• 제목/요약/키워드: High-field MR

검색결과 137건 처리시간 0.025초

자기 공명 영상을 이용한 불균일 자계 측정 알고리즘 (Magnetic field Inhomogeneity measurement algorithm using magnetic resonance)

  • 강휴정;김치영;한수영;윤종호;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.2809-2811
    • /
    • 1999
  • In this paper, we develope an algorithm to calculate field inhomogeneity in MR imaging using a dual fast spin echo pulse sequence. Because phase modulation time can be easily modified with this pulse sequence, high resolution image can be obtained and acquisition time can be reduced compared to gradient echo technique. In the case of phase wrapping in field map, phase corrected using image processing technique. We assume the field pattern to be second order polynomial and apply Pseudo-Inverse equation to calculate second order polynomial coefficients. These coefficients can be used for the shimming of the magnetic field.

  • PDF

MR Gradient Echo 영상술에서 자화율에 의한 에러의 감소에 관한 연구 (Reduction of Susceptibility Artifact in MR Gradient Echo Imaging)

  • 노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.19-23
    • /
    • 1990
  • A new technique for reducing the susceptibility artifact in gradient echo imaging which uses a tailored RF pulse is proposed. It is applied to the case of imaging where artifacts and distortions arise due to the high local magnetic field inhomogeneity i. e., the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method using a tailored RF pulse is proposed. Applications of this method in imaging are given and experimental results obtained using an human volunteer with a 2.0 T KAIS NMR system are presented.

  • PDF

Spectroscopy of Intracellularly Located $%{133}Cs$ Has Been Used to Monitor the Uptake of the Isolated Rat Liver

  • Park Byung-Rae
    • 대한의생명과학회지
    • /
    • 제11권3호
    • /
    • pp.301-305
    • /
    • 2005
  • MR spectroscopy of intracellularly located $^{133}Cs$ has been used to monitor the uptake of Gd-EOB-DTPA by the isolated rat liver. As shown by ${31}P$ spectroscopy, accumulation of $^{133}Cs$ ions in hepatocytes does not produce detectable effects on the metabolism. The hepatic internalization of Gd-EOB-DTPA was followed by the paramagnetic relaxation enhancement of the intracellular $^{133}Cs$ ions, and confirmed by parallel quantitations of Gd and Cs run by inductively coupled plasma analysis of liver samples and aliquots of perfusate. Two peaks are observed at -22.0 and -23.5 ppm, with respect to the line of the external reference arbitarily set to 0 ppm. Upon rinsing of the extracellular compartment with regular K-H free of CsCl, the high-field resonance disappears within 20min. The intracellular concentration was confirmed by ICP, which gives a $Cs^+$ content of $22.0\pm3.5mM$. The relaxation data significantly underestimate the Gd content, suggesting a potential compartmentation of $Cs^+$ and the contrast agent.

  • PDF

Morphologic Assessment of Corpus Callosum in the Patient of Alzheimer Disease using Magnetic Resonance Imaging

  • Seoung, Youl-Hun;Choe, Bo-Young
    • 한국자기공명학회논문지
    • /
    • 제13권2호
    • /
    • pp.84-95
    • /
    • 2009
  • The purpose of this study was to evaluate the usefulness of the measurement of corpus callosum (CC) size in the Alzheimer patient by using magnetic resonance (MR) midsagittal image. We performed MR scanning in 20 normal high age group, and in 20 mild cognitive impairment (MCI) group, and in 20 Alzheimer disease (AD) group. The following parameters were employed in AD group: TRITE/FA 6650ms/66ms/$90^{\circ}$, NEX 2, Thickness/Gap 2/0, FOV 220mm. The magnetic field strength was used at 3.0 Tesla. We selected midsagittal image of the brain by using view forum program, measured CC size, which were anteroposterior length, diameter of genu, body, narrowing portion, and splenium. The present study demonstrates that CC size of Alzheimer disease can be useful for clinical assessment concerning the diameter of genu, body, and splenium.

Robust Image Similarity Measurement based on MR Physical Information

  • Eun, Sung-Jong;Jung, Eun-Young;Park, Dong Kyun;Whangbo, Taeg-Keun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권9호
    • /
    • pp.4461-4475
    • /
    • 2017
  • Recently, introduction of the hospital information system has remarkably improved the efficiency of health care services within hospitals. Due to improvement of the hospital information system, the issue of integration of medical information has emerged, and attempts to achieve it have been made. However, as a preceding step for integration of medical information, the problem of searching the same patient should be solved first, and studies on patient identification algorithm are required. As a typical case, similarity can be calculated through MPI (Master Patient Index) module, by comparing various fields such as patient's basic information and treatment information, etc. but it has many problems including the language system not suitable to Korean, estimation of an optimal weight by field, etc. This paper proposes a method searching the same patient using MRI information besides patient's field information as a supplementary method to increase the accuracy of matching algorithm such as MPI, etc. Unlike existing methods only using image information, upon identifying a patient, a highest weight was given to physical information of medical image and set as an unchangeable unique value, and as a result a high accuracy was detected. We aim to use the similarity measurement result as secondary measures in identifying a patient in the future.

