• Title/Summary/Keyword: High-altitude Electromagnetic Pulse (HEMP)

Search Result 23, Processing Time 0.027 seconds

A Study on the Measurement Method of Test Waveform for System-level HEMP Immunity Test (체계 수준 HEMP 내성 시험을 위한 시험파형 계측 기법 연구)

  • Yeo, Saedong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.233-240
    • /
    • 2019
  • High-altitude ElectroMagnetic Pulse(HEMP) is a high-power electromagnetic pulse caused by nuclear explosions at altitudes above 30 km. This pulse can cause serious damage to the electrical/electronic device. Therefore, there are a lot of studies on the effects of HEMP in the literature. When conducting studies on the effects of HEMP, it is essential to measure the simulated HEMP. Depending on the need for measurement, this paper focuses on the HEMP measurement method. This paper proposes a measurement method using frequency domain compensation to extract the correct waveform and solves the offset problem more efficiently than the conventional methods. The proposed method is verified by experiment using HEMP simulator and measurement system in ADD.

An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall for Shielding High-altitude Electromagnetic Pulse (HEMP) (고고도 전자기파(HEMP)차폐를 위한 전자파 차폐 콘크리트 벽체 개발에 관한 실험적 연구)

  • Choi, Hyun-Jun;Kim, Hyung-Chul;Lim, Sang-Woo;Lee, Han-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.169-177
    • /
    • 2017
  • Rather than causing damage from heat, blast, and radiation of a regular nuclear weapon, recently, it is predicted that North Korea has been inventing high altitude electromagnetic pulse (HEMP) missile in order to incapacitate electronic equipment. HEMP shielding facility is used for military purpose today. Despite the electromagnetic shielding effects from high quality compression plates, problems may include such as the possibility of electromagnetic influx resulting in the welding of the compression plates, and difficulties and high cost of construction. Therefore, in this study, a high electrical conducting material was added to the concrete experimental subject to ensure the shielding effect through electromagnetic waves to for the concrete structure, instead of building a shielding facility separately for the structure. Also, among the experimental subjects, 100 ${\mu}m$ of Iron-Aluminum alloy metal spraying coat was applied to two types with the highest shielding effect, and to two types with the lowest shielding effect. The result of the experiment indicates that experimental subjects added with a high electrical conductivity material did not meet the minimum shielding criteria of MIL-STD-118-125-1 standard, but all the experimental material applied to the metal spraying coating satisfied the minimum shielding criteria. In conclusion, it is considered that 100 µm of Iron-Aluminum alloy metal spraying coat contains high efficiency in the HEMP shielding.

A Study on Risk Assessments and Protection Improvement for Electric Power Infrastructures against High-altitude Electromagnetic Pulse (전력기반시설의 고 고도 핵 전자기파에 대한 위험성 검토 및 방호 개선방안 연구)

  • Chung, Yeon-Choon
    • Convergence Security Journal
    • /
    • v.19 no.3
    • /
    • pp.43-50
    • /
    • 2019
  • In a hyper-connected society, electric power infrastructures and information and communication infrastructures are the core of critical national infrastructures. However, electric power infrastructure is very deadly to high-frequency nuclear electromagnetic pulse (HEMP) threats recently issued by North Korea, so the resilience through rapid recovery after attack is directly related to the survivability of our country. Therefore, electric power infrastructure should take precedence over any other key infrastructure, with preemptive protection measures and fast recovery plans. In this paper, the characteristics of the HEMP threats was examined, and the risks and effective major protection measures of the electric power infrastructures are discussed. In the future, it is expected that it will be able to help establish the direction of enactment and revision of legal schems related to the 'high power EMP infringement prevention' for Korea's electric power infrastructures.

Measurement and Analysis of Antenna Induced Voltage for Tactical Mobile Wireless Communication System under HEMP Environment (HEMP 상황 하 전술기동무선통신체계 안테나 유도전압 측정 및 분석)

  • Park, Kyoung-Je;Jeong, Kil-Soo;Kim, Jung-Sup;Park, Yong-Woo;Park, Jae-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.30 no.2
    • /
    • pp.33-40
    • /
    • 2021
  • The situation of high-altitude electromagnetic pulses (HEMP) arises from high-altitude nuclear explosions. The HEMP situation can be simulated through the threat level investigation (TLI). In this paper, the induced voltage according to the antenna type of the tactical mobile radio communication system was measured and analyzed by TLI. Under the influence of HEMP, electronic equipment can be paralyzed or damaged. HEMP protection filters are commercially available for power lines and signal lines. However, commercialization of HEMP filters for antennas is insufficient, and even some of them exist for lightning protection. In order to make an appropriate HEMP protection filter according to the frequency and type of the antenna, the induced voltage was measured and the maximum induced voltage was analyzed through extrapolation. It was found that the measured induced voltage decreased as the frequency increased, such as in the HF, VHF and UHF bands of the measurement results.

