• Title/Summary/Keyword: High-field MR

Search Result 137, Processing Time 0.024 seconds

Numerical Study on the Sub-Voxel Tracking Using Micro-Beads in a 3.0 T MRI (3.0 T MRI 환경에서 마이크로비드를 이용한 서브복셀 추적에 관한 수치해석적 연구)

  • Han, Byung-Hee;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.102-107
    • /
    • 2007
  • In molecular imaging studies via magnetic resonance imaging, in vivo cell tracking is an important issue for the observation of cell therapy or disease behavior. High resolution imaging and longitudinal study are necessary to track the cell movement. Since the field inhomogeneity extends over several voxels, we have performed the numerical analysis using the sub-voxel method dividing a voxel of MR image into several elements and the information about the field inhomogeneity distribution around the micro-beads. We imbedded ferrite-composite micro-beads with the size of $20-150{\mu}m$ in the subject substituted for cells to induce local field distortion. In the phantom imaging with the isotropic voxel size of $200{\mu}m^3$, we could confirm the feasibility of sub-voxel tracking in a 3.0 T MRI.

A New Quadrature Breast RF Coil for MRI (새로운 자기공명영상촬영용 Quadrature Breast RF 코일)

  • Kim, S.K.;Yang, Y.J.;Lee, D.R.;Yi, Y.;Ahn, C.B.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.291-293
    • /
    • 1997
  • A new quadrature RF coil is designed for Breast MR Imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by "$\sqrt{2}$" using two orthogonal RF coils in combination. A modified Breast Quadrature coil is designed. It is a modified type of the high-pass birdcage coil. To reduce the field distortion, by using current feeding, the field pattern is optimized to achieve a quadrature circularly-polarized field pattern. The coil has been implemented for receive-only mode, and tested by phantom imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect (SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정)

  • 정준영
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

Clinical Applications of 3T MR Spectroscopy

  • Choe, Bo-Young;Baik, Hyun-Man;Chu, Myung-Ja;Jeun, Sin-Soo;Kang, Sei-Kwon;Chung, Sung-Taek;Park, Chi-Bong;Oh, Chang-Hyun;Lee, Hyoung-Koo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.345-351
    • /
    • 2002
  • The purpose of this study was to assess clinical proton MR spectroscopy (MRS) as a noninvasive method for evaluating brain tumor malignancy at 3T high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxe1 technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67${\pm}$018 and 1.16${\pm}$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (p=0.005), but Cho/Cr ratio of all tumor tissue was significantly higher (p=0.001). Cho/Cr ratio of high-grade gliomas was significantly higher than that of low-grade gliomas (P=0.001). Except 4 menigiomas, lactate signal was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. Our results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF

Magnetic field-induced deformation in ferromagnetic $Ni_{2}MnGa$ (강자성 $Ni_{2}MnGa$형상기억합금에서의 자장유기 변형)

  • 정순종;민복기;양권승
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.323-326
    • /
    • 2001
  • NI$_2$MnGa-based ferromagnetic shape memory alloys (FSMA) are hoped to be used as robust actuators with high performance and power density, as a replacement of other actuation materials such as thermo-mechanical SMAs and mechanical-electric piezoelectrics. Recently, we have observed significant shape changes under magnetic field application when single- and poly-crystalline forms are used. In the present study, two mechanisms have been proposed to predict the magnetic field-induced shape change as a function of external magnetic field at temperatures below Mr and above Ar. In the case of the field-induced shape change at temperature below M$_{f}$, paired martensite variants are assumed to form by application of magnetic field. The direction of magnetization in martensites formed in austenite matrix is assumed to be parallel to the applied magnetic field in the case of shape change by application at temperature above Af. Various energies has been considered in the shape change under two mechanisms.s.

