• Title/Summary/Keyword: High-voltage parts

Search Result 177, Processing Time 0.04 seconds

Analysis of Electric Field Distribution of High Voltage Polymeric Bushing with Structure (초고압 폴리머 부싱의 구조에 따른 전계분포 해석)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.489-490
    • /
    • 2008
  • This paper describes the analysis of electric field distribution of high voltage polymeric bushing with structure. The high voltage bushing consists of FRP tube and housing made of LSR. The field control can be achieved by means of the design of such internal field shaper and top corona ring as grading electrodes. In accordance, the optimized design uses both internal and external elements for electric stress grading at critical parts of the bushing. Maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the polymeric bushing.

  • PDF

Evaluation of Reliability on the 6.6kV Class Ceramic Coupler for On-line Partial Discharge Measurement in Winding Machines (권선형기기 On-line 부분방전 측정용 6-6kV급 Ceramic Coupler의 신뢰성 평가)

  • Kang Dong-Sik;Kim Yong-Joo;Yun Youn-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.

Technology Development Trend of Domestic and Foreign Electric Vehicle and Technology Development Strategy of Domestic Electric Vehicle Core Parts (국내외 전기자동차 기술 개발 동향 및 국내 전기자동차 핵심 부품 기술 개발 전략)

  • Son, Younh-Wook;Huh, Gun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.373-381
    • /
    • 2017
  • The electric vehicle market has increased rapidly in recent years. Established global automakers have announced that electric cars will be developed and distributed. Furthermore, current electric cars are not merely breezes, instead, they are the mainstream of automobiles. However, high prices, short mileage, and long charge times are the main obstacles to the spread of electric vehicles. To solve these problems, the competition for technology development for the expansion of electric vehicles worldwide intensifies because of the improvements in mileage, price reduction, and expansion of charging infrastructure. In this paper, the trends in the development of key technologies for electric vehicles in overseas markets and the present strategic goals for the development of key technologies for electric vehicles in Korea will be identified.

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash (수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰)

  • Lee, Kiyeon;Gil, Hyoungjun;Kim, Dongook;Kim, Dongwoo;Kang, Daechul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

Structure of Station Class Lightning Arresters and Electrical Characteristics of ZnO Varistor Blocks (발변전용 피뢰기의 구조 및 ZnO 바리스터 소자의 전기적 특성)

  • Cho, Han-Goo;Han, Se-Won;Lee, Un-Yong;Yoon, Han-Soo;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1158-1161
    • /
    • 2004
  • This paper presents structural characteristics of station class lightning arresters and electrical characteristics of manufactured ZnO varistor blocks which are usable in those arresters. Three types of station class lightning arresters were investigated and those are a ceramic arrester, a FRP tube type polymer arrester, and a FRP rod type polymer arrester. Each arrester has merits and demerits with structural characteristics. In general, polymer arresters were made of silicon rubber for housing materials, FRP tube or rod for mechanical strength, ZnO blocks for electrical characteristics, and metal parts for electrical contact and the silicon rubber, the housing materials, was directly injected to the arrester module which was assembly composed of electrodes, ZnO blocks and FRP tube or rod, and to prevent the nonlinear electric fields distribution on upper parts of arresters, the grade ring was adopted to the upper electrodes. The reference voltage, nonlinear coefficient, residual voltage, and voltage ratio of manufactured ZnO varistors are 4.90kV, 50, 9.54kV, 1.94, respectively. Compared to designed electrical characteristics, the reference voltage was low for 600v and the voltage ratio was slightly high. However, the characteristics of discharge withstand was so excellent that the mechanical destruction does not occur at the impulse current of $8/20{\mu}s$ 10kA for 100 times.

