• Title/Summary/Keyword: High-rise Apartments

Search Result 138, Processing Time 0.032 seconds

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

A Study on the Evaluation of Dwelling Environment around High - Rise Apartments (고층아파트의 거주환경평가에 관한 연구 - 구미시 생활권별 아파트 입지를 중심으로 -)

  • 정덕규;전병두;김익환
    • Journal of the Korean housing association
    • /
    • v.8 no.3
    • /
    • pp.141-151
    • /
    • 1997
  • This study was conducted to examine the environmental factors of apartments and therefore to suggest elements necessary to plan environments by evaluating and analysing both reside environments and conditions with residents at high-rise apartments in Kumi city. Kyongbuk. Korea. The result of this study is summarized as follows: 1) The motive of residence at apartment showed mainly the better environment of nature. and that the locational condition of those apartments was considered as a good standard for evaluating the apartment. 2) The evaluation of satisfaction showed that residents residing at apartment A tended to be satisfaied with all factors other than ‘complex’ although there was wholly dissatisfaction. In addition. it was shown that apartment B was satisfaied with housing and complex. apartment C with comfort. respectively. and apartment D with housing. 3) The evaluation of image showed that apartment C indicated the lowest variety of its complex while other factors were highly considered. Their image concerning residence was highest in apartment A. most lowest in apartment C. Then. apartment B showed the highest familiarity with and recognition of apartment complex.

  • PDF

Distribution of Heat and Smoke Related to Openings in Hise-Rise Apartment Building Fires (고층 공동주택의 개구특성에 따른 화재시 열.연기유동에 관한 연구)

  • 이지희
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.59-79
    • /
    • 2001
  • The paper proposes alternatives for fire safety in architectural planning through heat-smoke distribution related to openings so that we decrease casualty and property loss by fire and lay a great emphasis on building high-rise apartments with consideration of fire safety in Korea. An analysis program(HFA-Heat Fluid Analysis) is built to perform simultaneously numerical analysis and experimental analysis on rooms, units and buildings. In consequence, on the first, fire prevention methods are required to be set up related to openings for design rooms since the flow of heat and smoke is influenced by the type of openings in high-rise apartments. Second, the numerical analysis showed that different planning types cause to show differences in the spreading time of heat and smoke to design the units of high-rise apartments. On the third, each unit building showed different fire behavior depending on openings by numerical analysis and small scaled experiment on heat and smoke flow.

  • PDF

Contents Analysis on the Dwellers' Medical Reports in High-Rise Mixed-Use Apartment (주상복합아파트 거주자의 질병자료에 관한 내용 분석)

  • Choi, Byung-Sook;Kang, In-Ho
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.187-192
    • /
    • 2008
  • This purpose of this study is to figure out the inter-relationship between the residence stories in high-rise mixed-use apartments and their residents' disease patterns throughout the dweller's medical reports in high-rise mixed-use apartments. Research basic data are obtained from medical fee request of National Health Insurance Corportion. Data are limited a housing complex to 'A' high-rise mixed-use apartment and a medical treatment time to 3 years(2004-2006). Analysis data of total 346,286 medical records, 43,159 disease records, and 8,999 persons are collected. By analyzing those data, findings are as follows: 1) Women is more medical treatments than men, 40-50 age group is more treated, and the residents of 6-25 stories are more received medical treatments. Diseases of the respiratory system and diseases of the eye and adnexa are relatively treated higher than other diseases. 2) The diseases of the respiratory system, the eye and adnexa, the skin and subcutaneous tissue, the ear and mastoid process), and the asthma have not relation to the high-storied residence through the data of disease records and personal records. But the analysis on the data of children, 7 ages and less, is showed a significant relation. And to conclude, there is no relationship between the residence of high-stories in that apartment and dwellers' disease patterns, but there is a little probable to the relationship in the pre-school child.

