highest in the product (A) among all the products, which comprised $68.10\pm6.71$% and $7.36\pm0.85$ mg/g, respectively, resulting in good quality. The solidity and the dextrose equivalence had the highest value in the product (B) and the product (C), respectively. The malic acid content ($4.10\pm0.02$%) of the product (D) was the highest of any other organic acids identified by HPLC. Hunter L, a, and b values of the product (D) were the highest compared to other products. In sensory evaluation, the product (A) had generally higher score in all sensory attributes. It was concluded from the chemical and sensory evaluation that adding the apple juice before saccharified might be an effective method for manufacturing good quality rice-Jochung.

Larch Pellets Fabricated with Coffee Waste and the Commercializing Potential of the Pellets (커피박과 낙엽송 목분을 이용한 펠릿 제조 및 이에 대한 상용화 검토)

  • Yang, In;Han, Gyu Seong;Oh, Seung Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.48-59
    • /
    • 2018
  • This study was conducted to suggest the effective management and recycling processes of coffee waste, which can be easily obtained from coffee shops and coffee-related products industries. Prior to the fabrication of pellets, the potential of coffee waste as a raw material of pellet was investigated through the examination of its chemical compositions and fuel characteristics. Major gradient included in coffee waste was holocellulose, followed by fat/oil and protein. Coffee waste contained a small quantity of ash (0.7%), such as calcium, sodium, potassium and magnesium. Interestingly, coffee waste was easily dried probably due to its porous structure. Pellets fabricated with coffee waste and larch sawdust showed good fuel characteristics, such as moisture content, ash content, density and durability. The pellets exceed greatly the minimum requirements of $1^{st}$-grade wood pellet standard designated by National Institute of Forest Science (NIFOS). Particularly, the high calorific value of coffee waste showed the potential as a raw material of pellet. However, owing to high nitrogen and sulfur contents, coffee waste is like to be used as a raw material of wood pellet for combined heat and power plants equipped with a reduction system of $NO_x$ and $SO_x$ gases. On the other hand, 91 wt% larch sawdust and 9 wt% coffee waste are required to fabricate the $1^{st}$-grade wood pellets designated by NIFOS. Pellets fabricated with the conditions are estimated to have nitrogen content of 0.298% and sulfur content of 0.03%. Lastly, if amounts of coffee waste and sawdust in the production of wood pellets are adequately adjusted according to its purchasing price, the manufacturing cost of pellet can effectively be reduced. In addition, it is expected tp prepare the effective recycling process of waste and to relieve the environmental burden with the reduction of waste from the commercialization of coffee waste/larch pellets.

Assessment of Sensory and Safety Evaluation of Cook/Chill Pajeon (Cook-chill 파전의 관능성 및 안전성 평가)

  • Lyu, Eun-Soon;Jeong, Dong-Kwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.5
    • /
    • pp.674-680
    • /
    • 2005
  • The purposes of this study were to compare the effect of several reheating treatments (heating in the frying pan, convection oven and microwave oven) on sensory characteristics and to evaluate the safety during storage period of cook/chill Pajeon. The sensory evaluations were made on 5 sensory attributes by a 9-member panel using quantitative descriptive analysis (QDA). The fresh cooked Pajeon and the Pajeon reheated in the frying pan obtained a significantly (p<0.01) higher score in taste than the ones reheated in a convection oven and microwave oven. The reheated cook/chill Pajeon had a significantly (p<0.01) lower score in flavor than the freshed cooked one. Regardless of the reheating methods, sensory scores in texture of the Pajeon reheated at $v$ for 1 day were not different from that of fresh cooked one. However, the scores of the reheated ones in a convection oven and in a microwave oven decreased with storage time up to 5 days at $3^{\circ}C$. On the other hand, the Pajeon reheated in the frying pan, even after 3 days' storage at $3^{\circ}C$, was not found to be inferior to the freshed cook one in every quality attributes except flavor. Therefore, the reheating treatment in frying pan may be superior to those in a convection oven and a microwave oven. The safety of Pajeon was also evaluated by measuring total count, coliform count, psychrotrophic count, acid value and peroxide value during 5 days of storage periods at $4^{\circ}C$. Total counts of Pajeon was ranged from not detectable to $5.2\times10^2$ CFU/g. The coliform and psychrotroph were not detected at all experiments. The acid values were ranged from 1.90 to 4.03 mg of KOH/g of fat until 5 days at $4^{\circ}C$. And the peroxide values were ranged from 3.63 to 12.50 meq of peroxide/kg of fat until 5 days of storage period. Therefore, these results demonstrated that Pajeon is microbiologically and chemically safe during 5 days of storage period at refligeration temperature.

