• Title/Summary/Keyword: High-resolution computed tomography

Search Result 163, Processing Time 0.034 seconds

Image Quality Improvement in Computed Tomography by Using Anisotropic 2-Dimensional Diffusion Based Filter (비등방성 2차원 확산 기반 필터를 이용한 전산화단층영상 품질 개선)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • The purpose of this study was tried to remove the noise and improve the spatial resolution in the computed tomography (CT) by using anisotropic 2-dimensional (2D) diffusion based filter. We used 4-channel multi-detector CT and american association of physicists in medicine (AAPM) phantom was used for CT performance evaluation to evaluate the image quality. X-ray irradiation conditions for image acquisition was fixed at 120 kVp, 100 mAs and scanned 10 mm axis with ultra-high resolution. The improvement of anisotropic 2D diffusion filtering that we suggested firstly, increase the contrast of the image by using histogram stretching to the original image for 0.4%, and multiplying the individual pixels by 1.2 weight value, and applying the anisotropic diffusion filtering. As a result, we could distinguished five holes until 0.75 mm in the original image but, five holes until 0.40 mm in the image with improved anisotropic diffusion filter. The noise of the original image was 46.0, the noise of the image with improved anisotropic 2D diffusion filter was decreased to 33.5(27.2%). In conclusion improved anisotropic 2D diffusion filter that we proposed could remove the noise of the CT image and improve the spatial resolution.

Korean Guidelines for Diagnosis and Management of Interstitial Lung Diseases: Part 4. Cryptogenic Organizing Pneumonia

  • Choi, Sue In;Jung, Won Jai;Lee, Eun Joo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.3
    • /
    • pp.171-175
    • /
    • 2021
  • Cryptogenic organizing pneumonia (COP) is a type of idiopathic interstitial pneumonia with an acute or subacute clinical course. Bilateral lung consolidations located in the subpleural area and bronchovascular bundle are the most common findings on chest high-resolution computed tomography. The pathologic manifestations include granulation tissue in the alveoli, alveolar ducts, and bronchioles. COP responds fairly well to glucocorticoid monotherapy with rapid clinical improvement, but recurrence is common. However, treatment with combined immunosuppressant agents is not recommended, even if the COP patient does not respond to glucocorticoid monotherapy with expert opinion.

Image Evaluation of Resolution Parameter and Reconstitution Filter in 256 Multi Detector Computed Tomography by Using Head Phantom (256 다중 검출기 전산화단층촬영에서 두개부 전용 팬톰을 이용한 분해능 파라메터와 재구성 필터의 영상 평가)

  • Gu, Bon-Seung;Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.814-821
    • /
    • 2011
  • The purpose of this study was to evaluate of resolution parameter and reconstitution filter in the 256 multi detector computed tomography(MDCT) by using the head phantom. We used 256 MDCT, and head phantom of philips system. We evaluated to image quality by using Extended Brilliance Workspace. The protocol were axial scan method with 120 kVp, 0.5 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of field of view(FOV), $512{\times}512$ of matrix size, 1.0 of pitch, $128{\times}0.625$ mm of collimations. The resolution parameter was applied for 'Standard', 'High' and 'Ultrahigh'. The reconstitution filters were changed to seven type of 'A', 'B', 'C', 'D', 'UA', 'UB', 'UC'. The assesment factors of image quality were the uniformity, the noise, the linearity and 50% and 10% of the modulation transfer function(MTF). Finally The good image quality in 'High' resolution parameter showed at the uniformity, the linearity and 50% and 10% of MTF. The 'UA', 'UB' reconstitution filter showed at the good image quality of the uniformity and the noise and 'C' reconstitution filter showed at the same result of the linearity and 50% and 10% of MTF.

Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations

  • Shokri, Abbas;Eskandarloo, Amir;Norouzi, Marouf;Poorolajal, Jalal;Majidi, Gelareh;Aliyaly, Alireza
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.11-19
    • /
    • 2018
  • Purpose: This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. Materials and Methods: The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact(control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. Results: In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. Conclusion: The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

Analysis of Particle Rearrangement during Sintering by Micro Focus Computed Tomography $({\mu}CT)$

  • Nothe, M.;Schulze, M.;Grupp, R.;Kieback, B.;Haibel, A.;Banhart, J.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.808-809
    • /
    • 2006
  • The decrease of the distance between particle centers due to the growth of the sinter necks can be explained by the well known two-particle model. Unfortunately this model fails to provide a comprehensive description of the processes for 3D specimens. Furthermore, there is a significant discrepancy between the calculated and the measured shrinkage because particle rearrangements are not considered. Only the recently developed analysis of the particle movements inside of 3D specimens using micro focus computed tomography $({\mu}CT)$, combined with photogrammetric image analysis, can deliver the necessary experimental data to improve existing sintering theories. In this work, ${\mu}CT$ analysis was applied to spherical copper powders. Based on photogrammetric image analysis, it is possible to determine the positions of all particle centers for tracking the particles over the entire sintering process and to follow the formation and breaking of the particle bonds. In this paper, we present an in-depth analysis of the obtained data. In the future, high resolution synchrotron radiation tomography will be utilized to obtain in-situ data and images of higher resolution.

  • PDF

Application of a newly developed software program for image quality assessment in cone-beam computed tomography

  • de Oliveira, Marcus Vinicius Linhares;Santos, Antonio Carvalho;Paulo, Graciano;Campos, Paulo Sergio Flores;Santos, Joana
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.75-86
    • /
    • 2017
  • Purpose: The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. Materials and Methods: A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. Results: The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. Conclusion: This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

Utility of Brain Computed Tomography in Detecting Fractures of the Temporal Bones Correlated with Patterns of Fracture on High-Resolution Computed Tomography (고해상도 전산화 단층촬영에서 확인된 골절 유형에 따른 측두골 골절의 진단에서 뇌전산화 단층촬영의 유용성)

  • Kwon, Bong-Seok;Shin, Dong-Hyuk;Choi, Pil-Cho;Han, Sang-Kuk;Lee, Jeong-Hun;Song, Hyoung-Gon
    • Journal of Trauma and Injury
    • /
    • v.23 no.1
    • /
    • pp.38-42
    • /
    • 2010
  • Purpose: The clinical utility of brain computed tomography (CT) in detecting temporal bone fracture is not well established. We performed this study to determine the utility of brain computed tomography (CT) in detecting fractures of the temporal bones in correlation with fracture patterns. We used high resolution computed tomography (HRCT) as the gold standard for diagnosing temporal bone fracture and its pattern. Methods: From January 2007 to December 2009, patients who underwent both brain CT and HRCT within 10 days of head trauma were investigated. Among them, 58 cases of temporal bone fracture confirmed by HRCT were finally included. Fracture patterns (transverse or non-transverse, otic capsule sparing or otic capsule violating) were determined by HRCT. Brain CT findings in correlation with fracture patterns were analyzed. Results: Among 58 confirmed cases of temporal bone fracture by HRCT, 14 cases (24.1%) were not detected by brain CT. Brain CT showed a significantly lower ability to detect temporal bone fracture with transverse component than without transverse component (p=0.020). Moreover, brain CT showed lower ability to detect otic capsule violating pattern than otic capsule sparing pattern (p=0.015). Among the 14 cases of temporal bone fracture that were not detected by brain CT, 4 cases lacked any objective physical findings (facial palsy, hemotympanum, external auditory canal bleeding) suggesting fractures of the temporal bones. Conclusion: Brain CT showed poor ability to detect temporal bone fracture with transverse component and otic capsule violating pattern, which is associated with a poorer clinical outcome than otic capsule sparing pattern. Routine use of HRCT to identify temporal bone fracture is warranted, even in cases without evidence of temporal bone fracture on brain CT scans or any objective physical findings suggestive of temporal bone fracture.

