• 제목/요약/키워드: High-speed measuring device

검색결과 57건 처리시간 0.026초

로봇용 6축 힘/모멘트 센서를 위한 고성능측정기 개발 (Development of High-Precision Measuring Device for Six-axis Force/Moment Sensor)

  • 신희준;김갑순
    • 한국정밀공학회지
    • /
    • 제24권10호
    • /
    • pp.46-53
    • /
    • 2007
  • This paper describes the development of a high-precision measuring device with DSP (digital signal processor) for the accurate measurement of the 6-axis force/moment sensor mounted to a humanoid robot's ankle. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, and Fz and moments Mx, My, and Mz to itself, and control the foot using the measured them. The applied forces and moments should be measured from two 6-axis force/moment sensors mounted to the feet, and the sensor is composed of Fx sensor, Fy sensor, Fz sensor, Mx sensor, My sensor and Mz sensor in a body (single block). In order to acquire output values from twelve sensors (two 6-axis force/moment sensor) accurately, the measuring device should get the function of high speed, and should be small in size. The commercialized measuring devices have the function of high speed, unfortunately, they are large in size and heavy in weight. In this paper, the high-precision measuring device for acquiring the output values from two 6-axis force/moment sensors was developed. It is composed of a DSP (150 MHz), a RAM (random access memory), amplifiers, capacities, resisters and so on. And the characteristic test was carried out.

건전지의 성능평가 장치 (A Performance Testing Device of Drycell)

  • 정헌
    • 제어로봇시스템학회논문지
    • /
    • 제17권2호
    • /
    • pp.171-175
    • /
    • 2011
  • In this paper, I have developed a high-speed and high-resolution measuring device in order to check the performance of drycell. The system is developed for the drycell manufacturing plant. Measuring time is one of key factors to inference on the production speed. So the developed system is designed to generate the classified result up to 1200ea/min. In the other words, each product can be classified within 25ms. There have been many studies to estimate both state of charge as well as state of health, such as OCV (Open Circuit Voltage), SC (Short Circuit) and measuring impedance with frequency pulse. But those methods take a few second due to surface discharge. To overcome the phenomenon, I developed the method to engage the reverse current to two electrodes of battery. As a result, I could achieve to measure the indigenous capacity without the problem of surface discharge.

2축 힘/모멘트센서를 이용한 원통형 손가락 힘측정장치 개발 및 특성평가 (Development of Cylindrical-type Finger Force Measuring System Using Two-axis Force/Moment Sensor and its Characteristic Evaluation)

  • 김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제17권5호
    • /
    • pp.484-489
    • /
    • 2011
  • Some patients can't use their hands because of inherent and acquired paralysis of their fingers. Their fingers can recover with rehabilitative training, and the extent of rehabilitation can be judged by grasping a cylindrical-object with their fingers. At present, the cylindrical-object used in hospitals is only a cylinder which cannot measure grasping force of the fingers. Therefore, doctors must judge the extent of rehabilitation by watching patients' fingers as they grasp the cylinder. A cylindrical-type finger force measuring system which can measure the grasping force of patients' fingers should be developed. This paper looks at the development of a cylindrical-type finger force measuring system with two-axis force/moment sensor which can measure grasping force. The two-axis force/moment sensor was designed and fabricated, and the high-speed force measuring device was designed and manufactured by using DSP (digital signal processing). Also, cylindrical-type finger force measuring system was developed using the developed two-axis force/moment sensor and the high-speed force measuring device, and the grasping force tests of men were performed using the developed system. The tests confirm that the average finger forces of right and left hands for men were about 186N and 172N respectively.

방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구 (A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose)

  • 이주현;이승호
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.544-551
    • /
    • 2014
  • 본 논문에서는 방사선 측정장치의 저준위 방사선 측정 알고리즘과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선을 위한 알고리즘 및 장치의 구성을 제안한다. 저준위 방사선 측정의 측정 정밀도를 개선하기 위한 알고리즘은 방사선 측정센서로부터 수집된 펄스의 누적평균을 기준으로 하는 듀얼 윈도우 방사선 수치 측정법을 사용한다. 방사선량의 급격한 변화에 따른 장치의 반응 속도개선을 위한 알고리즘은 신규로 입력된 6초 동안의 데이터 패턴분석을 통한 듀얼 윈도우 방사선 수치 측정법을 사용한다. 제안된 알고리즘의 검증을 위한 하드웨어 장치로는 센서 및 고전압 발생부, 제어부, 충전 및 전원회로부, 무선통신부, 디스플레이부 등으로 구성되어 있다. 제안된 알고리즘에서 사용한 듀얼 윈도우 방사선 수치 측정법을 실험한 결과, 기존 5uSv/h 수준의 저선량 한계에서 대체로 불확도가 낮아지고 선형성이 개선됨을 확인할 수 있었다. 또한 급격한 방사선량의 변화에 대한 장비의 반응속도 개선에 대해 실측실험을 통해 6초 이후에 변화된 수치가 반응함을 확인하였다. 따라서 제안된 알고리즘이 급격한 변화에 따른 장치의 반응속도가 개선됨을 확인할 수 있었다.