Physicochemical Characteristics and Antioxidant Activity of Heated Radish (Raphanus sativus L.) Extracts (열처리 무 추출물의 이화학적 특성과 항산화 활성)

  • Lee, Sang-Hoon;Hwang, In-Guk;Lee, Youn-Ri;Joung, Eun-Mi;Jeong, Heon-Sang;Lee, Hee-Bong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.4
    • /
    • pp.490-495
    • /
    • 2009
  • This study investigated the changes of physicochemical characteristics and antioxidant activity of heated radish (Raphanus sativus L.). Raw radish was heated at various temperatures ($110{\sim}150^{\circ}C$) for 2 hr. The heated radish was extracted with 70% ethanol and then fractionated with hexane, ethyl acetate, and aqueous. Total polyphenol contents, $IC_{50}$ value of electron donating ability (EDA), and total antioxidant activity (AEAC) increased with increasing heating temperature. The maximum total polyphenol content was $256.26{\pm}9.61$ mg/100 g at $150^{\circ}C$ (control: $27.90{\pm}1.28$ mg/100 g), $IC_{50}$ value was $1.34{\pm}0.004$ mg/mL at $150^{\circ}C$ (control: $34.93{\pm}0.039$ mg/mL), and AEAC was $53.10{\pm}1.155$ mg AA eq/g at $150^{\circ}C$ (control: $6.721{\pm}0.122$ mg AA eq/g). The ethyl acetate fraction showed higher total polyphenol contents and stronger antioxidant activities than hexane and aqueous fractions. Total polyphenol content was 133.62 mg/100 g (at $140^{\circ}C$), $IC_{50}$ values of EDA and AEAC content were 0.39 mg/mL (at $150^{\circ}C$) and 183.72 mg AA eq/g (at $140^{\circ}C$), respectively.

Coupled T-H-M Processes Calculations in KENTEX Facility Used for Validation Test of a HLW Disposal System (고준위 방사성 폐기물 처분 시스템 실증 실험용 KENTEX 장치에서의 열-수리-역학 연동현상 해석)

  • Park Jeong-Hwa;Lee Jae-Owan;Kwon Sang-Ki;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.117-131
    • /
    • 2006
  • A coupled T-H-M(Thermo-Hydro-Mechanical) analysis was carried out for KENTEX (KAERI Engineering-scale T-H-M Experiment for Engineered Barrier System), which is a facility for validating the coupled T-H-M behavior in the engineered barrier system of the Korean reference HLW(high-level waste) disposal system. The changes of temperature, water saturation, and stress were estimated based on the coupled T-H-M analysis, and the influence of the types of mechanical constitutive material laws was investigated by using elastic model, poroelastic model, and poroelastic-plastic model. The analysis was done using ABAQUS, which is a commercial finite element code for general purposes. From the analysis, it was observed that the temperature in the bentonite increased sharply for a couple of days after heating the heater and then slowly increased to a constant value. The temperatures at all locations were nearly at a steady state after about 37.5 days. In the steady state, the temperature was maintained at $90^{\circ}C$ at the interface between the heater and the bentonite and at about $70^{\circ}C$ at the interface between the bentonite and the confining cylinder. The variation of the water saturation with time in bentonite was almost same independent of the material laws used in the coupled T-H-M processes. By comparing the saturation change of T-H-M and that of H-M(Hydro-Mechanical) processes using elastic and poroelastic material mod31 respectively, it was found that the degree of saturation near the heater from T-H-M calculation was higher than that from the coupled H-M calculation mainly because of the thermal flux, which seemed to speed up the saturation. The stresses in three cases with different material laws were increased with time. By comparing the stress change in H-M calculation using poroelasetic and poroelasetic-plastic model, it was possible to conclude that the influence of saturation on the stress change is higher than the influence of temperature. It is, therefore, recommended to use a material law, which can model the elastic-plastic behavior of buffer, since the coupled T-H-M processes in buffer is affected by the variation of void ratio, thermal expansion, as well as swelling pressure.

