• 제목/요약/키워드: High-frequency inverter

검색결과 810건 처리시간 0.029초

유도전동기의 PWM제어와 누설 축전류 발생 모델링에 관한 연구 (A Study on Modeling of High-Frequency Leakage Currents in PWM Inverter Feeding an Induction Motor)

  • 이재호;임경내;전진휘;박성준;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.221-224
    • /
    • 1998
  • A PWM inverter with an induction motor often has a problem with a high-frequency leakage current that flows through the distributed electrostatic capacitance from the motor windings to ground. This paper presents an equivalent circuit for high-frequency leakage currents in PWM inverter feeding an induction motor, which forms an LCR series resonant circuit.

  • PDF

Hybrid 형 고주파 인버터의 특성 해석 (The Characteristic Analysis of Hibrid Type High Frequency Inverter)

  • 배진호;유동욱;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.113-116
    • /
    • 1988
  • In this paper, We Proposed a new Thyristor-FET hybrid type high-Frequency inverter circuit topology. Concerning the proposed high-frequency inverter. We applied the normalized parameters to the characteristic analysis of steady-state at the resistive load.

  • PDF

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

공진형 인버터를 이용한 2단 유도가열 시스템의 주파수제어에 관한 연구 (A Study on the Frequency Control on the Induction Heating System Using Two Step Resonant Inverter)

  • 유재훈;신대철
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.95-103
    • /
    • 2008
  • 제안한 유도가열 시스템은 증류탑 장치에 사용되는 특수충진체에 의한 열교환기술과 IH(Induction-Heating) 전자유도가열용의 특수한 고주파 전력회로 기술을 응용한 차세대 가열방식이다. 특히 일체의 연소과정이 없다는 점에서 작업환경의 개선이 가능하며 본 기술은 IGBT대응의 고주파 인버터를 사용하여 상용교류로부터 수[kHz]의 고주파교류(HFAC)를 발생시킬 수 있다. 본 논문에서는 1.5[kW]급 하프-브릿지 공진형 인버터 시스템과 공진부하의 동작해석, 특성분석 및 본 시스템을 이용한 2단 가열 과열증기 발생장치의 개발과 시스템의 응용에 대해 논하였다.

Sinewave-PWM ZVS Inverter using High-Frequency Transformer for Utility AC Voltage Link

  • Chandhaket S.;Ogura K.;Konishi Y.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.511-515
    • /
    • 2003
  • This paper presents a novel prototype of the utility-interfaced sinusoidal pulse width modulated (SPWM) inverter using the high-frequency flyback transformer fur the small-scale solar photo-voltaic power conditioner (1kW - 4kW). The proposed SPWM power conditioner circuit with a high-frequency link has a function of electrical isolation, which is vital fur solar photovoltaic power conditioner systems with the viewpoint of safety and convenience. The discontinuous conduction mode (DCM) operation of the flyback transformer is also maintained to simplify the topology of the inverter circuit and control scheme. First, the operating principle of the proposed circuit is described far the understanding of the circuit parameters establishment. Then, the digitally constructed SPWM control scheme is presented. The proposed circuit is verified by the computer simulation and the prototype experiment.

  • PDF

고역률을 가지는 Single-Stage Half-Bridge 고주파 공진 인버터 (High Power-Factor Single-Stage Half-Bridge High Frequency Resonant Inver)

  • 원재선;김동희;서철식;조규판;오승훈;정도영;배영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1196-1198
    • /
    • 2002
  • A novel single-stage half-bridge high frequency resonant inverter using ZVS(Zero Voltage Switching) with high input power factor suitable for induction heating applications is presented in this paper. The proposed high frequency resonant inverter integrates half-bridge boost rectifier as power factor corrector(PFC) and half-bridge resonant inverter into a single stage. The input stage of the half-bridge boost rectifier is working in discontinuous conduction mode (DCM) with constant duty cycle and variable switching frequency. So that a high power factor is achieved naturally. Simulation results through the Pspice have demonstrated the feasibility of the proposed inverter. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

누설 전류를 고려한 인버터 구동 유도 전동기 모델 시뮬레이션 (Simulations of the Inverter-Fed Induction Motor Model Considering Leakage Current)

