• 제목/요약/키워드: High-strength wire

검색결과 179건 처리시간 0.036초

하이브리드 절연필름의 전동기권선 적용 특성 연구 (Technology and Application of Hybrid Insulation Film for Electric Magnet Wire)

  • 한세원;한동희;강동필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.210-211
    • /
    • 2006
  • This study presents the technology and application of hybrid insulation film for electric magnet wire. In order to make the high efficient motor with high space factor, it is necessary to develop a self-lubrication heat-resistant insulation film that can be used when the space factor 70% or more. A key to achieving high windability is to increase the lubricity and bonding strength of vanish, which for a magnet wire generally determines the mechanical scratches characteristics. Effective ways to reduce scratches include improving insulation film prepared by organic and inorganic hybrid synthesis methods.

  • PDF

TiO2 성분 플럭스충진와이어에 따른 S500강의 GMA 용접부 특성 (Characteristics of GMA Weld Zone on TiO2 Different Component Flux Cored Wire for S500 Grade Steel)

  • 유철;고영봉;박경채
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.335-342
    • /
    • 2015
  • Recently, the production of oil and gas at the arctic ocean and offshore has been growing. Accordingly, S500 steel with the high tensile strength and excellent toughness has been used and flux cored wire that can be welded to the S500 has been required. In this study, we carried out observation of microstructures, mechanical properties and CTOD (crack tip openning displacement) in the weld zone that GMA (gas metal arc) welded with different component of $TiO_2$ flux core wire (the main components, rutile or Ti-slag) for S500 steel. Weld zone produced with Ti-slag flux cored wire has formed a enough acicular ferrite and shown excellent impact toughness at $-40^{\circ}C$, tensile strength at room temperature and CTOD at $-20^{\circ}C$. As a result, the developed flux cored wire was suitable for S500 steel.

Slope stabilization with high-performance steel wire meshes in combination with nails and anchors

  • Rudolf Ruegger;Daniel Flum
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 사면안정 학술발표회
    • /
    • pp.3-38
    • /
    • 2000
  • Slope draperies in soil and rock are a well known method to avoid rockfalls into the roads or onto housings. Common wire mesh or a combination of wire mesh and wire rope nets are pinned to the slope by the means of fully grouted nails or anchors. Most of these installations have not been designed to stabilize the slope, but simply avoid the rocks from bouncing. The combination of soil- or rocknailing with a designable flexible facing system offers the advantage of a longterm stabilization of slopes and can replace other standard methods for slope stabilization. The capability to transfer axial and shear loads from the flexible facing system to the anchor points is most decisive for the design of the stabilization system. But the transfer of forces by mesh as pure surface protection devices is limited on account of their tensile strength and above all also by the possible force transmission to the anchoring points. Strong wire rope nets increase the performance for slope stabilizations with greater distances between nails and anchors and are widely used in Europe. However, they are comparatively expensive in relation to the protected surface. Today, special processes enable the production of diagonally structured mesh from high-tensile steel wire. These mesh provide tensile strengths comparable to wire rope nets. The interaction of mesh and fastening to nail / anchor has been investigated in comprehensive laboratory tests. This also in an effort to find a suitable fastening plates which allows an optimal utilization of the strength of the mesh in tangential (slope-parallel) as well as in vertical direction (perpendicular to the slope). The trials also confirmed that these new mesh, in combination with suitable plates, enable substantial pretensioning of the system. Such pretensioning increases the efficiency of the protection system. This restricts deformations in the surface section of critical slopes which might otherwise cause slides and movements as a result of dilatation. Suitable dimensioning models permit to correctly dimension such systems. The new mesh with the adapted fastening elements have already been installed in first pilot projects in Switzerland and Germany and provide useful information on handling and effects.

  • PDF

트위스트 다이아몬드 와이어의 성능향상을 위한 특성평가에 관한 연구 (A Study on New Twist-Diamond Wire Characteristics for Improving Processing Performance)

  • 박창용;권현규;팽발;정봉교
    • 한국기계가공학회지
    • /
    • 제15권1호
    • /
    • pp.26-33
    • /
    • 2016
  • In this study, a new method to develop a fixed diamond wire for silicon wafer machining by the multi-wire cutting method was developed. The new twist diamond wire has improved performance with high breaking strength and chip flutes structure. According to these characteristics, the new twist diamond wire can be used in the higher speed multi-wire cutting process with a long lifetime. Except the design of the new structure, the twist diamond wire is coating by electroless-electroplating process. It is good for reducing breakage and the falling-off of diamond grains. Based on the silicon material removal mechanism and performance of the wire-cutting machine, the optimal processing condition of the new twist diamond wire has been derived via mathematical analysis. At last, through the tensile testing and the machining experiments, the performance of the twist diamond wire has been obtained to achieve the development goals and exceed the single diamond wire.