  • PDF

An Experimental Study of Fire Risk Characteristic by Extended Balcony of High-Rise Apartments in Fire (고층아파트 화재시 발코니 확장에 따른 화재 위험성에 관한 실험 연구)

  • Kim, Woo-Suk;Kim, Wha-Jung;Lee, Gwang-Won;Lee, Ji-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.65-71
    • /
    • 2012
  • Changes in the styles of communities are leading of increases in the number of high-rise apartments and commercial-apartment structures. Tall high-rise structures, while presenting unique economies of scale and cost effectiveness, tend to be highly engineered and complex structures. In the event of a fire, this complexity in design also results in a complexity in the behavior of fire propagation and control. High-rise structures are among the most potentially dangerous due to the high population density in the building, and the inherent limitations on evacuation and on fire control services. One of the most critical points of fire propagation is the movement of fire through the outer wall structures. Controlling such propagation is essential in controlling the spread of the fire throughout the building itself, as well as controlling the potential for its spread to adjacent buildings. In this study, we will be examining the potential for fire control design and effects mitigation using a 1/4.5 scale model. The primary focus of the study will be the effects of extended balconies into the structure of high-rise apartments. The authors will also consider the effectiveness of reduced-scale model tests.

Indoor Airflow of High-Rise Apartment with Different Types of Box-Windows (초고층 공동주택의 이중외피 창호 유형별 실내기류 특성 비교)

  • Choi, Tae-Hwoan;Jeon, Mi-Sook;Lee, Jung-Hyun;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.993-998
    • /
    • 2006
  • High-rise apartments have a problem using natural ventilation because of the strong outdoor wind velocity. Conventional high-rise apartments have adopted mechanical ventilation systems to maintain the indoor air quality. However, it leads to the overuse of electricity and the sick house syndrome. Double-skin facade is the alternative for the high-rise building to use natural ventilation and this study is focused on the performance of the box-window, which is a kind of double-skin facades. Indoor wind velocity and HCHO concentrations are analyzed with three types of box-windows: the diagonal type, parallel type and perpendicular type. The airflow is simulated by computational fluid dynamics program. Box-windows reduce the maximum value of indoor wind velocity about 50% compared with the single window and the HCHO concentrations do not have the big difference. Box-windows could be the alternative to enhance the use of the natural ventilation and indoor air quality of the high-rise apartment.

  • PDF

A Study on the Improvement and Environment-friendly Interior Space Planning of High-rise Residences in Korea - focuesd on the case analysis by environment-friendly architectural certification - (국내 초고층 주거의 친환경적 실내 공간 계획 및 개선방안 연구 - 친환경 건축 인증 제도에 의한 사례 분석을 중심으로 -)

  • Kim, Ja-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.3
    • /
    • pp.23-33
    • /
    • 2008
  • After the concept of apartments was introduced in 1960s in Korea, on account of the development of architectural technology and science, high-rise residences in Korea are getting higher, and these residences have been becoming high-rise commercial/residential buildings since 1990. Nowadays, as the construction of high-rise commercial residential building complex is booming, the difference between these complex and high-rise apartments is getting smaller, and these two kind of high-rise residences are becoming new residential style in Korea. And these high-rise residences are considered the symbol of wealth owing to the marketing strategy emphasizing high quality, refined interior, a fair view, and the protection of privacy. However, high-rise residences bring about many problems related to health and psychology caused by the consumption of a large amount of energy, pollutant emission, the deterioration of the quality of indoor air, and vibration. For this reason, in this study, we tried to emphasize the necessity of environment-friendly access to provide healthy living environment and to reduce the negative effect of housing life in high-rise residences, and find the method to improve environment-friendly quality and health of residents in interior space. Therefore, this study aims to detect the problems and the items to be improved of interior spaces of high-rise residences by quantitative, qualitative analysis of the evaluation elements and the floor planning elements deduced from environment-friendly architectural certification in Korea and the other countries, and suggest the guideline to improve the environment-friendly quality of these interior spaces.

