• 제목/요약/키워드: High-power Fuel Cell System

검색결과 265건 처리시간 0.024초

원통형 고체산화물 연료전지와 마이크로 가스터빈 하이브리드 시스템의 성능해석을 위한 모델링 (Modeling for the Performance Analysis of a Tubular SOFC/MGT Hybrid Power System)

  • 송태원;손정락;김재환;김동섭;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2070-2075
    • /
    • 2004
  • Performance of a solid oxide fuel cell (SOFC) can be enhanced by converting thermal energy of its high temperature exhaust gas to mechanical power using a micro gas turbine (MGT). A MGT plays also an important role to pressurize and warm up inlet gas streams of the SOFC. In this study, the influence of performance characteristics of the tubular SOFC on the hybrid power system is discussed. For this purpose, detailed heat and mass transfer with reforming and electrochemical reactions in the SOFC are mathematically modeled, and their results are reflected to the performance analysis. The analysis target is 220kWe SOFC/MGT hybrid system based on the tubular SOFC developed by Siemens-Westinghouse. Special attention is paid to the ohmic losses in the tubular SOFC counting not only current flow in radial direction, but also current flow in circumferential direction through the anode and cathode.

  • PDF

일체형 재생 연료전지(URFC)용 고분자 전해질 막의 이해 (Understanding of Polymer Electrolyte Membrane for a Unitized Regenerative Fuel Cell (URFC))

  • 정호영
    • 공업화학
    • /
    • 제22권2호
    • /
    • pp.125-132
    • /
    • 2011
  • 본 연구에서는 차세대 연료전지 기술로서 일체형 재생 연료전지(Unitized Regenerative Fuel Cell, URFC)에 대하여 검토하였다. URFC는 신재생 에너지원과 연료전지의 하이브리드 시스템 구현을 목적으로 하는 필수 기술이며 21세기 수소경제 사회 완성을 위한 신기술로 평가된다. 특히 본 연구에서는 URFC 요소 기술로서 고분자 전해질 막에 대한 연구 결과를 정리하여 URFC 기술의 이해를 돕고자 하는 것이 목적이다. URFC용 고분자 전해질 막은 기능적 특성상 높은 수소이온 전도도, 치수안정성, 기계적 물성 및 계면 안정성이 요구된다. 이를 바탕으로 미래 에너지원인 수소의 생산, 저장, 이용을 일체화된 시스템으로 완성시킬 수 있는 URFC 기술은 향후 연료전지 기술과 더불어 풍력과 태양광 발전 등의 신재생 에너지 관련 기술을 함께 발전시킬 수 있는 새로운 연구 분야가 될 것으로 판단된다.

Performance Analysis of SOFC/MGT Hybrid System

  • Kim, Jae-Hwan;Suzuki, Kenjiro
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.703-707
    • /
    • 2001
  • A performance analysis of a SOFC/MGT hybrid system has been carried out for concept design. Thermo-dynamic models for each component being able to describe electrochemical characteristics and heat and mate-rial balance are proposed. Estimated is the power capacity of a SOFC suitable for the hybrid operation with a 5kW class MGT. Effects of current density and operating pressure are also investigated. Electric efficiency showed weak dependence on operating pressure and current density. It is desirable that the SOFC operates at high current density in manufacturing cost's point of view though operating with high current density slightly decreases the electric efficiency find specific power.

  • PDF

대체에너지를 사용한 글라이더형 고고도 장기체공 무인항공기의 초기사이징 (Initial Sizing of a Glider Type High Altitude Long Endurance Unmanned Aerial Vehicle Using Alternative Energy)

  • 한혜선;김찬얼;황호연
    • 한국항공우주학회지
    • /
    • 제42권1호
    • /
    • pp.47-58
    • /
    • 2014
  • 본 연구에서는 대체에너지로 태양광과 수소재생연료전지를 사용하는 고고도 장기체공 무인기의 초기 사이징을 수행하였다. 박스 윙 형태의 형상 대신 해외에서 연구가 많이 진행되어 상대적으로 기본 자료들이 풍부한 글라이더 형태의 형상을 선택하였다. 이륙중량 150 kg 급으로 추진 시스템은 모터와 프로펠러, 태양광 전지, 전기분해를 통해 재충전이 가능한 액체수소 연료전지로 구성되어있다. 하루 동안 순항 비행 시 필요한 최소 요구 에너지와 낮 시간으로부터 얻을 수 있는 태양광 에너지와의 에너지 균형을 고려하여 가로세로비, 날개 길이, 면적 등 항공기 설계변수를 변화시키면서 전체 이륙중량을 추정하였다.