350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구 (A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line)

  • 이학표;서기범;박재영
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

형상기억합금 선재가 삽입된 폴리머기지 능동복합재료의 회복력에 미치는 계면 접합강도의 영향 (Effect of interface bonding strength on the recovery force of SMA reinforced polymer matrix smart composites)

  • 김희연;김경섭;홍순형
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.18-21
    • /
    • 2003
  • The effect of interface bonding strength on the recovery force of SMA wire reinforced polymer matrix composites was investigated by pullout test. Firstly, the recovery forces and transformation temperatures of various prestrained SMA wires were measured and 5% prestrained SMA wires were prepared for the reinforcements of composites. EPDM incorporated with 20vol% silicon carbide particles(SiCp) of 6, 12, $60{mutextrm{m}}$ size were used as matrix. Pullout test results showed that the interface bonding strength increased when the SiCp size decreased due to the increase of elastic modulus of matrix. Cyclic test of composites was performed through control of DC current at the constant displacement mode. The abrupt decrease of recovery force during cycle test at high current was occurred by thermal degradation of matrix. This was in good agreement with temperature related in the thermal degradation of matrix. The hysteresis of recovery force with respect to the temperature was compared between wire and composite and the hysterisis of composites was smaller than the wire due to less thermal conduction.

  • PDF

최고운행속도 350km/h급 전차선로 최대경간길이 계산 기법 (Technique of Maximum Span Length Calculation for 350km/h High Speed Catenary System)

  • 창상훈;이기원;유향복
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.924-931
    • /
    • 2011
  • This paper deal with maximum span calculation technique for 350km/h high speed catenary system. Considers a geometric interaction, possible maximum span length is between two pole. Wind condition and the train current collector is moving even to being pantograph does not escape while operating. Uses like this justice and possible maximum span length is follow next condition. (i) Operating range of pantograph fan head, (ii) The wind velocity which assumes from system, (iii) Width in pantograph from operation height moving, (iv) Type of processing Catenary system, specially tensile strength of overhead contact wire and messenger wire etc. When accurately calculates the maximum permission span, the dropper between of overhead contact wire and messenger wire and must consider the correlation.

  • PDF

금속/폴리머 접합강의 충격 특성에 대한 실험적 연구 (Impact Energy Absorbing Capability of Metal/Polymer Hybrid Sheets)

  • 공경일;권오범;박형욱
    • 대한기계학회논문집A
    • /
    • 제41권2호
    • /
    • pp.137-142
    • /
    • 2017
  • 최근 자동차 산업에서 경량화이면서 외부 충격에 민감한 시트 프레임은 안전성을 고려하여 꾸준히 연구개발되고 있다. 특히 본 연구에서는 고장력 강판과 폴리머의 이종 소재를 이용한 시트 프레임의 충격 특성에 대해 살펴보았다. 또한, 충격시 변위는 소재에 대해 굽힘 현상을 고려한 등가 굽힘강성식을 도입하여 살펴보았다. 층간 wire-web 구조물의 다양한 형상의 공학 디자인을 통해 충격시 변화가 적은 디자인을 설계하였으며, 육각형의 층간 wire-web 구조물이 외부 충격대비 안전계수가 높음으로 인해 흡수능력이 향상될 것으로 기대하고 있다. 이러한 연구 결과를 토대로 층간 wire-web 구조물의 설계를 통해 레진과의 함침을 높이고 이종 소재로써의 충격민감도에 유리한 제품을 개발할 수 있을 것으로 사료된다.

Half-cell 기반 multi-wires 접합 공정에서 접합 특성에 영향을 주는 요인과 효율의 상관관계 연구 (A Study on the Relationship between Factors Affecting Soldering Characteristics and Efficiency of Half-cell Soldering Process with Multi-wires)

  • 김재훈;손형진;김성현
    • Current Photovoltaic Research
    • /
    • 제7권3호
    • /
    • pp.65-70
    • /
    • 2019
  • As a demand of higher power photovoltaic modules, shingled, multi-busbar, half-cell, and bifacial techniques are developed. Multi-busbar module has advantage for large amount of light havesting. And, half-cell is high power module for reducing resistive losses and higher shade tolerance. Recently, researches on multi-busbar is focused on reliability according to adhesion and intermetallic compound between Sn-Pb solder and Ag electrode. And half-cell module is researched to comparing with full-sized cell module for structure difference. In this study, we investigated the factors affecting to efficiency and adhesion of multi-wires half-cell module according to wire thickness, solder thickness, and flux. The results of solar simulator and peel test was that peel strength and efficiency of soldered cell is not related. But samples with flux including high solid material showed high efficiency. The results of FE-SEM and EDX line scan on cross-section between wire and Ag electrode for different flux showed thickness of solder joint between wire and Ag electrode is increasing through solid material increasing. Flux including high solid material would affect to solder behavior on Ag electrode. Higher solid material occurred lower growth of IMC layer because solder permeate to sider of wire ribbon than Ag electrode. And it increased fill factor for high efficiency. In soldering process, amount of solid material in flux and solder thickness are the factor related with characteristic of soldered photovoltaic cell.

고강도 인바합금의 석출거동 및 기계적 특성 (Precipitation Behavior and Mechanical Properties of High Strength Invar Alloy)

  • 정재용;이규동;하태권;정효태
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.547-550
    • /
    • 2008
  • Precipitation characteristics of the Fe-36Ni based high strength Invar alloy for power transmission wire was investigated in this study. High strength can be obtained in this alloy through precipitation hardening and strain hardening by cold working. $FactSage{(R)}$ in this study, revealing that equilibrium phases which can be formed are two kind of MC-type precipitates and MoC carbide. The latter stoichiometric carbide was expected to be formed at relatively lower temperature $770^{\circ}C$. High strength above 1000MPa and 40% of elongation were obtained at room temperature in both cases.

  • PDF