  • PDF

Usefulness of the PRESS Technique using 3.0T Magnetic Resonance Spectroscopy for Evaluation of Non-Alcoholic Fatty Liver Disease Patients (비알콜성 지방간환자 평가를 위한 3.0T 고자기장 자기공명분광법을 이용한 PRESS 기법의 유용성)

  • Goo, Eun-Hoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5931-5936
    • /
    • 2012
  • This study was to evaluate the clinical usefulness of the PRESS technique based on the correlation between PRESS technique and biopsy results by applying 3.0T high magnetic field MRS technique for evaluation of non-alcoholic fatty liver disease patients. This experiment were carried out using a 3.0T magnetic resonance imaging equipment. The part data of each spectrum is taken by peak area integration. The part data of resonance peak was used to calculate relative ratio. MR spectral peak in patients with non-alcoholic fatty liver disease is from 0.9 to 1.6 ppm. According to MRS method study result, Patients with NAFLD were obtained with 94% sensitivity and 80% specificity(p=0.000). When compared to normal based on MRS and Biopsy results was valid correlation(r=0.79, p=0.04). Results for NAFLD(r=0.89, p=0.002) also showed a correlation. Therefore, PRESS technique to evaluate patients with non-alcoholic fatty liver disease, the distribution difference between normal liver and fatty liver part is significantly distinguished. Biopsy and MRS fatty liver peak ratio(%) proves high lipid over grade(r = 0.7).

Josephson Property and Magnetoresistance in Y$_1Ba_2Cu_3O_{7-x}$ and La$_{0.2}Sr_{0.8}MnO_3$ Films on Biepitaxial SrTiO$_3$/(MgO/)Al$_2O_3$(1120) (SrTiO$_3$/(MgO/)Al$_2O_3$(1120) 위에 쌍에피택셜하게 성장한 Y$_1Ba_2Cu_3O_{7-x}$와 La$_{0.2}Sr_{0.8}MnO_3$ 박막의 조셉슨 및 자기저항 특성연구)

  • Lee, Sang-Suk;Hwang, Do-Guwn
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.185-188
    • /
    • 1999
  • Biepitaxial Y$_1Ba_2Cu_3O_{7-x}$ (YBCO) and La$_{0.2}Sr_{0.8}MnO_3$ (LSMO) thin films have been prepared on SrTiO$_3$ buffer layer and MgO seed layer grown on Al$_2O_3$(11${\bar{2}}$0)substrates by dc-sputtering with hollow cylindrical targets, respectively. We charaterized Josephson properties and significantly large magnetoresistance in YBCO and LSMO films with 45$^{\circ}$ grain boundary junction, respectively. The observed working voltage (I$_cR_n$) at 77 K in grain boundary junction was below 10${\mu}$V, which is typical I$_cR_n$ value of single biepitaxial Josephson junction. The field magnetoresistance ratio (MR) of LSMO grain boundary juncoon at 77K was enhanced to 13%, which it was significant MR value with high magnetic field sensitivity at a low field of 250 Oe. These results indicate that inserting the insulating layer instead of the grain boundary layer with metallic phase can be possible to apply a new SIS Josephson junction and a novel magnetic device using spin-polarized tunneling junction.

  • PDF

Postmortem analysis of a failed liquid nitrogen-cooled prepolarization coil for SQUID sensor-based ultra-low field magnetic resonance

  • Hwang, Seong-Min;Kim, Kiwoong;Yu, Kwon Kyu;Lee, Seong-Joo;Shim, Jeong Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.44-48
    • /
    • 2014
  • A liquid nitrogen-cooled prepolarization ($B_p$) coil made for ultra-low field nuclear magnetic resonance and magnetic resonance imaging (ULF-MR) designed to generate 7 mT/A was fabricated. However, with suspected internal insulation failure, the coil was investigated in order to find out the source of the failure. This paper reports detailed build of the failed $B_p$ coil and a number of analysis methods utilized to figure out the source and the mode of failure. The analysis revealed that pyrolytic graphite sheet linings put on either sides of the coil for better thermal conduction acted as an electrical bridge between inner and outer layers of the coil to short out the coil whenever a moderately high voltage was applied across the coil. A simple model circuit simulation corroborated the analysis and further revealed that the failed insulation acted effectively as a damping resistor of $R_{d,eff}=6{\Omega}$ across the coil. This damping resistance produced a 50 ms-long voltage tail after the coil current was ramped down, making the coil not suitable for use in ULF-MR, which requires complete removal of magnetic field from $B_p$ coil within milliseconds.