고속충돌 시험용 지능형 다중 카메라 시스템 개발 (Development of Intelligent Multiple Camera System for High-Speed Impact Experiment)

  • 정동택;박치영;진두한;김태연;이주연;이인석
    • 대한기계학회논문집A
    • /
    • 제37권9호
    • /
    • pp.1093-1098
    • /
    • 2013
  • 방탄소재로서 사파이어 재료가 대두되고 있지만 고속 충돌관련 동적거동 및 파괴특성에 관한 연구는 부족한 실정이다. 탄자와 취성세라믹재료간의 상호작용을 연구하기 위해서는 고화질의 초고속 연속영상이 필수적이다. 본 연구에서는 고속충돌 및 관통 현상을 순차적으로 촬영할 수 있는 장치를 개발하였다. 이 장치는 속도측정장치, 마이크로프로세서를 사용한 카메라 구동장치 그리고 다수의 CCD카메라로 이루어져있다. 선형배열센서를 사용한 속도측정장치는 직경 1-2 mm 탄자의 마하 3 속도를 측정할 수 있다. 발사된 탄자가 속도측정장치를 통과하면 속도와 시간이 측정되고 탄자가 비행하는 동안 카메라 구동장치가 정확한 충돌시간을 계산하여 다수의 카메라에 순차적으로 트리거 신호를 보내서 충돌 전후의 형상을 순차적으로 촬영한다. 정확한 충돌시간 예측을 못하면 고해상도의 사진촬영이 거의 불가능하다. 본 연구에서 개발된 정밀 촬영장치를 사용하여 고해상도의 영상을 확보할 수 있었다.

High Lead Ball Screw를 사용한 고속이송계의 특성 (The Characteristics of High Speed Feed Drive System using High Lean Screw)

  • 고해주;박성호;정윤교
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.97-103
    • /
    • 2001
  • The study on the high-speed machine tool is very important for the improvement of productivity since it can shortens cutting and non-cutting time. Especially, high speed of feed drive system is the major research field. In the industries of the advanced countries, the feed drive systems at the speed of 60 m/min have been already developed based on the high lead ball screws. In this study, a high speed feed drive system at the speed of 60 m/ min has been developed, and its movements characteris-tics are investigated. As the movement characteristics, positioning accuracy, angular accuracy, straightness and micro step-response are measured. Thermal characteristics of the system is also discussed. For measuring the movement characteris-tics, a laser interferometer, a memory-based Hi-coder and a cooling device are used. The experimental results confirm that the movement characteristics and the thermal behavior of the system are satisfactory in the aspect of accuracy and stability.

  • PDF

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo Sung-Il;Cho Yong-Hyun;Mok Jin-Yong;Park Choon-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1548-1556
    • /
    • 2006
  • Appropriate contact force is required for the pantograph on the high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the body of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measuring system was developed. The forces acting on the pantograph were clarified and a practical procedure to estimate the forces was proposed. A special device was invented and applied to measure the aerodynamic lifting force. Measured contact forces were displayed by the developed system and evaluated based on the criteria.

고속가공기를 이용한 CAD/CAM 포켓가공에 관한 연구 (A Study on CAD/CAM Pocket Processing using the High Speed Machine)

  • 류춘회;이육형;송준호
    • 한국기계가공학회지
    • /
    • 제3권3호
    • /
    • pp.32-38
    • /
    • 2004
  • Recently, the system of high speed milling(HSM) is widely used for reducing the operation time and maximizing efficiency of work. The most research of high speed milling system is still leaves much to be desired. Specially the research of mass pocket high speed processing with high precision is the first and probably the last. So this paper showed mass pocket processing of high precision with a duralumin and then confirmed a cause of inferior goods through the CAD/CAM pattern simulation and experimentation. And this paper showed high speed processing system reduce the rate of inferior from this optimal pattern.

  • PDF

사람의 평형감각 측정시스템 개발 (Development of an Equilibrium Sensation Measuring System for Human Being)

  • 김갑순
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.62-69
    • /
    • 2009
  • This paper describes the development of the new type equilibrium sensation measuring system for human with handicap in the equilibrium sensation. The medium and small hospital could not use the developed equilibrium sensation measuring system, because it is very high prices. Therefore, the new type system should be developed to measure the numerical value of the equilibrium sensation in human with handicap. In this paper, First, two 3-axis force/moment sensors which can measure force Fz, moments Mx and My simultaneous were designed and manufactured, second, the high speed measuring device which can acquire the output from two 3-axis force/moment sensors, third, the new type equilibrium sensation measuring system was developed, then the characteristic test of the developed equilibrium sensation measuring system carried out, it is confirmed that the system could measure the swing body of human with handicap.

소형-고속 스핀들의 반경방향 오차분석 방법 (Analysis of radial error motion in a small-sized and high-speed spindle)

  • 이응삼;이재하;양승한
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.604-608
    • /
    • 2004
  • In this paper, an efficient method is proposed to analyze the radial error of a miniaturized-high speed spindle system. Initially, a device is constructed for measuring the radial error motion using capacitance sensors. The capacitance sensors are placed perpendicular to the axis of the shaft and at 90o to each other. The spindle is rotated at high speed and the profile of the spindle is recorded. An algorithm is developed for analyzing the spindle data and determining the radial error of spindle. The present algorithm uses homogeneous transform matrix (HTM) method and iterative process for determining the radial error. The analysis procedure is performed for different speeds of the spindle. The data obtained from the present system and the results of evaluation are also presented in this paper. It is observed that this method is effective in determining and analyzing the spindle errors for high speed miniaturized spindle.

  • PDF