• Title/Summary/Keyword: High-energy

Search Result 20,196, Processing Time 0.051 seconds

Nutrition Survey in Koje Island (거제도(巨濟島) 주민(住民)의 영양실태조사(營養實態調査))

  • Oh, Seoung-Ho;Chang, Soo-Kyung;Park, Michael Myung-Yun
    • Journal of Nutrition and Health
    • /
    • v.10 no.4
    • /
    • pp.43-58
    • /
    • 1977
  • Kojedo is the second largest island in Korea and a total population of 115,500 is living on the island of 394.69 sq. km. Under the direction of three nutrition professors, nutrition surveys in two villages in Kojedo, namely Siljun Ri in Hachung Myon and Soowol Ri in Shinhyun Myon, were carried by 30 college senior students majoring in nutrition from August to 20 August 1977. From a total of 176 households of the two villages, 67 households were randomly selected and 390 family members of the households were subjcets of the nutrition surveys. The precise weighing method was used in evaluating the kinds of foods and nutrient intakes of the subjects for three consecutive days. Thirty-seven pre-school children aged between 3 to 6 years and 27 fertile women were examined for biochemical findings and physical status. The main purposes of the surveys are to provide baseline data on nutrition in Kojedo Island for the Kojedo Community Development Project and to compare the nutritional status of the villages of Siljun Ri and Soowol Ri. Siljun Ri is located in the pilot project area of the Koiedo Community Health Project sponsored since December 1970 by the Christian Medical Commission of the World Council of Churches. While Soowol Ri is a control village for comparison. The results obtained are summarized as follows: Food Intake The average food intake per person per day in Siljun Ri, 1064 grams (91.7% in vegetable foods and 7.6% in animal foods) was 90 grams more than that of Soowol Ri, 974 grams (92.8% in vegetable foods and 5.9% in animal foods). However, the food intake per pre-school child in Siljun Ri, 485 grams (92.6% from vegetable foods and 6.4% from animal foods) was 21 grams lower than that of the Soowol Ri, 506 grams (88.5% from vegetable foods and 6.5% from animal foods). The average intake of beans was 16 grams(1.5% out of the total food intake) in Siljun Ri and 21 grams(2.2% of the total food intake)in Soowol Ri. The villagers should be guided for more consumption of soybeans to improve the quality of protein intake from vegetable foods. Nutrient Intake The adult intake in Siljun Ri and Soowol Ri were 2,529 kcal and 2,511 kcal respectively. The average energy intake of pre-school childen in Siljun Ri was 948 kcal and that for adult and 1,500 kcal for childen aged between 4 to 6 years-given by the Korea FAO Association, the diets in both villages were not adequate. Average daily protein intake of the subjected adult in Siljun Ri was 78.4 grams and that of Soowol Ri was 76.2 grams, while pre-school children took 30.7 grams in the former village and 31.7 grams in the latter village per child per day. The protein intake in both villages were lower than the recommended allowances, 80 grams for adult and 45 grams for $4{\sim}6$ years childen, and animal protein intake of the all subjects was very much lower than the RDA. The main charecter of the diet has been found low in quality of protein and high in carbohydrate. The calcium intakes of the pre-school children in both villages, 251.9 milligrams in Siljun Ri and 218.8 milligrams in Soowol Ri, were very much lower than the recommended allowance of 500 milligrams per day. It is apparent that the diet for children should be supplemented with calcium. Among the vitamin group, the daily average intakes of vitamin A and $B_{2}$(thiamine), $B_{2}$(riboflavin), C(ascorbic acid), and niacin were not adequate for the children in both villages. Especially the intake of riboflavin, 0.4 milligrams in both village children, was much lower than the RDA, 0.9 milligrams per day. Physical Characteristics Average height, weight, chest and head circumference of the pre-school children in both villages were similar to those of the Korean standard given by the Korean Paediatrics Association except that the average height of pre-school boys in Siljun Ri was 8 cm higher than the Korean standard of 105 cm. The mean values of upper arm circumference and skinfold thickness of pre-school boys in both villages were the same, 15.4 cm for upper arm circumference and 6.8 mm for skinfold thickness, but the mean values of those of the girls in Siljun Ri were higher than those of pre-school grils in Soowol Ri. Biochemical Findings Avera ge hemogobin value of boys and girls in both villages was the same, 11.1 grams per 100 ml of blood. The incidence of anemia (Hb value below 11g/100ml) was similar in both viltagesr 36.4% for boys and 50% for girls in Siljun Ri and 37.5% for boys and 50% for girls in Soowol Ri. Average hemoglobin values of fertile women were 10.7g% in Siljun Ri and 10.8% in Soowor Ri. The incidences of anemia(Hb valre brlow 12g/100ml) were 100% in Siljun Ri and 86.7% in Soowol Ri. The anemia of these subjects may be caused mainty low intake of good quality protein and iron intake from vegetable food. Recommendation In general, the nutritional status of a community health pilot village is not higher than that of control village due to the lack of nutrition improvement guldance services. Nutrition education should be delivered to the villagers as a main part of the health education artivities. The emphasis should be on building better health through bttter food habits and better food production as well as on preventing malnutrition and diseasrs. It can be an invaluable part of community developnent. Since nutrition is considered to be at least one-half of MCH care, no village or home visits should be made without careful provision for teaching and demoastrating something simple and practical on nutrition. The nurse, midwife, and village health worker should be the chief promoters of nutrition.

