• Title/Summary/Keyword: High-Dose

Search Result 4,233, Processing Time 0.043 seconds

High Energy Photon Beam Modeling Using Transport Theory for Calculation of Absorbed Dose Distribution (흡수 선량 분포의 수송방정식을 이용한 10 MV X-선의 모델)

  • Choi, Dong-Rak;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • A mathematical model is presented for the calculation of the depth absorbed dose in water Phantom irradiated by high energy Photon beam (10MV X-ray), based on transport theory. The parameters of this model are obtained from the experimental values which were simulated by non-linear regression process method. The calculated absorbed dose distribution is extended to 3-D by using trial function from beam profile field sizes, SSD and depth in water phantom irradiated by high energy Photon beam. The calculated values using this model are in good agreement with the measured values.

  • PDF

One Case of Esophageal Cancer Treated with High Dose Rate ICR (고 선량률 강내 치료기를 이용한 식도암 치험 1례)

  • Kim, Kyeung-Ae;Kim, Sung-Kyu;Shin, Sai-One;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.147-151
    • /
    • 1988
  • Esophageal cancers are highly malignant neoplasms. Prognosis of esophageal cancer treated by external irradiation alone is rather poor because of local recurrence and distant metastasis. Recently intracavitary irradiation has been used as a boost therapy after external irradation to optain better local control. One case of esophageal cancer has been treated by high dose rate remote-controlled afterloading unit as boost therapy after external irradiation. The result was excellent in short term follow up esophagogram but esophageal bleeding and esophagotracheal fistula were noted in further follow up examination after inappropriate posttreatment management including insufficient chemotherapy due to poor general condition. We reviewed possible causes of esophageal bleeding and esophagotracheal fistula after external irradiation and high dose rate ICR.

  • PDF

The Dielectric Properties of OPP film due to Irradiation Aging (방사선 열화에 따른 이축연신 폴리프로필렌 필름의 유전특성)

  • 오세원;조경순;김용주;김왕곤;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.80-84
    • /
    • 1993
  • In this research, we studied the variation of the dielectric loss absorption of the dielectric loss absorption of the sample according with the change to $\^$60/Co-${\gamma}$-ray irradiation dose of the influence of temperature and applied voltage. In order to investigate the effect of irradiation oriented polypropylene film, we have observed dissipation factor within the temperature range of 30∼130 [$^{\circ}C$] and voltage range of 100∼250$^{\circ}C$ [V]. As for the dependency of temperature by dissipation factor, the ${\alpha}$-peak which appears at high temperature increases accordingly to the increasement of irradiation dose which is contributed by the crystal region and moves towards the high temperature. The ${\beta}$-peak which appears at low temperature is origined from dipoles and molecular motions in the amorphous region. As for the dependency of voltage by tan$\delta$, at low temperature the peak of the tan$\delta$, at low temperature the peak of the tan$\delta$ shifts accordingly to the increasement of irradiation dose towards the high temperature region.

  • PDF

Decreased Pain Sensitivity of Capsaicin-Treated Rats Results from Decreased VR1 Expression

  • Lee, Soon-Youl;Hong, Young-Mi;Oh, Uh-Taek
    • Archives of Pharmacal Research
    • /
    • v.27 no.11
    • /
    • pp.1154-1160
    • /
    • 2004
  • We investigated the neurotoxic effects of capsaicin (CAP) on pain sensitivity and on the expression of capsaicin receptor, the vanilloid receptor (VR1), in rats. High-dose application of CAP has been known to degenerate a large fraction of the sensory neurons. Although the neurotoxic effects of CAP are well documented, the effects of CAP on the vanilloid receptor (VR1) are not yet known. In this paper, we investigated the effects of high-dose application of CAP on the expression of VR1 in rats. Thermal and mechanical pain sensitivity was reduced when neonatal rats were treated with a high dose of CAP. This reduction of pain sensitivity was significantly decreased after initiating carrageenan-induced inflammation. The expression of VR1 in dorsal root ganglia (DRG) isolated from the CAP-treated rats was reduced compared to that from the vehicle-treated rats. Therefore, we can conclude that the neurotoxic effect of CAP is related to the decrease of VR1 expression.

A Case of Successful Recovery from High Dose Intravenous Nicorandil Infusion in Refractory Coronary Vasospasm with Hemodynamic Collapse

  • Koh, Won-Jun;Cho, Jeong-Hyeon;Lee, Ji-Hyun;Kang, Won-Sik;Lee, Min-Kyung;Kim, Jun-Hyoung;Cho, Deok-Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.29 no.2
    • /
    • pp.129-131
    • /
    • 2012
  • A 70-year-old male came to the emergency room of the authors' hospital because of sudden cardiac arrest due to inferior wall ST elevation myocardial infarction. His coronary angiography revealed multiple severe coronary spasms in his very long left anterior descending artery. After an injection of intracoronary nitroglycerine, his stenosis improved. The cardiac arrest relapsed, however, accompanied by ST elevation of the inferior leads, while the patient was on diltiazem and nitrate medication to prevent coronary spasm. Recovery was not achieved even with cardiac massage, intravenous injection of epinephrine and atropine, and intravenous infusion of nitroglycerine. The patient eventually recovered through high-dose nicorandil intravenous infusion without ST elevation of his inferior leads. Therefore, intravenous infusion of a high dose of nicorandil must be considered a treatment option for cardiac arrest caused by refractory coronary vasospasm.