An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall System Using Conductive Materials for Shielding High-altitude Electromagnetic Pulse(HEMP) (HEMP를 대상으로 한 도전성 재료 혼입 콘크리트 전자파 차폐 벽체 시스템 개발에 관한 실험적 연구)

  • Choi, Hyun-Jun;Choi, Hyun-Kuk;Kim, Jae-Young;Min, Tae-Beom;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.20-21
    • /
    • 2016
  • In this study, the shielding properties of concrete with conductive materials as shielding material for electromagne- tic pulse(EMP) within 10kHz~18GHz were investigated. The shielding effectiveness of specimens were compared with different entrained materials. The shielding effectiveness were determined according to MIL-STD-188-125-1, IEEE-STD-299 at 28 days of concrete curing. The results of shielding effectiveness did not meet the criteria(80dB) severely.

  • PDF

Analysis of Shielded Twisted Pair Cable to External Field Coupling by Expanded Chain Matrix Modeling

  • Cho, Yong-Sun;Jung, Hyun-Kyo;Cheon, Changyul;Chung, Young-Seek
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2049-2057
    • /
    • 2014
  • In this paper, a numerical method for analyzing coupling between high-altitude electromagnetic pulse (HEMP) as external field and a shielded twisted pair (STP) cable is proposed, which is based on an expanded chain matrix. Load responses of electromagnetic (EM) field excitation in uniform transmission line (TL) are solved by Baum-Liu-Tesche (BLT) equations in frequency domain, however, it is difficult to apply BLT equations to solve load responses of STP cable because the iteratively changing configuration of each twisted pairs are involved in cable. To avoid this problem and decrease memory and CPU time, we proposed the expanded chain matrix modeling method that is calculated using ABCD parameters, and applied multi-conductor transmission line (MTL) theory to consider the EMP coupling effectiveness of each twisted pairs. The results implemented by the proposed method are presented and compared with those obtained by the finite-difference time domain (FDTD) method as a kind of 3D full wave analysis.

The Characteristic of Electric Field Penetration into Infinite Conducting Plane with an Aperture Due to HEMP Incidence (HEMP 파원에 의한 무한 도체 평판 개구의 침투 전계 특성)

  • Lim, Byoung-Jin;Jung, Sung-Woo;Cho, Byung-Doo;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1454-1459
    • /
    • 2010
  • This paper presents the comparison of electric field penetration in Bell laboratories and IEC 61000-2-9 standard when HEMP source penetrates through an aperture in a planar conducting plane of infinite extent. HEMP electric field distributions assume in order to interpret this problem. Integral equation is derived and solved by Galerkin's method of moments for calculating the penetrating electric field. It is shown that penetrated electric field of IEC 61000-2-9 standard is greater than the Bell Laboratories waveform in resonance of lower frequency band, but those waveforms are similar in shape to frequency domain.

Analysis of Design Elements in HEMP Systems (HEMP 시스템의 설계 요소 분석)

  • Lee, Sun Yui;Kim, Jin Young;Park, Woo Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.6-11
    • /
    • 2013
  • In this paper, we explain the signal characteristics of HEMP and HEMP protection factors that affect the facilities are analyzed. We find the necessary elements of the physical facilities available for building. Shielding effects were measured by changing frequency and the distance of receiving antenna. Each measured value was compared to U.S. standard and measuring method was simplified. shielding effects were measured by three different conditions of shielding room. Find the difference between forward measurement and reverse measurement and factors which affects the measurement in shielding room.

Battery Based High Voltage Capacitor Charger for HEMP Driving (HEMP 구동을 위한 배터리 기반 고전압 충전기)

  • Cho, Chan-Gi;Jia, Ziyi;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.124-126
    • /
    • 2019
  • 본 논문은 리튬 폴리머 배터리를 기반으로 하여 High-altitude Electromagnetic Pulse (HEMP)를 구동하는 고전압 충전기의 2단 충전과 직접 충전 방법에 관하여 다룬다. 2단 충전 방법은 삼상 변압기의 출력 전압을 정류한 600 V의 전압에 공진 현상을 이용하여 최종 출력 전압 1.0 kV을 생성하는 반면, 직접 충전 방법은 공진 현상을 이용하지 않고 삼상 변압기의 출력 전압을 정류하여 1.0 kV를 생성한다. 두 방법 모두 1.0 kV의 출력 전압을 생성하는 점은 동일하지만, HEMP 구동을 위해서는 서로 다른 고려사항을 갖는다. 이에 따라, 시뮬레이션 및 기초 부하 실험을 통해 2단 충전 구조와 직접 충전 구조의 차이점, 그리고 충전기와 부하의 결선에 따른 차이점이 비교되었다.

  • PDF

HEMP Analysis and Shielding Effectiveness (HEMP 분석과 방호 효율성)

  • Lee, Sun Yui;Kim, Jin Young;Park, Woo Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.20-24
    • /
    • 2013
  • In this paper, we introduce a concept of HEMP systems and analyze a shielding effectiveness by varying placements of the antenna elements. Maxwell's equations for the high frequency of the EMP is represented in the LOS. In order to investigate the effects of electromagnetic attenuations, a shielding room was constructed and employed to obtain measured data. Shielding effects were measured by changing frequency and the distance of receiving antenna. Each measured value was compared to U.S. standard and measuring method was simplified. shielding effects were measured by three different conditions of shielding room. Find the difference between forward measurement and reverse measurement and factors which affects the measurement in shielding room.