• Title/Summary/Keyword: High-voltage pulse power

Search Result 623, Processing Time 0.026 seconds

High Efficiency Triple Mode Boost DC-DC Converter Using Pulse-Width Modulation (펄스폭 변조를 이용한 고효율 삼중 모드 부스트 변환기)

  • Lee, Seunghyeong;Han, Sangwoo;Kim, Jongsun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.89-96
    • /
    • 2015
  • This paper presents a high efficiency, PSM/DCM/CCM triple mode boost DC-DC converter for mobile application. This device operates at Pulse-Skipping Mode(PSM) when it enters light load, and otherwise operate the operating frequency of 1.4MHz with Pulse-Width Modulation(PWM) mode. Especially in order to improve the efficiency during the Discontinuous-Conduction Mode(DCM) operation period, the reverse current prevention circuit and oscillations caused by the inductor and the parasitic capacitor to prevent the Ringing killer circuit is added. The input voltage of the boost converter ranges from 2.5V ~ 4.2V and it generates the output of 4.8V. The measurement results show that the boost converter provides a peak efficiency of 92% on CCM and 87% on DCM. And an efficiency-improving PWM operation raises the efficiency drop because of transition from PWM to PFM. The converter has been fabricated with a 0.18um Dongbu BCDMOS technology.

Digitally Controlled Single-inductor Multiple-output Synchronous DC-DC Boost Converter with Smooth Loop Handover Using 55 nm Process

  • Hayder, Abbas Syed;Park, Young-Jun;Kim, SangYun;Pu, Young-Gun;Yoo, Sang-Sun;Yang, Youngoo;Lee, Minjae;Hwang, Keum Choel;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.821-834
    • /
    • 2017
  • This paper reports on a single-inductor multiple-output step-up converter with digital control. A systematic analog-to-digital-controller design is explained. The number of digital blocks in the feedback path of the proposed converter has been decreased. The simpler digital pulse-width modulation (DPWM) architecture is then utilized to reduce the power consumption. This architecture has several advantages because counters and a complex digital design are not required. An initially designed unit-delay cell is adopted recursively for the construction of coarse, intermediate, and fine delay blocks. A digital limiter is then designed to allow only useful code for the DPWM. The input voltage is 1.8 V, whereas output voltages are 2 V and 2.2 V. A co-simulation was also conducted utilizing PowerSim and Matlab/Simulink, whereby the 55 nm process was employed in the experimental results to evaluate the performance of the architecture.

Characteristics of Ultrasonic Signals Caused by Corona Discharge in Air (코로나방전에 의한 공중(空中)초음파 신호 특성)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.38-46
    • /
    • 1999
  • Measurerments of ultrasonic signals caused by corona discharges were perforrred by using an ultrasonic meeasurerment technique to analyze the deve1qxrent states of coronas in a high-voltage power apparatus. We also examined the relationship between discharge magnitude and ultrasonic pulse number to diagnose the deterioration of electrical insulation by corona discharges. From these results, it was found that ultrasonic signals due to corona discharges can be firstly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of ultrasonic signals was closely related to the current pulses by the corona discharges when ac voltages were gradually raised, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, tirre-delaying and directivity charocteristics of ultrasonic signals propagated to air by using ultrasonic oscillation and receiving systems are feJXlrt.ed as a basic data of ultrasonic measurements in out-door HV apparatus.aratus.

  • PDF

Special quality research about action output waveform change by gap (1.0mm and 1.6mm)difference of skin excessive expense $CO_2$ Laser (피부과용$CO_2$ 레이저의 공극(1.0mm및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성 연구)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Study on Noise Reduction of Plasma Display Panel (플라즈마 디스플레이의 소음 저감 연구)

  • Park, Dae-Kyong;Kweon, Hae-Sub;Jang, Dong-Seob
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.693-698
    • /
    • 2002
  • For the evaluation of the plasma display panel (PDP)'s noise, vibration and sound characteristics of fanless PDP are measured and investigated. PDP is a type of two-electrode vacuum tube which operates on the same principle as a household fluorescent light. An inert gas such as argon or neon is injected between two glass plates on which transparent electrodes have been formed, and the glass is illuminated by generating discharge. For this discharge, both high voltage and currents are needed and cause an acoustic noise. We investigated the noise characteristics connected with both a electromagnetic elements from SMPS to panel through X, Y and logic board, and a mechanical elements form panel to case through transfer path which related with vibration and heat. To reduce the noise of PDP, a discharge pulse memory design related with both higher brightness and lower power consumption is important and mechanical characteristics connected with dissipation process of both heat and vibration generated by panel discharge must be investigated.

  • PDF

A Study on the Real Features of Harmonic Obstacle (고조파 장해의 진상에 관한 연구)

  • 이해기
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.162-171
    • /
    • 1998
  • This paper presents the harmonics obstacle analysis and countermeasure of electrical consumption a place. Harmonics that can be cosidered as a environmental pollution of the power systems become the cause of the accidents and damages. The responsibility of eliminating the harmonics firstly lies on the generating side. But the original characteristics of the system sush as the harmonic transfer characteristics and the impedance of the system affect each other in the process of the generation and transmission of the harmonic. Therefore it is very difficult to specify clearly the harmonic controlling responsibility, because electric machinery generating harmonics are various in the industrial fields. The output of a inverter has a high harmonic content. There are several ways of minimizing the output harmonic content. One way is to use pulse width modulation techniques within inverter. An alternative method is to combine a number of square-wave inverters. In this research, we measure the harmonic of the countermeasure of electrical consumption a place. The paper present the problem of new harmonic elimination method of PWM inverter fed induction motor system using W-FT series. In the future, the proposed PWM pattern by W-FT series is effective not only to the induction motor but also to the electromagnetic machine such as voltage reglator, UPS.

