• Title/Summary/Keyword: High voltage relay

Search Result 77, Processing Time 0.042 seconds

HBM ESD Tester for On-wafer Test using Flyback Method (Flyback 방식을 이용한 on-wafer용 HBM ESD 테스터 구현)

  • 박창근;염기수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1079-1083
    • /
    • 2002
  • We made ESD tester to measure ESD threshold voltage of semiconductor devices. The HBM ESD test is the most popular method to measure the ESD threshold voltage of MMSIC. We use flyback method which is one of the DC-DC converter to get high ESD voltage. With flvback method, we can isolate the 1ow voltage part from the high voltage part of HBM ESD tester. We use an air gap of the relay which is used for switch to satisfy the rise time of ESD standard(MIL-STD). As a result, with the flyback method and the air gap of relay, we can make ESD tester whose parasitic components are minimized.

HBM ESD Tester for On-wafer Test using Flyback Method (Flyback방식을 이용한 on-wafer용 HBM ESD 테스터 구현)

  • 박창근;염기수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.469-472
    • /
    • 2002
  • We made ESD tester to measure ESD threshold voltage of semiconductor devices. The HBM ESD test is the most popular method to measure the ESD threshold voltage of MMIC. We use flyback method which is one of the DC-DC converter to get high ESD voltage. With flyback method, we can isolate the low voltage part from the high voltage part of HBM ESD tester. We use an air gap of the relay which is used for switch to satisfy the rise time of ESD standard(MIL-STll-883D). As a result, with the flyback method and the air gap of relay, we can make ESD tester whose parasitic components are minimized.

  • PDF

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

Design and Implementation of PRA for a Power Supply of Electrical Vehicle (전기자동차의 전력공급을 위한 PRA 설계 및 구현)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.7
    • /
    • pp.653-658
    • /
    • 2016
  • As this paper is related to the relay and its driving control method, it explains about the relay which connects or interrupts the DC high voltage battery's power to drive the electric car's inverter. The paper suggests a sub-relay which prevents strong sparks from relay's contact point when the relay connects to the DC high voltage battery and also compensates for the increasing internal resistance value that is caused by deterioration at contact point. The relay's rated power is approximately 10KW and the relay's electric property has been verified through electrical instantaneous power short test, etc.

An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram (과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘)

  • 허정용;김철환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.161-167
    • /
    • 2004
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk lot mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel Zone 3 scheme based on combining the steady-state components (i.e. 60Hz) and the transient components (TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

Switched-voltage control of electrostatic suspension system

  • Woo, Shao-Ju;Jeon, Jong-Up;Higuchi, Toshiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.401-404
    • /
    • 1996
  • A new method for the electrostatic suspension of disk-shaped objects is proposed which is based on a switched-voltage control scheme. It operates according to a relay feedback control and deploys only a single high-voltage power supply capable of delivering a dc voltage of positive and/or negative polarity. In addition to the unique feature that no high-voltage amplifiers are needed, this method provides a remarkable system simplification relative to conventional methods. It is shown that despite the inherent limit cycle property of relay feedback based control, an excellent performance in vibration suppression is attained due to the presence of a relatively large squeeze film damping. In this paper, the functional principle of the switched voltage control scheme, numerical analysis, stator electrode design, and a nonlinear dynamic model of the suspension system are described. Experimental results will be presented for a 4-inch silicon wafer that clearly reveal the capability of the proposed control structure to suspend the wafer stably at an airgap length of 50 .mu.m.

  • PDF

Fault Detection Technique in Railway High Voltage Distribution Lines using Wavelet Transform (웨이브렛 변환을 이용한 철도 고압배전선로의 고장검출기법)

  • Jung Ho-Sung;Han Moon-Seob;Lee Chang-Mu;Kim Joorak;Lee Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1274-1279
    • /
    • 2004
  • This paper proposes technique to detect ground fault in railway high voltage distribution lines. Overcurrent relay technique is widely used for detecting one line ground fault that occurs most frequently in railway high voltage distribution lines. However, ground fault in distribution line is usually high impedance fault with arc. Because the fault current magnitude measured in substation is very small, the conventional overcurrent relay can't detect the high impedance ground fault. Therefore this paper proposes the advanced technique using wavelet transform. It extracts D1 component from fault signals and detects fault comparing magnitude of D1 component in each phase. To evaluate this proposed technique, we model distribution system using PSCAD/EMTDC and extract various fault data. In conclusion this technique can detect ground fault including high impedance fault regardless of fault distance, fault impedance etc.

  • PDF

Study on the High Sensitive Three Phase Power Factor Meter and Relay (고감도 삼상력률계전기에 관한 연구)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.16 no.1
    • /
    • pp.43-47
    • /
    • 1980
  • The author designed and tested the high sensitive three-phase power factor meter and relay circuit, and dealt with the circuit to detect the phase of the current and the voltage. An operational amplifier comparator circuit and two single-phase transformers are used to control and detect the phase angle between the current and the voltage. The results obtained are as follows: 1. Converting the sine wave input current into the constant amplitude rectangular wave form by using a transistor chopper circuit, the power factor can be measured precisely over the load current of 0.08 A. 2. Using the moving coil type current meter, the power factor meter can be read in uniform . scale all over the range. 3. Using the three-phase power factor meter, the power factor relay which works at any power factor can be made.

  • PDF

A Study on Optimum control for Inrush current of Microwave Oven using Statistical Method (통계적 방법에 의한 전자레인지의 돌입전류 최적화 연구)

  • 이민기;고강훈;권순걸;이현우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.61-67
    • /
    • 2001
  • Magnetic flux saturation dependent on phase of initial input power to high voltage transformer used in Micro wave oven. To limit inrush current high voltage transformer the relay contact should be ˝ON˝ when the lowest point of input voltage phase. The improved circuit is form compensating interrupt signal Micom input so the relay contact can be ˝ON˝ when the inrush current is lower. Test results are presented that improved circuit satisfies the limit 50[A] of requirement for input voltage variation mode. And the result verified by statistical method.

  • PDF

An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram (과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘)

  • Heo, J.Y.;Kim, C.H.;Park, N.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.245-247
    • /
    • 2003
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk for mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel zone 3 scheme based on combining the steady-state components(i.e. 60Hz) and the transient components(TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

  • PDF