  • PDF

Separation of Reducing Sugars from Rape Stalk by Acid Hydrolysis and Fabrication of Fuel Pellets from its Residues (산가수분해한 유채대로부터 유리당의 분리 및 이의 잔사로부터 펠릿의 제조)

  • Yang, In;Ahn, Byoung Jun;Kim, Myeong-Yong;Oh, Sei Chang;Ahn, Sye Hee;Choi, In-Gyu;Kim, Yong-Hyun;Han, Gyu-Seong
    • Korean Journal of Plant Resources
    • /
    • v.27 no.1
    • /
    • pp.60-71
    • /
    • 2014
  • This study was conducted to identify the potential of rape stalk as a raw material for biorefinery process of rape flower. At first, rape stalk (RS) was immersed in distilled water (DW), acetic acid (AA), oxalic acid (OA), sulfuric acid (SA) and sodium hydroxide (SH) solutions, and the content of reducing sugars liberated from immersed RS was analyzed. Glucose, xylose, arabinose and sucrose were detected varying with the immersion type. In particular, 1% AA-immersion of RS for 72 hr was the most effective conditions to liberate glucose from RS. Secondly, the RS residues were used for elementary analysis and fabrication of fuel pellets. In addition to the solution type, concentration of immersion solutions (0%, 1%, 2%) and immersion time (24, 72, 120 hr) were used as experimental factors. The contents of nitrogen, sulfur and chlorine reduced effectively through the immersion of RS in DW, AA and OA solutions. For properties of RS-based pellets, bulk density and higher heating value of RS-based pellets greatly increased with the immersion of RS, and the qualities were much higher than those of the A-grade pellet of the EN standards. Ash content decreased remarkably through the immersion of RS, and was satisfied with the A-grade pellet standard. Durability was negatively affected by the immersion of RS, and did not reached to B-grade of the EN standard. In conclusion, acid immersion of RS can be a pretreatment method for the production of fuel pellet and bioethanol, but use of the immersed RS for the production of high-quality pellets might be restricted due to low durability of immersed-RS pellets. Therefore, further studies, such as investigation of detailed immersion conditions, fabrication of mixed pellets with wooden materials and addition of binders, are needed to resolve the problems.

Analysis of Heat Transfer Characteristics on Multi-layer Insulating Curtains Coated with Silica Aerogel (실리카 에어로겔이 흡착된 다겹보온커튼의 전열 특성 분석)

  • Jin, Byung-Ok;Kim, Hyung-Kweon;Ryou, Young-Sun;Lee, Tae-Seok;Kim, Young-Hwa;Oh, Sung-Sik;Kang, Geum-Choon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.273-278
    • /
    • 2019
  • The multi-layer insulating curtains used in the experiment was produced in six combinations using non-woven fabric containing aerogel and compared and analyzed by measuring heat flux and heat perfusion rates due to weight, thickness and temperature changes. Using silica aerogel, which have recently been noted as new material insulation, this study tries to produce a new combination of multi-layer insulating curtains that can complement the shortcomings of the multi-layer insulating curtains currently in use and maintain and improve its warmth, and analyze the thermal properties. The heat flux means the amount of heat passing per unit time per unit area, and the higher the value, the more heat passing through the multi-layer insulating curtain, and it can be judged that the heat retention is low. The weight and thickness of multi-layer insulation curtains were found to be highly correlated with thermal insulation. In particular, insulation curtains combined with aerogel meltblown non-woven fabric had relatively higher thermal insulation than insulation curtains with the same number of insulation materials. However, the aerogel meltblown non-woven fabric is weak in light resistance and durability, and there is a problem that the production process and aerogel are scattering. In order to solve this problems, the combination of expanded aerogel non-woven fabric and hollow fiber non-woven fabric, which are relatively simple manufacturing processes and excellent warmth, are suitable for use in real farms.

Summer-Time Behaviour and Flux of Suspended Sediments at the Entrance to Semi-Closed Hampyung Bay, Southwestern Coast of Korea (만 입구에서 부유퇴적물 거동과 플럭스: 한반도 서해 남부 함평만의 여름철 특성)

