• Title/Summary/Keyword: High-Rate Transmission

Search Result 1,217, Processing Time 0.028 seconds

Transmission Performance of Application Traffics on High Speed Railway Communications (고속철도통신에서 응용 트래픽의 전송성능)

  • Kim, Young-Dong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.771-776
    • /
    • 2017
  • LTE-R mobile communication technology based on LTE is used to supply various signal and exchange information required for safety operation of train on high speed railway communication system. In this paper, transmission performance of application traffic which is transferred on high speed communication based on LTE-R is analyzed. And some suggestions for application traffic transmission of high speed railway communication will be considered. Computer simulation is used to analyze performance of CBR, VBR as application traffic. Throughput, delay and packet loss rate is used as performance measurement and analysis parameters.

Antenna Selection Scheme Using Noncoherent Receivers for Off-Body High Data Rate WBAN (신체 외부 고속 통신에서 Noncoherent 수신기 기반의 안테나 선택 기법)

  • Park, Jong-Seok;Hwang, Jae-Ho;Jang, Sung-Jeen;Kim, Jae-Moung;Lee, Hyung-Soo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.88-97
    • /
    • 2009
  • As the development of wireless techniques, transmission technology of body area network plays an important role in realizing a welfare society by combining IT and BT when applying to vehicles. Off-body WBAN (Wireless Body Area Network) systems for video data transmission require low battery consumption and high data rate. To satisfy the requirement, UWB has been considered as a promising candidate for high rate WBAN. This paper introduces an antenna selection technique for ultra-wideband based off-body WBAN system with low complexity. In this paper, we propose an antenna selection scheme using non-coherent receiver for off-body high data rate WBAN system. The proposed receiver antenna selection method takes advantage of the characteristic of BPPM (Binary Pulse Position Modulation). With the property of BPPM, this scheme calculates the approximate SNR of the received signal with non-coherent receiver.

  • PDF

Wireless operational modal analysis of a multi-span prestressed concrete bridge for structural identification

  • Whelan, Matthew J.;Gangone, Michael V.;Janoyan, Kerop D.;Hoult, Neil A.;Middleton, Campbell R.;Soga, Kenichi
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.579-593
    • /
    • 2010
  • Low-power radio frequency (RF) chip transceiver technology and the associated structural health monitoring platforms have matured recently to enable high-rate, lossless transmission of measurement data across large-scale sensor networks. The intrinsic value of these advanced capabilities is the allowance for high-quality, rapid operational modal analysis of in-service structures using distributed accelerometers to experimentally characterize the dynamic response. From the analysis afforded through these dynamic data sets, structural identification techniques can then be utilized to develop a well calibrated finite element (FE) model of the structure for baseline development, extended analytical structural evaluation, and load response assessment. This paper presents a case study in which operational modal analysis is performed on a three-span prestressed reinforced concrete bridge using a wireless sensor network. The low-power wireless platform deployed supported a high-rate, lossless transmission protocol enabling real-time remote acquisition of the vibration response as recorded by twenty-nine accelerometers at a 256 Sps sampling rate. Several instrumentation layouts were utilized to assess the global multi-span response using a stationary sensor array as well as the spatially refined response of a single span using roving sensors and reference-based techniques. Subsequent structural identification using FE modeling and iterative updating through comparison with the experimental analysis is then documented to demonstrate the inherent value in dynamic response measurement across structural systems using high-rate wireless sensor networks.

The Study for the KOMPSAT-3 Image Data Compression

  • Lee S.G.;Lee S.T.
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.298-300
    • /
    • 2005
  • Satellite payload on-board date compression unit are use for saving date storage space and reducing time to transmit payload data to the ground station. The KOMPSAT-3 payload will generate higher data rate than KOMPSAT-2 due to its better ground sample distance capacity. High input data rate and limited output transmission data rate might lead excessive compression and degraded image quality. This paper presents a trade-off study about data storage capacity and compression parameters for estimated KOMPSAT-3 system.

  • PDF

Study on the measuring system of power quality for transmission system (송전계통의 전기품질 측정 시스템에 관한 연구)

  • Kim, Yeoung-Noh;Shin, Bong-Il;Lee, Hee-Chul;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho;Lee, Il-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.107-109
    • /
    • 2006
  • The additional matters appear to be considered in several aspects for building up power-quality measuring system of transmission system(high voltage system) compared to distribution system(middle or low voltage system). Like in distribution system, input signals are also received from PT and CT source of voltage and current respectively in transmission system and applied in accordance with a certain rate. In this case, very big error rate can be occurred according to the specification of the measuring system as the applying rate is bigger than in distribution system beyond comparison. In addition, when the abnormal signal occurred such as sag/swell, interruption, transient etc., power quality of other sites linked to the system also should be checked to find the accurate cause of the abnormal power-quality signals from the corresponding site. Accordingly, the accurate diagnosis on the condition of Power quality for the system depends on the way how the synchronization system is brought along for each site. This paper will suggest the solution for the most effective system building focused on how to solve the problem of the error rate and synchronization described in the above when building up the measuring system of power quality for transmission system.