Diffusion-Weighted MR Imaging of Various Intracranial Diseases : Clinical Utility (다양한 두개강내 질환의 확산강조 자기공명영상 : 임상적 유용성)

  • 김영준
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.104-112
    • /
    • 1998
  • Purpose : To evaluate the clinical utility of diffusion-weighted imaging by analyzing the signal intersity of lesions in patients with various intracranial diseases. Materials and Methods : difusion-weighted MR imaging was prospectively perormed in randomly selected 70 patients with various intracranial idseases. They consisted of 20 patients with acute infarct, 21 patients with chronic infarct of small vessel disease, 14 patients with primary intracranial tumor, three patients with brain metastasis, five patient with brain abscess, five patients with brain abscess, five patients with cerebral hemorrhage, one patient with neurocysticercosis, and one patient with epidermoid cyst. the diffusion-weighted images were obtained immediately after routine T2-weighted imaging on a 1.5T MR unit using single shot spin echo EPI technique with 6500 ms TR, 107ms TE, $128{\times}128$ matrix, 1 number of excitation, $24{\times}24$ field of view, 5-7 mm slice thickness, 2-3 mm inter-slice gap. The diffusion-gradients (b value of ($1000s{\;}/{\;}textrm{mm}^2$)) were applied along three directions(x, y, z). On visual inspection of diffusion-weighted images, the signal intersity of lesions was arbitrarily graded as one of 5 grades. In quantitative assessment, we measured the signal intensity of all the lesions and the contralateral corresponding normal area using round region of interest(ROI), and then calculated the signal intensity ratio of the lesion to the normal brain parenchyma. Results : On visual inspection, markedly hyperintense signals were seen in all cases of acute infarct, brain abscess, epidermoid cyst, and neurocysticercosis in degenerating stage. In all cases of cerebral hematoma, the very high signal internsity was intermingled with low signal intensity. focal very high signal intersity was also seen in a solid portion of the tumor in a patient. the mean signal intensity ratios of all those lesions to the normal brain parenchyma were above 2.5. Gliosis, solid component of brain tumor, brain metastasis, and vasogenic dedma appeared isointense to the normal brain parenchyma in 71%, 64%, 100%, and 67%, respectively ; the mean signal intensity ratios of those lesions to the normal brain parenchyma ranged 1.15 to 1.28 and there was no significant difference among these(p>0.1). Cystic cerebromalacia and necrotic or cystic portions in tumor were markedly or slightly hypointense, and the mean signal intensity ratios were 0.45 and 0.42, respectively. Conclusion : Very high signal intensity of acute infarct, brain abscess, epidermoid cyst, and cystic neurocysticercosis in degenerating stage on diffusion-weighted images may be helpful in differentiating from other diseases that are hypointense or isointense to the normal brain parenchyma. It may be especially useful differentiation of brain abscess from brain tumor with necrotic or cystic portion.

  • PDF

MR Characteristics of CoO based Magnetic tunnel Junction (CoO를 절연층으로 이용한 스핀 의존성 터널링 접합에서의 자기저항 특성)

  • 정창욱;조용진;안동환;정원철;조권구;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.4
    • /
    • pp.159-163
    • /
    • 2000
  • MR characteristics in magnetic tunnel junction using CoO as the oxide barrier were investigated. Spin-dependent tunnel junctions were fabricated on 4$\^$o/ tilt-cut (111)Si substrates in 3-gun magnetron sputtering system. The top and bottom ferromagnetic electrodes were Ni$\_$80/Fe$\_$20/(300 $\AA$) and Co(300 $\AA$), respectively. The oxide barriers (CoO) were formed by the thermal oxidation at room temperature in an O$_2$ atmosphere and the plasma oxidation. The increase of coercive field due to antiferromagnetic-ferromagnetic coupling has been observed in O$_2$plasma-oxidized CoO based junctions at room temperature. At a sensing current of 1 mA, MR ratios of O$_2$plasma-oxidized CoO based junction and thermal-oxidized CoO based junction at room temperature were 1% and 5%, respectively. Larger MR ratios are observed in magnetic tunnel juctions with thermal oxidized CoO when sensing current more than applied 1.5 mA. At a sensing current of 1.5 mA, we have observed MR value of 28 % and specific resistance (RA=R$\times$A) value of 10.9 ㏀$\times$$^2$. When specific resistance values reached 2.28 ㏀$\times$$^2$, we have observed that MR ratios become as high as 120%.

  • PDF