  • PDF

Real-time Gap Control for Micro-EDM: Application in a Microfactory

  • Jung, Jae-Won;Ko, Seok-Hoon;Jeong, Young-Hun;Min, Byung-Kwon;Lee, Sang-Jo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.3-6
    • /
    • 2008
  • Electrical discharge machining (EDM) is one of the most widespread nonconventional machining processes. Recently, a low-power micro-EDM process was introduced using a cylindrical electrode. Since its development, micro-EDM has been applied effectively to micromachining, and because the device setup for this process is simple, it is suitable for a microfactory that minimizes machines to fabricate small products economically in one system. In the EDM process, however, the electrode is also removed along with the workpiece. Therefore, the electrode shape and length vary as machining progresses. In this paper, a control method using a high speed realtime voltage measurement is proposed to regulate the rate and amount of material removed. The proposed method is based on the assumption that the volume of the workpiece removed in a single discharge pulses is nearly constant. The discharge pulses are monitored and controlled to regulate the amount of material removed. For this purpose, we developed an algorithm and apparatus for counting the number of discharge pulses. Electrode wear compensation using pulse number information was applied to EDM milling in a microfactory, in which a slight tilt of the workpiece may occur. The proposed control method improves the machining quality and efficiency by eliminating the inaccuracies caused by electrode wear and workpiece tilt.

유도 결합형 플라즈마내의 이온 존재비율 측정에 관한 연구

  • 조정희;한승희;이연희;김영우;임현의;서무진;김곤호;김옥경
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.219-219
    • /
    • 1999
  • 플라즈마 이온 주입은 진공 chamber 내에 주입하려는 이온이 포함된 플라즈마를 발생시킨 후 처리하고자 하는 시편에 negative high voltage pulse를 인가함으로써 시편 주위에 형성되어 있는 이온들을 시편에 주입하는 방법이다. 이러한 플라즈마 이온 주입 방법은 금속의 내마모성, 내부식성, 강도 및 경도를 증가시키고, 고분자 화합물의 표면 개질에 있어서 친수성 또는 소수성과 같은 표면 처리를 쉽고 간단하게 처리할 수 있다. 그리고 반도체 공정의 shallow junction doping을 효과적으로 처리할 수 있으며 특히, 대면적의 시편에 균일하게 이온을 주입할 수 있다. 플라즈마 이온 주입 방법에서 중요한 요소는 dose, 즉 이온 주입한 양과 처리하려는 시편에 주입되는 이온의 에너지이다. 여기서, 플라즈마내에 생성된 이온들의 비율을 정확히 안다면 시편에 주입되는 이온의 양과 주입되는 이온의 에너지를 충분히 예견할 수 있다. 질소 플라즈마의 경우에는 N+와 N2+가 생성되므로, 시편에 주입된 질소 이온의 실질적인 이온당 질소 원자수는 1$\times$N+% + 2$\times$N+%가 되고, N2+의 경우는 N+ 주입 에너지의 1/2 로 시편내에 주입되게 된다. 또한 질소 플라즈마의 경우 N2+ 이온이 상대적으로 N+이온보다 많다면 N+가 많은 경우보다 이온 주입 깊이는 얕아지게 된다. 본 실험에서는 Dycor M-100 residual gas analyzer와 potical emission spectrometer (Ocean Optics SQ 2000)를 사용하여 압력과 RF power를 변화시키며 플라즈마내에 생성되어지는 질소 이온의 비율을 측정하였다. 또한 Langmuir probe를 이용하여 속도차에 의한 각 이온들의 존재비율을 계산하였다. 여기에서 질소 가스의 압력이 낮을수록 N+보다 N2+의 존재비율이 높음을 보였다. 이것은 압력이 낮은 영역에서 일반적으로 전자의 평균온도가 높기 때문으로 여겨진다.

  • PDF

A High Efficiency Electrolytic Cell by Superposing Pulsed Corona Discharge in Water (수중 펄스코로나 방전을 중첩한 고효율 강전해수 발생장치)

  • 이재용;김진규;정성진;박승록;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.79-85
    • /
    • 2001
  • A conventional electrolyzing cell has been made by an ion exchange membrane inbetween parallel plate electrodes. A low dc voltage is applied to the electrodes for electrolyzing and the efficiency is remained in low. in this study, a novel electrolyzing cell with a pair of slit-type third electrodes installed inbetween parallel plate electrodes has been proposed and investigated experimentally. And pulse power wa supplied to between each electrodes. This slit type of third electrodes can concentrate the strong electric fields at the every its edges to accelerate the electrolyzing powers, and to generate oxygen bubble discharges for generating oxidants. And moreover the slits eliminate the space charge limiting action and the temperature of the water by leaking out through the slits from electrolyzing region to outside of the main electrode region. As a result, it was found that a strong electorzed water of pH 2.8 and pH 10.5 and oxidants dissolved water of 1 [ppm] in acidic water were obtained with a tap water fed at the electric current of 2 [A], which however were several times higher oxidant and ion concentration quantity compared with the conventional cell.

  • PDF

Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator (광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.