  • PDF

Study on the measuring system of power quality for transmission system (송전계통의 전기품질 측정 시스템에 관한 연구)

  • Kim Yeoung-Noh;Shin Bong-Il;Lee Hee-Chul;Kwak No-Hong;Jeon Young-Soo;Park Sang-Ho;Lee Il-Moo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.432-434
    • /
    • 2006
  • The additional matters appear to be considered in several aspects for building up power-quality measuring system of transmission system(high voltage system) compared to distribution system(middle or low voltage system). Like in distribution system, input signals are also received from PT and CT source of voltage and current respectively in transmission system and applied in accordance with a certain rate. In this case, very big error rate can be occurred according to the specification of the measuring system as the applying rate is bigger than in distribution system beyond comparison. In addition, when the abnormal signal occurred such as sag/swell, interruption, transient etc., power quality of other sires linked to the system also should be checked to find the accurate cause of the abnormal power-quality signals from the corresponding. site. Accordingly, the accurate diagnosis on the condition of power quality for the system depends on the way how the synchronization system is brought along for each site. This paper will suggest the solution for the most effective system building focused on how to solve the problem of the error rate and synchronization described in the above when building up the measuring system of power quality for transmission system.

  • PDF

A Study on the Heat and Moisture Transport Properties of Vapor-Permeable Waterproof Finished Fabrics for Sports Wear (스포츠웨어용 투습방수직물의 열·수분이동 특성에 관한 연구)

  • Son, Bu Hun;Kim, Jin-A;Kwon, Oh Kyung
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.220-226
    • /
    • 2000
  • This study was to determine the characteristics of vapor-permeable waterproof finished fabric by the coating method. 4 different kinds of coating fabrics (A : wet, porous, polyurethane, B : dry, no porous, polyurethane, C : shape memory polyurethane and D : dry, porous polyurethane) were used, which were developed recently With this sample, moisture transport rate ($40^{\circ}C$, 45%RH & $40^{\circ}C$, 95%RH), changes of coating side's shape by washing times, water repellency rate, contracted length, qmax, heat conductivity, heat keeping rate, heat keeping rate with cotton, heat keeping rate on humidity temperature and humidity within clothing etc. were checked. And it was done in a climate chamber under $20{\pm}2^{\circ}C$, $65{\pm}5%RH$. The results of this study were as follow; In the moisture vapor transmission of sample B and C increased on high temperature and high humidity while sample A and D decreased, on this condition. Qmax rate had high relation with ground fabric's surface properties and the order was A>C>D>B. Heat conductivity had high relation with thickness and surface properties. Heat keeping rates on sweat condition showed around half percents of heat keeping rates on normal condition, but had no relation with moisture vapor transport rate. Changes of the fabric's properties by washing times were different in accordance with the construction of fabrics and the coating resin. Sample C had tow heat keeping rate on the high temperature and humidity and high heat keeping rate on the low temperature and humidity Moisture transport rate of vapor-permeable waterproof finished fabrics had high relation with the properties of ground fabrics on low humidity condition, but on the high humidity condition, it was highly related with the properties of coating resin.

  • PDF

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Spaceborne Data Link Design for High Rate Radar Imaging Data Transmission (고속 레이다 영상자료 전송을 위한 위성탑재 데이터 링크 설계)

  • Gwak, Yeong-Gil
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.117-124
    • /
    • 2002
  • A high speed data link capability is one of the critical factors in determining the performance of the spaceborne SAR system with high resolution because of the strict requirement for the real-time data transmission of the massive SAR data in a limited time of mission. In this paper, based on the data link model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath. The designed data link module can be effectively used for the spaceborne and airborne applications which requires to expand the high speed data link capability.

Effective Compensation of the Distorted 1.12 Tbps WDM Signals Using Optimization of Total Dispersion

  • Lee, Seong-Real
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.4
    • /
    • pp.377-381
    • /
    • 2007
  • Nonlinear effects and chromatic dispersion are the main causes of pulse degradation in high bit-rate WDM transmission systems and several architectures have been proposed to compensate them by means of optical phase conjugation. In this paper, a new method to exploit an optical phase conjugator (OPC) for nonlinearity and dispersion cancellation is disclosed. The proposed method is using optimal total dispersion of each fiber sections and it is simpler than those previously described in literature. Power penalty between WDM channels and the maximum launch power in $28{\times}40$ Gbps WDM transmission system designed by optimal total dispersion are more decreased and more increased than those in the conventional WDM transmission system with OPC, respectively. Furthermore, optimal total dispersion proposed in this research should provide the flexible design of WDM system, which less depends on OPC position.