  • Lee, Hee-Jun;Park, Eun-Sun;Lee, Yeon-Gyu;Jeong, Kap-Sik;Chu, Yong-Shik
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.2
    • /
    • pp.105-118
    • /
    • 2000
  • Anchored measurements (12.5 hr) of suspended sediment concentration and other hydrodynamic parameters were carried out at two stations located at the entrance to Hampyung Bay in summer (August 1999). Tidal variations in water temperature and salinity were in the range of 26.0-27.9$^{\circ}C$ and 30.9-31.5, respectively, indicating exchange offshore and offshore water mass. Active tidal mixing processes at the entrance appear to destroy the otherwise vertical stratification in temperature and salinity in spite of strong solar heating in summer. On the contrary, suspended sediment concentrations show a marked stratification with increasing concentrations toward bottom layer. Clastic particles in suspended sediments consist mostly of very fine to fine silt (4-16 ${\mu}$m) with a poorly-sorted value of 14.7-25.9 ${\mu}$m. However, at slack time with less turbulent energy, flocs larger than 40 ${\mu}$m are formed by cohesion and inter-collision of particles, resulting in a higher settling velocity. Strong ebb-dominated and weak flood dominated tidal currents, in the southwestern and the northeastern part, respectively, result in a seaward residual flow of -10${\sim}$-20 cm $s^{-1}$ at station H1 and a bayward residual flow less than 5.0 cm $s^{-1}$ at station H2. However, mean concentration of suspended sediments at station H1 is higher at flood (95.0-144.1 mg $1^{-1}$) than in ebb (75.8-120.9 mg $1^{-1}$). On the contrary, at the station H2, the trend is reversed with higher concentration at the ebb (84.7-158.4 mg $1^{-1}$) than that at the flood (53.0-107.9 mg $1^{-1}$). As a result, seaward net suspended sediment fluxes ($f_{s}$) are calculated to be -1.7 ${\sim}$-$15.610^{3}$ kg $m^{-2}$ $s^{-1}$ through the whole water column. However, the stations H1 and H2 show definitely different values of the flux with higher ones in the former than in the latter. Alternatively, depth-integrated net suspended sediment loads ($\c{Q}_{s}$) for one tidal cycle are also toward the offshore with ranges of 0.37${\times}$$10^{3}$ kg $m^{-1}$ and 0.21${\times}$$10^{3}$ kg $m^{-1}$, at station H1 and H2, respectively. This seaward transport of suspended sediment in summer suggests that summer-time erosion in the Hampyung muddy tidal flats is a rather exceptional phenomenon compared to the general deposition reported for many other tidal flats on the west coast of Korea.

  • PDF

Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture (시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석)

  • Ryou, Young-Sun;Kang, Youn-Ku;Kang, Geum-Chun;Kim, Young-Joong;Paek, Yee
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.90-95
    • /
    • 2008
  • It has become a big matter of concerns that the skill and measures against reduction of energy and cost for heating a protected horticultural greenhouse were prepared. But in these days necessity of cooling a protected horticultural greenhouse is on the rise from partial high value added farm products. In this study, therefore, a horizontal type geothermal heat pump system with 10 RT scale to heat and cool a protected horticultural greenhouse and be considered to be cheaper than a vertical type geothermal heat pump system was installed in greenhouse with area of $240\;m^2$. And cooling performances of this system were analysed. As condenser outlet temperature of heat transfer medium fluid rose from $40^{\circ}C$ to $58^{\circ}C$, power consumption of the heat pump was an upturn from 11.5 kW to 15 kW and high pressure rose from 1,617 kPa to 2,450 kPa. Cooling COP had the trend that the higher the ground temperature at 1.75 m went, the lower the COP went. The COP was 2.7 at ground temperature at 1.75 m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$ and the heat extraction rate from the greenhouse were 28.8 kW, 26.5 kW respectively at the same ground temperature range. 8 hours after the heat pump was operated, the temperature of ground at 60 cm and 150 cm depth buried a geothermal heat exchanger rose $14.3^{\circ}C$, $15.3^{\circ}C$ respectively, but the temperature of ground at the same depth not buried rose $2.4^{\circ}C$, $4.3^{\circ}C$ respectively. The temperature of heat transfer medium fluid fell $7.5^{\circ}C$ after the fluid passed through geothermal heat exchanger and the fluid rejected average 46 kW to the 1.5 m depth ground. It analyzed the geothermal heat exchanger rejected average 36.8 W/m of the geothermal heat exchanger. Fan coil units in the greenhouse extracted average 28.2 kW from the greenhouse air and the temperature of heat transfer medium fluid rose $4.2^{\circ}C$after the fluid passing through fan coil units. It was analyzed the accumulation energy of thermal storage thank was 321 MJ in 3 hours and the rejection energy of the tank was 313 MJ in 4 hours.