• Title/Summary/Keyword: High-$T_{c}$

Search Result 4,287, Processing Time 0.039 seconds

Charge transport materials for the manufacture of OLEDs

  • Kathirgamanathan, Poopathy;Surendrakumar, S.;Ganeshamurugan, S.;Kumaraverl, M.;Paramaswara, G.;Partheepan, A.;Ravichandran, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.357-362
    • /
    • 2006
  • OLEDs are becoming established as a commercially viable flat panel display technology of choice of the $21^{st}$ century because of its lightweight, fast response time, lower thickness than LCD's and potentially low cost (1-2). For the OLEDs to function effectively, highly thermally stable materials, which offer high efficiency and long operational lifetimes are required. To achieve long lifetime, highly stable charge (both holes and electrons) transporters are essential. OLED-T provides these materials as well as fluorescent and phosphorescent dopants. This paper reports a unique patented hole injector (E9363) and an electron transporter (E246) that increases the lifetime and efficiency and reduces operating voltage. Further, an electron injector, EEI-101, which evaporates at a very low temperature of $300^{\circ}C$ as opposed to the conventional LiF, which requires $580^{\circ}C$, is also presented.

  • PDF

Effect of Microstructure and Cold Reduction Ratio on Spheroidization Rate and Mechanical Properties of High Carbon Steel (고탄소강 열연판재의 미세조직과 냉간압하율에 따른 구상화 속도 및 기계적 특성)

  • Lee, K.D.;Lee, S.Y.;Ha, T.K.;Jeong, H.T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.382-385
    • /
    • 2008
  • In the present study, the effect of cold reduction ratio on the spheroidization rate of SK85 high carbon steel sheet was investigated. High carbon steel sheet fabricated by POSCO was soaked at $850^{\circ}C$ for 2 hr in a box furnace and then treated at $570^{\circ}C$ and $670^{\circ}C$ for 10 min in a salt bath furnace followed by water quenching to obtain a fine pearlite structure and coarse pearlite structure. Cold rolling was conducted on the sheets by reduction ratios of 20, 30, and 40 % and heat treatment for spheroidization was carried out at $720^{\circ}C$ for the various time intervals from 1 to 32 hrs. Area fraction of spheroidized cementite was measured with an image analyzer as a function of cold reduction ratios and duration times.

  • PDF

Effect of Silicon on the Processing Window of High Carbon High Silicon Steels

  • Kim, Won-Bae;Ming, Xing;Moon, Yong-Min;Kim, Jong-Chul;Sohn, Ho-Sang;Ye, Byung-Joon
    • Journal of Korea Foundry Society
    • /
    • v.25 no.3
    • /
    • pp.123-127
    • /
    • 2005
  • 0.8wt.% C과 $0.75{\sim}3.2$(0.75, 1, 1.26, 1.44, 1.89, 2.1, 2.46, 2.94, 3.22)wt.% Si을 함유한 고탄소 고실리콘 강에서 Si의 함량이 미세조직과 processing window에 미치는 영향에 대해 조사하였다. 열처리는 $940^{\circ}C$에서 1시간 동안 오스테나이징을 실시한 후, $320^{\circ}C$에서 $0.2{\sim}300$분 동안 오스템퍼링을 하였다. 미세조직에서, 0.75 wt.% Si을 함유한 강에서 국부적으로 오스페라이트(ausferrite)가 존재하는 것을 확인하였다. Processing window는 경도 및 XRD 측정으로 결정하였다. $t_{1}$은 Si의 함량이 2.5 wt.% 이하에서는 거의 변화가 없다가,2.5 wt.% 이상에서는 감소하는 결과를 보였다. 반면, $t_{2}$는 Si의 함량이 증가함에 따라 연속적으로 증가하였다. 즉, 0.8 wt.% C을 함유한 강에서 processing window는 Si의 함량이 약 2.5 wt.%일 때 열렸다.

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

Fast and Low Temperature Deposition of Polycrystalline Silicon Films by Hot Wire CVD (Hot Wire CVD를 이용한 다결정 Si 박막의 고속 저온 증착)

  • Lee, Jeong-Chul;Kang, Ki-Whan;Kim, Seok-Ki;Yoon, Kyung-Hoon;Song, Jin-Soo;Park, I-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1427-1429
    • /
    • 2001
  • Polycrystalline silicon(poly-Si) films are deposited on low temperature glass substrate by Hot-Wire CVD(HWCVD). The structural properties of the poly-Si films are strongly dependent on the wire temperature($T_w$). The films deposited at high $T_w$ of 2000$^{\circ}C$ have superior crystalline properties; average lateral grain sizes are larger than $1{\mu}m$ and there at·e no vertical grain boundaries. The surface of the high $T_w$ samples are naturally textured like pyramid shape. These large grain size and textured surface are believed to give high current density when applied to solar cells. However, the poly-si films are structurally porous and contains high defect density, by which high concentration of C and O resulted within the films by air-penetration after removed from chamber.