PEM 연료전지용 터보 블로워의 내구성에 관한 실험적 연구 (An Experimental Study on the Durability Test for PEM Fuel Cell Turbo-blower)

  • 이용복;이희섭;정진택
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.37-43
    • /
    • 2008
  • The durability test of turbo-blower for PEM fuel cell is very important process of BOP development. It is a major barrier to the commercialization of these systems for stationary and transportation power applications. Commercial viability depends on improving the durability of the air supply system to increase the reliability and to reduce the lifetime cost. In this study, turbo-blower supported by oil-free bearing is introduced as the air supply system used by 80kW proton exchange membrane fuel systems. The turbo-blower is a turbo machine which operates at high speed, so air foil bearings suit their purpose as bearing elements. The impeller of blower was adopted mixed type of centrifugal and axial. So, it has several advantages for variable operating condition. The turbo-blower test results show maximum parasitic power levels below 1.67kW with the 30,000 rpm rotating speed, the flow rate of air has maximum 163SCFM(@PR1.1). For proper application of FCV, these have to durability test. This paper describes the experiment for confirming endurance and stability of the turbo-blower for 500 hours.

소형/고효율 고분자전해질 연료공급모듈용 Air Blower 개발에 관한 연구 (Study on Air Blower for Air Management System)

  • 최준혁;정인성;김주한;서정무;허진;성하경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.212-214
    • /
    • 2006
  • Air Management System is composed by Pump, Fan, Compressor and Blower In general their performances depend on the capability of the motor, power converter device and controller. Especially, it should be noticed upon designing Air Management System using for Fuel Cell System, that Pump, Fan, Compressor and Blower satisfy the condition of the high performance, high efficiency, high density and reasonable price considering the safety and Economic Efficiency. In order for this, it should be studied that which kind of Motor is the most suited for Air Management System for Fuel Cell, such as Induction Motor, Brushless DC Motor, and Switched Reluctance Motor which is widely using in industry. This paper presents the designing and manufacturing of Outer Rotor Type BLDC Motor and Driver for Air Blower of Air Management System. Experimental results from a laboratory prototype arc presented to validate the feasibility of the proposed Air Blower Motor and Driver.

  • PDF

직접 개미산 연료전지의 연구동향 (R & D Trends on Direct Formic Acid Fuel Cells)

  • 권용재;한종희;김진수
    • 공업화학
    • /
    • 제19권6호
    • /
    • pp.583-591
    • /
    • 2008
  • 최근 휴대용 전자기기 수요의 급증에 따라 기존에 사용되던 2차 전지를 대체할 수 있는 친환경 고효율 연료전지 개발의 필요성이 증대되었다. 이러한 목적으로 개미산을 연료로 이용하는 직접 개미산 연료전지가 부각되고 있다. 식품첨가물로 사용될 정도의 안정성, 전해질을 통과하는 연료의 최소화된 crossover, 큰 기전력 발생에 의한 반응활성 최대화 등이 개미산이 가지고 있는 고유의 장점들이며, 이와 더불어 반응 촉매 및 전지 디자인을 최적화 하려는 노력에 의해 직접 개미산 연료전지의 성능 및 안정성이 향상되고 있다. 이러한 개발을 통해 현재까지 약 $300mW/cm^2$ 이상의 전력밀도를 나타내는 전지 개발이 이루어졌다. 본 총설에서는 개미산 연료전지의 기본 구동 원리와 전지 구조에 대한 소개 및 직접 개미산 연료전지 성능 향상에 영향을 미치는 인자들인 연료극 촉매 및 전해질 개발, 최적화된 전지 구조 디자인 등의 개발 현황 및 앞으로 나아갈 방향에 대해 논의하고자 한다.