  • 홍선기
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.70-76
    • /
    • 2010
  • 유도 전동기의 인버터 사용이 증가하면서, 인버터의 고주파 스위칭에 대한 유도전동기의 특성 해석 연구가 요구되고 있다. 그러나 기존의 연구들은 인버터와의 결합 모델의 개발 필요성을 느끼고 있으면서도 인버터 모델링의 어려움뿐만 아니라 결합 어려움 때문에 고정된 전원을 가정하고, 유도기 모델을 단순화 시켜서 모사를 하고 있는 경우가 대부분이다. 이에 인버터로 구동되는 유도 전동기의 고주파 해석 모델과 고주파 고려 유도 전동기 해석 모델 및 인버터 동작을 시뮬레이션할 수 있는 모델을 개발하여, 위와 같은 경우의 시뮬레이션을 가능하게 하고자 한다. 이로부터, 인버터에 의한 유도전동기 구동에서의 고주파에 의한 영향을 해석할 수 있다.

무전극 램프 구동용 영전압 스위칭 고주파 인버터에 관한 연구 (Zero-Voltage-Switching High Frequency Inverter for Electrodeless Fluorescent Lamp)

  • 박동현;김희준;조기연;계문호
    • 전자공학회논문지S
    • /
    • 제35S권8호
    • /
    • pp.113-119
    • /
    • 1998
  • 무전극 램프의 점등은 램프 양단에 고주파를 갖는 고전압을 인가해야 한다. 종래의 무전극 램프의 구동 회로로 선형 증폭기가 이용되어져 왔으나, 낮은 에너지 변환 효율로 인해 PWM 스위칭 방식의 인버터로 교체되고 있다. 그러나 고주파 스위칭시 인버터의 스위칭 소자에서 스위칭 손실의 증가 및 노이즈 발생의 문제로 인해 PWM 인버터는 고주파 동작이 제한된다. 이러한 문제점을 해결하기 위해 영전압 스위칭 기술을 PWM 인버터에 적용하여 고주파 스위칭이 가능하게 하고, 또한 스위칭 손실과 노이즈 발생을 줄일 수 있다. 본 논문에서는 무전극 램프 구동회로로 영전압 스위칭 고주파 인버터에 대하여 동작 해석과 설계 지침 제시하였다. 또한, 실험을 통하여 해석된 결과의 타당성을 확인하였다.

  • PDF

새로운 시분할 방식 전류형 고주파 인버터에 관한 연구 (A Study on the Novel Time Sharing Type Current Fad High Frequency Resonant Inverter)

  • 김해준;원재선;강진욱;조규판;오승훈;민병재;정도영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.27-30
    • /
    • 2003
  • This paper describes two novel current fed high frequency resonant inverter can be used as the power supp]y for wax-sealing. This two topology can be obtained higher output frequency than switching frequency by composing modified unit inverter based on conventional half-bridge serial resonant inverter in parallel with input power source. also, By using time-sharing gate control method, this proposed inverter can not only realize the output control of dependence irrespective of the switching frequency using phase-shift but also reduce switching loss because it has ZVS function. Simulation results through the Pspice have demonstrated the feasibility of the proposed inverter. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

태양광 마이크로 인버터를 위한 탭인덕터 부스트 및 강압형 컨버터 캐스케이드 타입 저가형 고효율 전력변환기 (Low-Cost High-Efficiency Two-Stage Cascaded Converter of Step-Down Buck and Tapped-Inductor Boost for Photovoltaic Micro-Inverters)

  • 장종호;신종현;박종후
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.157-163
    • /
    • 2014
  • This paper proposes a two-stage step-down buck and a tapped-inductor boost cascaded converter for high efficiency photovoltaic micro-inverter applications. The proposed inverter is a new structure to inject a rectified sinusoidal current into a low-frequency switching inverter for single-phase grid with unity power factor. To build a rectified-waveform of the output current. the converter employs both of a high efficiency step-up and a step-down converter in cascade. In step-down mode, tapped inductor(TI) boost converter stops and the buck converter operates alone. In boost mode, the TI converter operates with the halt of buck operation. The converter provides a rectified current to low frequency inverter, then the inverter converts the current into a unity power-factor sinusoidal waveform. By applying a TI, the converter can decrease the turn-on ratios of the main switch in TI boost converter even with an extreme step-up operation. The performance validation of the proposed design is confirmed by an experimental results of a 120W hardware prototype.