수출형 KT-1 훈련기 고/저온 환경시험절차 적합화 연구 (A Study on the Tailoring of High / Low Temperature Test for KT-1 Trainer Export Version)

  • 김진석
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.78-86
    • /
    • 2020
  • The environmental tests are one of the key branches of the reliability tests. The purpose of the high/low environmental test of KT-1 Export Version Trainer is not only based on meeting the compliance of the reliability, customer satisfaction, but also for the expansion of its export. Amongst many existing environmental tests, the high and low temperature tests are considered as the two most important tests. The tests are considered and tailored to the high and low temperature methods of MIL-STD-810H. This paper proposes the tailoring processes and the results of High/Low temperature conditions, test procedures, and test profiles for the aircraft. Additionally, this paper is described by considering the view of MIL-STD-810H.

XKT-1T 항공기 환경 요구사항 적합화 연구 (A study on the Tailoring of Environmental Requirements for XKT-1T Aircraft)

  • 김진석
    • 시스템엔지니어링학술지
    • /
    • 제17권1호
    • /
    • pp.97-106
    • /
    • 2021
  • The purpose of the study on the tailoring of environmental requirements for KT-1 Export Version(XKT-1T) aircraft is not only based on meeting the compliance of the environmental reliability, customer satisfaction, but also for the expansion of its export. This paper proposes the environmental requirements tailoring processes and High/Low temperature conditions, test procedures, and the results of test profiles for the aircraft. Amongst many existing environmental requirements, the temperature requirements are considered as the most basic and the most important environmental requirements. The High/Low temperature tests are considered and tailored to the high and low temperature methods of MIL-STD-810.

XKT-1(수출형 KT-1) 항공기 열 환경시험에 관한 연구 (Study on Thermal Environmental Test for XKT-1 (KT-1 Export Version) Aircraft)

  • 김진석
    • 항공우주시스템공학회지
    • /
    • 제15권3호
    • /
    • pp.105-113
    • /
    • 2021
  • 본 논문은 MIL-STD-810 시험법 501(고온 시험법)과 시험법 502(저온 시험법)를 기반으로 XKT-1(수출형 KT-1) 항공기 고객의 운용 환경과 요구사항에 적합하도록 시험조건과 시험절차를 최적화하여 열 환경시험 프로파일을 제시하였다. 또한, 이렇게 최적화된 고온 및 저온시험 프로파일을 환경시험 종합평가 계획서에 반영하여 국방과학연구소의 기후환경 챔버에서 시험수행 하였다. 본 고온 및 저온 환경시험 프로파일로 XKT-1(수출형 KT-1) 항공기의 고온 및 저온 환경시험수행 결과, 고객 환경 요구사항을 만족하고 혹독한 열 환경에서 신뢰성 있음을 확인하였다. 특히 본 논문에서 제안된 고온 및 저온 환경시험절차와 프로파일은 더 혹독한 환경시험 조건의 수출형 항공기 환경시험에도 응용할 수 있다.

FA-50 경공격기 전기체 지상 고/저온시험 (Ground High/Low Temperature Test for FA-50 Aircraft)

  • 안종훈;김태호;우승철;조영균;김도완
    • 시스템엔지니어링학술지
    • /
    • 제6권1호
    • /
    • pp.41-46
    • /
    • 2010
  • The ground high/low temperature test objective is to check the normal ground operation of FA-50 aircraft in the extreme ground ambient conditions. The aircraft was exposed in climatic conditions of the basic climatic category according to the MIL-HDBK-310. For verified normal operation in the extreme high temperature, the high temperature test was performed in the hot regional type conditions and accentuated solar radiation heat. This test was performed at the test chamber in ADD where is in Haemi. This paper was described about the test procedure of FA-50 high/low temperature including preparation, testing and results.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

환경 및 신뢰성 시험분야를 위한 숙련도시험 시료개발 연구 (A Study on Proficiency Test Sample Development for Environmental & Reliability Testing Field)

  • 박경환;이철규
    • 품질경영학회지
    • /
    • 제45권3호
    • /
    • pp.447-462
    • /
    • 2017
  • Purpose: This study aims to develop distributable samples that can be used for proficiency testing to verify the ability of the testing laboratory to perform high temperature and low temperature tests. Method: In this study, the temperature-resistance characteristics of the NTC thermistor were used to develop samples. The homogeneity and stability of samples were examined according to the proficiency testing requirements. Results: Thirty samples with homogeneity and stability were developed and used for the proficiency testing. Thus, it was possible to distinguish between the test laboratories that showed satisfactory results and those that did not. Conclusion: It was the first time to develop samples that can be used for proficiency testing in high temperature and low temperature tests. and it was proved that the proficiency test program can be operated using the characteristics of NTC thermistor.