  • PDF

A study on the air pollutant emission trends in Gwangju (광주시 대기오염물질 배출량 변화추이에 관한 연구)

  • Seo, Gwang-Yeob;Shin, Dae-Yewn
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.1-26
    • /
    • 2009
  • We conclude the following with air pollution data measured from city measurement net administered and managed in Gwangju for the last 7 years from January in 2001 to December in 2007. In addition, some major statistics governed by Gwangju city and data administered by Gwangju as national official statistics obtained by estimating the amount of national air pollutant emission from National Institute of Environmental Research were used. The results are as follows ; 1. The distribution by main managements of air emission factory is the following ; Gwangju City Hall(67.8%) > Gwangsan District Office(13.6%) > Buk District Office(9.8%) > Seo District Office(5.5%) > Nam District Office(3.0%) > Dong District Office(0.3%) and the distribution by districts of air emission factory ; Buk District(32.8%) > Gwangsan District(22.4%) > Seo District(21.8%) > Nam District(14.9%) > Dong District(8.1%). That by types(Year 2004~2007 average) is also following ; Type 5(45.2%) > Type 4(40.7%) > Type 3(8.6%) > Type 2(3.2%) > Type 1(2.2%) and the most of them are small size of factory, Type 4 and 5. 2. The distribution by districts of the number of car registrations is the following ; Buk District(32.8%) > Gwangsan District(22.4%) > Seo District(21.8%) > Nam District(14.9%) > Dong District(8.1%) and the distribution by use of car fuel in 2001 ; Gasoline(56.3%) > Diesel(30.3%) > LPG(13.4%) > etc.(0.2%). In 2007, there was no ranking change ; Gasoline(47.8%) > Diesel(35.6%) > LPG(16.2%) >etc.(0.4%). The number of gasoline cars increased slightly, but that of diesel and LPG cars increased remarkably. 3. The distribution by items of the amount of air pollutant emission in Gwangju is the following; CO(36.7%) > NOx(32.7%) > VOC(26.7%) > SOx(2.3%) > PM-10(1.5%). The amount of CO and NOx, which are generally generated from cars, is very large percentage among them. 4. The distribution by mean of air pollutant emission(SOx, NOx, CO, VOC, PM-10) of each county for 5 years(2001~2005) is the following ; Buk District(31.0%) > Gwangsan District(28.2%) > Seo District(20.4%) > Nam District(12.5%) > Dong District(7.9%). The amount of air pollutant emission in Buk District, which has the most population, car registrations, and air pollutant emission businesses, was the highest. On the other hand, that of air pollutant emission in Dong District, which has the least population, car registrations, and air pollutant emission businesses, was the least. 5. The average rates of SOx for 5 years(2001~2005) in Gwangju is the following ; Non industrial combustion(59.5%) > Combustion in manufacturing industry(20.4%) > Road transportation(11.4%) > Non-road transportation(3.8%) > Waste disposal(3.7%) > Production process(1.1%). And the distribution of average amount of SOx emission of each county is shown as Gwangsan District(33.3%) > Buk District(28.0%) > Seo District(19.3%) > Nam District(10.2%) > Dong District(9.1%). 6. The distribution of the amount of NOx emission in Gwangju is shown as Road transportation(59.1%) > Non-road transportation(18.9%) > Non industrial combustion(13.3%) > Combustion in manufacturing industry(6.9%) > Waste disposal(1.6%) > Production process(0.1%). And the distribution of the amount of NOx emission from each county is the following ; Buk District(30.7%) > Gwangsan District(28.8%) > Seo District(20.5%) > Nam District(12.2%) > Dong District(7.8%). 