• 제목/요약/키워드: High-Speed Digital Interface

검색결과 101건 처리시간 0.026초

Picture archiving and communications systems development and performance results

  • Nam, Ji-Seung;Ralph Martinez
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1796-1800
    • /
    • 1991
  • Picture Archiving and Communication Systems(PACS) provide an integration of digital imaging information in a hospital, which encompasses various imaging equipment, viewing workstations, database archive systems, and a high speed fiber optic network. One of the most important requirements for integration is the standardization of communication protocols to connect devices from different vendors. Since 1985, the ACR-NEMA standard provides a hardware interface, a set of software commands, and a consistent set of data formats for point-to-point interconnection of medical equipment. However, it has been shown to be inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks has been suggested to the ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS's capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization / Open Systems Interconnection (ISO/OSI) protocols and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the proposed PACS protocol into network node. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The implementation has natural extentions to Global PACS environments. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance evaluation are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is performed on the PACS prototype node.

  • PDF

Implementation of an Embedded System for Image Tracking Using Web Camera (ICCAS 2005)

  • Nam, Chul;Ha, Kwan-Yong;;Kim, Hie-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1405-1408
    • /
    • 2005
  • An embedded system has been applied to many fields including households and industrial sites. In the past, user interface products with simple functions were commercialized .but now user demands are increasing and the system has more various applicable fields due to a high penetration rate of the Internet. Therefore, the demand for embedded system is tend to rise In this paper, we Implementation of an embedded system for image tracking. This system is used a fixed IP for the reliable server operation on TCP/IP networks. A real time broadcasting of video image on the internet was developed by using an USB camera on the embedded Linux system. The digital camera is connected at the USB host port of the embedded board. all input images from the video camera is continuously stored as a compressed JPEG file in a directory at the Linux web-server. And each frame image data from web camera is compared for measurement of displacement Vector. That used Block matching algorithm and edge detection algorithm for past speed. And the displacement vector is used at pan/tilt motor control through RS232 serial cable. The embedded board utilized the S3C2410 MPU Which used the ARM 920T core form Samsung. The operating system was ported to embedded Linux kernel and mounted of root file system. And the stored images are sent to the client PC through the web browser. It used the network function of Linux and it developed a program with protocol of the TCP/IP.

  • PDF

산업용 장비에서의 액추에이터를 제어 하기 위한 DSP에서의 Modbus통신 구현과 제어 모듈 개발 (Development of DSP-based Modbus Communication Scheme and Control Module for Controlling Actuators in Industrial Equipment)

  • 김원준;곽동기;김동환
    • 대한기계학회논문집A
    • /
    • 제41권11호
    • /
    • pp.1109-1117
    • /
    • 2017
  • PLC 시스템은 자체 모듈에 의한 부분적 확장성을 지원하고 있지만, 확장을 위한 비용이 크고, 센서 및 기타 제어기들과의 언어 호환성 또한 문제가 되고 있다. 본 논문에서는 빠르게 변화하는 기술에 대처하기 위해 텍사스 인스트루먼트 사의 DSP(디지털 시그널 프로세서)를 이용하여 PLC를 대체 및 보조할 수 있는 시스템을 제안한다. 이 시스템은 기존 PLC의 기능을 통합적으로 구현하며, 범용으로 쓰이는 PLC 에 비해 속도가 빠르고, 약 50% 이상의 비용 절감이 가능하다. 또한, 모듈 형태의 24V의 범용 디지털 I/O핀을 구성함으로써 선택적으로 입력과 출력의 부분적 확장을 용이하게 하였다. 일반적 산업 장비의 제어를 위해 널리 사용되고 있는 모드버스 통신을 RS-485 인터페이스를 기반으로 DSP에서 구현함으로써, 장비 간 다대다 통신을 할 수 있도록 하였다.

멀티채널 기가비트 CMOS 광 송신기 회로 (A Multi-Channel Gigabit CMOS Optical Transmitter Circuit)

  • 탁지영;김혜원;신지혜;이진주;박성민
    • 대한전자공학회논문지SD
    • /
    • 제48권12호
    • /
    • pp.52-57
    • /
    • 2011
  • 본 논문에서는 $0.18{\mu}m$ CMOS 공정을 이용하여 초고속 디지털 인터페이스 응용을 위한 4-채널 광 송신기를 구현하였다. 특히 VCSEL 드라이버 회로 내에 피드포워드 기법을 사용하였고, 프리앰프 회로 내에 펄스 폭 컨트롤 기법을 사용함으로써, 채널 당 2.5-Gb/s 동작속도를 가지며, 4mA의 바이어스 전류 및 $2{\sim}8mA_{pp}$의 모듈레이션 전류를 구동하고, 펄스 폭 왜곡을 줄이는 효과를 갖는다. 4-채널 광 송신기 어레이 칩의 면적은 $1.0{\times}1.7mm^2$ 이며, 단일 1.8V 전원전압에서 최대전류 구동 시 채널당 35mW의 낮은 전력을 소모한다.