Estimating Door Open Time Distributions for Occupants Escaping from Apartments

  • Hopkin, Charlie;Spearpoint, Michael;Hopkin, Danny;Wang, Yong
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 2021
  • The door open time, resulting from occupants evacuating from apartments, is an important parameter when assessing the performance of smoke ventilation systems in high-rise apartment buildings. However, the values recommended in UK design guidance appear to have limited substantiation. Monte Carlo simulations have been carried out considering variabilities in door swing time, flow rate and number of occupants. It has been found that the door open time can be represented by a lognormal distribution with a mean of 6.6, 8.7 and 11.1 s and a standard deviation of 1.7, 3.2 and 4.7 s for one, two and three-bedroom apartments, respectively. For deterministic analyses, it is proposed that the 95th percentile values may be adopted in line with recommended practice for other fire safety design parameters such as fuel load density and soot yield, giving door open times of 10 s to 19 s, depending on the number of bedrooms.

Sustainable Regeneration Strategies of High-Rise Apartment Estates of the Early 1990s' New Towns in the Capital Area (수도권 1기 신도시 고층고밀아파트 단지의 지속가능한 주거지 재생을 위한 과제)

  • Kwon, Seong Sil;Oh, Deog Seong
    • KIEAE Journal
    • /
    • v.9 no.3
    • /
    • pp.47-59
    • /
    • 2009
  • In Korea has been supplied a large quantities of apartments since 1970s. The deteriorated middle-rise apartments of 1970s' have been rebuilt. It isn't lucrative to reconstruct the high-rise Apartment estates of the early 1990s' new towns in the capital area. Therefore the sustainable regeneration strategies of them have to be found. This research have been focused on the social and economical changes based on demography and the turning of technology and paradigm, the cities competitiveness compared with 2nd era new towns, physical deterioration of themselves. In these aspects, high-rise apartment estates in the 1st new towns face to 10 challenges such as an aging society, a multicultural society, U-city, an environmentally-friendly situation, the cities competitiveness of social, conomical and physical environment, the declining of estates, buildings and units. This study analyzed problems of 1st new town apartment estates and suggested regeneration tasks in accordence with those problems. The tasks are as follows. To accommodate the 1st new town apartment estates to social changes, they need to have a variety of community facilities and units, an opportunity of esidents participation. to establish a self-sufficient economy, a community usiness has to be vitalized and an ecological environment, an infrastructure of u-city and an improvement of physical environment obtained.

Does the placement of automated external defibrillators affect first responders' willingness to perform cardiopulmonary resuscitation in high-rise residential buildings?

  • Lee, Dong Eun;Ryoo, Hyun Wook;Ahn, Jae Yun;Moon, Sungbae;Kim, Jong Kun;Kim, Yun Jeong;Park, Jung Bae;Kim, Jung Ho;Lee, Kyung Woo;Jin, Sang Chan
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.557-567
    • /
    • 2018
  • Objective: The increasing number of people living in high-rise apartments may result in a delayed response from emergency medical technicians called out for an out-of-hospital cardiac arrest, making the role of apartment managers as the first responders extremely important. This study investigated whether automated external defibrillator (AED) placement influences the willingness of apartment managers to perform cardiopulmonary resuscitation (CPR) and use an AED. Methods: A cross-sectional target population-based survey was conducted in Daegu, July 2016. Questionnaires were sent to apartment managers working in apartments with more than 500 households. The general characteristics of the respondents, status of CPR education, and knowledge about and willingness to perform CPR and use an AED were investigated. Results: Of the 1,445 respondents, 758 (52.5%) worked in apartments with AEDs, of which 77.8% and 70.8% were willing to perform CPR and use an AED, respectively, compared with 68.1% and 60.0% of respondents who worked in apartments without AEDs. After adjusting for potential confounders, AED placement was associated with the willingness to perform CPR (odds ratio [OR], 1.33; 95% confidence interval [CI], 1.04-1.71) and use an AED (OR, 1.39; 95% CI, 1.10-1.75). Prior CPR training and accurate knowledge of CPR skills were also associated with the willingness to perform CPR and use an AED. Conclusion: Placing AEDs in high-rise apartment buildings and providing refresher CPR education for maintaining CPR skills will be necessary to support apartment managers in their role as first responders.