7. The distribution of the amount of carbon monoxide emission in Gwangju is shown as Road transportation(82.0%) > Non industrial combustion(10.6%) > Non-road transportation(5.4%) > Combustion in manufacturing industry(1.7%) > Waste disposal(0.3%). And the distribution of the amount of carbon monoxide emission from each county is the following ; Buk District(33.0%) > Seo District(22.3%) > Gwangsan District(21.3%) > Nam District(14.3%) > Dong District(9.1%). 8. The distribution of the amount of Volatile Organic Compound emission in Gwangju is shown as Solvent utilization(69.5%) > Road transportation(19.8%) > Energy storage & transport(4.4%) > Non-road transportation(2.8%) > Waste disposal(2.4%) > Non industrial combustion(0.5%) > Production process(0.4%) > Combustion in manufacturing industry(0.3%). And the distribution of the amount of Volatile Organic Compound emission from each county is the following ; Gwangsan District(36.8%) > Buk District(28.7%) > Seo District(17.8%) > Nam District(10.4%) > Dong District(6.3%). 9. The distribution of the amount of minute dust emission in Gwangju is shown as Road transportation(76.7%) > Non-road transportation(16.3%) > Non industrial combustion(6.1%) > Combustion in manufacturing industry(0.7%) > Waste disposal(0.2%) > Production process(0.1%). And the distribution of the amount of minute dust emission from each county is the following ; Buk District(32.8%) > Gwangsan District(26.0%) > Seo District(19.5%) > Nam District(13.2%) > Dong District(8.5%). 10. According to the major source of emission of each items, that of oxides of sulfur is Non industrial combustion, heating of residence, business and agriculture and stockbreeding. And that of NOx, carbon monoxide, minute dust is Road transportation, emission of cars and two-wheeled vehicles. Also, that of VOC is Solvent utilization emission facilities due to Solvent utilization. 11. The concentration of sulfurous acid gas has been 0.004ppm since 2001 and there has not been no concentration change year by year. It is considered that the use of sulfurous acid gas is now reaching to the stabilization stage. This is found by the facts that the use of fuel is steadily changing from solid or liquid fuel to low sulfur liquid fuel containing very little amount of sulfur element or gas, so that nearly no change in concentration has been shown regularly. 12. Concerning changes of the concentration of throughout time, the concentration of NO has been shown relatively higher than that of $NO_2$ between 6AM~1PM and the concentration of $NO_2$ higher during the other time. The concentration of NOx(NO, $NO_2$) has been relatively high during weekday evenings. This result shows that there is correlation between the concentration of NOx and car traffics as we can see the Road transportation which accounts for 59.1% among the amount of NOx emission. 13. 49.1~61.2% of PM-10 shows PM-2.5 concerning the relationship between PM-10 and PM-2.5 and PM-2.5 among dust accounts for 45.4%~44.5% of PM-10 during March and April which is the lowest rates. This proves that particles of yellow sand that are bigger than the size $2.5\;{\mu}m$ are sent more than those that are smaller from China. This result shows that particles smaller than $2.5\;{\mu}m$ among dust exist much during July~August and December~January and 76.7% of minute dust is proved to be road transportation in Gwangju.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Primary Orbital Lymphoma : A Retrospective Analysis of Results of Radiation Therapy (원발성 안와 림프종의 방사선치료 성적에 관한 후향적 분석)

  • Kim Sussan;Ahn Seung Do;Chang Hyesook;Kim Kyoung Ju;Lee Sang-wook;Choi Eun Kyung;Kim Jong Hoon;Huh Jooryung;Suh Cheol Won;Kim Sung Bae
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.139-146
    • /
    • 2002
  • Purpose : This study evaluated the treatment outcomes, patterns of failure, and treatment related complications of primary lymphoma patients who received definitive radiation therapy. Materials and Methods : A retrospective analysis was undertaken for 31 patients with primary orbital lymphoma at the Asan Medical Center between February 1991 and April 2001. There were 18 males and 13 females with ages ranging from 3 to 73 years (median, 44 years). The involved sites were 9 conjunctivae, 12 eyelids and 10 other orbits. The histological types were 28 MALT lymphomas (low-grade B-cell lymphoma of mucosa-associated lymphoid tissue type), 1 diffuse large B-cell lymphoma, 1 anaplastic large cell lymphoma and 1 lymphoblastic lymphoma. The Ann Arbor stages were all IE $(100\%)$. Ann Arbor stage III or IV patients were excluded from this study, Bilateral orbital involvement occurred in 6 cases. Radiation therapy was given with one anterior port of high energy electrons $(6\~16\;MeV)$ for the lesions located at the anterior structures like the conjunctivae or eyelids. Lesions with a posterior extension or other orbital lesions were treated with 4 or 6 MeV photons with appropriately arranged portals. In particular, lens blocks composed of lead alloy were used in conjunctival or eyelid lesions. Twelve patients received chemotherapy. The median follow-up period was 53 months. Results : The 5-year overall, cause-specific, and disease-free survival was $91\%,\;96\%,\;and\;80\%$, respectively. The complete response rate 6 months after radiation therapy was $100\%$. Local recurrences were observed in 2 patients at 16 and 18 months after completion of radiation treatment. They were salvaged with additional radiation therapy. Two patients developed distant metastases. A MALT lymphoma patient with a lung relapse was successfully salvaged with radiotherapy, but the other lymphoblastic lymphoma patient with bone marrow relapse expired. There were no severe complications but 5 patients developed radiation-induced cataracts and 2 patients developed dry eye. Conclusion : Most primary orbital lymphomas consisted of MALT lymphomas. Radiation therapy was a successful treatment modality for orbital lymphoma without any severe complications. In cases of local relapses, radiation therapy is also a very successful salvage treatment modality.

Nutrient Intake Status of Male and Female University Students in Chuncheon Area (춘천지역 남녀 대학생들의 영양소 섭취 상태)

  • Kim, Yoon-Sun;Kim, Bok-Ran
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.12
    • /
    • pp.1856-1864
    • /
    • 2015
  • The purpose of this study was to investigate the nutrient intake status of university students in Chuncheon area (175 males and 131 females). This study was conducted by employing a self-administered questionnaire. Dietary assessment was measured by a 24-h recall method. The average height and weight of male students were $175.2{\pm}6.2cm$ and $68.2{\pm}9.9kg$, respectively. For female students, average values were $161.7{\pm}5.2cm$ and $55.1{\pm}6.5kg$, respectively. The mean BMIs for both male and female students were 22.2 and 21.1, respectively. In both male and female students, the rate of skipping breakfast was high. Daily averages for energy, carbohydrates, protein, and fat intakes in male students were significantly higher than those of female students (P<0.001). For male students, protein, vitamin B1, P, Fe, and Na were above recommended nutrient intake and adequate intake, whereas for female students, they were protein, vitamin A, P, and Na. For male students, nutrient intakes for Ca, vitamin $B_2$, vitamin C, and vitamin $B_6$ were below the estimated average requirement (EAR) by at least 50% or more, whereas for female students, they were vitamin C, Fe, vitamin $B_6$, vitamin $B_2$, niacin, folate, and Ca. Ca was alarmingly low, with more than 75% of both male and female students showing levels below the EAR. Therefore, it is important that nutritional education be facilitated for college students to take responsibility of their own health through learning about nutrient intake as well as developing positive eating habits.