무선랜 시스템을 위한 적응형 빔포밍 시스템의 설계 및 구현 (Design and Implementation of Adaptive Beam-forming System for Wi-Fi Systems)

  • 오주현;곽경훈;오영석;조성민;오혁준
    • 한국정보통신학회논문지
    • /
    • 제18권9호
    • /
    • pp.2109-2116
    • /
    • 2014
  • 본 논문은 무선랜 시스템에서 성능 향상을 위해, 안테나 빔을 전 방향으로 방사하는 기존의 방법과는 달리, 접속한 단말이 존재하는 방향으로만 안테나 빔을 방사하는 빔포밍 시스템을 설계 및 구현하였다. 해당 시스템은 패치형 배열 안테나를 통해 통신을 하며, DSP(Digital Signal Processor)에서 패킷 타입과 단말의 정보를 퀄컴사의 상용 칩으로부터 제공받아 FPGA(Field Programmable Gate Array)로 전송하는 방식으로 동작한다. DSP와 FPGA의 통신 방식은 데이터 송수신시 생기는 지연을 최소화하기 위해 PCI express(Peripheral Component Interconnect express)를 사용하였다. 단말 고유의 MAC(Media Access Control) 주소를 FPGA에서 저장하고 데이터베이스화함으로써 단말들의 위치를 관리할 수 있도록 하였다. 따라서 해당하는 단말로 패킷을 전송할 때, 추정한 위치로 빔을 방사하여 T/P(throughput)를 높일 수 있다. 단말의 위치는 패치형 배열 안테나를 통해 수신한 단말의 SINR(Signal to Interface plus Noise Ratio)을 프리앰블 구간에서 극대화하는 알고리즘을 사용하여 추정하였다. 제안하는 빔포밍 시스템을 Verilog HDL(Hardware Description Language)을 이용하여 FPGA와 퀄컴사의 상용 칩과 연동하여 구현하였으며 실제 운용 환경에서 시험을 통해 구현된 장비가 일반 AP(Access Point) 보다 더 높은 성능을 보이며 통신하는 것을 확인하였다.

실사기반 디지털 홀로그래픽 비디오의 실시간 생성을 위한 하드웨어의 설계 (A New Hardware Design for Generating Digital Holographic Video based on Natural Scene)

  • 이윤혁;서영호;김동욱
    • 전자공학회논문지
    • /
    • 제49권11호
    • /
    • pp.86-94
    • /
    • 2012
  • 본 논문에서는 고속으로 홀로그램을 생성할 수 있는 하드웨어의 구조를 제안하고 이를 구현하였다. 제안한 하드웨어는 홀로그램 평면의 행 단위로 병렬 연산을 수행할 수 있는 구조를 가지고 있고, 한 행의 각 홀로그램 화소들이 독립적으로 연산될 수 있는 알고리즘을 이용하였다. 이러한 연산 방법을 통해서 홀로그램 생성 하드웨어서 가장 문제가 되는 메모리 접근량을 대폭 감소시킴으로써 하드웨어 처리능력의 실시간성을 대폭 향상시켰다. 제안한 하드웨어는 입력 인터페이스, 초기 파라미터 연산기, 홀로그램 화소 연산기, 라인 버퍼, 그리고 메모리 제어기로 구성된다. 제안한 하드웨어는 기존의 하드웨어와 동일한 처리 능력을 가지면서도 메모리 접근횟수는 약 20,000배 감소시킬 수 있었다. 구현한 하드웨어는 198MHz에서 안정적으로 동작할 수 있었고, 168,960개의 LUT, 153,944개의 레지스터, 그리고 19,212개의 DSP 블록을 사용하였다.

방사선학과의 대학원 교육과정에 대한 연구 (Study of Graduate Curriculum in the Radiological Science : Problems and Suggestions)

