• Title/Summary/Keyword: High-resolution camera

Search Result 538, Processing Time 0.032 seconds

INITIAL GEOMETRIC ACCURACY OF KOMPSAT-2 HIGH RESOLUTION IMAGE

  • Seo, Doo-Chun;Lim, Hyo-Suk;Shin, Ji-Hyeon;Kim, Moon-Gyu
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.780-783
    • /
    • 2006
  • The KOrea Multi-Purpose Satellite-2 (KOMPSAT-2) was launched in July 2006 and the main mission of the KOMPSAT-2 is a high resolution imaging for the cartography of Korea peninsula by utilizing Multi Spectral Camera (MSC) images. The camera resolutions are 1 m in panchromatic scene and 4 m in multi-spectral imaging. This paper provides an initial geometric accuracy assessment of the KOMPSAT-2 high resolution image without ground control points and briefly introduces the sensor model of KOMPSAT-2. Also investigated and evaluated the obtained 3-dimensional terrain information using the MSC pass image and scene images acquired from the KOMPSAT-2 satellite.

  • PDF

Improvement of the Accuracy and Conveniency in Automated Strain Measurement through High-Resolution Image Processing (고해상도 화상처리를 통한 자동 변형률 측정의 정확도와 편의성 개선)

  • Kim, H.J.;Choi, S.C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.06a
    • /
    • pp.34-39
    • /
    • 2006
  • An automated surface-strain measurement system, named ASIAS, was developed by using the image processing and stereo vision techniques in the previous studies by the corresponding author and his coworkers. This system has been upgraded mainly to improve the accuracy through image enhancement, sub-pixel measurement, surface smoothing, etc., since the first version was released. The present study has still more improved the convenience of users as well as the accuracy of measurement by processing high resolution images 8 mega pixels or more which can be easily obtained from a portable digital steal camera. It is proved that high resolution image processing greatly decreases the measurement error and gives strain data without considerable deterioration of accuracy even when the deformed grids to be measured and the master grids for camera calibration are captured together in the same image, making the whole process of strain measurement much simpler.

  • PDF

Development of HD Resolution Stereoscopic Camera and Apparatus for Recognizing Depth of Object (HD 해상도 스테레오 영상 카메라 구현과 거리 인식 응용)

  • Han, Byung-Wan;Lim, Sung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.351-357
    • /
    • 2013
  • Two cameras which function like human eyes, are needed to make 3D stereoscopic image. That is, stereoscopic image is made via 3 dimensional image processing for combining two images from left and right camera. In this paper two high resolution zoom cameras are used to make HD resolution stereoscopic camera. And the algorithm which convert to stereoscopic image from HD resolution zoom camera image, is implemented using FPGA for real-time operation. The algorithm which measure the depth of object between left and right image is proposed.

Enhancement of Displacement Resolution of Vibration Data Measured by using Camera Images (카메라 영상을 이용한 진동변위 측정 시 측정해상도 향상 기법)

  • Son, Ki-Sung;Jeon, Hyeong-Seop;Han, Soon Woo;Park, Jong Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.716-723
    • /
    • 2014
  • Vibration measurement using image processing is a fully non-contact measurement method and has many application fields. The resolution of vibration data measured by image processing depends on the camera performance and is lower than that measured by accelerometers. This work discusses the method to increase resolution of vibration signal measured by image processing based on the image mosaic technique with a high-power lens. The working principle of resolution enhancement was explained theoretically and verified by several experiments. It was shown that the proposed method can measure vibrations of relatively large scale structures with increased resolutions.

HVCM (Hybrid Voice Coil Motor) Actuator apply performance improvement through the AUTO Focusing Camera Module (HVCM(Hybrid Voice Coil Motor) Actuator적용을 통한 AUTO Focusing Camera Module 성능개선)

  • Kwon, Tae-Kwon;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.307-309
    • /
    • 2011
  • The recently-released camera modules assembled into high-end handsets generally carry auto focusing function. The resolution size of the camera modules is getting higher, and customers demand more precise and stable auto focusing function. When auto focusing function is getting performed, the camera modules applied to VCM usually have the problems, which are an error of lens focusing position and resolution deviation according to the shift of one's position. For this reason, I propose Hybrid VCM that has an improved structure for a stable work of actuator and higher resolution level.

  • PDF

Research on the efficient illumination method in iris recognition at a distance (원거리 홍채 인식에서 효율적 조명 조사방법에 관한 연구)

  • Jo, Hyun-Su;Bae, Kwang-Hyuk;Park, Kang-Ryoung;Kim, Jai-Hie
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.969-970
    • /
    • 2008
  • This paper proposes illumination-efficient iris image capturing method. face capture method for extraction of iris pattern with one high resolution camera needs a large scale near infrared illumination. we replace high-resolution camera with co-optic-axial combination between wide view camera and narrow view camera. because this method needs small scale illumination that illuminate only narrow camera viewing angle, we can capture iris pattern image with small scale near infrared illumination.

  • PDF

DEVELOPMENT OF A HIGH SPEED CCD CAMERA SYSTEM FOR THE OBSERVATION OF SOLAR Ha FLARES

  • VERMA V. K.;UDDIN WAHAB;GAUR V. P.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.391-392
    • /
    • 1996
  • We have developed and tested a CCD camera (100 $\times$ 100 pixels) system for observing Ha images of the solar flares with time resolution> 25 msec. The 512 $\times$ 512 pixels image of CCD camera at 2 Mpixels/sec can be recorded at the rate of more than 5 frame/sec while 100 $\times$ 100 pixels area image can be obtained 40 frames/sec. The 100 $\times$ 100 pixels image of CCD camera corresponds to 130 $\times$ 130 arc - $sec^2$ of the solar disk.

  • PDF

High Resolution Analysis for Defective Pixels Detection using a Low Resolution Camera

  • Gibour, Veronique;Leroux, Thierry;Bloyet, Daniel
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.856-859
    • /
    • 2002
  • A system for high-resolution analysis of defective elementary cell (R, G or B) on Flat Panel Display (FPD) is described. Based on multiple acquisitions of low-resolution shifted images of the display, our system doesn't require a high-resolution sensor neither tedious alignment of the display, and will remain up to date even facing an important increase of the display dimensions. Our process, highly automated and thus flexible and robust, is expected to perform a full analysis in less than 60s. It is mainly intended for production tests and display classification by manufacturers.

  • PDF

Concept Design of Vibration Isolation System for Development of Optical Payload of Satellite (위성광학탑재체 개발을 위한 나노급 방진장치 개념 설계)

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Kim, Young-Key;Moon, Guee-Won;Moon, Sang-Moo;Kim, Hong-Bea
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.949-952
    • /
    • 2005
  • According to the national space program in Korea, is satellites will be launch into space up to 2015. Especially, KARI is going to develope of its own a high resolution camera of less than 1m to be mounted on next Multipurpose Satellite. When performing testing of large spacecraft or hardware that will be launched into orbit, it is necessary to conduct a testing with space-simulated environment. To achieve this requirement, thermal vacuum chamber is generally used. KARI has been developed a very Large Thermal Vacuum Chamber(LTVC) from 2003 to accomodate future space program, such as KOMPSAT, COMS, and Launch vehicles. This new facility will be used to qualify the first self developed High Resolution Camera, which will be loaded on KOMPSAT-3. To perform an optical test for space camera, it is necessary to provide vibration free environment. Thus the vibration responses on the optical table due to external vibration should be minimized by using a special isolation system. In this paper, we propose the concept design of vibration isolation system for the development of the high resolution camera.

  • PDF

Development of a real-time gamma camera for high radiation fields

  • Minju Lee;Yoonhee Jung;Sang-Han Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.56-63
    • /
    • 2024
  • In high radiation fields, gamma cameras suffer from pulse pile-up, resulting in poor energy resolution, count losses, and image distortion. To overcome this problem, various methods have been introduced to reduce the size of the aperture or pixel, reject the pile-up events, and correct the pile-up events, but these technologies have limitations in terms of mechanical design and real-time processing. The purpose of this study is to develop a real-time gamma camera to evaluate the radioactive contamination in high radiation fields. The gamma camera is composed of a pinhole collimator, NaI(Tl) scintillator, position sensitive photomultiplier (PSPMT), signal processing board, and data acquisition (DAQ). The pulse pile-up is corrected in real-time with a field programmable gate array (FPGA) using the start time correction (STC) method. The STC method corrects the amplitude of the pile-up event by correcting the time at the start point of the pile-up event. The performance of the gamma camera was evaluated using a high dose rate 137Cs source. For pulse pile-up ratios (PPRs) of 0.45 and 0.30, the energy resolution improved by 61.5 and 20.3%, respectively. In addition, the image artifacts in the 137Cs radioisotope image due to pile-up were reduced.