  • PDF

Effect of Hand Massage on Nausea, Vomiting and Anxiety in Childhood with Leukemia on Chemotherapy (백혈병 환아의 항암화학요법시 손마사지가 오심, 구토 및 불안에 미치는 효과)

  • Han Ji-Eun;Moon Young-Im;Park Ho-Ran
    • Child Health Nursing Research
    • /
    • v.11 no.4
    • /
    • pp.456-464
    • /
    • 2005
  • Purpose: To determine the effects of hand massage on nausea and vomiting, and anxiety in children with Iymphocytic leukemia receiving high dose chemotherapy. Method: The children were assigned to an experimental group(15) or a control group(15). All of the children were diagnosed with acute Iymphocytic leukemia and admitted for high dose chemotherapy at C University Medical Center in Seoul. The hand massage was performed for 10 minutes twice a day over three days. To measure the effects of hand massage, the Index of Nausea and Vomiting by Rhodes et al. and the State-Trait Anxiety Inventory for children by Spielberger were used. The level of anxiety was measured by systolic blood pressure, diastolic blood pressure, and pulse rate. Results: The score for nausea and vomiting decreased in the experimental group. State anxiety for the experimental group was significantly more positive than for the control group at the 2nd measurement. There was a significant difference in systolic blood pressure between the two groups. The level of diastolic blood pressure in the two groups decreased significantly over time. Conclusion: Hand massage could be effective in decreasing nausea and vomiting, state anxiety, pulse rate and blood pressure in children with acute leukemia receiving high dose chemotherapy.

  • PDF

Quality Assurance for High Dose Rate Brachytherapy (고선량율 근접치료의 정도관리)

  • Bang, Dong-Wan;Cho, Chung-Hee;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.30-44
    • /
    • 1998
  • Accurate delivery of doses using a high dose rate(HDR) brachytherapy, remote afterloading system(RALS) depends on knowing the strength of the radioactive source at the time of treatment, the precision and consistency of the timer, and the ability of the unit to position the source at the proper dwell location along the applicator. Periodic Quality Assurance(QA) on HDR machines is a part of the standard protocol of any user. The safety of the patient & staff, positional accuracy, temporal accuracy, and dose delivery accuracy are periodically(weekly, quarterly, monthly) estimated using HDR source(Ir-192), treatment planning devices, measurement devices, and overall treatment devices with regard to treatment delivery. The overall measurement results are estimated successfully and assessed its clinical significance. As a result, our HDR brachytherapy units has been very accurate until now. The QA program protocol permits routine clinical use and provides a high confidence level in the accurate operation of HDR units. Therefore, regular QA of HDR brachytherapy is essential for successful treatment.

  • PDF

Brachytherapy: A Comprehensive Review

  • Lim, Young Kyung;Kim, Dohyeon
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.25-39
    • /
    • 2021
  • Brachytherapy, along with external beam radiation therapy (EBRT), is an essential and effective radiation treatment process. In brachytherapy, in contrast to EBRT, the radiation source is radioisotopes. Because these isotopes can be positioned inside or near the tumor, it is possible to protect other organs around the tumor while delivering an extremely high-dose of treatment to the tumor. Brachytherapy has a long history of more than 100 years. In the early 1900s, the radioisotopes used for brachytherapy were only radium or radon isotopes extracted from nature. Over time, however, various radioisotopes have been artificially produced. As radioisotopes have high radioactivity and miniature size, the application of brachytherapy has expanded to high-dose-rate brachytherapy. Recently, advanced treatment techniques used in EBRT, such as image guidance and intensity modulation techniques, have been applied to brachytherapy. Three-dimensional images, such as ultrasound, computed tomography, magnetic resonance imaging, and positron emission tomography are used for accurate delineation of treatment targets and normal organs. Intensity-modulated brachytherapy is anticipated to be performed in the near future, and it is anticipated that the treatment outcomes of applicable cancers will be greatly improved by this treatment's excellent dose delivery characteristics.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Effects of Panax Ginseng on the Central Nervous System (인삼(人蔘)의 중추신경계(中樞神經系)에 대(對)한 작용(作用))

  • Oh, Jin-Sup;Park, Chan-Woong;Moon, Dong-Yeon
    • The Korean Journal of Pharmacology
    • /
    • v.5 no.1
    • /
    • pp.23-28
    • /
    • 1969
  • Saponin, essential oil and fat oil fractions were fractionated from Panax Ginseng and their potentiating or inhibiting actions during the combined use of several central nervous system stimulants or depressants were observed to elucidate the possible role of Ginseng fractions on the central nervous system. Saponin, essential oil and fat oil fractions shortened nembutal sleeping time at low dosage (10 mg/kg) but contrarily they produced potentiation of nembutal hypnosis at high dosage (50mg/kg). In the toxicity study of amphetamine, saponin and essential oil fractions reduced the toxicity in aggregated mice at high dosage (100 mg/kg) but such decreased lethality was not observed in isolated mice. Ginseng fractions, especially high dose of saponin fraction (100mg/kg) prolonged the survival time after injection of convulsive dose of metrazol or cocaine and saponin fraction also prolonged the onset of cocaine convulsion at high dosage (100 mg/kg).

  • PDF