열화 주조 스테인리스강의 환경피로균열 진전 거동 (Environmental Fatigue Crack Propagation Behavior of Aged Cast Stainless Steel)

  • 정일석;이용성;김상재;송택호;조선영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.78-83
    • /
    • 2004
  • Environmental fatigue crack propagation of CF8M and CF8A steels used in the domestic PWR were investigated on the simulated PWR condition(Temperature: $316^{\circ}C$, Pressure: 15MPa). The test equipment for environmental fatigue(high temperature-high pressure loop, autoclave, load frame, measurement system) were designed. As-received and 60-year aged specimens were used in the test. To compare with environmental fatigue test, another test was performed in the air condition. The fracture surface of specimens were difficult to verify the fracture modes such as striation, intergranular crack and cleavage and so on. As the ferrite content of CF8M is increased, more particles covered fracture surface were peeled.

  • PDF

STRAIN RATE CHANGE FROM 0.04 TO 0.004%/S IN AN ENVIRONMENTAL FATIGUE TEST OF CF8M CAST STAINLESS STEEL

  • Jeong, Ill-Seok;Kim, Wan-Jae;Kim, Tae-Ryong;Jeon, Hyun-Ik
    • Nuclear Engineering and Technology
    • /
    • 제43권1호
    • /
    • pp.83-88
    • /
    • 2011
  • To define the effect of strain rate variation from 0.04% to 0.004%/s on environmental fatigue of CF8M cast stainless steel, which is used as a primary piping material in nuclear power plants, low-cycle fatigue tests were conducted at operating pressure and temperature condition of a pressurized water reactor, 15 MPa and $315^{\circ}C$, respectively. A high-pressure and high-temperature autoclave and cylindrical solid fatigue specimens were used for the strain-controlled low-cycle environmental fatigue tests. It was observed that the fatigue life of CF8M stainless steel is shortened as the strain rate decreases. Due to the effect of test temperature, the fatigue data of NUREG-6909 appears a slightly shorter than that obtained by KEPRI at the same stress amplitude of $1{\times}10^3$ MPa. The environmental fatigue correction factor $F_{en}$'s calculated with inputs of the test data increases with high strain amplitude, while the $F_{en}$'s of NUREG-6909 remain constant regardless of strain amplitude.

인코벨 690 증기발생기 세관의 고온 마모 거동 (High Temperature Wear Behavior of Inconel 690 Steam Generator tube)

  • 홍진기;김인섭;김형남;장기상
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.59-62
    • /
    • 2001
  • Flow induced vibration in steam generators has caused dynamic interactions between tubes and contacting materials resulting in fretting wear . Series of experiments have been performed to examine the wear properties of Inconel 690 steam generator tubes in various environmental conditions. For the present study, the test rig was designed to examine the fretting wear and rolling wear properties in high temperature(room temperature - 290。C) water. The test was performed at constant applied load and sliding distance to investigate the effect of test temperature on wear properties of the steam generator tube materials. To investigate the wear mechanism of material, the worn was observed using scanning electron microscopy. The weight loss increase at higher test temperature was caused by the decrease of water viscosity and the mechanical property change of tube material. The mechanical property changes of steam generator tube material, such as decrease of hardness or yield stress in the high temperature tests. From the SEM observation of worn surfaces, the severe wear scars were observed in specimens tested at the higher temperature.

  • PDF

필라멘트 와인딩 복합적층재의 환경가속 노화시험 평가 (Degradation Characteristics of Filament-Winding-Laminated Composites Under Accelerated Environmental Test)

  • 김덕재;윤영주;최낙삼
    • 대한기계학회논문집A
    • /
    • 제31권3호
    • /
    • pp.295-303
    • /
    • 2007
  • Degradation behaviors of filament-winded composites have been evaluated under the accelerated environmental test of high temperature, water immersion and thermal impact conditions. Two kinds of laminated composites coated by an urethane resin have been used: carbon-fiber reinforced epoxy(T700/Epon-826, CFRP) and glass-fiber reinforced phenolic (E-glass/phenolic, GFRP). For tensile strength of $0^{\circ}$ composites, CFRP showed little degradation while GFRP did high reduction by 25% under the influence of high temperature and water However for water-immersed $90^{\circ}$ composites tensile strength of both CFRP and GFRP showed high reduction. Bending strength and modulus of $90^{\circ}$ composites were largely reduced in water-immersion as well as high temperature environment. Urethane coating on the composite surface improved the bending properties by 20%, however hardly showed such improvement for water-immersed $90^{\circ}$ composites. In case of shear strength and modulus, both CFRP and GFRP showed high reduction by water-Immersion test but did a slight increase by high temperature and thermal impact conditions.