직접탄소 연료전지에서 RDF 및 RPF의 전기화학반응 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Electrochemical Reactions of RDF/RPF in the Direct Carbon Fuel Cell)

  • 안성율;이영훈;엄성용;성연모;문철언;강기중;최경민;김덕줄
    • 한국수소및신에너지학회논문집
    • /
    • 제23권5호
    • /
    • pp.513-520
    • /
    • 2012
  • The electrochemical reaction of refuse derived fuel (RDF) and refuse plastic/paper fuel (RPF) was investigated in the direct carbon fuel cell (DCFC) system. The open circuit voltage (OCV) of RPF was higher than RDF and other coals because of its thermal reactive characteristic under carbon dioxide. The thermal reactivity of fuels was investigated by thermogravimetric analysis method. and the reaction rate of RPF was higher than other fuels. The behavior of all sample's potential was analogous in the beginning region of electrochemical reactions due to similar functional groups on the surface of fuels analyzed by X-ray Photoelectron Spectroscopy experiments. The potential level of RDF and RPF decreased rapidly comparing to coals in the next of the electrochemical reaction because the surface area and pore volume investigated by nitrogen gas adsorption tests were smaller than coals. This characteristic signifies the contact surface between electrolyte and fuel is restricted. The potential of fuels was maintained to the high current density region over 40 $mA/cm^2$ by total carbon component. The maximum power density of RDF and RPF reached up to 45~70% comparing to coal. The obvious improvement of maximum power density by increasing operating temperature was observed in both refuse fuels.

리니어 수소동력시스템의 연소연구용 급속흡입압축기의 특성 해석 (Analysis on the Characteristics of RICEM for Researching Combustion Characteristics of Linear Hydrogen Power System)

  • 이제홍;김강문;정대용;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제16권1호
    • /
    • pp.66-73
    • /
    • 2005
  • Hydrogen linear power system is estimated as the next generation power system which can obtain a performance as same as fuel cell. In order to develop Hydrogen combustion power system with high thermal efficiency, it is very important to understand the basic characteristics of hydrogen combustion and establish combustion stabilization technique of its system. In this study, RICEM(Rapid Intake Compression Expansion Machine) for researching of hydrogen combustion linear power system was manufactured and evaluated, and the basic characteristics of linear RICEM were analyzed.

미생물 연료전지에서 Fe[III] 환원 미생물 Geobacter sulfurreducens를 이용한 전기 생산 (Electricity Production from Fe[III]-reducing Bacterium Geobacter sulfurreducens in Microbial Fuel Cell)

  • 이유진;오유관;김미선
    • 한국수소및신에너지학회논문집
    • /
    • 제19권6호
    • /
    • pp.498-504
    • /
    • 2008
  • Metal-reducing bacterium, Geobacter sulfurreducens is available for mediator-less microbial fuel cell (MFC) because it has biological nanowires(pili) which transfer electrons to outside the cell. In this study, in the anode chamber of the MFC system using G. sulfurreducens, the concentrations of NaCl, sodium phosphate and sodium bicarbonate as electrolytes were mainly optimized for the generation of electricity from acetate. 0.4%(w/v) NaClO and 0.5M $H_2SO_4$ could be utilized for the sterilization of acrylic plates and proton exchange membrane (major construction materials of the MFC reactor), respectively. When NaCl concentration in anode phosphate buffer increased from 5 to 50 mM, power density increased from 6 to $20\;mW/m^2$. However, with increasing sodium phosphate buffer concentration from 5 to 50 mM, power density significantly decreased from 18 to $1\;mW/m^2$. Twenty-four mM sodium bicarbonate did not affect electricity generation as well as pH under 50 mM phosphate buffer condition. Optimized anode chamber of MFC using G. sulfurreducens generated relatively high power density ($20\;mW/m^2$) with the maximum coulombic efficiency (41.3%).