Parotid Gland Sparing Radiotherapy Technique Using 3-D Conformal Radiotherapy for Nasopharyngeal CarcinomB (비인강암에서 방사선 구강 건조증 발생 감소를 위한 3차원 입체조형치료)

  • Lim Jihoon;Kim Gwi Eon;Keum Ki Chang;Suh Chang Ok;Lee Sang-wook;Park Hee Chul;Cho Jae Ho;Lee Sang Hoon;Chang Sei Kyung;Loh Juhn Kyu
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • Purpose : Although using the high energy Photon beam with conventional Parallel-opposed beams radiotherapy for nasopharyngeal carcinoma, radiation-induced xerostomia is a troublesome problem for patients. We conducted this study to explore a new parotid gland sparing technique in 3-D conformal radiotherapy (3-D CRT) in an effort to prevent the radiation-induced xerostomia. Materials and Methods : We peformed three different planning for four clinically node-negative nasopharyngeal cancer patients with different location of tumor(intracranial extension, nasal cavity extension, oropharyngeal extension, parapharyngeal extension), and intercompared the plans. Total prescription dose was 70.2 Gy to the isocenter. For plan-A, 2-D parallel opposing fields, a conventional radiotherapy technique, were employed. For plan-B, 2-D parallel opposing fields were used up until 54 Gy and afterwards 3-D non-coplanar beams were used. For plan-C, the new technique, 54 Gy was delivered by 3-D conformal 3-port beams (AP and both lateral ports with wedge compensator; shielding both superficial lobes of parotid glands at the AP beam using BEV) from the beginning of the treatment and early spinal cord block (at 36 Gy) was peformed. And bilateral posterior necks were treated with electron after 36 Gy. After 54 Gy, non-coplanar beams were used for cone-down plan. We intercompared dose statistics (Dmax, Dmin, Dmean, D95, DO5, V95, VOS, Volume receiving 46 Gy) and dose volume histograms (DVH) of tumor and normal tissues and NTCP values of parotid glands for the above three plans. Results : For all patients, the new technique (plan-C) was comparable or superior to the other plans in target volume isodose distribution and dose statistics and it has more homogenous target volume coverage. The new technique was most superior to the other plans in parotid glands sparing (volume receiving 46 Gy: 100, 98, 69$\%$ for each plan-A, B and C). And it showed the lowest NTCP value of parotid glands in all patients (range of NTCP; 96$\~$100$\%$, 79$\~$99$\%$, 51$\~$72$\%$ for each plan-A, B and C). Conclusion : We conclude that the new technique employing 3-D conformal radiotherapy at the beginning of radiotherapy and cone down using non-coplanar beams with early spinal cord block is highly recommended to spare parotid glands for node-negative nasopharygeal cancer patients.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Treatment Result of Ovarian Dysgerminoma (난소 미분화배세포종에 대한 방사선치료 결과)