  • PDF

The Optimal Design of High Voltage Field Stop IGBT (고전압 Field Stop IGBT의 최적화 설계에 관한 연구)

  • Ahn, Byoung-Sup;Zhang, Lanxiang;Liu, Yong;Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.486-489
    • /
    • 2015
  • Power semiconductor device has a very long history among semiconductor, since the invention of low-pressure bipolar transistor 1947, and so far from small capacity to withstand voltage-current, high-speed and high-frequency characteristics have been developed with high function. In this study, the PWM IC Switch to the main parts used in IGBT (insulated gate bipolar transistor) for the low power loss and high drive capability of the simulator to Synopsys' T-CAD used by the 1,700 V NPT Planar IGBT, 1,700 V FS was a study of the Planar IGBT, the results confirmed that IGBT 1,700 V FS Planar is making about 11 percent less than the first designed NPT Planar IGBT.

Fabrication and characterization of fault current limiting devices made of stabilizer-free coated conductors (Stabilizer-free 초전도 선재를 이용한 한류 소자 제작 및 특성 시험)

  • Yim, Seong-Woo;Park, Chung-Ryul;Yu, Seong-Duck;Kim, Hye-Rim;Hyun, Ok-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.371-371
    • /
    • 2009
  • For the application of superconducting wires to fault current limiting devices, it is required that they have a high rated voltage when a fault occurs. Stabilizer-free coated conductors, particularly, shows a good performance for the high rated voltage, which is beyond 0.6 V/cm. In this study, using the stabilizer-free coated conductors, we made fault current limiting devices and examined their characteristics. Fault current limiting devices were fabricated with a shape of the cylinder of a mono-filar coil winding. Stabilizer-free coated conductors were wound along the mono-filar coil line and the terminal parts between the wire and metal were soldered using In solder. Two kinds of devices were fabricated by a different method in the terminal joint, one was made by a soldering and the other was made by a soldering-free joint. Critical currents and resistance at the joint parts were measured. In addition, long-time current flowing tests were also carried out for the characterization of the fault current limiting devices.

  • PDF

Inductor Characteristics of the Active Clamp Forward Converter for Adapter (어댑터용 능동클램프 포워드 컨버터 인덕터 특성)

  • Jang, Duk-Kyu;Woo, Seung-Hun;Kim, Chang-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1064-1069
    • /
    • 2010
  • Active clamp forward converter provides zero voltage switching, low voltage stress and wide input voltage range. The design technique leads to getting a higher efficiency under high switching frequency and optimal operating range. It is designed for notebook computer adapter with free input voltage and 19.5V/120W output ratings. The efficiency is measured to more than 90%. One of the most important circuit parts is the filter inductor besides the transformer in active clamp forward converter. In this paper, the process of inductor design is listed optimally.

Power Management of Open Winding PM Synchronous Generator for Unbalanced Voltage Conditions

  • EL-Bardawil, Ashraf;Moussa, Mona Fouad
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2192-2201
    • /
    • 2016
  • Wind energy is currently the fastest-growing electricity source worldwide. The cost efficiency of wind generators must be high because these generators have to compete with other energy sources. In this paper, a system that utilizes an open-winding permanent-magnet synchronous generator is studied for wind-energy generation. The proposed system controls generated power through an auxiliary voltage source inverter. The VA rating of the auxiliary inverter is only a fraction of the system-rated power. An adjusted control system, which consists of two main parts, is implemented to control the generator power and the grid-side converter. This paper introduces a study on the effect of unbalanced voltages for the wind-generation system. The proposed system is designed and simulated using MATLAB/Simulink software. Theoretical and experimental results verify the validity of the proposed system to achieve the power management requirements for balanced and unbalanced voltage conditions of the grid.

Voltage Application Indicator Using Liquid Crystal Device (LCD를 이용한 통전상태 표시기 개발)

  • Koo, K.W.;Lyu, S.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1757-1759
    • /
    • 2000
  • To make a inspection and maintenance of the high voltage equipment, electric machinery to transmit and distribute the electric power, the appearance of a simple and inexpensive indicator with which the charge condition of bare conductor parts could be read at a Stance has been needed. Liquid crystal has recently been expanding its application rapidly in appliances for everyday use. Since its display energy is extremely small, it is possible to obtain the working current with simple condenser voltage divider that makes use of stray capacity when it is applied to electric power equipment. Thus, an apparatus has finally appeared which is close to the one they have sought and indicates the existence of voltage impressions.

  • PDF