  • PDF

Construction of a full-length cDNA library from Typha laxmanni Lepech. and T. angustifolia L. from an EST dataset

  • Im, Subin;Kim, Ho-Il;Kim, Dasom;Oh, Sang Heon;Kim, Yoon-Young;Ku, Ja Hyeong;Lim, Yong Pyo
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.4
    • /
    • pp.583-590
    • /
    • 2018
  • Genus Typha L. (Typhaceae; Cattail in common) is one of the hydrophytic plants found in semi-aquatic regions. About nine to 18 species of the genus exist all over the world. In Korea, the most commonly found cattail species are T. laxmanni and T. angustifolia. The aim of this study was to prepare a cDNA library and sequences and analyze expressed sequence tags (ESTs) from these species, T. laxmanni and T. angustifolia. In the case of T. laxmanni, we observed that 715 out of 742 ESTs had high quality sequences, whereas the remaining 27 ESTs were low quality sequences. In this study, we identified 77 contigs, 393 unassembled clones and 65.7% singletons. Furthermore, in the case of T. angustifolia, we recorded 992 high quality EST sequences, and by excluding 28 low quality sequences from among them, we retrieved 120 contigs, 348 unassembled clones and 48.9% singletons. The basic local alignment search tool (BLAST) and Kyoto encyclopedia of genes and genomes (KEGG) database results enabled us to identify the functional categories, i.e., molecular function (16.5%), biological process (22.2%) and cellular components (61.3%). In addition, between these two species, the no hits and anonymous genes were 4.2% and 11.7% and 6.2% and 11.2% in T. laxmanni and T. angustifolia, respectively, based on the BLAST results. The study concluded that they have certain species-specific genes. Hence, the results of this study on these two species could be a valuable resource for further studies.

Improvement of Insulin Resistance by Curcumin in High Fat Diet Fed Mice (고지방식이 급여 마우스에서 curcumin의 인슐린 저항성 개선 효능)

  • Kim, Dan Bi;Ahn, Eunyeong;Kim, Eunjung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.315-323
    • /
    • 2018
  • Rapid increase of diabetic population is a major health concern in Korea. In a trial to develop food components which can prevent and/or cure diabetes, we investigated the anti-diabetic activity of curcumin in high fat diet (HFD)-induced type 2 diabetes mellitus (T2DM) animal model. C57BL/6 mice were divided into three groups: normal diet (ND), high fat diet (HFD), and curcumin (CUR, HFD+0.02% curcumin). Mice were fed each diet for 16 weeks. CUR significantly reduced body weight gain, the levels of plasma glucose, insulin, total-cholesterol (T-C), and LDL-C, whereas increased HDL-C compared to those of HFD group. Notably, insulin signaling pathway was activated by CUR. This suggests that CUR improves obesity-associated T2DM by overcoming insulin resistance in part.

Pressure Effects on the Dehydration Behavior of Natrolite (나트로라이트 탈수현상의 압력의존성에 관한 연구)

  • Hwang, Gil Chan;Jang, Young-Nam;Liu, Zhenxian;Lee, Yongjae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.175-187
    • /
    • 2013
  • In-situ Raman and X-ray diffraction experiments have been performed on mineral natrolite (Na-zeolite) to investigate the dehydration behavior under high temperature and high pressure-temperature conditions. XRD data show reversible dehydration up to $450^{\circ}C$ whereas Raman data show irreversible change when the material is heated up to $630^{\circ}C$. The existence of post-natrolite was newly identified to form from ${\beta}$-metanatrolite at $380^{\circ}C$ upon cooling. The formation of dehydrated metanatrolite under simultaneous high temperature-pressure (room temperature < T < $300^{\circ}C$, 0 GPa < P < 2.1 GPa) conditions was not observed.

HVOF Spray Coating of Co-alloy(T800) for the Improvement of durability of High Speed Spindle (초고속 회전체의 내구성향상을 위한 Co-alloy(T800)의 초고속 용사코팅)

  • Cho, Tong-Yul;Yoon, Jae-Hong;Kim, Kil-Su;Youn, Suk-Jo;Back, Nam-Ki;Park, Byung-Chul;Chun, Hui-Gon
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.32-37
    • /
    • 2006
  • Micron size Co-alloy(T800) powder was coated on Inconel 718 by HVOF thermal spraying for the studies of the improvement of durability of high speed spindle by using Taguchi program for the parameters of spray distance, flow rates of hydrogen and oxygen and powder feed rate. The optimal coating process was determined by the studies of coating properties such as micro-structure, porosity, surface roughness and micro hardness. Friction and wear behaviors of coatings were investigated by sliding wear test at room temperature and $1000^{\circ}F(538^{\circ}C)$. At both room temperature and $538^{\circ}C$ the sliding wear debris and friction coefficients of the coating were drastically reduced compared with the surface of non-coated parent material. This shows that Co-alloy powder coating is highly recommendable for the durability improvement surface coating of high speed air-bearing spindle. At high temperature wear traces and friction coefficients of both coating and non-coating were drastically reduced compared with those of room temperature since the brittle oxides were formed easily on the surface, and the brittle oxide phases were attrited by the reciprocating sliding wear according to the complicated mixed wear mechanisms These oxide particles, partially melts and the melts play role as lubricant and reduce the wear and friction coefficient. This also shows that Co-alloy powder coating is highly recommendable far the durability improvement surface coating on the surface vulnerable to frictional heat such as high speed spindles.