  • 고성진;김화곤;강세식;박병래;김창수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.293-301
    • /
    • 2006
  • 최근의 의료방사선과학기술은 관련 환경의 발달로 의료산업과 융합하여 하루가 다르게 발전하고 있다. 이에 따라 학부와 대학원에서 방사선학교육과정이 개설됨에 따라 다른 학문 영역의 빠른 변화에 부응하여 다양한 프로그램으로 운영되고 있다. 그러나 국내 방사선학전공 분야의 대학원은 개설이 일천하여 교육 체계는 이에 부응하지 못하고 있는 실정이다. 현재 방사선과학의 교육과정은 기술과 학문으로서 인격 및 지식교육 그리고 보건의료전문인력으로서 기술 직업교육의 양대 큰 줄기를 병행하여 발전해야 한다는 명제로 볼 때 현 교육 환경과 임상이나 관련 산업에 적응하기에는 다소 무리가 있다. 특히 의료 환경의 변화와 이에 따른 교육과 연구가 다양화, 전문화, 세분화되고 있는 상황에서 방사선학 전공분야의 대학원 교육과정 개선과 바람직한 방향제시가 절실히 필요하다. 이러한 과정을 통하여 시대적, 사회적 요구에 부합하고 자질과 위상을 높일 수 있는 계기가 될 것으로 기대된다. 따라서 본 논문에서는 미국에서 현재 운영되고 있는 석사 및 박사과정의 대학원 교육과정을 분석하며, 현재 국내에서 개설 운용하고 있는 방사선학과 대학원 교육과정의 현황을 고찰하였고, 이를 기초자료로 하여 새로운 교육과정을 도입하기 위한 개선 방향을 제안하였다.

  • PDF

대한영상의학회 이러닝 센터 발전을 위한 노력: 대한영상의학회 회원 설문조사 (Efforts to Improve the E-Learning Center of the Korean Society of Radiology: Survey on User Experience and Satisfaction)

  • 정용은;김현철
    • 대한영상의학회지
    • /
    • 제83권6호
    • /
    • pp.1259-1272
    • /
    • 2022
  • 목적 이러닝 센터의 개선 사업을 위해 회원들에게 현재 이러닝 센터의 만족도 및 개선되어야 할 점에 대해 설문조사를 진행하고자 하였다. 대상과 방법 영상의학과 전문의(454/617명) 및 전공의(163/617명)를 대상으로 이메일로 설문조사를 진행하였다. 설문조사 문항은 근무처 등 기본적인 정보와 현재 이러닝 센터의 이용 빈도, 만족도, 만족/불만족 이유 및 기타 개선되었으면 하는 점 등으로 구성하여 조사하였다. 결과 연회원전용 이러닝의 경우 67%, 전체회원용 이러닝의 경우 42%가 평균 이상의 만족도를 보였다. 한 달에 5회 이상 이러닝을 이용하는 회원은 30% 정도였으며, 특히 전공의의 이용 빈도가 높았다. 원하는 강의를 찾기 어렵거나(연회원전용: n = 28/97, 전체회원용: n = 72/166), 원하는 주제의 강의가 없는 경우(연회원전용: n = 37/97, 전체회원용: n = 58/166)가 있어 이 부분에 대한 개선 요구가 있었으며, 강의가 주기적으로 업데이트되었으면 좋겠다는 의견이 있었다. 또한 이러닝 시스템의 사용 편의성 및 안전성 향상에 대한 의견들이 많았다. 결론 설문조사를 토대로 이러닝 강의의 양뿐만 아니라 질적 향상의 도모, 그리고 시스템의 안전성 및 편의성 증대를 기본 방향으로 이러닝 센터 개선작업을 진행할 계획이다.

선박안전 운항을 위한 이진 분할 알고리즘 기반 해상 객체 검출 하드웨어 가속기 설계 및 구현 (Design and Implementation of a Hardware Accelerator for Marine Object Detection based on a Binary Segmentation Algorithm for Ship Safety Navigation)

  • 이효찬;송현학;이성주;전호석;김효성;임태호
    • 한국정보통신학회논문지
    • /
    • 제24권10호
    • /
    • pp.1331-1340
    • /
    • 2020
  • 해상 객체 검출은 선장이 육안으로 해상 주변의 충돌 위험성이 있는 부유물을 컴퓨터를 통해 자동으로 검출하여 사람이 확인하는 방법과 유사한 정확도로 인지하는 방법을 말한다. 기존 선박에서는 레이더의 전파를 통해 해상 부유물의 유무와 거리를 판단하였지만 형체를 알아내어 장애물이 무엇인지는 판단할 수 없는 약점이 있다. 반면, 카메라는 인공지능 기술이 발달하면서 물체를 검출하거나 인식하는데 성능이 우수하여 항로에 있는 장애물을 정확하게 판단할 수 있다. 하지만, 디지털 영상을 분석하기 위해서는 컴퓨터가 대용량의 화소를 연산해야 하는데 CPU는 순차적 처리 방식에 특화된 구조이기에 처리속도가 매우 느려 원활한 서비스 지원은 물론 안전성도 보장할 수 없게 된다. 따라서 본 논문에서는 해상 객체 인식 소프트웨어를 개발하였고 연산량이 많은 부분을 가속화하기 위해 FPGA로 구현하였다. 또한, 임베디드 보드와 FPGA 인터페이스를 통해 시스템 구현 완성도를 높였으며 소프트웨어 기반의 기존 구현 방법보다 약 30배의 빠른 성능을 얻었고 전체 시스템의 속도는 약 3배 이상이 개선되었음을 확인할 수 있었다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF