• 제목/요약/키워드: High temperature storage test

검색결과 177건 처리시간 0.023초

저장온도 및 종자 처리가 봄파종 인삼 출아와 생장에 미치는 영향 (Effects of Storage Temperature and Seed Treatment on Emergence and Growth Properties of Panax ginseng at Spring-sowing)

  • 서수정;유진;장인복;문지원;이성우;장인배
    • 한국약용작물학회지
    • /
    • 제26권5호
    • /
    • pp.401-407
    • /
    • 2018
  • Background: In Korea, seeds of Panax ginseng C. A. Meyer need to be stored under cold temperature and high humidity condition for months to break physiological dormancy, making storage difficult until spring-sowing. This study was conducted to test the effects of seed storage conditions and seed treatment on the emergence of seedling after spring-sowing in a nursery greenhouse. Methods and Results: After dehiscence, endocarp dried seeds in mild or completely, and wet seeds were stored in $2^{\circ}C$ and $-3.5^{\circ}C$ during winter. Storage at $-3.5^{\circ}C$ resulted in a lower emergence rate (ER) than that at $2^{\circ}C$, and additional cold ($2^{\circ}C$) treatment before or after storage at $-3.5^{\circ}C$ increased the ER. Endocarp dehydration prevented pre-germination at $2^{\circ}C$ storage and increased the ER of seeds stored at $-3.5^{\circ}C$. ER was also dependent on the batch of seeds. However, seed treatments before sowing had only limited effects on ER. Root loss was the main reason for damping-off; prolonged cold storage of seeds increased damping-off, as the detection of pathogens was not high. Conclusions: This study showed that storage conditions such as temperature and moisture content of seeds, affect the ER after spring-sowing and vitality of seedlings, suggesting further attention on seed control for secure seedling stands after spring-sowing.

열사이클을 적용한 고온 조건 콘크리트 블록의 열용량 특성 (Thermal Energy Capacity of Concrete Blocks Subjected to High-Temperature Thermal Cycling)

  • 양인환;박지훈
    • 한국건설순환자원학회논문집
    • /
    • 제8권4호
    • /
    • pp.571-580
    • /
    • 2020
  • 본 연구에서는 열에너지 저장시스템의 중요한 요소인 저장 매체에 관한 연구를 수행하였다. 열에너지 저장 매체로써 콘크리트는 열적 및 역학적 특성이 우수하며 저렴한 비용으로 인해 다양한 이점을 갖는다. 또한, 강섬유가 혼입된 초고강도 콘크리트는 고인성 및 고강도 특성으로 인해 고온 노출에 우수한 내구성을 나타내며, 강섬유의 높은 열전도율은 축열 및 방열에 유리한 영향을 미친다. 초고강도 콘크리트의 온도분포 특성을 파악하기 위하여 콘크리트 블록을 제작하고 일정한 열사이클을 적용하여 가열실험을 수행하였다. 열유체 흐름에 의한 열전달을 위하여 열전달 파이프를 콘크리트 블록 중심부에 매립하였다. 또한, 열전달 파이프 형상에 따른 온도분포 특성을 비교하기 위하여 핀의 유무에 따라 원형 파이프 및 종방향 핀 부착 파이프를 설정하였다. 열사이클에 따른 온도분포 특성을 분석하고, 이를 토대로 시간에 따른 열에너지 및 누적 열에너지를 산정하여 비교 분석하였다. 열사이클이 반복될수록 강섬유 혼입 초고강도 콘크리트는 고온에 대하여 안정화를 나타내었다. 또한, 온도분포 및 열에너지 산정 결과를 통해 축열 성능을 보유한 것으로 판단되며, 열에너지 저장 매체 역할을 수행할 수 있는 재료로 기대된다.

축열식 가열기의 설계 및 제작 (Design and Manufacture of Storage Air Heater)

  • 이양지;강상훈;박부민;양수석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.43-46
    • /
    • 2006
  • 축열식 가열기는 주로 초음속 지상추진 시험설비의 고고도 조건 모사를 위하여 구축되는 장비로 이외에도 로켓 엔진 노즐의 추력 보정시험, 가스터빈 엔진 연소기 모사시험에 범용으로 사용할 수 있다. 한국항공우주연구원에서 보유하고 있는 축열식 가열시스템은 마하 $2{\sim}5$, 고도 $0{\sim}25km$의 범위에서 구동하는 초음속 지상추진시험설비의 전온도 모사를 목적으로 설계되었으며, 최고 모사 온도 1,300 K, 최고 가압압력 3.5 MPa의 성능을 낸다. 본 논문에는 본 원에서 구축한 축열식 가열기의 목표로 한 일본 JAXA RJTF에 구축되어있는 축열식 가열기에 대하여 정리하도록 한다.

  • PDF

Bendable 임베디드 전자모듈의 손상 메커니즘 (Failure Mechanism of Bendable Embedded Electronic Module Under Various Environment Conditions)

  • 조윤성;김아영;홍원식
    • Journal of Welding and Joining
    • /
    • 제31권5호
    • /
    • pp.59-63
    • /
    • 2013
  • A bendable electronic module has been developed for a mobile application by using a low-cost roll-to-roll manufacturing process. In flexible embedded electronic module, a thin silicon chip was embedded in a polymer-based encapsulating adhesive between flexible copper clad polyimide layers. To confirm reliability and durability of prototype bendable module, the following tests were conducted: Moisture sensitivity level, thermal shock test, high temperature & high humidity storage test, and pressure cooker tester. Those experiments to induce failure of the module due to temperature variations and moisture are the experiment to verify the reliability. Failure criterion was 20% increase in bump resistance from the initial value. The mechanism of the increase of the bump resistance was analyzed by using non-destructive X-ray analysis and scanning acoustic microscopy. During the pressure cooker test (PCT), delamination occurred at the various interfaces of the bendable embedded modules. To investigate the failure mechanism, moisture diffusion analysis was conducted to the pressure cooker's test. The hygroscopic characteristics of the encapsulating polymeric materials were experimentally determined. Analysis results have shown moisture saturation process of flexible module under high temperature/high humidity and high atmosphere conditions. Based on these results, stress factor and failure mechanism/mode of bendable embedded electronic module were obtained.

복합재 고압용기의 스마트 모니터링을 위한 FBG 센서의 삽입 적용성에 관한 연구 (Feasibility Study of Embedded FBG Sensors for the Smart Monitoring of High Pressure Composite Vessel)

  • 박상욱;박상오;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.33-36
    • /
    • 2005
  • In this research, for the smart health monitoring of the hydrogen storage high pressure composite vessel, the feasibility study of an embedded fiber Bragg grating(FBG) sensor is carried out. To verify strain measurement in various temperature environment which is needed for the hydrogen pressure vessel, tensile test of a composite specimen with both an embedded FBG sensor and a strain gauge is made in low temperature. Before we try a real-size hydrogen storage pressure vessel, a small & cheap composite pressure vessel having the same structure is fabricated with embedded FBG sensors and tested. In the case of an aluminum liner inside the vessel, survivability of FBG sensors at the interface is lower than the other areas.

  • PDF

멤브레인 LNG 저장탱크용 STS304L의 인장 및 피로강도 (Tensile and Fatigue Strengths of STS304L for LNG Membrane Storage Tank)

  • 나성현;김영균;김재훈
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.9-14
    • /
    • 2016
  • STS304L of membrane structure has been used for a LNG storage tank and has exposed long time under the cryogenic temperature. The purposes of this study are to evaluate the mechanical properties of base and used materials for STS304L of membrane. The tensile and high cycle fatigue tests were investigated for STS304L of membrane used over 20 years at room temperature and $-162^{\circ}C$. In addition, the test of base STS304L was performed in order to compare with used material properties. The chemical composition and phase change were investigated from EDS and XRD. From results of tensile test, yield and ultimate tensile strengths of used STS304L are smaller than those of base STS304L. S-N curves were obtained from fatigue tests at both temperatures. Also, P-S-N curves were presented with statistical method recommend by JSME-S002. Fractography was conducted for analysis of fracture mechanisms.