Comparisons of the diagnostic accuracies of optical coherence tomography, micro-computed tomography, and histology in periodontal disease: an ex vivo study

  • Park, Jin-Young;Chung, Jung-Ho;Lee, Jung-Seok;Kim, Hee-Jin;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.30-40
    • /
    • 2017
  • Purpose: Optical coherence tomography (OCT) is a noninvasive diagnostic technique that may be useful for both qualitative and quantitative analyses of the periodontium. Micro-computed tomography (micro-CT) is another noninvasive imaging technique capable of providing submicron spatial resolution. The purpose of this study was to present periodontal images obtained using ex vivo dental OCT and to compare OCT images with micro-CT images and histologic sections. Methods: Images of ex vivo canine periodontal structures were obtained using OCT. Biologic depth measurements made using OCT were compared to measurements made on histologic sections prepared from the same sites. Visual comparisons were made among OCT, micro-CT, and histologic sections to evaluate whether anatomical details were accurately revealed by OCT. Results: The periodontal tissue contour, gingival sulcus, and the presence of supragingival and subgingival calculus could be visualized using OCT. OCT was able to depict the surface topography of the dentogingival complex with higher resolution than micro-CT, but the imaging depth was typically limited to 1.2-1.5 mm. Biologic depth measurements made using OCT were a mean of 0.51 mm shallower than the histologic measurements. Conclusions: Dental OCT as used in this study was able to generate high-resolution, cross-sectional images of the superficial portions of periodontal structures. Improvements in imaging depth and the development of an intraoral sensor are likely to make OCT a useful technique for periodontal applications.

Do Blebs or Bullae on High-Resolution Computed Tomography Predict Ipsilateral Recurrence in Young Patients at the First Episode of Primary Spontaneous Pneumothorax?

  • Park, Sungjoon;Jang, Hyo Jun;Song, Ju Hoon;Bae, So Young;Kim, Hyuck;Nam, Seung Hyuk;Lee, Jun Ho
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.91-99
    • /
    • 2019
  • Background: The relationship between the size of bullae and pneumothorax recurrence is controversial. The aim of this study was to retrospectively evaluate the role of blebs or bullae in predicting ipsilateral recurrence in young patients experiencing their first episode of primary spontaneous pneumothorax (PSP) who underwent conservative treatment. Methods: A total of 299 cases of first-episode PSP were analyzed. The status of blebs or bullae was reviewed on high-resolution computed tomography (HRCT). The dystrophic severity score (DSS; range, 0 to 6 points) was calculated based on HRCT. Results: The 5-year recurrence rate was 38.2%. In univariate analysis, age (<20 years), body mass index (<$20kg/m^2$), a unilateral lesion, and intermediate risk (DSS 4 and 5) were associated with recurrence. Sex; smoking history; and the presence, number, and maximal size of blebs or bullae were not related to recurrence. In Cox regression, age and intermediate risk were independent risk factors for recurrence. High risk (DDS 6) was not an independent risk factor. Conclusion: The presence, number, and size of blebs or bullae did not affect ipsilateral recurrence. DSS failed to show a positive correlation between severity and recurrence. The decision to perform surgery in patients experiencing their first episode of PSP should not be determined by the severity of blebs and bullae.

Optimizing the reconstruction filter in cone-beam CT to improve periodontal ligament space visualization: An in vitro study

  • Houno, Yuuki;Hishikawa, Toshimitsu;Gotoh, Ken-ichi;Naitoh, Munetaka;Mitani, Akio;Noguchi, Toshihide;Ariji, Eiichiro;Kodera, Yoshie
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.199-207
    • /
    • 2017
  • Purpose: Evaluation of alveolar bone is important in the diagnosis of dental diseases. The periodontal ligament space is difficult to clearly depict in cone-beam computed tomography images because the reconstruction filter conditions during image processing cause image blurring, resulting in decreased spatial resolution. We examined different reconstruction filters to assess their ability to improve spatial resolution and allow for a clearer visualization of the periodontal ligament space. Materials and Methods: Cone-beam computed tomography projections of 2 skull phantoms were reconstructed using 6 reconstruction conditions and then compared using the Thurstone paired comparison method. Physical evaluations, including the modulation transfer function and the Wiener spectrum, as well as an assessment of space visibility, were undertaken using experimental phantoms. Results: Image reconstruction using a modified Shepp-Logan filter resulted in better sensory, physical, and quantitative evaluations. The reconstruction conditions substantially improved the spatial resolution and visualization of the periodontal ligament space. The difference in sensitivity was obtained by altering the reconstruction filter. Conclusion: Modifying the characteristics of a reconstruction filter can generate significant improvement in assessments of the periodontal ligament space. A high-frequency enhancement filter improves the visualization of thin structures and will be useful when accurate assessment of the periodontal ligament space is necessary.