자기유변유체를 이용한 반능동형 스퀴즈 필름 댐퍼의 해석 및 회전체 불균형 응답 제어 (Analysis of Magneto-rheological Fluid based Semi-active Squeeze Film Damper and Its Application to Unbalance Response Control of Rotor)

  • 김근주;이종원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1005-1011
    • /
    • 2004
  • Squeeze film dampers (SFDs) have been commonly used to effectively enhance the dynamic behavior of the rotating shaft supported by rolling element bearings. However, due to the recent trends of high operating speed, high load capacity and light weight in rotating machinery, it is becoming increasingly important to change the dynamic characteristics of rotating machines in operation so that the excessive vibrations, which may occur particularly when passing through critical speeds or unstable regions, can be avoided. Semi-active type SFDs using magneto-rheological fluid (MR fluid), which responds to an applied magnetic field with a change in rheoloaical behavior, are introduced in order to find its applications to rotating machinery as an effective device attenuating unbalance responses. In this paper, a semi-active SFD using MR fluid is designed, tested and identified by means of linear analysis to investigate the capability of changing its dynamic properties such as damping and stiffness. Furthermore, the proposed device is applied to a rotor system to investigate its potential capability for vibration attenuation: an efficient method for selecting the optimal location of the proposed damper is introduced and control algorithm that could improve the unbalance response properties of a flexible rotor is also proposed.

  • PDF

4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술 (Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet)

  • 문치웅;김상태;이대근;임태환;노용만;조장희;이윤
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.55-66
    • /
    • 1994
  • 4.7T의 고자장 자기공명 영상(Magnetic Resonance imaging : MRI) 장치에서 Tailored RF 경사자계반향(Tailored RF Gradient-Echo : TRGE)기법을 이용하여 phantom 영상과 고양이 뇌의 정맥혈관 영상을 얻었다. 증류수에 MgCl$_2$를 섞어 T1을 짧게한 지름 6cm의 원통형 phantom으로 TRGE기법에 대한 검증을 먼저 하였다. 이후 halothane으로 전신 마취된 몸무게 3.0~4.0kg의 고양이 뇌로부터 얻은 시단면(sagittal slice) 영상에서 Dorsal sagittal sinus, Straight sinus, Vein of corpus callosum과 Internal cerebral vein등의 혈관이 강조되어 나타남을 고양이 뇌의 해부학적 그림과 비교해 보였다. Tailored RF 파형은 ASPECT 3000 computer(스위스 BRUKER사 제품)의 PASCAL 언어를 이용하여 제작하였다. 사각형의 절편모양(slice profile)과 원하는 절편의 두께(slice thickness)에 선택절편내에서 절편방향으로 위상분포가 최대 2$\pi$가 되는 bi-linear ramp 모양을 갖는 절편함수를 공간상에서 Fourier 변환시켜 Tailored RF를 만들었다. TR/TE=205/10 msec, 절편두께 TH=7mm, 화소배열수(matrix size)=256$\times$256, 평면해상도(in-plane resolution)=0.62$\times$0.31mm$^2$, 관심영역 크기(field of view : FOV)=8cm의 영상조건으로 자기공명 TRGE 영상을 얻었다.

  • PDF

Electrical Transport and Magnetoresistance of La0.67Ca0.33MnO3: Agx (x = 0, 0.1, 0.2, 0.3, 0.4) Composites

  • Gencer, H.;Pektas, M.;Babur, Y.;Kolat, V.S.;Izgi, T.;Atalay, S.
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.176-184
    • /
    • 2012
  • The structural, magnetic and magnetotransport properties of $La_{0.67}Ca_{0.33}MnO_3$: $Ag_x$ (x = 0, 0.1, 0.2, 0.3 and 0.4) composites were investigated systematically. X-ray and EDX analysis indicated that Ag is not substituted into the main $La_{0.67}Ca_{0.33}MnO_3$ phase and remains an additive to the second phase at the grain boundary. The Curie temperature first decreased from 269 K for x = 0 to 257 K for x = 0.1 and then remained nearly unchanged with increasing Ag content. For the x > 0.1 samples, a second transition temperature ($T_{MI2}$) was observed in the resistance curves. At temperatures below 150 K, a significant enhancement in MR was observed while high temperature MR decreased with increasing Ag content. The maximum MR was observed to be 55% in the x = 0.4 sample at 10 K and a 6T magnetic field, this value is larger than that of pure $La_{0.67}Ca_{0.33}MnO_3$ (53% at 265 K and 6 T). In addition, at low fields (H < 1T), a sharp increase in the MR was observed.

자기공명검사 시 활력 징후의 변화 (Vital Signs Investigation in Subjects Undergoing Magnetic Resonance Imaging)

  • 정미애;최관우
    • 한국콘텐츠학회논문지
    • /
    • 제19권6호
    • /
    • pp.412-417
    • /
    • 2019
  • 본 연구는 고자장이란 특수성으로 인해 자기공명영상 검사 중 활력징후를 측정한 연구가 없는 상황에서 검사 중 활력징후를 측정하여 분석함으로서 폐소공포증의 원인분석을 위한 기초자료로 활용하고자 하였다. 연구 방법은 104명을 대상으로 MRI 검사 시 활력징후에 차이가 있는지 알아보기 위해 검사 전과 검사 중 활력징후를 측정하여 비교평가 하였다. 연구 결과, MRI 검사 시 심박수와 혈중산소포화도는 감소하였고, 수축기 혈압과 이완기 혈압 그리고 맥압은 증가하였으나, 모두 유의수준이 0.05이상으로 나타나 MRI 검사 중 활력징후의 변화는 검사 전과 통계적으로 유의한 차이가 없었다. 본 연구는 폐소공포증의 원인분석을 위한 기초자료 중 하나인 활력징후를 최초로 자기공명 검사 중 측정하여 제공하였다는데 의의가 있다.