Allowable peak heat-up cladding temperature for spent fuel integrity during interim-dry storage

  • Jang, Ki-Nam;Cha, Hyun-Jin;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1740-1747
    • /
    • 2017
  • To investigate allowable peak cladding temperature and hoop stress for maintenance of cladding integrity during interim-dry storage and subsequent transport, zirconium alloy cladding tubes were hydrogen-charged to generate 250 ppm and 500 ppm hydrogen contents, simulating spent nuclear fuel degradation. The hydrogen-charged specimens were heated to four peak temperatures of $250^{\circ}C$, $300^{\circ}C$, $350^{\circ}C$, and $400^{\circ}C$, and then cooled to room temperature at cooling rates of $0.3^{\circ}C/min$ under three tensile hoop stresses of 80 MPa, 100 MPa, and 120 MPa. The cool-down specimens showed that high peak heat-up temperature led to lower hydrogen content and that larger tensile hoop stress generated larger radial hydride fraction and consequently lower plastic elongation. Based on these out-of-pile cladding tube test results only, it may be said that peak cladding temperature should be limited to a level < $250^{\circ}C$, regardless of the cladding hoop stress, to ensure cladding integrity during interim-dry storage and subsequent transport.

삼중수소 저장용기 이종 접합부의 수소 취성 (Hydrogen Brittleness on Welding Part for SDS Bottles)

  • 김경일;정석;강현구;장민호;윤세훈;홍태환
    • 한국수소및신에너지학회논문집
    • /
    • 제24권2호
    • /
    • pp.121-127
    • /
    • 2013
  • Tritium was attracted with high energy source in neutron fusion energy systems. A number of research was performed in tritium storage materials. The Korea was raised storage and delivery systems (SDS) of international thermonuclear experimental reactor (ITER) research. However, bottles of SDS would be important because of stability. The bottles have a welding zone, this zone will be vulnerable to hydrogen embrittlement. This zone have a high thermodynamic energy and heat deterioration. Therefore bottles were studied about hydrogen embrittlement to retain stability. The heat treatment of hydrogen was carried under pressure-composition-temperature (PCT) apparatus because of checking at real time. And then, mechanical properties were evaluated by tensile test and hardness test. In results of this study, hydrogen atmosphere condition is very important by tensile test and kinetics test. The samples were evaluated, that is more weak hydrogen pressure, increasing temperature and time. This results could be useful in SDS bottle designs.

Practical Application of Lead-free Solder in Electronic Products

  • Cho Il-Je;Chae Kyu-Sang;Min Jae-Sang;Kim Ik-Joo
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2004년도 ISMP Pb-free solders and the PCB technologies related to Pb-free solders
    • /
    • pp.93-99
    • /
    • 2004
  • At present, LG Electronics pushes ahead to eliminate the Pb(Lead) -a hazardous material- from all products. Especially, we have performed to select the optimum standard composition of lead free alloy for the application to products for about 3 years from 2000. These days, we have the chance for applying to the mass-production. This project constructed the system for applying the lead free solders on consumer electronic products, which is one of the major products of the LG Electronics. To select the lead free solders with corresponding to the product features, we have passed through the test and applied with Sn-3.0Ag-0.5Cu alloy system to our products, and for the application to the high melting temperature composition, we secured the thermal resistance of the many parts and substrate and optimized the processing conditions. We have operated the temperature cycling test and the high temperature storage test under the standards to confirm the reliability of the products. On these samples, we considered the consequence of our decision by the operating test. For the long life time of the product, we have operated the temperature cycling test at $-45^{\circ}C-+125^{\circ}C$, 1 cycle/hour, 1000 cycles. Also we have tested the tin whisker growth about lead free plating on lead finish. We have analyzed with the SEM, EDS and any other equipment for confirming the failure mode at the joint and the tin whisker growth on lead free finish.

  • PDF

고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성 (Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.