  • Shin Seong Soo;Park Suk Won;Shin Kyung Hwan;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.379-385
    • /
    • 1997
  • Purpose : Ovarian dysgerminoma is a highly radiosensitive malignant tumor occurring in young age group. The conventional treatment was total abdominal hysterectomy and bilateral salpingo-oophorectomy followed by radiotherapy. We retrospectively analyzed the treatment results of Patients who had received radiotherapy in the era before chemotherapy was widely used. Material and Method : Twenty two patients with ovarian dysgerminoma were treated at the Department of Therapeutic Radiology, Seoul National University Hospital between August, 1980 and May, 1991. Four patients were excluded from this study, because three patients received incomplete treatment and one received combined chemotherapy. Sixteen patients received postoperative radiotherapy and two patients had radical radiotherapy as tumor was unresectable. Median follow-up period was 99 months (range, 51-178) Median age was 22 years (range, 11-42). Among the postoperatively treated patients, three Patients were in stage IA, eight in stage IC, two in stage II, and three in stage III. One patient had Turner's syndrome. Radiotherapy was performed with high energy photon (telecobalt unit or linear accelerator, either 6MV or 10MV), The radiation dose to the whole abdomen was 1950-2100cGy (median, 2000) and 1050-2520cGy was added to the whole pelvis, the total dose to the whole pelvis was 3000-4500cGy (median, 3500). Prophylactic Paraaortic area irradiation was done in six Patients (dose range, 900-1500cGy). One patient who had positive Paraaortic node, received radiation dose of 1620cGy, followed by additional 900cGy to the gross mass with shrinking field. Total dose to the paraaortic node was 4470cGy. Six patients, including one who had paraaortic node metastasis, received Prophylactic irradiation to mediastinum and supraclavicular area (2520cGy). Of the two patients with unresectable tumors who received radical radiotherapy, one was in stage III and the other was in stage IV with left supraclavicular lymph node metastasis. The stage III patient received radiation to the whole abdomen (2000cGy), followed by boost to whole pelvis (2070cGy) and paraaortic area (2450cGy). Stage IV patient received radiation to the whole abdomen (2000cGy), followed by radiation to the whole pelvis and paraaortic area (2400cGy), mediastinum (2520cGy) , and left supraclavicular area (3550cGy) .Results : The 5 year local control rate was $100\%$ in patients who received postoperative adiuvant radiotherapy after total abdominal hysterectomy and bilateral salpingo-oophorectomy. Only one patient in stage III who did not receive prophylactic irradiation to mediastinum developed mediastinal metastasis. but was salvaged by chemotherapy. So. the 5 year overall survival rate uras also $100\%$. Two patients who received radiation only, are alive without disease at 112 and 155 months. Conclusion : Postoperntive adjuvant radiotherapy as well as radical radiotherapy in unresectable ovarian dysgerminoma was very effective. aut chemotherapy is also an effective treatment modality We now recomrneifd chemotherapy for Patients who need to save their ovarian functien and reserve radiotherapv fov chemo-resistant tumor or recurrence alter che motherapy.

  • PDF

Removal of Red Tide Organisms -2. Flocculation of Red Tide Organisms by Using Loess- (적조생물의 구제 -2. 황토에 의한 적조생물의 응집제거-)

  • KIM Sung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.5
    • /
    • pp.455-462
    • /
    • 2000
  • The objective of this study was to examine the physicochemical characteristics of coagulation reaction between loess and red tide organisms (RTO) and its feasibility, in developing a technology for the removal of RTO bloom in coastal sea. The physicochemical characteristics of loess were examined for a particle size distribution, surface characteristics by scanning electron microscope, zeta potential, and alkalinity and pH variations in sea water. Two kinds of RTO that were used in this study, Cylindrothen closterium and Skeietonema costatum, were sampled in Masan bay and were cultured in laboratory. Coagulation experiments were conducted using various concentrations of loess, RTO, and a jar tester. The supernatant and RTO culture solution were analyzed for pH, alkalinity, RTO cell number. A negative zeta potential of loess increased with increasing pH at $10^(-3)M$ NaCl solution and had -71.3 mV at pH 9.36. Loess had a positive zeta potential of +1,8 mV at pH 1.98, which resulted in a characteristic of material having an amphoteric surface charge. In NaCl and $CaCl_2$, solutions, loess had a decreasing negative zeta potential with increasing $Na^+\;and\;Ca^(+2)$ ion concentration and then didn't result in a charge reversal due to not occurring specific adsorption for $Na^+$ ion while resulted in a charge reversal due to occurring specific adsorption for $Ca^(+2)$ ion. In sea water, loess and RTO showed the similar zeta potential values of -112,1 and -9.2 mV, respectively and sea sand powder showed the highest zeta potential value of -25.7 mV in the clays. EDLs (electrical double-layers) of loess and RTO were extremely compressed due to high concentration of salts included in sea water, As a result, there didn't almost exist EDL repulsive force between loess and RTO approaching each other and then LVDW (London-yan der Waals) attractive force was always larger than EDL repulsive force to easily form a floe. Removal rates of RTO exponentially increased with increasing a loess concentration. The removal rates steeply increased until $800 mg/l$ of loess, and reached $100{\%}$ at 6,400 mg/l of loess. Removal rates of RTO exponentially increased with increasing a G-value. This indicated that mixing (i.e., collision among particles) was very important for a coagulation reaction. Loess showed the highest RTO removal rates in the clays.

  • PDF